1.
J Appl Clin Med Phys ; 23(3): e13452, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35166011

RESUMO

Secondary external dose calculations for a 0.35 T magnetic resonance image-guided radiation therapy (MRgRT) are needed within the radiation oncology community to follow safety standards set forth within the field. We evaluate the commercially available software, RadCalc, in its ability to accurately perform monitor unit dose calculations within a magnetic field. We also evaluate the potential effects of a 0.35 T magnetic field upon point dose calculations. Monitor unit calculations were evaluated with (wMag) and without (noMag) a magnetic field considerations in RadCalc for the ViewRay MRIdian. The magnetic field is indirectly accounted for by using asymmetric profiles for calculation. The introduction of double-stacked multi-leaf collimator leaves was also included in the monitor unit calculations and a single transmission value was determined. A suite of simple and complex geometries with a variety field arrangements were calculated for each method to demonstrate the effect of the 0.35 T magnetic field on monitor unit calculations. Finally, 25 patient-specific treatment plans were calculated using each method for comparison. All simple geometries calculated in RadCalc were within 2% of treatment planning system (TPS) values for both methods, except for a single noMag off-axis comparison. All complex muilt-leaf collimator (MLC) pattern calculations were within 5%. All complex phantom geometry calculations were within 5% except for a single field within a lung phantom at a distal point. For the patient calculations, the noMag method average percentage difference was 0.09 ± 2.5% and the wMag average percentage difference was 0.08 ± 2.5%. All results were within 5% for the wMag method. We performed monitor unit calculations for a 0.35 T MRgRT system using a commercially available secondary monitor unit dose calculation software and demonstrated minimal impact of the 0.35 T magnetic field on monitor unit dose calculations. This is the first investigation demonstrating successful calculations of dose using RadCalc in the low-field 0.35 T ViewRay MRIdian system.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Humanos , Aceleradores de Partículas , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Software
2.
J Appl Clin Med Phys ; 21(12): 20-26, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33211375

RESUMO

Radiotherapy components of an magnetic resonnace-guided radiotherapy (MRgRT) system can alter the magnetic fields, causing spatial distortion and image deformation, altering imaging and radiation isocenter coincidence and the accuracy of dose calculations. This work presents a characterization of radiotherapy component impact on MR imaging quality in terms of imaging isocenter variation and spatial integrity changes on a 0.35T MRgRT system, pre- and postupgrade of the system. The impact of gantry position, MLC field size, and treatment table power state on imaging isocenter and spatial integrity were investigated. A spatial integrity phantom was used for all tests. Images were acquired for gantry angles 0-330° at 30° increments to assess the impact of gantry position. For MLC and table power state tests all images were acquired at the home gantry position (330°). MLC field sizes ranged from 1.66 to 27.4 cm edge length square fields. Imaging isocenter shift caused by gantry position was reduced from 1.7 mm at gantry 150° preupgrade to 0.9 mm at gantry 120° postupgrade. Maximum spatial integrity errors were 0.5 mm or less pre- and postupgrade for all gantry angles, MLC field sizes, and treatment table power states. However, when the treatment table was powered on, there was significant reduction in SNR. This study showed that gantry position can impact imaging isocenter, but spatial integrity errors were not dependent on gantry position, MLC field size, or treatment table power state. Significant isocenter variation, while reduced postupgrade, is cause for further investigation.


Assuntos
Imageamento por Ressonância Magnética , Aceleradores de Partículas , Humanos , Campos Magnéticos , Imagens de Fantasmas
3.
J Appl Clin Med Phys ; 20(10): 53-66, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31541542

RESUMO

PURPOSE: To present lessons learned from magnetic resonance imaging (MRI) quality control (QC) tests for low-field MRI-guided radiation therapy (MR-IGRT) systems. METHODS: MRI QC programs were established for low-field MRI-60 Co and MRI-Linac systems. A retrospective analysis of MRI subsystem performance covered system commissioning, operations, maintenance, and quality control. Performance issues were classified into three groups: (a) Image noise and artifact; (b) Magnetic field homogeneity and linearity; and (c) System reliability and stability. RESULTS: Image noise and artifacts were attributed to room noise sources, unsatisfactory system cabling, and broken RF receiver coils. Gantry angle-dependent magnetic field inhomogeneities were more prominent on the MRI-Linac due to the high volume of steel shielding in the gantry. B0 inhomogeneities measured in a 24-cm spherical phantom were <5 ppm for both MR-IGRT systems after using MRI gradient offset (MRI-GO) compensation on the MRI-Linac. However, significant signal dephasing occurred on the MRI-Linac while the gantry was rotating. Spatial integrity measurements were sensitive to gradient calibration and vulnerable to shimming. The most common causes of MR-IGRT system interruptions were software disconnects between the MRI and radiation therapy delivery subsystems caused by patient table, gantry, and multi-leaf collimator (MLC) faults. The standard deviation (SD) of the receiver coil signal-to-noise ratio was 1.83 for the MRI-60 Co and 1.53 for the MRI-Linac. The SD of the deviation from the mean for the Larmor frequency was 1.41 ppm for the MRI-60 Co and 1.54 ppm for the MRI-Linac. The SD of the deviation from the mean for the transmitter reference amplitude was 0.90% for the MRI-60 Co and 1.68% for the MRI-Linac. High SDs in image stability data corresponded to reports of spike noise. CONCLUSIONS: There are significant technological challenges associated with implementing and maintaining MR-IGRT systems. Most of the performance issues were identified and resolved during commissioning.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Controle de Qualidade , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Artefatos , Radioisótopos de Cobalto , Humanos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Razão Sinal-Ruído , Software
4.
J Appl Clin Med Phys ; 18(1): 128-138, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28291913

RESUMO

MOTIVATION: In this study, a method is reported to perform IMRT and VMAT treatment delivery verification using 3D volumetric primary beam fluences reconstructed directly from planned beam parameters and treatment delivery records. The goals of this paper are to demonstrate that 1) 3D beam fluences can be reconstructed efficiently, 2) quality assurance (QA) based on the reconstructed 3D fluences is capable of detecting additional treatment delivery errors, particularly for VMAT plans, beyond those identifiable by other existing treatment delivery verification methods, and 3) QA results based on 3D fluence calculation (3DFC) are correlated with QA results based on physical phantom measurements and radiation dose recalculations. METHODS: Using beam parameters extracted from DICOM plan files and treatment delivery log files, 3D volumetric primary fluences are reconstructed by forward-projecting the beam apertures, defined by the MLC leaf positions and modulated by beam MU values, at all gantry angles using first-order ray tracing. Treatment delivery verifications are performed by comparing 3D fluences reconstructed using beam parameters in delivery log files against those reconstructed from treatment plans. Passing rates are then determined using both voxel intensity differences and a 3D gamma analysis. QA sensitivity to various sources of errors is defined as the observed differences in passing rates. Correlations between passing rates obtained from QA derived from both 3D fluence calculations and physical measurements are investigated prospectively using 20 clinical treatment plans with artificially introduced machine delivery errors. RESULTS: Studies with artificially introduced errors show that common treatment delivery problems including gantry angle errors, MU errors, jaw position errors, collimator rotation errors, and MLC leaf position errors were detectable at less than normal machine tolerances. The reported 3DFC QA method has greater sensitivity than measurement-based QA methods. Statistical analysis-based Spearman's correlations shows that the 3DFC QA passing rates are significantly correlated with passing rates of physical phantom measurement-based QA methods. CONCLUSION: Among measurement-less treatment delivery verification methods, the reported 3DFC method is less demanding than those based on full dose re-calculations, and more comprehensive than those that solely checks beam parameters in treatment log files. With QA passing rates correlating to measurement-based passing rates, the 3DFC QA results could be useful for complementing the physical phantom measurements, or verifying treatment deliveries when physical measurements are not available. For the past 4+ years, the reported method has been implemented at authors' institution 1) as a complementary metric to physical phantom measurements for pretreatment, patient-specific QA of IMRT and VMAT plans, and 2) as an important part of the log file-based automated verification of daily patient treatment deliveries. It has been demonstrated to be useful in catching both treatment plan data transfer errors and treatment delivery problems.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/radioterapia , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Software , Humanos , Método de Monte Carlo , Aceleradores de Partículas , Controle de Qualidade , Dosagem Radioterapêutica
5.
Acta Oncol ; 54(9): 1474-82, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26206517

RESUMO

BACKGROUND: Onboard magnetic resonance imaging (OB-MRI) for daily localization and adaptive radiotherapy has been under development by several groups. However, no clinical studies have evaluated whether OB-MRI improves visualization of the target and organs at risk (OARs) compared to standard onboard computed tomography (OB-CT). This study compared visualization of patient anatomy on images acquired on the MRI-(60)Co ViewRay system to those acquired with OB-CT. MATERIAL AND METHODS: Fourteen patients enrolled on a protocol approved by the Institutional Review Board (IRB) and undergoing image-guided radiotherapy for cancer in the thorax (n = 2), pelvis (n = 6), abdomen (n = 3) or head and neck (n = 3) were imaged with OB-MRI and OB-CT. For each of the 14 patients, the OB-MRI and OB-CT datasets were displayed side-by-side and independently reviewed by three radiation oncologists. Each physician was asked to evaluate which dataset offered better visualization of the target and OARs. A quantitative contouring study was performed on two abdominal patients to assess if OB-MRI could offer improved inter-observer segmentation agreement for adaptive planning. RESULTS: In total 221 OARs and 10 targets were compared for visualization on OB-MRI and OB-CT by each of the three physicians. The majority of physicians (two or more) evaluated visualization on MRI as better for 71% of structures, worse for 10% of structures, and equivalent for 14% of structures. 5% of structures were not visible on either. Physicians agreed unanimously for 74% and in majority for > 99% of structures. Targets were better visualized on MRI in 4/10 cases, and never on OB-CT. CONCLUSION: Low-field MR provides better anatomic visualization of many radiotherapy targets and most OARs as compared to OB-CT. Further studies with OB-MRI should be pursued.


Assuntos
Imageamento por Ressonância Magnética , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada por Raios X , Neoplasias Abdominais/patologia , Neoplasias Abdominais/radioterapia , Neoplasias de Cabeça e Pescoço/patologia , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Variações Dependentes do Observador , Neoplasias Pélvicas/patologia , Neoplasias Pélvicas/radioterapia , Neoplasias Torácicas/patologia , Neoplasias Torácicas/radioterapia
6.
Clin Transl Radiat Oncol ; 41: 100627, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37441543

RESUMO

Purpose: Magnetic resonance-guided stereotactic body radiation therapy (MRgSBRT) with optional online adaptation has shown promise in delivering ablative doses to unresectable primary liver cancer. However, there remain limited data on the indications for online adaptation as well as dosimetric and longer-term clinical outcomes following MRgSBRT. Methods and Materials: Patients with unresectable hepatocellular carcinoma (HCC), cholangiocarcinoma (CCA), and combined biphenotypic hepatocellular-cholangiocarcinoma (cHCC-CCA) who completed MRgSBRT to 50 Gy in 5 fractions between June of 2015 and December of 2021 were analyzed. The necessity of adaptive techniques was evaluated. The cumulative incidence of local progression was evaluated and survival and competing risk analyses were performed. Results: Ninety-nine analyzable patients completed MRgSBRT during the study period and 54 % had planning target volumes (PTVs) within 1 cm of the duodenum, small bowel, or stomach at the time of simulation. Online adaptive RT was used in 53 % of patients to correct organ-at-risk constraint violation and/or to improve target coverage. In patients who underwent adaptive RT planning, online replanning resulted in superior target coverage when compared to projected, non-adaptive plans (median coverage ≥ 95 % at 47.5 Gy: 91 % [IQR: 82-96] before adaptation vs 95 % [IQR: 87-99] after adaptation, p < 0.01). The median follow-up for surviving patients was 34.2 months for patients with HCC and 10.1 months for patients with CCA/cHCC-CCA. For all patients, the 2-year cumulative incidence of local progression was 9.8 % (95 % CI: 1.5-18 %) for patients with HCC and 9.0 % (95 % CI: 0.1-18) for patients with CCA/cHCC-CCA. Grade 3 through 5 acute and late clinical gastrointestinal toxicities were observed in < 10 % of the patients. Conclusions: MRgSBRT, with the option for online adaptive planning when merited, allows delivery of ablative doses to primary liver tumors with excellent local control with acceptable toxicities. Additional studies evaluating the efficacy and safety of MRgSBRT in the treatment of primary liver cancer are warranted.

7.
Int J Radiat Oncol Biol Phys ; 115(1): 214-223, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-35878713

RESUMO

PURPOSE: Ablative radiation therapy for borderline resectable or locally advanced pancreatic ductal adenocarcinoma (BR/LA-PDAC) may limit concurrent chemotherapy dosing and usually is only safely deliverable to tumors distant from gastrointestinal organs. Magnetic resonance guided radiation therapy may safely permit radiation and chemotherapy dose escalation. METHODS AND MATERIALS: We conducted a single-arm phase I study to determine the maximum tolerated dose of ablative hypofractionated radiation with full-dose gemcitabine/nab-paclitaxel in patients with BR/LA-PDAC. Patients were treated with gemcitabine/nab-paclitaxel (1000/125 mg/m2) x 1c then concurrent gemcitabine/nab-paclitaxel and radiation. Gemcitabine/nab-paclitaxel and radiation doses were escalated per time-to-event continual reassessment method from 40 to 45 Gy 25 fxs with chemotherapy (600-800/75 mg/m2) to 60 to 67.5 Gy/15 fractions and concurrent gemcitabine/nab-paclitaxel (1000/100 mg/m2). The primary endpoint was maximum tolerated dose of radiation as defined by 60-day dose limiting toxicity (DLT). DLT was treatment-related G5, G4 hematologic, or G3 gastrointestinal requiring hospitalization >3 days. Secondary endpoints included resection rates, local progression free survival (LPFS), distant metastasis free survival (DMFS), and overall survival (OS). RESULTS: Thirty patients enrolled (March 2015-February 2019), with 26 evaluable patients (2 progressed before radiation, 1 was determined ineligible for radiation during planning, 1 withdrew consent). One DLT was observed. The DLT rate was 14.1% (3.3%-24.9%) with a maximum tolerated dose of gemcitabine/nab-paclitaxel (1000/100 mg/m2) and 67.5 Gy/15 fractions. At a median follow-up of 40.6 months for living patients the median OS was 14.5 months (95% confidence interval [CI], 10.9-28.2 months). The median OS for patients with Eastern Collaborative Oncology Group 0 and carbohydrate antigen 19-9 <90 were 34.1 (95% CI, 13.6-54.1) and 43.0 (95% CI, 8.0-not reached) months, respectively. Two-year LPFS and DMFS were 85% (95% CI, 63%-94%) and 57% (95% CI, 34%-73%), respectively. CONCLUSIONS: Full-dose gemcitabine/nab-paclitaxel with ablative magnetic resonance guided radiation therapy dosing is safe in patients with BR/LA-PDAC, with promising LPFS and DMFS.


Assuntos
Adenocarcinoma , Neoplasias Pancreáticas , Humanos , Adenocarcinoma/radioterapia , Adenocarcinoma/tratamento farmacológico , Albuminas , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Gencitabina , Paclitaxel , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/tratamento farmacológico , Neoplasias Pancreáticas
8.
Pract Radiat Oncol ; 12(1): e49-e55, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34464743

RESUMO

During the last decade, radiation oncology departments have integrated magnetic resonance imaging (MRI) equipment, procedures, and expertise into their practices. MRI safety is an important consideration because a large percentage of patients receiving radiation therapy have histories of multiple surgeries and implanted devices. However, MRI safety guidelines and workflows were traditionally designed for radiology departments. This report presents an MR safety program designed for a radiation oncology department to address its specific needs.


Assuntos
Radioterapia (Especialidade) , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
9.
Int J Radiat Oncol Biol Phys ; 112(2): 379-389, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34474109

RESUMO

PURPOSE: Stereotactic body radiation therapy is increasingly used to treat a variety of oligometastatic histologies, but few data exist for ovarian cancer. Ablative stereotactic body radiation therapy dosing is challenging in sites like the abdomen, pelvis, and central thorax due to proximity and motion of organs at risk. A novel radiation delivery method, stereotactic magnetic-resonance-guided online-adaptive radiation therapy (SMART), may improve the therapeutic index of stereotactic body radiation therapy through enhanced soft-tissue visualization, real-time nonionizing imaging, and ability to adapt to the anatomy-of-the-day, with the goal of producing systemic-therapy-free intervals. This phase I trial assessed feasibility, safety, and dosimetric advantage of SMART to treat ovarian oligometastases. METHODS AND MATERIALS: Ten patients with recurrent oligometastatic ovarian cancer underwent SMART for oligometastasis ablation. Initial plans prescribed 35 Gy/5 fractions with goal 95% planning target volume coverage by 95% of prescription, with dose escalation permitted, subject to strict organ-at-risk dose constraints. Daily adaptive planning was used to protect organs-at-risk and/or increase target dose. Feasibility (successful delivery of >80% of fractions in the first on-table attempt) and safety of this approach was evaluated, in addition to efficacy, survival metrics, quality-of-life, prospective timing and dosimetric outcomes. RESULTS: Ten women with seventeen ovarian oligometastases were treated with SMART, and 100% of treatment fractions were successfully delivered. Online adaptive plans were selected at time of treatment for 58% of fractions, due to initial plan violation of organs-at-risk constraints (84% of adapted fractions) or observed opportunity for planning target volume dose escalation (16% of adapted fractions), with a median on-table time of 64 minutes. A single Grade ≥3 acute (within 6 months of SMART) treatment-related toxicity (duodenal ulcer) was observed. Local control at 3 months was 94%; median progression-free survival was 10.9 months. Median Kaplan-Meier estimated systemic-therapy-free survival after radiation completion was 11.5 months, with concomitant quality-of-life improvements. CONCLUSIONS: SMART is feasible and safe for high-dose radiation therapy ablation of ovarian oligometastases of the abdomen, pelvis, and central thorax with minimal toxicity, high rates of local control, and prolonged systemic-therapy-free survival translating into improved quality-of-life.


Assuntos
Neoplasias Ovarianas , Radiocirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Ovarianas/radioterapia , Estudos Prospectivos , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
10.
Radiother Oncol ; 164: 275-281, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34624406

RESUMO

INTRODUCTION: Accelerated partial breast irradiation (APBI) seeks to reduce irradiated volumes and radiation exposure for patients while maintaining acceptable clinical outcomes. Magnetic resonance image-guided radiotherapy (MRgRT) provides excellent soft-tissue contrast for treatment localization, which can reduce setup uncertainty, thus reducing margins in the external beam setting. Additionally, stereotactic body radiotherapy (SBRT)-style regimens with high gradients can also be executed. This MR-guided stereotactic APBI (MRgS-APBI) approach can be utilized for a lower number of fractions and spare a greater volume of healthy tissues compared to conventional 3D external beam APBI. METHODS: Our MRgS-APBI program was developed for two prospective non-randomized phase I/II clinical trials (20Gyx1 and 8.5Gyx3). Both breast SBRT treatment planning and MRgRT delivery techniques were described in this study. Simulation included both CT and MRI with specialized immobilization to accommodate MR-guided setup and cine-MRI treatment gating. Dosimetry data from 48 single-fraction and 19 three-fraction patients were collected and evaluated. This included planning objectives and SBRT-specific indices. During treatment, setup errors were calculated to evaluate setup reproducibility and duty cycle was calculated using cine-MRI data during gated delivery. RESULTS: In both the single- and three- fraction trials combined, 88.5% of the possible dosimetric objectives across all patients were met during planning. The majority of the planning objectives were easily achievable indicating the potential for stricter objectives for subsequent S-APBI treatments. The average magnitude of setup uncertainties was 1.0 cm ±â€¯0.6 cm across all treatments. In the three-fraction trial, the average beam-on duty-cycle for the MRI-gated delivery was 83.0 ±â€¯13.0%. There were no technical MRgS-APBI related issues that resulted in discontinuation of treatment across all patients. CONCLUSION: SBRT-style dosimetry and delivery for APBI is feasible using MR-guidance. The program development and dosimetric outcomes reported here can serve as a guide for other institutions considering the clinical implementation of MR-guided stereotactic APBI.


Assuntos
Neoplasias da Mama , Planejamento da Radioterapia Assistida por Computador , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Feminino , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Estudos Prospectivos , Reprodutibilidade dos Testes
11.
Front Oncol ; 11: 617681, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33777759

RESUMO

Curative-intent radiotherapy plays an integral role in the treatment of lung cancer and therefore improving its therapeutic index is vital. MR guided radiotherapy (MRgRT) systems are the latest technological advance which may help with achieving this aim. The majority of MRgRT treatments delivered to date have been stereotactic body radiation therapy (SBRT) based and include the treatment of (ultra-) central tumors. However, there is a move to also implement MRgRT as curative-intent treatment for patients with inoperable locally advanced NSCLC. This paper presents the initial clinical experience of using the two commercially available systems to date: the ViewRay MRIdian and Elekta Unity. The challenges and potential solutions associated with MRgRT in lung cancer will also be highlighted.

12.
Med Phys ; 48(8): 4523-4531, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34231224

RESUMO

The past decade has seen the increasing integration of magnetic resonance (MR) imaging into radiation therapy (RT). This growth can be contributed to multiple factors, including hardware and software advances that have allowed the acquisition of high-resolution volumetric data of RT patients in their treatment position (also known as MR simulation) and the development of methods to image and quantify tissue function and response to therapy. More recently, the advent of MR-guided radiation therapy (MRgRT) - achieved through the integration of MR imaging systems and linear accelerators - has further accelerated this trend. As MR imaging in RT techniques and technologies, such as MRgRT, gain regulatory approval worldwide, these systems will begin to propagate beyond tertiary care academic medical centers and into more community-based health systems and hospitals, creating new opportunities to provide advanced treatment options to a broader patient population. Accompanying these opportunities are unique challenges related to their adaptation, adoption, and use including modification of hardware and software to meet the unique and distinct demands of MR imaging in RT, the need for standardization of imaging techniques and protocols, education of the broader RT community (particularly in regards to MR safety) as well as the need to continue and support research, and development in this space. In response to this, an ad hoc committee of the American Association of Physicists in Medicine (AAPM) was formed to identify the unmet needs, roadblocks, and opportunities within this space. The purpose of this document is to report on the major findings and recommendations identified. Importantly, the provided recommendations represent the consensus opinions of the committee's membership, which were submitted in the committee's report to the AAPM Board of Directors. In addition, AAPM ad hoc committee reports differ from AAPM task group reports in that ad hoc committee reports are neither reviewed nor ultimately approved by the committee's parent groups, including at the council and executive committee level. Thus, the recommendations given in this summary should not be construed as being endorsed by or official recommendations from the AAPM.


Assuntos
Imageamento por Ressonância Magnética , Radioterapia Guiada por Imagem , Humanos , Aceleradores de Partículas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estados Unidos
13.
Semin Radiat Oncol ; 29(3): 219-227, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31027639

RESUMO

Adaptive radiotherapy emerged over 20 years ago and is now an established clinical practice in a number of organ sites. No one solution for adaptive therapy exists. Rather, adaptive radiotherapy is a process which combines multiple tools for imaging, assessment of need for adaptation, treatment planning, and quality assurance of this process. Workflow is therefore a critical aspect to ensure safe, effective, and efficient implementation of adaptive radiotherapy. In this work, we discuss the tools for online and offline adaptive radiotherapy and introduce workflow concepts for these types of adaptive radiotherapy. Common themes and differences between the workflows are introduced and controversies and areas of active research are discussed.


Assuntos
Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Fluxo de Trabalho , Humanos , Processamento de Imagem Assistida por Computador/métodos , Posicionamento do Paciente , Dosagem Radioterapêutica
14.
Med Phys ; 46(9): 4135-4147, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31309586

RESUMO

PURPOSE: The superior soft-tissue contrast achieved using magnetic resonance imaging (MRI) compared to x-ray computed tomography (CT) has led to the popularization of MRI-guided radiation therapy (MR-IGRT), especially in recent years with the advent of first and second generation MRI-based therapy delivery systems for MR-IGRT. The expanding use of these systems is driving interest in MRI-only RT workflows in which MRI is the sole imaging modality used for treatment planning and dose calculations. To enable such a workflow, synthetic CT (sCT) data must be generated based on a patient's MRI data so that dose calculations may be performed using the electron density information derived from CT images. In this study, we propose a novel deep spatial pyramid convolutional framework for the MRI-to-CT image-to-image translation task and compare its performance to the well established U-Net architecture in a generative adversarial network (GAN) framework. METHODS: Our proposed framework utilizes atrous convolution in a method named atrous spatial pyramid pooling (ASPP) to significantly reduce the total number of parameters required to describe the model while effectively capturing rich, multi-scale structural information in a manner that is not possible in the conventional framework. The proposed framework consists of a generative model composed of stacked encoders and decoders separated by the ASPP module, where atrous convolution is applied at increasing rates in parallel to encode large-scale features. The performance of the proposed method is compared to that of the conventional GAN framework in terms of the time required to train the model and the image quality of the generated sCT as measured by the root mean square error (RMSE), structural similarity index (SSIM), and peak signal-to-noise ratio (PSNR) depending on the size of the training data set. Dose calculations based on sCT data generated using the proposed architecture are also compared to clinical plans to evaluate the dosimetric accuracy of the method. RESULTS: Significant reductions in training time and improvements in image quality are observed at every training data set size when the proposed framework is adopted instead of the conventional framework. Over 1042 test images, values of 17.7 ± 4.3 HU, 0.9995 ± 0.0003, and 71.7 ± 2.3 are observed for the RMSE, SSIM, and PSNR metrics, respectively. Dose distributions calculated based on sCT data generated using the proposed framework demonstrate passing rates equal to or greater than 98% using the 3D gamma index with a 2%/2 mm criterion. CONCLUSIONS: The deep spatial pyramid convolutional framework proposed here demonstrates improved performance compared to the conventional GAN framework that has been applied to the image-to-image translation task of sCT generation. Adopting the method is a first step toward an MRI-only RT workflow that enables widespread clinical applications for MR-IGRT including online adaptive therapy.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Aprendizado Profundo , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Radioterapia Guiada por Imagem , Tomografia Computadorizada por Raios X , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
15.
Pract Radiat Oncol ; 9(4): 274-279, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30790716

RESUMO

Magnetic resonance imaging (MRI) guided radiation therapy is reported for the first time in a patient with an implantable cardioverter defibrillator (ICD) and cardiac fibroma in the left ventricle. Stereotactic body radiation therapy was delivered in 5 fractions at a dose of 700 cGy/fraction using a 0.35 T MRI-linear accelerator with real-time tumor tracking and beam gating. The average treatment time per fraction was 12.13 minutes, including gating dead time and gantry rotation, and the average duty cycle was 56.8%. Lessons learned included the need for MRI safety workflows that address the ICD and are tailored to the radiation oncology environment, selection of a suitable tracking target to ensure satisfactory duty cycle, and the presence of null band artifacts within the tracking target caused by ferrous components in the ICD.


Assuntos
Desfibriladores Implantáveis/normas , Coração/efeitos da radiação , Imageamento por Ressonância Magnética/métodos , Humanos , Masculino , Pessoa de Meia-Idade
16.
Adv Radiat Oncol ; 4(1): 201-209, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30706029

RESUMO

PURPOSE: Stereotactic body radiation therapy (SBRT) is an effective treatment for oligometastatic or unresectable primary malignancies, although target proximity to organs at risk (OARs) within the ultracentral thorax (UCT) limits safe delivery of an ablative dose. Stereotactic magnetic resonance (MR)-guided online adaptive radiation therapy (SMART) may improve the therapeutic ratio using reoptimization to account for daily variation in target and OAR anatomy. This study assessed the feasibility of UCT SMART and characterized dosimetric and clinical outcomes in patients treated for UCT lesions on a prospective phase 1 trial. METHODS AND MATERIALS: Five patients with oligometastatic (n = 4) or unresectable primary (n = 1) UCT malignancies underwent SMART. Initial plans prescribed 50 Gy in 5 fractions with goal 95% planning target volume (PTV) coverage by 95% of prescription, subject to strict OAR constraints. Daily real-time online adaptive plans were created as needed to preserve hard OAR constraints, escalate PTV dose, or both, based on daily setup MR image set anatomy. Treatment times, patient outcomes, and dosimetric comparisons were prospectively recorded. RESULTS: All initial and daily adaptive plans met strict OAR constraints based on simulation and daily setup MR imaging anatomy, respectively. Four of the 5 patients received ≥1 adapted fraction. Ten of the 25 total delivered fractions were adapted. A total of 30% of plan adaptations were performed to improve PTV coverage; 70% were for reversal of ≥1 OAR violation. Local control by Response Evaluation Criteria in Solid Tumors was 100% at 3 and 6 months. No grade ≥3 acute (within 6 months of radiation completion) treatment-related toxicities were identified. CONCLUSIONS: SMART may allow PTV coverage improvement and/or OAR sparing compared with nonadaptive SBRT and may widen the therapeutic index of UCT SBRT. In this small prospective cohort, we found that SMART was clinically deliverable to 100% of patients, although treatment delivery times surpassed our predefined, timing-based feasibility endpoint. This technique is well tolerated, offering excellent local control with no identified acute grade ≥3 toxicity.

17.
Adv Radiat Oncol ; 4(1): 142-149, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30706022

RESUMO

PURPOSE: Daily magnetic resonance (MR)-guided radiation has the potential to improve stereotactic body radiation therapy (SBRT) for tumors of the liver. Magnetic resonance imaging (MRI) introduces unique variables that are untested clinically: electron return effect, MRI geometric distortion, MRI to radiation therapy isocenter uncertainty, multileaf collimator position error, and uncertainties with voxel size and tracking. All could lead to increased toxicity and/or local recurrences with SBRT. In this multi-institutional study, we hypothesized that direct visualization provided by MR guidance could allow the use of small treatment volumes to spare normal tissues while maintaining clinical outcomes despite the aforementioned uncertainties in MR-guided treatment. METHODS AND MATERIALS: Patients with primary liver tumors or metastatic lesions treated with MR-guided liver SBRT were reviewed at 3 institutions. Toxicity was assessed using National Cancer Institute Common Terminology Criteria for Adverse Events Version 4. Freedom from local progression (FFLP) and overall survival were analyzed with the Kaplan-Meier method and χ2 test. RESULTS: The study population consisted of 26 patients: 6 hepatocellular carcinomas, 2 cholangiocarcinomas, and 18 metastatic liver lesions (44% colorectal metastasis). The median follow-up was 21.2 months. The median dose delivered was 50 Gy at 10 Gy/fraction. No grade 4 or greater gastrointestinal toxicities were observed after treatment. The 1-year and 2-year overall survival in this cohort is 69% and 60%, respectively. At the median follow-up, FFLP for this cohort was 80.4%. FFLP for patients with hepatocellular carcinomas, colorectal metastasis, and all other lesions were 100%, 75%, and 83%, respectively. CONCLUSIONS: This study describes the first clinical outcomes of MR-guided liver SBRT. Treatment was well tolerated by patients with excellent local control. This study lays the foundation for future dose escalation and adaptive treatment for liver-based primary malignancies and/or metastatic disease.

18.
Adv Radiat Oncol ; 3(2): 209-215, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29904747

RESUMO

PURPOSE: We present a rapid computational method for quantifying interfraction motion of the esophagus in patients undergoing stereotactic body radiation therapy on a magnetic resonance (MR) guided radiation therapy system. METHODS AND MATERIALS: Patients who underwent stereotactic body radiation therapy had simulation computed tomography (CT) and on-treatment MR scans performed. The esophagus was contoured on each scan. CT contours were transferred to MR volumes via rigid registration. Digital Imaging and Communications in Medicine files containing contour points were exported to MATLAB. In-plane CT and MR contour points were spline interpolated, yielding boundaries with centroid positions, CCT and CMR. MR contour points lying outside of the CT contour were extracted. For each such point, BMR(j), a segment from CCT intersecting BMR(j), was produced; its intersection with the CT contour, BCT(i), was calculated. The length of the segment Sij, between BCT(i) and BMR(j), was found. The orientation θ was calculated from Sij vector components:θ = arctan[(Sij)y / (Sij)x]A set of segments {Sij} was produced for each slice and binned by quadrant with 0° < θ ≤ 90°, 90° < θ ≤ 180°, 180° < θ ≤ 270°, and 270° < θ ≤ 360° for the left anterior, right anterior, right posterior, and left posterior quadrants, respectively. Slices were binned into upper, middle, and lower esophageal (LE) segments. RESULTS: Seven patients, each having 3 MR scans, were evaluated, yielding 1629 axial slices and 84,716 measurements. The LE segment exhibited the greatest magnitude of motion. The mean LE measurements in the left anterior, left posterior, right anterior, and right posterior were 5.2 ± 0.07 mm, 6.0 ± 0.09 mm, 4.8 ± 0.08 mm, and 5.1 ± 0.08 mm, respectively. There was considerable interpatient variability. CONCLUSIONS: The LE segment exhibited the greatest magnitude of mobility compared with the middle and upper esophageal segments. A novel computational method enables personalized, nonuniform esophageal margins to be tailored to individual patients.

19.
Z Med Phys ; 28(3): 211-223, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29550014

RESUMO

The fast evolution of technology in radiotherapy (RT) enabled the realization of adaptive radiotherapy (ART). However, the new characteristics of ART pose unique challenges for efficiencies and effectiveness of quality assurance (QA) strategies. In this paper, we discuss the necessary QAs for ART and introduce a practical implementation. A previously published work on failure modes and effects analysis (FMEA) of ART is introduced first to explain the risks associated with ART sub-processes. After a brief discussion of QA challenges, we review the existing QA strategies and tools that might be suitable for each ART step. By introducing the MR-guided online ART QA processes developed at our institute, we demonstrate a practical implementation. The limitations and future works to develop more robust and efficient QA strategies are discussed at the end.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde , Radioterapia/normas , Humanos , Fótons , Física
20.
Med Phys ; 2018 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-29807390

RESUMO

PURPOSE: We describe the acceptance testing, commissioning, periodic quality assurance, and workflow procedures developed for the first clinically implemented magnetic resonance imaging-guided radiation therapy (MR-IGRT) system for real-time tracking and beam control. METHODS: The system utilizes real-time cine imaging capabilities at 4 frames per second for real-time tracking and beam control. Testing of the system was performed using an in-house developed motion platform and a commercially available motion phantom. Anatomical tracking is performed by first identifying a target (a region of interest that is either tissue to be treated or a critical structure) and generating a contour around it. A boundary contour is also created to identify tracking margins. The tracking algorithm deforms the anatomical contour (target or a normal organ) on every subsequent cine frame and compares it to the static boundary contour. If the anatomy of interest moves outside the boundary, the radiation delivery is halted until the tracked anatomy returns to treatment portal. The following were performed to validate and clinically implement the system: (a) spatial integrity evaluation; (b) tracking accuracy; (c) latency; (d) relative point dose and spatial dosimetry; (e) development of clinical workflow for gating; and (f) independent verification by an outside credentialing service. RESULTS: The spatial integrity of the MR system was found to be within 2 mm over a 45-cm diameter field-of-view. The tracking accuracy for geometric targets was within 1.2 mm. The average system latency was measured to be within 394 ms. The dosimetric accuracy using ionization chambers was within 1.3% ± 1.7%, and the dosimetric spatial accuracy was within 2 mm. The phantom irradiation for the outside credentialing service had satisfactory results, as well. CONCLUSIONS: The first clinical MR-IGRT system was validated for real-time tracking and gating capabilities and shown to be reliable and accurate. Patient workflow methods were developed for efficient treatment. Periodic quality assurance tests can be efficiently performed with commercially available equipment to ensure accurate system performance.