Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Air Waste Manag Assoc ; 72(8): 849-875, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35363604

RESUMO

This paper reports the design and qualification of the first purpose-built, bench-scale reactor system to model the municipal waste-to-energy combustion of fluorinated polymers. Using the principle of similarity, the gas-phase combustion zone of a typical municipal waste-to-energy plant has been scaled down to the bench with a focus on chemical similarity. Chemical similarity is achieved in large part through the use of methanol as a surrogate for municipal solid waste (MSW). Review of prior research shows that methanol is one of the major volatile products expected during MSW thermal conversion in the fuel bed of waste-to-energy plants. Like full-scale waste-energy plants, the design of the bench-scale model includes a flame zone and a post-flame zone. Maintaining steady methanol vapor flow premixed with air to the model reactor system ensures stable combustion resulting in bench-scale CO emission levels comparable to those of full-scale waste-to-energy plants. Since investigation of fluorinated polymer combustion includes trace analysis of exhaust gas for perfluorooctanoic acid (PFOA), qualification testing focused on PFOA collection efficiency. High PFOA collection efficiency (>90%) demonstrated the capability of the reactor system in transporting and absorbing PFOA that may be generated during high-temperature combustion testing of fluorinated polymers. Overall, the bench-scale system is qualified for its intended use to investigate potential generation of PFOA from combustion of fluorinated polymers under conditions representative of waste-to-energy combustion.Implications: Decision-makers depend on environmental researchers to provide reliable predictions of pollutant emissions from waste combustion of polymers at end of product life. Reliable predictions are especially important with regard to questions about potential PFOA emissions from municipal waste combustion of fluorinated polymers. Results from qualification testing confirm that the novel bench-scale model reactor system is capable of representing gas-phase municipal waste combustion behavior upstream of air pollution control and generating representative exhaust gas samples for off-line trace-level analysis of PFOA.


Assuntos
Incineração , Metanol , Polímeros de Fluorcarboneto , Gases/análise , Incineração/métodos , Resíduos Sólidos/análise
2.
Waste Manag ; 132: 124-132, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34329926

RESUMO

This paper reports the first known comprehensive survey of combustion operating conditions across the wide range of municipal waste-to-energy facilities in the U.S. The survey was conducted in a step-wise fashion. Once the population of 188 units operating at over 70 facilities was defined, this population was stratified by distinguishing characteristics of combustion technology. Stratum-level estimates for operating conditions were determined from data collected in the survey. These stratum-level values were weighted by corresponding design capacity share and combined to infer national-level operating parameter estimates representative of the overall population. Survey results show that typical municipal waste-to-energy combustion operating conditions in the U.S. are (1) furnace temperature above 1160 °C, (2) gas residence time above 2.4 s, (3) exit gas concentrations of nearly 10% for oxygen (dry basis), and (4) over 16% for moisture. These operating parameter values can serve as benchmarks for laboratory-scale studies representative of municipal waste-to-energy combustion as typically practiced in the U.S.


Assuntos
Incineração , Eliminação de Resíduos , Oxigênio , Resíduos Sólidos/análise , Temperatura
3.
Chemosphere ; 61(7): 974-84, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16257319

RESUMO

This study reports the first known studies to investigate the thermal degradation of a polyester/cellulose fabric substrate ("article") treated with a fluorotelomer-based acrylic polymer under laboratory conditions conservatively representing typical combustion conditions of time, temperature, and excess air level in a municipal incinerator, with an average temperature of 1000 degrees C or greater over approximately 2s residence time. The results demonstrate that the polyester/cellulose fabric treated with a fluorotelomer-based acrylic polymer is destroyed and no detectable amount of perfluorooctanoic acid (PFOA) is formed under typical municipal incineration conditions. Therefore, textiles and paper treated with such a fluorotelomer-based acrylic polymer disposed of in municipal waste and incinerated are expected to be destroyed and not be a significant source of PFOA in the environment.


Assuntos
Resinas Acrílicas , Poluentes Atmosféricos/análise , Caprilatos/análise , Polímeros de Fluorcarboneto , Fluorocarbonos/análise , Incineração , Têxteis , Celulose , Cromatografia Gasosa-Espectrometria de Massas , Poliésteres , Termogravimetria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA