Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Ir J Med Sci ; 192(2): 605-611, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35503161

RESUMO

BACKGROUND: Transcatheter aortic valve implantation-related infective endocarditis (TAVI-IE) is a well-recognised and serious complication following TAVI. The purpose of this study was to describe the clinical characteristics, microorganism spectrum, and outcomes of TAVI-IE in an Irish context. METHODS: A prospective registry was used to assess the baseline demographics, procedural variables, and clinical outcomes of patients undergoing TAVI between 2009 and 2020 at two tertiary referral Irish Hospitals. RESULTS: A total of 733 patients underwent TAVI during the study period. During a follow-up duration of 1,949 person-years (median 28 months), TAVI-IE occurred in 17 (2.3%) patients. The overall incidence was 0.87 per 100 person-years and the median time from TAVI to presentation with IE was 7 months [IQR: 5-13 months]. In those who developed TAVI-IE, the mean age was 78.7 years, 70.5% were male, and there was a trend towards more permanent pacemaker implantations post-TAVI (17.6% vs. 5.86%; p = 0.08). The dominant culprit microorganisms were streptococci (41.1%) and four (23.5%) cases were attributed to dental seeding. Major complications of TAVI-IE included one (5.8%) stroke, one (5.8%) in-hospital death, and two (11.7%) urgent surgical aortic valve replacements. The Kaplan-Meier estimate of survival at 1-year was 82% (95% CI = 55-95). CONCLUSIONS: This Irish cohort of TAVI-IE exhibited a similar incidence and time to presentation compared to prior international registries; however, the 1-year mortality rate was comparatively lower. The need for rigorous dental clearance pre-TAVI and maintenance of dental health post-TAVI is underscored by the high prevalence of oral streptococcus species in this cohort.


Assuntos
Estenose da Valva Aórtica , Endocardite Bacteriana , Endocardite , Infecções Relacionadas à Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Centros de Atenção Terciária , Mortalidade Hospitalar , Estenose da Valva Aórtica/cirurgia , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Fatores de Risco , Resultado do Tratamento
2.
Ir J Med Sci ; 189(1): 139-148, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31197575

RESUMO

INTRODUCTION: There is a paucity of published data on the clinical experience with trans-catheter aortic valve implantation (TAVI) in the Republic of Ireland. We sought to examine the clinical outcomes of patients with medium-term follow-up treated with TAVI at our institution. METHODS: A prospective TAVI registry was used to assess the baseline demographics, procedural variables and clinical outcomes of patients treated with TAVI between the inception of the programme in 2008 and November 2017. RESULTS: A total of 354 patients (mean age 80.9 ± 8.1 years, 58% male, mean STS score 6.1 ± 4.3%) were treated during the study period. Major in-hospital outcomes included in-lab death (n = 2, 0.6%), stroke (n = 8, 2.2%), device embolisation (n = 4, 1.2%), permanent pacemaker implantation (n = 22, 6.2%) and major vascular complication (n = 2, 0.6%). The median length of hospital stay was 4 days (IQR 2-8 days). The Kaplan-Meier estimate of freedom from death at 30 days and 1 year for the entire cohort was 97 ± 1% and 85.4 ± 2.3%, respectively. Trans-femoral access was associated with a significantly lower rate of death and/or stroke at 1 year compared to trans-apical access (84.9 ± 2.4% versus 60 ± 8.9%, p = 0.0005). There was no significant difference in freedom from death and/or stroke at 1 year between balloon-expandable and self-expanding valves (81.6 ± 2.6% versus 84.4 ± 7.4%, p = 0.63). CONCLUSION: This study documents low complication rates and favourable rates of survival following TAVI in a consecutive series of patients undergoing TAVI at a tertiary referral centre in the Republic of Ireland. These data support the application of this therapy in the Irish context.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Irlanda , Estimativa de Kaplan-Meier , Masculino , Estudos Prospectivos , Sistema de Registros , Acidente Vascular Cerebral/mortalidade , Centros de Atenção Terciária , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA