Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Opt Express ; 32(10): 17479-17480, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38858930

RESUMO

This erratum corrects errors that appear in Opt. Express31, 5042 (2023).10.1364/OE.480301.

2.
Opt Express ; 31(3): 5042-5055, 2023 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-36785456

RESUMO

Dual-comb spectroscopy measures greenhouse gas concentrations over kilometers of open air with high precision. However, the accuracy of these outdoor spectra is challenging to disentangle from the absorption model and the fluctuating, heterogenous concentrations over these paths. Relative to greenhouse gases, O2 concentrations are well-known and evenly mixed throughout the atmosphere. Assuming a constant O2 background, we can use O2 concentration measurements to evaluate the consistency of open-path dual-comb spectroscopy with laboratory-derived absorption models. To this end, we construct a dual-comb spectrometer spanning 1240 nm to 1700nm, which measures O2 absorption features in addition to CO2 and CH4. O2 concentration measurements across a 560 m round-trip outdoor path reach 0.1% precision in 10 minutes. Over seven days of shifting meteorology and spectrometer conditions, the measured O2 has -0.07% mean bias, and 90% of the measurements are within 0.4% of the expected hemisphere-average concentration. The excursions of up to 0.4% seem to track outdoor temperature and humidity, suggesting that accuracy may be limited by the O2 absorption model or by water interference. This simultaneous O2, CO2, and CH4 spectrometer will be useful for measuring accurate CO2 mole fractions over vertical or many-kilometer open-air paths, where the air density varies.

3.
Opt Express ; 31(18): 29074-29084, 2023 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-37710714

RESUMO

Operation of any dual-comb spectrometer requires digitization of the interference signal before further processing. Nonlinearities in the analog-to-digital conversion can alter the apparent gas concentration by multiple percent, limiting both precision and accuracy of this technique. This work describes both the measurement of digitizer nonlinearity and the development of a model that quantitatively describes observed concentration bias over a range of conditions. We present hardware methods to suppress digitizer-induced bias of concentration retrievals below 0.1%.

4.
Opt Express ; 28(10): 14740-14752, 2020 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-32403509

RESUMO

This manuscript describes the design of a robust, mid-infrared dual-comb spectrometer operating in the 3.1-µm to 4-µm spectral window for future field applications. The design represents an improvement in system size, power consumption, and robustness relative to previous work while also providing a high spectral signal-to-noise ratio. We demonstrate a system quality factor of 2×106 and 30 hours of continuous operation over a 120-meter outdoor air path.

5.
Opt Express ; 27(8): 11869-11876, 2019 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-31053026

RESUMO

Si3N4 waveguides, pumped at 1550 nm, can provide spectrally smooth, broadband light for gas spectroscopy in the important 2 µm to 2.5 µm atmospheric water window, which is only partially accessible with silica-fiber based systems. By combining Er+ fiber frequency combs and supercontinuum generation in tailored Si3N4 waveguides, high signal-to-noise dual-comb spectroscopy spanning 2 µm to 2.5 µm is demonstrated. Acquired broadband dual-comb spectra of CO and CO2 agree well with database line shape models and have a spectral-signal-to-noise as high as 48/√s, showing that the high coherence between the two combs is retained in the Si3N4 supercontinuum generation. The dual-comb spectroscopy figure of merit is 6 × 106/√s, equivalent to that of all-fiber dual-comb spectroscopy systems in the 1.6 µm band. based on these results, future dual-comb spectroscopy can combine fiber comb technology with Si3N4 waveguides to access new spectral windows in a robust non-laboratory platform.

6.
J Quant Spectrosc Radiat Transf ; 217: 189-212, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32913374

RESUMO

We report argon-broadened water vapor transition parameters and their temperature dependence based on measured spectra spanning 6801-7188 cm-1 from a broad-bandwidth, high-resolution dual frequency comb spectrometer. The 25 collected spectra of 2% water vapor in argon ranged from 296 K to 1305 K with total pressure spanning 100 Torr to 600 Torr. A multispectrum fitting routine was used in conjunction with a quadratic speed-dependent Voigt profile to extract broadening and shift parameters, and a power-law temperature-dependence exponent for both. The measurements represent the first broad bandwidth, argon-broadened water vapor absorption study, and are an important step toward a foreign-gas-perturbed, high-temperature database developed using advanced lineshape profiles.

7.
J Quant Spectrosc Radiat Transf ; 210: 240-250, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-32934421

RESUMO

We measure speed-dependent Voigt lineshape parameters with temperature-dependence exponents for several hundred spectroscopic features of pure water spanning 6801-7188 cm-1. The parameters are extracted from broad bandwidth, high-resolution dual frequency comb absorption spectra with multispectrum fitting techniques. The data encompass 25 spectra ranging from 296 K to 1305 K and 1 to 17 Torr of pure water vapor. We present the extracted parameters, compare them to published data, and present speed-dependence, self-shift, and self-broadening temperature-dependent parameters for the first time. Lineshape data is extracted using a quadratic speed-dependent Voigt profile and a single self-broadening power law temperature-dependence exponent over the entire temperature range. The results represent an important step toward a new high-temperature database using advanced lineshape profiles.

8.
Opt Express ; 24(26): 30495-30504, 2016 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-28059397

RESUMO

We describe a dual-comb spectrometer that can operate independently of laboratory-based rf and optical frequency references but is nevertheless capable of ultra-high spectral resolution, high SNR, and frequency-accurate spectral measurements. The instrument is based on a "bootstrapped" frequency referencing scheme in which short-term optical phase coherence between combs is attained by referencing each to a free-running diode laser, whilst high frequency resolution and long-term accuracy is derived from a stable quartz oscillator. The sensitivity, stability and accuracy of this spectrometer were characterized using a multipass cell. We demonstrate comb-resolved spectra spanning from 140 THz (2.14 µm, 4670 cm-1) to 184 THz (1.63 µm, 6140 cm-1) in the near infrared with a frequency sampling of 200 MHz (0.0067 cm-1) and ~1 MHz frequency accuracy. High resolution spectra of water and carbon dioxide transitions at 1.77 µm, 1.96 µm and 2.06 µm show that the molecular transmission acquired with this system operating in the field-mode did not deviate from those measured when it was referenced to a maser and cavity-stabilized laser to within 5.6 × 10-4. When optimized for carbon dioxide quantification at 1.60 µm, a sensitivity of 2.8 ppm-km at 1 s integration time, improving to 0.10 ppm-km at 13 minutes of integration time was achieved.

9.
Opt Express ; 23(20): 26814-24, 2015 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-26480192

RESUMO

Mid-infrared femtosecond optical frequency combs were produced by difference frequency generation of the spectral components of a near-infrared comb in a 3-mm-long MgO:PPLN crystal. We observe strong pump depletion and 9.3 dB parametric gain in the 1.5 µm signal, which yields powers above 500 mW (3 µW/mode) in the idler with spectra covering 2.8 µm to 3.5 µm. Potential for broadband, high-resolution molecular spectroscopy is demonstrated by absorption spectra and interferograms obtained by heterodyning two combs.

10.
Phys Rev Lett ; 115(10): 103901, 2015 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-26382677

RESUMO

Broadband atmospheric phase spectra are acquired with a phase-sensitive dual-frequency-comb spectrometer by implementing adaptive compensation for the strong decoherence from atmospheric turbulence. The compensation is possible due to the pistonlike behavior of turbulence across a single spatial-mode path combined with the intrinsic frequency stability and high sampling speed associated with dual-comb spectroscopy. The atmospheric phase spectrum is measured across 2 km of air at each of the 70,000 comb teeth spanning 233 cm(-1) across hundreds of near-infrared rovibrational resonances of CO(2), CH(4), and H(2)O with submilliradian uncertainty, corresponding to a 10(-13) refractive index sensitivity. Trace gas concentrations extracted directly from the phase spectrum reach 0.7 ppm uncertainty, demonstrated here for CO(2). While conventional broadband spectroscopy only measures intensity absorption, this approach enables measurement of the full complex susceptibility even in practical open path sensing.

11.
Opt Lett ; 39(16): 4776-9, 2014 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-25121872

RESUMO

Frequency-modulated continuous-wave laser detection and ranging (FMCW LADAR) measures the range to a surface through coherent detection of the backscattered light from a frequency-swept laser source. The ultimate limit to the range precision of FMCW LADAR, or any coherent LADAR, to a diffusely scattering surface will be determined by the unavoidable speckle phase noise. Here, we demonstrate the two main manifestations of this limit. First, frequency-dependent speckle phase noise leads to a non-Gaussian range distribution having outliers that approach the system range resolution, regardless of the signal-to-noise ratio. These outliers are reduced only through improved range resolution (i.e., higher optical bandwidths). Second, if the range is measured during a continuous lateral scan across a surface, the spatial pattern of speckle phase is converted to frequency noise, which leads to additional excess range uncertainty. We explore these two effects and show that laboratory results agree with analytical expressions and numerical simulations. We also show that at 1 THz optical bandwidth, range precisions below 10 µm are achievable regardless of these effects.

12.
Opt Express ; 21(1): 1020-9, 2013 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-23388996

RESUMO

We present absolute line center frequencies for 24 fundamental ν3 ro-vibrational P-branch transitions near 4.5 µm in N2O with an absolute expanded (multiplied by 2) frequency uncertainty of 800 kHz. The spectra are acquired with a swept laser spectrometer consisting of an external-cavity quantum cascade laser whose instantaneous frequency is continuously tracked against a near-infrared frequency comb. The measured absorbance profiles have a well-calibrated frequency axis, and are fitted to determine absolute line center values. We discuss the main sources of uncertainty.

13.
Opt Lett ; 38(12): 2026-8, 2013 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-23938965

RESUMO

We demonstrate a comb-calibrated frequency-modulated continuous-wave laser detection and ranging (FMCW ladar) system for absolute distance measurements. The FMCW ladar uses a compact external cavity laser that is swept quasi-sinusoidally over 1 THz at a 1 kHz rate. The system simultaneously records the heterodyne FMCW ladar signal and the instantaneous laser frequency at sweep rates up to 3400 THz/s, as measured against a free-running frequency comb (femtosecond fiber laser). Demodulation of the ladar signal against the instantaneous laser frequency yields the range to the target with 1 ms update rates, bandwidth-limited 130 µm resolution and a ~100 nm accuracy that is directly linked to the counted repetition rate of the comb. The precision is <100 nm at the 1 ms update rate and reaches ~6 nm for a 100 ms average.

14.
Atmos Meas Tech ; 16(17)2023.
Artigo em Inglês | MEDLINE | ID: mdl-37961051

RESUMO

We present an open-path mid-infrared dual-comb spectroscopy (DCS) system capable of precise measurement of the stable water isotopologues H216O and HD16O. This system ran in a remote configuration at a rural test site for 3.75 months with 60% uptime and achieved a precision of < 2‰ on the normalized ratio of H216O and HD16O (δD) in 1000s. Here, we compare the δD values from the DCS system to those from the National Ecological Observatory Network (NEON) isotopologue point sensor network. Over the multi-month campaign, the mean difference between the DCS δD values and the NEON δD values from a similar ecosystem is < 2‰ with a standard deviation of 18‰, which demonstrates the inherent accuracy of DCS measurements over a variety of atmospheric conditions. We observe time-varying diurnal profiles and seasonal trends that are mostly correlated between the sites on daily timescales. This observation motivates the development of denser ecological monitoring networks aimed at understanding regional- and synoptic-scale water transport. Precise and accurate open-path measurements using DCS provide new capabilities for such networks.

15.
Front Chem ; 11: 1202255, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37332891

RESUMO

We present results from a field study monitoring methane and volatile organic compound emissions near an unconventional oil well development in Northern Colorado from September 2019 to May 2020 using a mid-infrared dual-comb spectrometer. This instrument allowed quantification of methane, ethane, and propane in a single measurement with high time resolution and integrated path sampling. Using ethane and propane as tracer gases for methane from oil and gas activity, we observed emissions during the drilling, hydraulic fracturing, millout, and flowback phases of well development. Large emissions were seen in drilling and millout phases and emissions decreased to background levels during the flowback phase. Ethane/methane and propane/methane ratios varied widely throughout the observations.

16.
Opt Express ; 20(11): 12432-42, 2012 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-22714230

RESUMO

The instantaneous optical frequency of an external-cavity quantum cascade laser (QCL) is characterized by comparison to a near-infrared frequency comb. Fluctuations in the instantaneous optical frequency are analyzed to determine the frequency-noise power spectral density for the external-cavity QCL both during fixed-wavelength and swept-wavelength operation. The noise performance of a near-infrared external-cavity diode laser is measured for comparison. In addition to providing basic frequency metrology of external-cavity QCLs, this comb-calibrated swept QCL system can be applied to rapid, precise broadband spectroscopy in the mid-infrared spectral region.


Assuntos
Desenho Assistido por Computador , Lasers , Modelos Teóricos , Refratometria/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Espalhamento de Radiação
17.
Opt Express ; 19(24): 24387-95, 2011 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-22109466

RESUMO

Low phase-noise microwave generation has previously been demonstrated using self-referenced frequency combs to divide down a low noise optical reference. We demonstrate an approach based on a fs Er-fiber laser that avoids the complexity of self-referenced stabilization of the offset frequency. Instead, the repetition rate of the femtosecond Er-fiber laser is phase locked to two cavity-stabilized cw fiber lasers that span 3.74 THz by use of an intracavity electro-optic modulator with over 2 MHz feedback bandwidth. The fs fiber laser effectively divides the 3.74 THz difference signal to produce microwave signals at harmonics of the repetition rate. Through comparison of two identical dividers, we measure a residual phase noise on a 1.5 GHz carrier of -120 dBc/Hz at 1 Hz offset.


Assuntos
Eletrônica/instrumentação , Tecnologia de Fibra Óptica/instrumentação , Lasers , Micro-Ondas , Dispositivos Ópticos , Telecomunicações/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
18.
Opt Lett ; 36(7): 1152-4, 2011 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-21479013

RESUMO

The optical frequency sweep of an actively linearized, ultrabroadband, chirped laser source is characterized through optical heterodyne detection against a fiber-laser frequency comb. Frequency sweeps were measured over approximately 5 THz bandwidths from 1530 nm to 1570 nm. The dominant deviation from linearity resulted from the nonzero dispersion of the fiber delay used as a reference for the sweep linearization. Removing the low-order dispersion effects, the residual sweep nonlinearity was less than 60 kHz rms, corresponding to a constant chirp with less than 15 ppb deviation across the 5 THz sweep.

19.
Sci Adv ; 7(14)2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33789900

RESUMO

Advances in spectroscopy have the potential to improve our understanding of agricultural processes and associated trace gas emissions. We implement field-deployed, open-path dual-comb spectroscopy (DCS) for precise multispecies emissions estimation from livestock. With broad atmospheric dual-comb spectra, we interrogate upwind and downwind paths from pens containing approximately 300 head of cattle, providing time-resolved concentration enhancements and fluxes of CH4, NH3, CO2, and H2O. The methane fluxes determined from DCS data and fluxes obtained with a colocated closed-path cavity ring-down spectroscopy gas analyzer agree to within 6%. The NH3 concentration retrievals have sensitivity of 10 parts per billion and yield corresponding NH3 fluxes with a statistical precision of 8% and low systematic uncertainty. Open-path DCS offers accurate multispecies agricultural gas flux quantification without external calibration and is easily extended to larger agricultural systems where point-sampling-based approaches are insufficient, presenting opportunities for field-scale biogeochemical studies and ecological monitoring.

20.
Nat Commun ; 11(1): 3152, 2020 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-32561738

RESUMO

Spectrally resolved photoacoustic imaging is promising for label-free imaging in optically scattering materials. However, this technique often requires acquisition of a separate image at each wavelength of interest. This reduces imaging speeds and causes errors if the sample changes in time between images acquired at different wavelengths. We demonstrate a solution to this problem by using dual-comb spectroscopy for photoacoustic measurements. This approach enables a photoacoustic measurement at thousands of wavelengths simultaneously. In this technique, two optical-frequency combs are interfered on a sample and the resulting pressure wave is measured with an ultrasound transducer. This acoustic signal is processed in the frequency-domain to obtain an optical absorption spectrum. For a proof-of-concept demonstration, we measure photoacoustic signals from polymer films. The absorption spectra obtained from these measurements agree with those measured using a spectrophotometer. Improving the signal-to-noise ratio of the dual-comb photoacoustic spectrometer could enable high-speed spectrally resolved photoacoustic imaging.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA