J Acoust Soc Am ; 155(1): 555-567, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-38259128

RESUMO

The hearing abilities of mammals are impacted by factors such as social cues, habitat, and physical characteristics. Despite being used commonly to study social behaviors, hearing of the monogamous prairie vole (Microtus ochrogaster) has never been characterized. In this study, anatomical features are measured and auditory brainstem responses (ABRs) are used to measure auditory capabilities of prairie voles, characterizing monaural and binaural hearing and hearing range. Sexually naive male and female voles were measured to characterize differences due to sex. It was found that prairie voles show a hearing range with greatest sensitivity between 8 and 32 kHz, binaural hearing across interaural time difference ranges appropriate for their head sizes. No differences are shown between the sexes in binaural hearing or hearing range (except at 1 kHz), however, female voles have increased amplitude of peripheral ABR waves I and II and longer latency of waves III and IV compared to males. The results confirm that prairie voles have a broad hearing range, binaural hearing consistent with rodents of similar size, and differences in amplitudes and thresholds of monaural physiological measures between the sexes. These data further highlight the necessity to understand sex-specific differences in neural processing that may underly variability in responses between sexes.


Assuntos
Pradaria , Audição , Feminino , Masculino , Animais , Arvicolinae , Sinais (Psicologia)
2.
Proc Biol Sci ; 289(1980): 20220878, 2022 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-35946148

RESUMO

Life underground often leads to animals having specialized auditory systems to accommodate the constraints of acoustic transmission in tunnels. Despite living underground, naked mole-rats use a highly vocal communication system, implying that they rely on central auditory processing. However, little is known about these animals' central auditory system, and whether it follows a similar developmental time course as other rodents. Naked mole-rats show slowed development in the hippocampus suggesting they have altered brain development compared to other rodents. Here, we measured morphological characteristics and voltage-gated potassium channel Kv3.3 expression and protein levels at different key developmental time points (postnatal days 9, 14, 21 and adulthood) to determine whether the auditory brainstem (lateral superior olive and medial nucleus of the trapezoid body) develops similarly to two common auditory rodent model species: gerbils and mice. Additionally, we measured the hearing onset of naked mole-rats using auditory brainstem response recordings at the same developmental timepoints. In contrast with other work in naked mole-rats showing that they are highly divergent in many aspects of their physiology, we show that naked mole-rats have a similar hearing onset, between postnatal day (P) 9 and P14, to many other rodents. On the other hand, we show some developmental differences, such as a unique morphology and Kv3.3 protein levels in the brainstem.


Assuntos
Tronco Encefálico , Ratos-Toupeira , Animais , Percepção Auditiva/fisiologia , Tronco Encefálico/anatomia & histologia , Gerbillinae , Hipocampo , Camundongos , Ratos-Toupeira/fisiologia
3.
J Acoust Soc Am ; 152(1): 437, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35931550

RESUMO

Animals localise sound by making use of acoustical cues resulting from space and frequency dependent filtering of sound by the head and body. Sound arrives at each ear at different times, with different intensities, and with varying spectral content, all of which are affected by the animal's head and the relative sound source position. Location cues in mammals benefit from structures (pinnae) that modify these cues and provide information that helps resolve the cone of confusion and provide cues to sound source elevation. Animals without pinnae must rely on other mechanisms to solve localisation problems. Most non-mammals lack pinna-like structures, but some possess other anatomical features that could influence hearing. One such animal is the frill-necked lizard (Chlamydosaurus kingii). The species' elaborate neck frill has been speculated to act as an aid to hearing, but no acoustical measurements have been reported. In this study, we characterise the frill's influence on the acoustical information available to the animal. Results suggest that the change in binaural cues is not sufficiently large to impact localisation behavior within the species' likely audiometric range; however, the frill does increase gain for sounds directly in front of the animal similar to a directional microphone.


Assuntos
Lagartos , Localização de Som , Estimulação Acústica , Animais , Sinais (Psicologia) , Audição , Mamíferos , Som
4.
Ear Hear ; 42(3): 629-643, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33141776

RESUMO

OBJECTIVES: The binaural interaction component (BIC) of the auditory brainstem response (ABR) is obtained by subtracting the sum of the monaural right and left ear ABRs from the binaurally evoked ABR. The result is a small but prominent negative peak (herein called "DN1"), indicating a smaller binaural than summed ABR, which occurs around the latency of wave V or its roll-off slope. The BIC has been proposed to have diagnostic value as a biomarker of binaural processing abilities; however, there have been conflicting reports regarding the reliability of BIC measures in human subjects. The objectives of the current study were to: (1) examine prevalence of BIC across a large group of normal-hearing young adults; (2) determine effects of interaural time differences (ITDs) on BIC; and (3) examine any relationship between BIC and behavioral ITD discrimination acuity. DESIGN: Subjects were 40 normal-hearing adults (20 males and 20 females), aged 21 to 48 years, with no history of otologic or neurologic disorders. Midline ABRs were recorded from electrodes at high forehead (Fz) referenced to the nape of the neck (near the seventh cervical vertebra), with Fpz (low forehead) as the ground. ABRs were also recorded with a conventional earlobe reference for comparison to midline results. Stimuli were 90 dB peSPL biphasic clicks. For BIC measurements, stimuli were presented in a block as interleaved right monaural, left monaural, and binaural stimuli with 2000+ presentations per condition. Four measurements were averaged for a total of 8000+ stimuli per analyzed waveform. BIC was measured for ITD = 0 (simultaneous bilateral) and for ITDs of ±500 and ±750 µs. Subjects separately performed a lateralization task, using the same stimuli, to determine ITD discrimination thresholds. RESULTS: An identifiable BIC DN1 was obtained in 39 of 40 subjects at ITD = 0 µs in at least one of two measurement sessions, but was seen in lesser numbers of subjects in a single session or as ITD increased. BIC was most often seen when a subject was relaxed or sleeping, and less often when they fidgeted or reported neck tension, suggesting myogenic activity as a possible factor in disrupting BIC measurements. Mean BIC latencies systematically increased with increasing ITD, and mean BIC amplitudes tended to decrease. However, across subjects, there was no significant relationship between the amplitude or latency of the BIC and behavioral ITD thresholds. CONCLUSIONS: Consistent with previous studies, measurement of the BIC was time consuming and a BIC was sometimes difficult to obtain in awake normal-hearing subjects. The BIC will thus continue to be of limited clinical utility unless stimulus parameters and measurement techniques can be identified that produce a more robust response. Nonetheless, modulation of BIC characteristics by ITD supports the concept that the ABR BIC indexes aspects of binaural brainstem processing and thus may prove useful in selected research applications, e.g. in the examination of populations expected to have aberrant binaural signal processing ability.


Assuntos
Potenciais Evocados Auditivos do Tronco Encefálico , Testes Auditivos , Estimulação Acústica , Tronco Encefálico , Eletrodos , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Adulto Jovem
5.
Ear Hear ; 41(2): 312-322, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31389846

RESUMO

OBJECTIVES: To compare contralateral to ipsilateral stimulation with percutaneous and transcutaneous bone conduction implants. BACKGROUND: Bone conduction implants (BCIs) effectively treat conductive and mixed hearing losses. In some cases, such as in single-sided deafness, the BCI is implanted contralateral to the remaining healthy ear in an attempt to restore some of the benefits provided by binaural hearing. While the benefit of contralateral stimulation has been shown in at least some patients, it is not clear what cues or mechanisms contribute to this function. Previous studies have investigated the motion of the ossicular chain, skull, and round window in response to bone vibration. Here, we extend those reports by reporting simultaneous measurements of cochlear promontory velocity and intracochlear pressures during bone conduction stimulation with two common BCI attachments, and directly compare ipsilateral to contralateral stimulation. METHODS: Fresh-frozen whole human heads were prepared bilaterally with mastoidectomies. Intracochlear pressure (PIC) in the scala vestibuli (PSV) and tympani (PST) was measured with fiber optic pressure probes concurrently with cochlear promontory velocity (VProm) via laser Doppler vibrometry during stimulation provided with a closed-field loudspeaker or a BCI. Stimuli were pure tones between 120 and 10,240 Hz, and response magnitudes and phases for PIC and VProm were measured for air and bone conducted sound presentation. RESULTS: Contralateral stimulation produced lower response magnitudes and longer delays than ipsilateral in all measures, particularly for high-frequency stimulation. Contralateral response magnitudes were lower than ipsilateral response magnitudes by up to 10 to 15 dB above ~2 kHz for a skin-penetrating abutment, which increased to 25 to 30 dB and extended to lower frequencies when applied with a transcutaneous (skin drive) attachment. CONCLUSIONS: Transcranial attenuation and delay suggest that ipsilateral stimulation will be dominant for frequencies over ~1 kHz, and that complex phase interactions will occur during bilateral or bimodal stimulation. These effects indicate a mechanism by which bilateral users could gain some bilateral advantage.


Assuntos
Condução Óssea , Rampa do Vestíbulo , Estimulação Acústica , Cóclea , Audição , Humanos , Som
6.
J Acoust Soc Am ; 146(5): 3993, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31795698

RESUMO

Middle ear muscle contractions (MEMC) can be elicited in response to high-level sounds, and have been used clinically as acoustic reflexes (ARs) during evaluations of auditory system integrity. The results of clinical AR evaluations do not necessarily generalize to different signal types or durations. The purpose of this study was to evaluate the likelihood of observing MEMC in response to brief sound stimuli (tones, recorded gunshots, noise) in adult participants (N = 190) exhibiting clinical ARs and excellent hearing sensitivity. Results revealed that the presence of clinical ARs was not a sufficient indication that listeners will also exhibit MEMC for brief sounds. Detection rates varied across stimulus types between approximately 20% and 80%. Probabilities of observing MEMC also differed by clinical AR magnitude and latency, and declined over the period of minutes during the course of the MEMC measurement series. These results provide no support for the inclusion of MEMC as a protective factor in damage-risk criteria for impulsive noises, and the limited predictability of whether a given individual will exhibit MEMC in response to a brief sound indicates a need to measure and control for MEMC in studies evaluating pharmaceutical interventions for hearing loss.


Assuntos
Orelha Média/fisiologia , Testes Auditivos/métodos , Reflexo Acústico , Estimulação Acústica/métodos , Estimulação Acústica/normas , Adolescente , Adulto , Feminino , Testes Auditivos/normas , Humanos , Masculino , Pessoa de Meia-Idade , Contração Muscular , Tempo de Reação , Som
7.
Hear Res ; 428: 108669, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36565603

RESUMO

INTRODUCTION: Injuries to the peripheral auditory system are among the most common results of high intensity impulsive noise exposure. Hearing protection can mitigate this injury, but careful assessment of the insertion loss they provide is necessary. Insertion loss is typically measured using microphone-based acoustic manikins to measure the decrease in sound pressure level transmitted into the ear canal, which precisely measure the change in air conducted sound, but neglect alternate pathways to the inner ear such as bone conduction. In a previous study we reported intracochlear pressures in cadaveric human specimens to acoustic shock waves, which revealed a substantial bone conducted component (Greene, et al., 2018). Here we evaluate insertion loss to several hearing protection devices (HPDs) in those same specimens using intracochlear pressure measurements. METHODS: Human cadaver heads were exposed to impulsive acoustic pressure waves with peak overpressures of 7 and 28 kPa (171 & 183 dB SPL). Ear canal (EAC), middle ear, and intracochlear sound pressure levels were measured bilaterally with fiber-optic pressure sensors. Surface-mounted sensors measured SPL and skull strain near the opening of each EAC and at the forehead. Responses were measured with specimen ears unoccluded, as reported previously, as well as fitted with four types of HPDs. Impulse peak insertion loss (IPIL) and impulse spectrum insertion loss (ISIL) were calculated for each HPD. RESULTS: For all HPDs, IPIL generally increases with exposure level, though ISIL tended to be more consistent, and the spectral characteristics across frequency appear to be highly dependent on exposure level. ISIL measured in the ear canal tended to overestimate insertion loss measured in the cochlea, particularly at frequencies > 1 kHz; however, low signal-to-noise in intracochlear pressures limited comparisons. As a proof of concept, 36 low-level unoccluded exposures, were averaged together, and the resulting signal-to-noise ratio was improved by up to 15 dB. CONCLUSIONS: Insertion loss measured in the cochlea was lower than in the ear canal, suggesting substantial contributions from transmission pathways in parallel with air conduction (e.g., bone conduction) were present, which will require novel strategies to mitigate. However, high variance was observed, and noise reduction strategies should be utilized in future studies to facilitate more precise insertion loss estimates.


Assuntos
Cóclea , Som , Humanos , Cóclea/fisiologia , Audição/fisiologia , Ruído/efeitos adversos , Acústica
8.
Hear Res ; 437: 108839, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37429100

RESUMO

The binaural interaction component (BIC) of the auditory brainstem response (ABR) is the difference obtained after subtracting the sum of right and left ear ABRs from binaurally evoked ABRs. The BIC has attracted interest as a biomarker of binaural processing abilities. Best binaural processing is presumed to require spectrally-matched inputs at the two ears, but peripheral pathology and/or impacts of hearing devices can lead to mismatched inputs. Such mismatching can degrade behavioral sensitivity to interaural time difference (ITD) cues, but might be detected using the BIC. Here, we examine the effect of interaural frequency mismatch (IFM) on BIC and behavioral ITD sensitivity in audiometrically normal adult human subjects (both sexes). Binaural and monaural ABRs were recorded and BICs computed from subjects in response to narrowband tones. Left ear stimuli were fixed at 4000 Hz while right ear stimuli varied over a ∼2-octave range (re: 4000 Hz). Separately, subjects performed psychophysical lateralization tasks using the same stimuli to determine ITD discrimination thresholds jointly as a function of IFM and sound level. Results demonstrated significant effects of IFM on BIC amplitudes, with lower amplitudes in mismatched conditions than frequency-matched. Behavioral ITD discrimination thresholds were elevated at mismatched frequencies and lower sound levels, but also more sharply modulated by IFM at lower sound levels. Combinations of ITD, IFM and overall sound level that resulted in fused and lateralized percepts were bound by the empirically-measured BIC, and also by model predictions simulated using an established computational model of the brainstem circuit thought to generate the BIC.


Assuntos
Potenciais Evocados Auditivos do Tronco Encefálico , Localização de Som , Masculino , Adulto , Feminino , Humanos , Estimulação Acústica/métodos , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Tronco Encefálico/fisiologia , Eletroencefalografia , Localização de Som/fisiologia
9.
Otolaryngol Head Neck Surg ; 168(3): 462-468, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35671134

RESUMO

OBJECTIVE: Sensorineural hearing loss is a known complication of stapes surgery. We previously showed that laser stapedotomy can result in intracochlear pressures that are comparable to high sound pressure levels. Optimizing laser settings to those that correspond with the lowest pressure changes may mitigate risk for postoperative hearing loss. Here we quantify the effects of various laser parameters on intracochlear pressures and test the hypothesis that intracochlear pressure changes are proportional to the laser energy delivered. STUDY DESIGN: Basic and translational science. SETTING: Cadaveric dissection and basic science laboratory. METHODS: Cadaveric human heads underwent mastoidectomies. Intracochlear pressures were measured via fiber-optic pressure probes placed in scala vestibuli and tympani. Pulses of varied stimulus power and duration from a 980-nm diode laser were applied to the stapes footplate. RESULTS: Sustained high-intensity pressures were observed in the cochlea during all laser applications. Observed pressure magnitudes increased monotonically with laser energy and rose linearly for lower stimulus durations and powers, but there was increased variability for laser applications of longer duration (200-300 ms) and/or higher power (8 W). CONCLUSIONS: Results confirm that significant pressure changes occur during laser stapedotomy, which we hypothesize may cause injury. Overall energy delivered depends predictably on duration and power, but surgeons should use caution at the highest stimulus levels and longest pulse durations due to the increasing variability in intracochlear pressure under these stimulus conditions. While the risk to hearing from increased intracochlear pressures from laser stapedotomy remains unclear, these results affirm the need to optimize laser settings to avoid unintended injury.


Assuntos
Terapia a Laser , Cirurgia do Estribo , Humanos , Cóclea/cirurgia , Audição , Lasers , Cadáver , Terapia a Laser/efeitos adversos
10.
J Neurophysiol ; 108(7): 1942-53, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22745462

RESUMO

Anatomical and pharmacological studies have shown that the lateral superior olive (LSO) receives inputs from a number of sources and that LSO cells can alter the balance of their own excitatory and inhibitory drive. It is thus likely that the ongoing sound-evoked responses of LSO cells reflect a complex interplay of excitatory and inhibitory events, which may be affected by anesthesia. The goal of this study was to characterize the temporal discharge patterns of single units in the LSO of unanesthetized, decerebrate cats in response to long-duration ipsilateral best-frequency tone bursts. A decision tree is presented to partition LSO units on the basis of poststimulus time histogram shape, adaptation of instantaneous firing rate as a function of time, and sustained discharge rate. The results suggest that LSO discharge patterns form a continuum with four archetypes: sustained choppers that show two or more peaks of activity at stimulus onset and little adaptation of rate throughout the response, transient choppers that undergo a decrease in rate that eventually stabilizes with time, primary-like units that display an initial peak of activity followed by a monotonic decline in rate to a steady-state value, and onset-sustained units that exhibit an initial peak of activity at stimulus onset followed by a low sustained activity. Compared with the chopper units, the nonchopper units tend to show longer first-spike latencies, lower peak firing rates, and more irregular sustained discharge patterns. Modeling studies show that the full range of LSO response types can be obtained from an underlying sustained chopper by varying the strength and latency of a sound-driven ipsilateral inhibition relative to that of excitation. Together, these results suggest that inhibition plays a major role in shaping the temporal discharge patterns of units in unanesthetized preparations.


Assuntos
Potenciais de Ação , Vias Auditivas/fisiologia , Tronco Encefálico/fisiologia , Estado de Descerebração/fisiopatologia , Animais , Gatos , Modelos Neurológicos
11.
Otol Neurotol ; 43(2): 174-182, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34753876

RESUMO

HYPOTHESIS: High intracochlear pressure transients associated with cochlear implant placement are reduced with smaller, non-styleted arrays, and longer insertion durations. BACKGROUND: With increasing focus on hearing preservation during cochlear implant surgery, atraumatic technique is of the utmost importance. Previous studies revealed that high intensity pressure transients can be generated during the insertion of implant electrodes. Resulting acoustic trauma may be one contributing factor to postoperative loss of residual hearing. METHODS: Thirty ears in cadaveric specimens were surgically prepared with placement of intracochlear pressure sensors. Sequential implant insertions were made over 10, 30, or 60 seconds using seven randomly ordered electrode styles. Pressures were also measured during common post-insertion electrode manipulations and removal. Measurements were compared between electrode styles and characteristics using analysis of variance (ANOVA) and Pearson correlation. RESULTS: Implant insertion and post-insertion manipulations produced high-intensity pressure transients with all electrodes tested, with some measurements exceeding 170 dB peak SPL. Average peak pressures were significantly lower for straight, non-stylet electrodes (p << 0.001). The likelihood of generating transients was lowest with the slowest insertions (p << 0.001). CONCLUSIONS: Cochlear implant insertion can generate transients in intralabyrinthine pressure levels equivalent to high intensity, impulsive acoustic stimuli known to cause hearing loss. Although transients were observed in all conditions, exposure may be mitigated by using non-styleted electrodes and slow insertion speeds. Additional surgical manipulations can also produce similar high-pressure events. Results from this investigation suggest that use of non-styleted electrodes, slow but steady insertion speeds, and avoidance of post-insertional manipulations are important to reduce cochlear trauma.


Assuntos
Implante Coclear , Implantes Cocleares , Cóclea/cirurgia , Implante Coclear/métodos , Implantes Cocleares/efeitos adversos , Eletrodos Implantados , Audição , Humanos , Pressão
12.
Hear Res ; 424: 108594, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35964452

RESUMO

Middle ear muscle contractions (MEMCs) are most commonly considered a response to high-level acoustic stimuli. However, MEMCs have also been observed in the absence of sound, either as a response to somatosensory stimulation or in concert with other motor activity. The relationship between MEMCs and non-acoustic sources is unclear. This study examined associations between measures of voluntary unilateral eye closure and impedance-based measures indicative of middle ear muscle activity while controlling for demographic and clinical factors in a large group of participants (N=190) with present clinical acoustic reflexes and no evidence of auditory dysfunction. Participants were instructed to voluntarily close the eye ipsilateral to the ear canal containing a detection probe at three levels of effort. Orbicularis oculi muscle activity was measured using surface electromyography. Middle ear muscle activity was inferred from changes in total energy reflected in the ear canal using a filtered (0.2 to 8 kHz) click train. Results revealed that middle ear muscle activity was positively associated with eye muscle activity. MEMC occurrence rates for eye closure observed in this study were generally higher than previously published rates for high-level brief acoustic stimuli in the same participant pool suggesting that motor activity may be a more reliable elicitor of MEMCs than acoustic stimuli. These results suggest motor activity can serve as a confounding factor for auditory exposure studies as well as complicate the interpretation of any impulsive noise damage risk criteria that assume MEMCs serve as a consistent, uniform protective factor. The mechanism linking eye and middle ear muscle activity is not understood and is an avenue for future research.


Assuntos
Orelha Média , Testes Auditivos , Estimulação Acústica/métodos , Orelha Média/fisiologia , Testes Auditivos/métodos , Humanos , Contração Muscular , Som
13.
eNeuro ; 8(6)2021.
Artigo em Inglês | MEDLINE | ID: mdl-34872939

RESUMO

The binaural interaction component (BIC) is a sound-evoked electrophysiological signature of binaural processing in the auditory brainstem that has received attention as a potential biomarker for spatial hearing deficits. Yet the number of trials necessary to evoke the BIC, or its measurability, seems to vary across species: while it is easily measured in small rodents, it has proven to be highly variable and less reliably measured in humans. This has hindered its potential use as a diagnostic tool. Further measurements of the BIC across a wide range of species could help us better understand its origin and the possible reasons for the variation in its measurability. Statistical analysis on the function relating BIC DN1 amplitude and the interaural time difference has been performed in only a few small rodent species, thus it remains to be shown how the results apply to more taxonomically diverse mammals, and those with larger heads. To fill this gap, we measured BICs in rhesus macaque. We show the overall behavior of the BIC is the same as in smaller rodents, suggesting that the brainstem circuit responsible for the BIC is conserved across a wider range of mammals. We suggest that differences in measurability are likely because of differences in head size.


Assuntos
Tronco Encefálico , Potenciais Evocados Auditivos do Tronco Encefálico , Estimulação Acústica , Animais , Macaca mulatta , Som
14.
Hear Res ; 395: 108017, 2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32709398

RESUMO

This article presents a comparative study of morphology of the avian middle ear. The general morphology of the columella shows considerable variation across species, yet few studies have attempted to provide quantitative comparisons, and basic anatomical data has not been thoroughly reported. In this study, we examined the middle ear in 49 taxonomically diverse species of bird. We found significant correlations between measurements of several features (columellar length, mass, tympanic membrane area, footplate area) and interaural diameter. While scaling of columellar length with interaural diameter is consistent with isometry, masses and areas showed negative allometry, or a non-proportional scaling with interaural diameter. These observations remained true even for species with unusual middle ear morphology, such as Alcedinidae (Kingfishers) in which the basal struts of the columella form a structure almost resembling a mammalian stapes, or Tytonidae (Barn Owls) which have a highly bulbous footplate. It therefore appears that allometry cannot help explain the morphological variation in the columella.


Assuntos
Orelha Média , Animais , Aves , Mamíferos , Estribo , Membrana Timpânica
15.
Hear Res ; 395: 108043, 2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32828615

RESUMO

Sound and hearing play an important role in the lives of many birds, and studies have been published on the acoustic habitat of various species, as well as on various aspects of their hearing system. However the function of the middle ear remains largely unexplored, with existing studies focusing on either single species, or a very narrow range of species. In this article we report measurements of the middle ear transfer function in 39 taxonomically diverse avian species. We used laser vibrometry to measure the vibrations of the columellar footplate in response to tones played in each animal's ear canal, and calculated the middle ear transfer functions. Transfer functions varied substantially across species, but appeared to follow common trends. Comparisons between the peak frequency in the transfer function and length/mass of the columella reveal a correlation between the three, however statistical analysis suggests that columellar length is a primary indicator of the peak frequency. These results provide a broad survey of avian middle ear function, and the observed trends provide a method with which to begin to predict the response of single ossicle middle ear systems.


Assuntos
Orelha Média , Animais , Aves , Audição , Som
16.
Otol Neurotol ; 41(3): 308-317, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31746814

RESUMO

HYPOTHESIS: Surgical manipulations during laser stapedotomy can produce intracochlear pressure changes comparable to pressures created by high-intensity acoustic stimuli. BACKGROUND: New-onset sensorineural hearing loss is a known risk of stapes surgery and may result from pressure changes from laser use or other surgical manipulations. Here, we test the hypothesis that high sound pressure levels are generated in the cochlea during laser stapedotomy. METHODS: Human cadaveric heads underwent mastoidectomy. Fiber-optic sensors were placed in scala tympani and vestibuli to measure intracochlear pressures during key steps in stapedotomy surgery, including cutting stapedius tendon, lasering of stapedial crurae, crural downfracture, and lasering of the footplate. RESULTS: Key steps in laser stapedotomy produced high-intensity pressures in the cochlea. Pressure transients were comparable to intracochlear pressures measured in response to high intensity impulsive acoustic stimuli. CONCLUSION: Our results demonstrate that surgical manipulations during laser stapedotomy can create significant pressure changes within the cochlea, suggesting laser application should be minimized and alternatives to mechanical downfracture should be investigated. Results from this investigation suggest that intracochlear pressure transients from stapedotomy may be of sufficient magnitude to cause damage to the sensory epithelium and affirm the importance of limiting surgical traumatic exposures.


Assuntos
Terapia a Laser , Cirurgia do Estribo , Cóclea/cirurgia , Orelha Média , Humanos , Terapia a Laser/efeitos adversos , Lasers , Rampa do Tímpano , Cirurgia do Estribo/efeitos adversos
17.
eNeuro ; 7(1)2020.
Artigo em Inglês | MEDLINE | ID: mdl-31953317

RESUMO

The auditory brainstem compares sound-evoked excitation and inhibition from both ears to compute sound source location and determine spatial acuity. Although alterations to the anatomy and physiology of the auditory brainstem have been demonstrated in fragile X syndrome (FXS), it is not known whether these changes cause spatial acuity deficits in FXS. To test the hypothesis that FXS-related alterations to brainstem circuits impair spatial hearing abilities, a reflexive prepulse inhibition (PPI) task, with variations in sound (gap, location, masking) as the prepulse stimulus, was used on Fmr1 knock-out mice and B6 controls. Specifically, Fmr1 mice show decreased PPI compared with wild-type mice during gap detection, changes in sound source location, and spatial release from masking with no alteration to their overall startle thresholds compared with wild-type mice. Last, Fmr1 mice have increased latency to respond in these tasks, suggesting additional impairments in the pathway responsible for reacting to a startling sound. This study further supports data in humans with FXS that show similar deficits in PPI.


Assuntos
Síndrome do Cromossomo X Frágil , Audição , Estimulação Acústica , Animais , Proteína do X Frágil da Deficiência Intelectual/genética , Síndrome do Cromossomo X Frágil/genética , Camundongos , Camundongos Knockout
18.
Otol Neurotol ; 41(1): e46-e54, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31613835

RESUMO

BACKGROUND: Combined electrical-acoustical stimulation (EAS) has gained popularity as patients with residual hearing are increasingly undergoing cochlear implantation. Preservation of residual hearing correlates with hearing outcomes, but loss of hearing occurs in a subset of these patients. Several mechanisms have been proposed as causing this hearing loss; we have previously described high amplitude pressure transients, equivalent to high-level noise exposures, in the inner ear during electrode insertion. The source of these transients has not been identified. METHODS: Cadaveric human heads were prepared with an extended facial recess. Fiber-optic pressure sensors were inserted into the scala vestibuli and scala tympani to measure intracochlear pressures. Two cochlear implant (CI) electrode styles (straight and perimodiolar) were inserted during time-synced intracochlear pressures and video fluoroscopy measurements. RESULTS: CI electrode insertions produced pressure transients in the cochlea up to 160 to 170 dB pSPL equivalent for both styles, consistent with previous results. However, the position of the electrode within the cochlea when transients were generated differed (particularly contact with the medial or lateral walls). CONCLUSIONS: These results begin to elucidate the insertion pressure profiles of CI electrodes, which can be used to improve CI electrode designs and facilitate "silent-insertions" to improve chances of hearing preservation.


Assuntos
Cóclea , Implante Coclear/efeitos adversos , Implantes Cocleares , Cadáver , Cóclea/fisiologia , Cóclea/cirurgia , Implante Coclear/métodos , Feminino , Fluoroscopia , Humanos
19.
Hear Res ; 378: 53-62, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30538053

RESUMO

The current study addressed the existence of an anticipatory middle-ear muscle contraction (MEMC) as a protective mechanism found in recent damage-risk criteria for impulse noise exposure. Specifically, the experiments reported here tested instances when an exposed individual was aware of and could anticipate the arrival of an acoustic impulse. In order to detect MEMCs in human subjects, a laser-Doppler vibrometer (LDV) was used to measure tympanic membrane (TM) motion in response to a probe tone. Here we directly measured the time course and relative magnitude changes of TM velocity in response to an acoustic reflex-eliciting (i.e. MEMC eliciting) impulse in 59 subjects with clinically assessable MEMCs. After verifying the presence of the MEMC, we used a classical conditioning paradigm pairing reflex-eliciting acoustic impulses (unconditioned stimulus, UCS) with various preceding stimuli (conditioned stimulus, CS). Changes in the time-course of the MEMC following conditioning were considered evidence of MEMC conditioning, and any indication of an MEMC prior to the onset of the acoustic elicitor was considered an anticipatory response. Nine subjects did not produce a MEMC measurable via LDV. For those subjects with an observable MEMC (n = 50), 48 subjects (96%) did not show evidence of an anticipatory response after conditioning, whereas only 2 subjects (4%) did. These findings reveal that MEMCs are not readily conditioned in most individuals, suggesting that anticipatory MEMCs are not prevalent within the general population. The prevalence of anticipatory MEMCs does not appear to be sufficient to justify inclusion as a protective mechanism in auditory injury risk assessments.


Assuntos
Estimulação Acústica , Antecipação Psicológica , Testes Auditivos , Audição , Contração Muscular , Reflexo Acústico , Estapédio/inervação , Tensor de Tímpano/inervação , Membrana Timpânica/fisiologia , Adulto , Condicionamento Psicológico , Feminino , Humanos , Fluxometria por Laser-Doppler , Masculino , Pessoa de Meia-Idade , Movimento , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Adulto Jovem
20.
Otolaryngol Head Neck Surg ; 161(6): 1004-1011, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31570054

RESUMO

OBJECTIVES: (1) To characterize changes in brainstem neural activity following unilateral deafening in an animal model. (2) To compare brainstem neural activity from unilaterally deafened animals with that of normal-hearing controls. STUDY DESIGN: Prospective controlled animal study. SETTING: Vivarium and animal research facilities. SUBJECTS AND METHODS: The effect of single-sided deafness on brainstem activity was studied in Chinchilla lanigera. Animals were unilaterally deafened via gentamycin injection into the middle ear, which was verified by loss of auditory brainstem responses (ABRs). Animals underwent measurement of ABR and local field potential in the inferior colliculus. RESULTS: Four animals underwent chemical deafening, with 2 normal-hearing animals as controls. ABRs confirmed unilateral loss of auditory function. Deafened animals demonstrated symmetric local field potential responses that were distinctly different than the contralaterally dominated responses of the inferior colliculus seen in normal-hearing animals. CONCLUSION: We successfully developed a model for unilateral deafness to investigate effects of single-sided deafness on brainstem plasticity. This preliminary investigation serves as a foundation for more comprehensive studies that will include cochlear implantation and manipulation of binaural cues, as well as functional behavioral tests.


Assuntos
Tronco Encefálico/fisiopatologia , Chinchila , Modelos Animais de Doenças , Perda Auditiva Unilateral/etiologia , Animais , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA