Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Opt Lett ; 48(24): 6484-6487, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38099779

RESUMO

We demonstrate a continuously tunable mid-infrared source that produces narrowband radiation at 1981 nm and 2145 nm based on a tunable Yb-based hybrid MOPA pump and a backward-wave optical parametric oscillator (BWOPO). The BWOPO employs a PPRKTP crystal with 580 nm domain periodicity. The BWOPO has a record-low oscillation threshold of 19.2 MW/cm2 and generates mJ level output with an overall efficiency exceeding 70%, reaching an average power of 5.65W at the repetition rate of 5 kHz. The system is mechanically robust and optical cavity-free, making it suitable for spectroscopic systems on mobile platforms. The mid-infrared signal frequency is tuned by pump tuning with a linear pump-to-signal frequency translation rate close to the predicted 1 to 1.001 Hz/Hz.

2.
Opt Express ; 30(26): 47199-47215, 2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36558654

RESUMO

This paper presents a first demonstration of range-resolved differential absorption LIDAR (DIAL) measurements of the water vapor main isotopologue H2 16O and the less abundant semi-heavy water isotopologue HD16O with the aim of determining the isotopic ratio. The presented Water Vapor and Isotope Lidar (WaVIL) instrument is based on a parametric laser source emitting nanosecond pulses at 1.98 µm and a direct-detection receiver utilizing a commercial InGaAs PIN photodiode. Vertical profiles of H2 16O and HD16O were acquired in the planetary boundary layer in the suburban Paris region up to a range of 1.5 km. For time averaging over 25 min, the achieved precision in the retrieved water vapor mixing ratio is 0.1 g kg-1 (2.5% relative error) at 0.4 km above ground level (a.g.l.) and 0.6 g kg-1 (20%) at 1 km a.g.l. for 150 m range bins along the LIDAR line of sight. For HD16O, weaker absorption has to be balanced with coarser vertical resolution (600 m range bins) in order to achieve similar relative precision. From the DIAL measurements of H2 16O and HD16O, the isotopic abundance δD was estimated as -51‰ at 0.4 km above the ground and -119‰ in the upper part of the boundary layer at 1.3 km a.g.l. Random and systematic errors are discussed in the form of an error budget, which shows that further instrumental improvements are required on the challenging path towards DIAL-profiling of the isotopic abundance with range resolution and precision suitable for water cycle studies.

3.
Opt Express ; 28(4): 5013-5021, 2020 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-32121730

RESUMO

A pulsed, single longitudinal mode, wavelength-tunable Tm:YAP laser is reported. We demonstrate 1 kHz stable operation with 230 µJ, 50 ns pulses and a spectrum linewidth narrowed below 4 pm (FWHM) close to the Fourier transform limit by use of a volume Bragg grating and a YAG etalon. The output wavelength was tuned from 1940 to 1960 nm owing to a transverse chirp of the period of the Bragg grating.

4.
Opt Lett ; 45(3): 607-610, 2020 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-32004263

RESUMO

We report on single-longitudinal-mode (SLM) operation of a low-threshold optical parametric oscillator, with a 17 nm tunability near 2 µm. The oscillator uses a MgO:PPLN crystal in Type 0 quasi-phase-matching configuration, pumped by a 1.064 µm SLM laser. Despite the huge acceptance bandwidth near-degeneracy of MgO:PPLN, spectral selection down to a SLM is achieved by combining a volume Bragg reflector and Vernier filtering in nested signal and idler cavities. Tunability over 17 nm is demonstrated owing to a transverse chirp of the grating period of the Bragg reflector.

5.
Appl Opt ; 59(35): 11156-11166, 2020 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-33361945

RESUMO

We have designed and built a wavelength-tunable optical source for standoff detection of gaseous chemicals by differential absorption spectrometry in the long-wave infrared. It is based on a nanosecond 2 µm single-frequency optical parametric oscillator, whose idler wave is amplified in large aperture Rb:PPKTP crystals. The signal and idler waves are mixed in ZnGeP2 crystals to produce single-frequency tunable radiation in the 7.5-10.5 µm range. The source was integrated into a direct detection lidar to measure sarin and sulfur mustard inside a closed chamber, in an integrated path configuration with a noncooperative target.

6.
Sensors (Basel) ; 19(6)2019 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-30893769

RESUMO

We have designed and fabricated a custom quartz tuning fork (QTF) with a reduced fundamental frequency; a larger gap between the prongs; and the best quality factor in air at atmospheric conditions ever reported, to our knowledge. Acoustic microresonators have been added to the QTF in order to enhance the sensor sensitivity. We demonstrate a normalized noise equivalent absorption (NNEA) of 3.7 × 10-9 W.cm-1.Hz-1/2 for CO2 detection at atmospheric pressure. The influence of the inner diameter and length of the microresonators has been studied, as well as the penetration depth between the QTF's prongs. We investigated the acoustic isolation of our system and measured the Allan deviation of the sensor.

7.
Opt Lett ; 43(3): 494, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-29400823

RESUMO

This erratum is to correct an error made in our paper [Opt. Lett.40, 280 (2015)OPLEDP0146-959210.1364/OL.40.000280] regarding the sign of the quasi-phase matching chirp rate.

8.
Opt Lett ; 42(20): 4044-4047, 2017 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-29028008

RESUMO

We report on the capability of a direct detection differential absorption lidar (DIAL) for range resolved and integrated path (IPDIAL) remote sensing of CO2 in the atmospheric boundary layer (ABL). The laser source is an amplified nested cavity optical parametric oscillator (NesCOPO) emitting approximately 8 mJ at the two measurement wavelengths selected near 2050 nm. Direct detection atmospheric measurements are taken from the ground using a 30 Hz frequency switching between emitted wavelengths. Results show that comparable precision measurements are achieved in DIAL and IPDIAL modes (not better than a few ppm) on high SNR targets such as near range ABL aerosol and clouds, respectively. Instrumental limitations are analyzed and degradation due to cloud scattering variability is discussed to explain observed DIAL and IPDIAL limitations.

9.
Opt Express ; 24(10): 11112-25, 2016 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-27409934

RESUMO

A new optical parametric oscillator (OPO) architecture with high tuning speed capability is demonstrated. This device exploits the versatility offered by aperiodic quasi-phase matching (QPM) to provide a broad parametric gain spectrum without changing the temperature, angle, or position of the nonlinear crystal. Rapid tuning is then straightforwardly achieved using a fast intracavity spectral filter. This concept is demonstrated here for a picosecond synchronously pumped OPO containing an aperiodically poled MgO-doped LiNbO3 crystal and a rapidly tunable spectral filter based on a diffraction grating. Tuning over 160 nm around 3.86 µm is achieved at fixed temperature and a fast tuning over 30 nm in 40 µs is demonstrated. Different configurations are tested and compared. The cavity length detuning is analyzed and discussed. This device is successfully used to detect N2O by absorption. This approach could be generalized to other spectral ranges (e.g., visible) and temporal regimes (e.g., continuous-wave or nanosecond).

10.
Opt Lett ; 41(17): 4060-3, 2016 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-27607972

RESUMO

We report on a widely tunable synchronously pumped picosecond optical parametric oscillator (OPO) combining an aperiodically poled MgO-doped LiNbO3 crystal as a broadband gain medium and an axially chirped volume Bragg grating as a spectral filtering dispersive element. Translation of the Bragg grating along the beam axis enables wavelength tuning over 215 nm around 3.82 µm and provides spectral narrowing. Rapid continuous tuning over 150 nm in 100 ms is demonstrated.

11.
Opt Express ; 21(23): 28886-91, 2013 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-24514402

RESUMO

We conceived a unique fully parametric source based on two independent cylindrical OPOs simultaneously pumped by the same Nd:YAG laser. Each OPO delivers more than 2 mJ and is continuously tunable between 1.41 µm and 4.3 µm. This source is of particular interest for the study of the generation of infrared parametric light in nonlinear crystals. It was validated by performing difference frequency generation experiments in CdSe crystals with output in the range 8 - 10 µm.

12.
Opt Lett ; 38(20): 4046-9, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-24321919

RESUMO

We demonstrate optical parametric amplification in ZnGeP(2) (ZGP) of the radiation emitted by a single-frequency continuous-wave quantum cascade laser (QCL) in the range 7.8-8.4 µm. The ZGP amplifier is pumped by a single-frequency parametric source at 2210 nm. For a pump energy of 6 mJ, we report an average gain of 50 over this range and a maximum gain of 111 for 7.5 mJ. An exponential trend is observed when changing the pump energy, with very good agreement with theory. These features are of valuable interest for increasing the standoff detection range of hazardous chemicals and explosives by QCL-based backscattering spectroscopy systems.

13.
Opt Lett ; 38(13): 2165-7, 2013 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-23811865

RESUMO

We report on the first microsecond doubly resonant optical parametric oscillator (OPO). It is based on a nested cavity OPO architecture allowing single longitudinal mode operation and low oscillation threshold (few microjoule). The combination with a master oscillator-power amplifier fiber pump laser provides a versatile optical source widely tunable in the 3.3-3.5 µm range with an adjustable pulse repetition rate (from 40 to 100 kHz), high duty cycle (~10(-2)) and mean power (up to 25 mW in the idler beam). The potential for trace gas sensing applications is demonstrated through photoacoustic detection of atmospheric methane.

14.
Opt Lett ; 36(5): 751-3, 2011 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-21368971

RESUMO

We report on a nonlinear mirror (NLM) scheme that enables, for the first time to the best of our best knowledge, tunable mode locking of a Cr2+:ZnSe laser in the picosecond regime. The NLM-used as the output coupler of the laser cavity-consists of a periodically poled lithium niobate (PPLN) crystal with a fan-out grating coupled with a dichroic mirror and a wedged dispersive YAG plate. The Cr2+:ZnSe laser, pumped by a CW thulium-doped fiber laser, delivers 85 ps pulses at a repetition rate of 220 MHz with a 300 mW average power. Thanks to the use of a fan-out PPLN crystal, we benefit from the wide tunability of the Cr2+:ZnSe laser and achieve mode locking over the whole 2.44-2.55 µm range while maintaining a narrow-linewidth emission suitable for time-resolved nonlinear spectroscopy applications.

15.
J Clin Periodontol ; 38(12): 1099-105, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22092542

RESUMO

AIM: Because patient adherence to oral hygiene is essential for periodontal treatment success, the aim of the study was to assess whether a motivational interview addressing the five dimensions of Leventhal's theory performed better than conventional basic instruction on improving compliance with plaque control among patients with periodontitis. MATERIALS AND METHODS: A randomized controlled clinical trial design was used in which a group of patients underwent a motivational interview in addition to classical consultation. A control group received only the standard consultation. The O'Leary Plaque Index was used to judge the oral hygiene at baseline and at 1 month follow-up. Patient satisfaction with the dental visit was scored using a specific questionnaire. RESULTS: At baseline, the mean full mouth plaque score varied between 55% (experimental group) and 58% (control group). Patients in the experimental group had a higher oral hygiene improvement (21 ± 20% versus 4 ± 5%, p < 0.001) 1 month post-treatment. The motivational interview resulted in greater satisfaction scores compared with those of patients in the control group: 10.55 ± 1.53 versus 8.82 ± 2.40, p = 0.014. CONCLUSIONS: This new concept of motivational interview is a promising approach and can be useful for counselling-related periodontal disorders.


Assuntos
Terapia Comportamental/métodos , Motivação , Higiene Bucal/psicologia , Cooperação do Paciente/psicologia , Controles Informais da Sociedade , Adulto , Análise de Variância , Feminino , Humanos , Entrevista Psicológica , Masculino , Pessoa de Meia-Idade , Higiene Bucal/métodos , Índice Periodontal , Teoria Psicológica , Autocuidado , Resultado do Tratamento
16.
Opt Express ; 18(19): 20401-8, 2010 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-20940932

RESUMO

We study the photon correlation properties of broadband parametric down-converted light. The measurement of the photon correlation is carried out thanks to a modified Hanbury Brown-Twiss interferometer based on two photon absorption in GaAs detector. Since this method is not affected by the phase matching conditions of the detecting apparatus (so called "final state post-selection"), the detection bandwidth can be extremely large. This is illustrated by studying, with the same apparatus, the degree of second order coherence of parametric light in both degenerate and non-degenerate cases. We show that our experiment is able to determine the coherent as well as the incoherent contributions to the degree of second order coherence of parametric light with a time resolution in the fs range scale.


Assuntos
Interferometria/instrumentação , Fotometria/instrumentação , Semicondutores , Espectrometria de Fluorescência/instrumentação , Desenho de Equipamento/instrumentação , Análise de Falha de Equipamento/instrumentação , Luz , Fótons
17.
Opt Lett ; 35(13): 2197-9, 2010 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-20596192

RESUMO

We report on the experimental operation of a picosecond, singly resonant, synchronously pumped optical parametric oscillator (SPOPO) based on a ZnGeP(2) (ZGP) crystal. The ZGP SPOPO is pumped with the idler radiation from a diffraction-grating-tuned periodically poled lithium niobate SPOPO emitting a continuous picosecond pulse train (Delta tau approximately 8 ps, f=76 MHz). The noncritically 90 degree phase-matched ZGP SPOPO is tuned in the 3.8-5.6 microm range by tuning the pump wavelength (2.25-2.5 microm). As high as approximately 800 mW of average power is emitted at 4 microm.

18.
Opt Lett ; 35(21): 3667-9, 2010 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-21042385

RESUMO

We report on the investigation of thermal effects in high-repetition-rate pulsed optical parametric oscillators emitting in the mid-IR. We find that the thermal load induced by the nonresonant idler absorption plays a critical role in the emergence of thermally induced bistability. We then demonstrate a significant improvement of the conversion efficiency (more than 30%) when a proper axial temperature gradient is applied to the nonlinear crystal by use of a two-zone temperature-controlled oven.

19.
Opt Express ; 16(22): 18457-78, 2008 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-18958125

RESUMO

Fresnel phase matching is a convenient and universal way to phase match nonlinear three-wave mixing by total internal reflection in isotropic materials like common semiconductors. This technique makes use of the large relative phase lag between the interacting waves at total internal reflection, and was suggested by the nonlinear optics pioneers in the 70's; it has been worked out by several teams since then but, quite unexpectedly, has never succeeded in producing enough parametric gain to achieve optical parametric oscillation. We show that this failure stems mostly from a basic law of nonlinear reflection, which leads to a spatial walk-off between the pump and the generated parametric waves, resulting in unexpected destructive interference patterns between the waves while bouncing back and forth between the interfaces. Ray tracing or plane wave analysis gives an incomplete representation of the phenomenon while highly multimodal nonlinear guided wave theory reconciles the different views. Very good agreement between the presented theory and experiments is demonstrated in gallium arsenide samples.

20.
Opt Lett ; 34(13): 2069-71, 2009 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-19572002

RESUMO

We report on a 2.05 microm nanosecond master oscillator power amplifier optical parametric source for CO2 differential-absorption lidar. The master oscillator consists of an entangled-cavity nanosecond optical parametric oscillator based on a type II periodically poled lithium niobate crystal that provides highly stable single-longitudinal-mode radiation. The signal emission is amplified by a multistage parametric amplifier to generate up to 11 mJ in a nearly diffraction-limited beam with an M2 quality factor of approximately 1.5 while maintaining single-longitudinal-mode emission with a frequency stability better than 3 MHz rms. This approach can be readily applied to the detection of various greenhouse gases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA