Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Nutr ; 39(7): 2227-2232, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31668722

RESUMO

BACKGROUND AND AIMS: Computed tomography (CT)-based measurement of skeletal muscle cross-sectional area (CSA) and Hounsfield unit (HU) radiodensity are used to assess the presence of sarcopenia and myosteatosis, respectively. The validated CT-based technique involves analysis of skeletal muscle at the third lumbar vertebral (L3) level. Recently there has been increasing interest in the use of psoas muscle alone as a sentinel. However, this technique has not been extensively investigated or compared with the previous validated standard approach. METHODS: Portovenous phase CT images at the L3 level were identified retrospectively from a single institution in 150 patients who had non-emergency scans and were analysed by a single assessor using SliceOmatic software v5.0 (TomoVision, Canada). Manual segmentation based upon validated HU thresholds for skeletal muscle density was performed for all skeletal muscle, as well as the individual muscle groups. The muscle CSA and mean radiodensity of each group were compared against the whole L3 slice values. RESULTS: When compared with whole L3 slice CSA, anterior abdominal wall CSA had the strongest correlation (r = 0.9315, p < 0.0001) followed by paravertebral (r = 0.8948, p < 0.0001), then psoas muscle (r = 0.7041, p < 0.0001). The mean ± SD density of the psoas muscle (42 ± 8.4 HU) was significantly higher than the whole slice radiodensity (32.3 ± 9.5 HU, p < 0.0001), with paravertebral radiodensity being a more accurate estimation (34.5 ± 10.8 HU). There was a significant difference in the prevalence of myosteatosis when the density measured from the psoas was compared with that of the whole L3 skeletal muscle (27.7% vs. 66.0%, p < 0.0001). CONCLUSION: Whole L3 slice CSA correlated positively with psoas muscle CSA but was subject to wide variability in results. Psoas muscle radiodensity was significantly greater than whole L3 slice density and resulted in underestimation of the prevalence of myosteatosis. Given the lack of equivalence from individual muscle groups, we recommend that further work be undertaken to investigate which muscle group, or indeed whether the gold standard of whole L3 skeletal muscle, provides the best correlation with clinical outcomes.


Assuntos
Composição Corporal , Músculos Psoas/diagnóstico por imagem , Sarcopenia/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adiposidade , Idoso , Feminino , Humanos , Vértebras Lombares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Músculos Psoas/fisiopatologia , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sarcopenia/epidemiologia , Sarcopenia/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA