Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 146
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Card Surg ; 33(2): 64-68, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29460374

RESUMO

BACKGROUND: We analyzed the impact and safety of del Nido Cardioplegia (DNC) in patients undergoing minimally invasive aortic valve replacement (MIAVR). METHODS: We analyzed all isolated MIAVR replacements from 5/2013-6/2015 excluding re-operative patients. The approach was a hemi-median sternotomy in all patients. Patients were divided into two cohorts, those who received 4:1 crystalloid:blood DNC solution and those in whom standard 1:4 Buckberg-based cardioplegia (WBC) was used. One-to-one propensity case matching of DNC to WBC was performed based on standard risk factors and differences between groups were analyzed using chi-square and non-parametric methods. RESULTS: MIAVR was performed in 181 patients; DNC was used in 59 and WBC in 122. Case matching resulted in 59 patients per cohort. DNC was associated with reduced re-dosing (5/59 (8.5%) versus 39/59 (61.0%), P < 0.001) and less total cardioplegia volume (1290 ± 347 mL vs 2284 ± 828 mL, P < 0.001). Antegrade cardioplegia alone was used in 89.8% (53/59) of DNC patients versus 33.9% (20/59) of WBC patients (P < 0.001). Median bypass and aortic cross-clamp times were similar. Clinical outcomes were similar with respect to post-operative hematocrit, transfusion requirements, need for inotropic/pressor support, duration of intensive care unit stay, re-intubation, length of stay, new onset atrial fibrillation, and mortality. CONCLUSIONS: Del Nido cardioplegia usage during MIAVR minimized re-dosing and the need for retrograde delivery. Patient safety was not compromised with this technique in this group of low-risk patients undergoing MIAVR.


Assuntos
Valva Aórtica/cirurgia , Parada Cardíaca Induzida/métodos , Implante de Prótese de Valva Cardíaca/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Estudos de Coortes , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Fatores de Risco , Segurança , Esternotomia/métodos , Resultado do Tratamento
2.
J Card Surg ; 37(7): 1989, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35398925
3.
J Surg Res ; 206(1): 98-105, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27916382

RESUMO

BACKGROUND: Recurrent mitral regurgitation after mitral valve repair is common, occurring in nearly 50% of patients within 10 years of surgery. Durability of repair is partly related to stress distribution over the mitral leaflets. We hypothesized that repair with neochords (NCs) results in lower stress than leaflet resection (LR). MATERIALS AND METHODS: Magnetic resonance imaging and 3D echocardiography were performed before surgical repair of P2 prolapse in a single patient. A finite element model of the left ventricle and mitral valve was created previously, and the modeling program LS-DYNA was used to calculate leaflet stress for the following repairs: Triangular LR; LR with ring annuloplasty (LR + RA); One NC; Two NCs; and 2NC + RA. RESULTS: (1) NC placement resulted in stable posterior leaflet stress: Baseline versus 2 NC at end diastole (ED), 12.1 versus 12.0 kPa, at end systole (ES) 20.3 versus 21.7 kPa. (2) In contrast, LR increased posterior leaflet stress: Baseline versus LR at ED 12.1 versus 40.8 kPa, at ES 20.3 versus 46.1 kPa. (3) All repair types reduced anterior leaflet stress: Baseline versus 2 NC versus LR 34.2 versus 25.8 versus 20.6 kPa at ED and 80.8 versus 76.8 versus 67.8 kPa at ES. (4) The addition of RA reduced leaflet stress relative to repair without RA. CONCLUSIONS: Neochord repair restored normal leaflet coaptation without creating excessive leaflet stress, whereas leaflet resection more than doubled stress across the posterior leaflet. The excess stress created by leaflet resection was partially, but not completely, mitigated by ring annuloplasty.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Fenômenos Biomecânicos , Análise de Elementos Finitos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Anuloplastia da Valva Mitral/instrumentação , Modelos Anatômicos , Desenho de Prótese , Estresse Mecânico , Estresse Fisiológico
4.
J Card Surg ; 31(5): 303-5, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27059174

RESUMO

We describe the use of the Sapien XT, placed in the mitral position using a totally endoscopic robotic approach in a 76-year-old man with extensive circumferential mitral calcifications and severe stenosis. The patient was at high risk for traditional open surgery and a large mitral valve annulus prevented safe transcatheter deployment due to size mismatch. Our novel approach offered a minimally invasive technique for native mitral valve replacement in a high-risk patient with anatomical constraints prohibitive to conventional approaches. doi: 10.1111/jocs.12737 (J Card Surg 2016;31:303-305).


Assuntos
Calcinose/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Robótica/métodos , Idoso , Calcinose/diagnóstico , Ecocardiografia Transesofagiana , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Desenho de Prótese , Índice de Gravidade de Doença
5.
J Cardiothorac Vasc Anesth ; 29(4): 930-6, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25620765

RESUMO

OBJECTIVE: The aim of this study was to evaluate the addition of paravertebral blockade to general anesthesia in patients undergoing robotic mitral valve repair. DESIGN: A randomized, prospective trial. SETTING: A single tertiary referral academic medical center. PARTICIPANTS: 60 patients undergoing robotic mitral valve surgery. INTERVENTIONS: Patients were randomized to receive 4-level paravertebral blockade with 0.5% bupivicaine before induction of general anesthesia. All patients were given a fentanyl patient-controlled analgesia upon arrival to the intensive care unit, and visual analog scale pain scores were queried for 24 hours. On postoperative day 2, patients were given an anesthesia satisfaction survey. MEASUREMENTS AND MAIN RESULTS: After obtaining institutional review board approval, surgical and anesthetic data were recorded perioperatively and compared between groups. Compared to general anesthesia alone, patients receiving paravertebral blockade and general anesthesia reported significantly less postoperative pain and required fewer narcotics intraoperatively and postoperatively. Patients receiving paravertebral blockade also reported significantly higher satisfaction with anesthesia. Successful extubation in the operating room at the conclusion of surgery was 90% and similar in both groups. Hospital length of stay also was similar. No adverse reactions were reported. CONCLUSIONS: The addition of paravertebral blockade to general anesthesia appears safe and can reduce postoperative pain and narcotic usage in patients undergoing minimally invasive cardiac surgery. These findings were similar to previous studies of patients undergoing thoracic procedures. Paravertebral blockade alone likely does not reduce hospital length of stay. This may be more closely related to early extubation, which is possible with or without paravertebral blockade.


Assuntos
Implante de Prótese de Valva Cardíaca/efeitos adversos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Bloqueio Nervoso/métodos , Dor Pós-Operatória/prevenção & controle , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória/etiologia , Estudos Prospectivos , Ultrassonografia
6.
J Cardiothorac Vasc Anesth ; 29(3): 703-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25847415

RESUMO

OBJECTIVE: The present study aimed to evaluate the effect of blood conservation strategies on patient outcomes after aortic surgery. DESIGN: Retrospective cohort analysis of prospective data. SETTING: University hospital. PARTICIPANTS: Patients undergoing thoracic aortic surgery. INTERVENTIONS: One hundred thirty-two consecutive high-risk patients (mean EuroSCORE 10.4%) underwent thoracic aortic aneurysm or dissection repair from January 2010 to September 2011. A blood conservation strategy (BCS) focused on limitation of hemodilution and tolerance of perioperative anemia was used in 57 patients (43.2%); the remaining 75 (56.8%) patients were managed by traditional methods. Mortality, major complications, and red blood cell transfusion requirements were assessed. Independent risk factors for clinical outcomes were determined by multivariate analyses. MEASUREMENTS AND MAIN RESULTS: Hospital mortality was 9.8% (13 of 132). Lower preoperative hemoglobin was an independent predictor of mortality (p<0.01, odds ratio [OR] 1.7). Major complications were associated with perioperative transfusion: 0% complication rate in patients receiving<2 units of packed red blood cells versus 32.3% (20 of 62) in patients receiving ≥2 units. The blood conservation strategy had no significant impact on mortality (p = 0.4) or major complications (p = 0.9) despite the blood conservation patients having a higher incidence of aortic dissection and urgent/emergent procedures and lower preoperative and discharge hemoglobin. In patients with aortic aneurysms, BCS patients received 1.5 fewer units of red blood cells (58% reduction) than non-BCS patients (p = 0.01). Independent risk factors for transfusion were lower preoperative hemoglobin (p<0.01, OR 1.5) and lack of BCS (p = 0.02, OR 3.6). CONCLUSIONS: Clinical practice guidelines for blood conservation should be considered for high-risk complex aortic surgery patients.


Assuntos
Aorta Torácica/cirurgia , Procedimentos Médicos e Cirúrgicos sem Sangue/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Complicações Pós-Operatórias/prevenção & controle , Idoso , Procedimentos Cirúrgicos Cardíacos/mortalidade , Estudos de Coortes , Feminino , Mortalidade Hospitalar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco
7.
J Heart Valve Dis ; 23(6): 727-34, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25790620

RESUMO

BACKGROUND AND AIM OF THE STUDY: Mitral annuloplasty (MA) devices are available in different shapes and sizes, but the preferred shape and size are unclear. METHODS: A previously described and validated finite element (FE) model of the left ventricle (LV) with mitral valve (MV) based on magnetic resonance imaging and three-dimensional echocardiography images from a patient with posterior leaflet (PL; P2) prolapse was used in this study. FE models of MA devices with different shapes (flat partial, shallow saddle, pronounced saddle) and sizes (36-30) were created. Virtual leaflet resection + MA with each shape and size were simulated. Leaflet geometry, stresses in the leaflets and base of the LV, and forces in the chordae and MA sutures were calculated. RESULTS: All MA shapes increased the mitral coaptation length, reduced the elevated PL stress at end-diastole (ED) and end-systole (ES) that occurred after leaflet resection, and reduced anterior leaflet (AL) stress at ES. MA devices of all shapes and sizes modestly reduced myofiber stress at the LV base in ED and ES. In general, saddle-shaped devices had the greatest effect. CONCLUSION: All MA shapes increased coaptation length and reduced mitral leaflet stress and myofiber stress in the base of the LV. an additional reduction in MA size further increased coaptation length and reduced leaflet and myofiber stress. In general, saddle-shaped devices had the greatest effect.


Assuntos
Anuloplastia da Valva Mitral/instrumentação , Prolapso da Valva Mitral , Complicações Pós-Operatórias/prevenção & controle , Desenho de Prótese/efeitos adversos , Falha de Prótese/etiologia , Fenômenos Biomecânicos , Análise de Elementos Finitos , Ventrículos do Coração/fisiopatologia , Humanos , Imageamento Tridimensional , Valva Mitral/fisiopatologia , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/métodos , Prolapso da Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/cirurgia , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Estresse Mecânico
8.
J Heart Valve Dis ; 23(1): 66-71, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24779330

RESUMO

BACKGROUND AND AIM OF THE STUDY: Optimal repair of the mitral valve involves the implantation of an annuloplasty device to geometrically reshape and/or stabilize the annulus and improve long-term durability. It has been reported previously that trigone-to-trigone semi-rigid posterior band (PB) annuloplasty is associated with excellent short-term outcomes, physiologic motion of the anterior mitral annulus and leaflet, and lower postoperative transvalvular gradients compared to complete ring (CR) annuloplasty. The aim of this retrospective study was to compare the long-term effectiveness of PB and CR annuloplasty in patients with degenerative mitral valve regurgitation (MR). METHODS: Between 1993 and 2010, a total of 1,612 patients with degenerative MR underwent mitral valve repair (MVr) with either PB (n = 1,101) or CR (n = 511). Initially, CR was the annuloplasty device of choice, but after 2001 PB was preferred. A retrospective review of clinical and echocardiographic follow up was performed on these patients. The eight-year cumulative freedom from adverse events were determined by life-table analysis. RESULTS: Hospital mortality was 1.9% overall (n = 30/1612), but 1.3% (12/939) for isolated MVr, and 2.7% (18/673) for MVr with concomitant procedures (p = 0.04). Hospital mortality was similar for both PB (1.9%; 21/1101) and CR (1.8%; 9/511) (p = 0.8). The mean MR grade was reduced from 3.9 +/- 0.3 preoperatively to 0.6 +/- 0.9 at follow up using PB (p < 0.01), and from 3.9 +/- 0.4 to 0.9 +/- 0.9 using CR (p < 0.01). PB was associated with a similar long-term freedom from death (77 +/- 0.03% versus 83 +/- 0.02%; p = 0.4), reoperation (95 +/- 0.01% versus 92 +/- 0.01%; p = 0.06), and reoperation or recurrent severe MR (91 +/- 0.02% versus 92 +/- 0.01%; p = 0.7), and slightly greater freedom from valve-related complications compared to CR (91 +/- 0.02% versus 87 +/- 0.02%; p = 0.02). CONCLUSION: The long-term outcome of mitral valve annuloplasty with PB was comparable to that with CR for degenerative disease. Anterior annuloplasty was found to be unnecessary in this patient population.


Assuntos
Implante de Prótese de Valva Cardíaca , Anuloplastia da Valva Mitral/instrumentação , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/mortalidade , Complicações Pós-Operatórias , Reoperação , Estudos Retrospectivos , Índice de Gravidade de Doença , Adulto Jovem
9.
Semin Thorac Cardiovasc Surg ; 36(1): 27-36, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-36921680

RESUMO

We compare outcomes of endo-aortic balloon occlusion (EABO) vs external aortic clamping (EAC) in patients undergoing minimally invasive mitral valve surgery (MIMVS) in the Society of Thoracic Surgeons (STS) Adult Cardiac Surgery Database. Adults undergoing mitral valve surgery (July 2017-December 2018) were identified within the STS database (N = 60,607). Total 7,978 patients underwent a minimally invasive approach (including robotically assisted). About 1,163 EABO patients were 1:1 propensity-matched to EAC patients using exact matching on age, sex, and type of mitral procedure, and propensity score average matching for 16 other risk indicators. Early outcomes were compared. Categorical variables were compared using logistic regression; hospital and intensive care unit length of stay were compared using negative binomial regression. In the matched cohort, mean age was 62 years; 35.9% were female, and 86% underwent mitral valve repair. Cardiopulmonary bypass time was shorter for EABO vs EAC group (125.0 ± 53.0 vs 134.0 ± 67.0 minutes, P = 0.0009). There was one aortic dissection in the EAC group and none in the EABO group (P value > 0.31), and no statistically significant differences in cross-clamp time, major intraoperative bleeding, perioperative mortality, stroke, new onset of atrial fibrillation, postoperative acute kidney injury, success of repair. Median hospital LOS was shorter for EABO vs EAC procedures (4 vs 5 days, P < 0.0001). In this large, retrospective, STS database propensity-matched analysis ofpatients undergoing MIMVS, we observed similar safety outcomes for EABO and EAC, including no aortic dissections in the EABO group. The EABO group showed slightly shorter CPB times and hospital LOS.


Assuntos
Oclusão com Balão , Procedimentos Cirúrgicos Cardíacos , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos Retrospectivos , Constrição , Resultado do Tratamento , Procedimentos Cirúrgicos Minimamente Invasivos/métodos
10.
J Heart Lung Transplant ; 43(3): 471-484, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37890684

RESUMO

BACKGROUND: Drug overdose (DO) deaths rose to unprecedented levels during the coronavirus disease 2019 (COVID-19) pandemic. This study examines the impact of COVID-19 on the availability of cardiac allografts from DO donors and the implications of DO donor use on recipient survival. METHODS: Heart transplants reported to the United Network for Organ Sharing from January 2017 to November 2019 ("pre-COVID") and from March 2020 to June 2021 ("COVID pandemic") were analyzed with respect to DO donor status. Outcomes were analyzed using Kaplan-Meier survival and Cox regression to identify predictors of survival. Characteristics of discarded cardiac allografts were also compared by DO donor status. RESULTS: During the COVID-19 pandemic, 27.2% of cardiac allografts were from DO donors vs 20.5% pre-COVID, a 32.7% increase (p < 0.001). During the pandemic, DO donors were younger (84.7% vs 76.3% <40 years, p < 0.001), had higher cigarette use (16.1% vs 10.8%, p < 0.001), higher cocaine use (47.4% vs 19.7%, p < 0.001), and higher incidence of hepatitis C antibodies (26.8% vs 6.1%, p < 0.001) and RNA positivity (16.2% vs 4.2%, p < 0.001). While DO donors were less likely to require inotropic support (30.8% vs 35.4%, p = 0.008), they were more likely to have received cardiopulmonary resuscitation (95.3% vs 43.2%, p < 0.001). Recipient survival was equivalent using Kaplan-Meier analysis (log-rank, p = 0.33) and survival probability at 36 months was 85.6% (n at risk = 398) for DO donors vs 83.5% (n at risk = 1,633) for all other donors. Cox regression demonstrated that DO donor status did not predict mortality (hazard ratio 1.05; 95% confidence interval 0.90-1.23, p = 0.53). CONCLUSIONS: During the COVID-19 pandemic, there was a 32.7% increase in heart transplants utilizing DO donor hearts, and DO became the most common mechanism of death for donors. The use of DO donor hearts did not have an impact on short-term recipient survival.


Assuntos
COVID-19 , Overdose de Drogas , Transplante de Coração , Obtenção de Tecidos e Órgãos , Humanos , Estados Unidos/epidemiologia , Doadores de Tecidos , Pandemias , COVID-19/epidemiologia , Overdose de Drogas/epidemiologia , Sobrevivência de Enxerto , Estudos Retrospectivos
11.
Ann Thorac Surg ; 117(1): 96-104, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37595861

RESUMO

BACKGROUND: Contemporary national utilization and comparative safety data of robotic mitral valve repair for degenerative mitral regurgitation compared with nonrobotic approaches are lacking. The study aimed to characterize national trends of utilization and outcomes of robotic mitral repair of degenerative mitral regurgitation compared with sternotomy and thoracotomy approaches. METHODS: Patients undergoing intended mitral repair of degenerative mitral regurgitation in The Society of Thoracic Surgeons Adult Cardiac Surgery Database between 2015 and 2021 were examined. Mitral repair was performed in 61,322 patients. Descriptive analyses characterized center-level volumes and outcomes. Propensity score matching separately identified 5540 pairs of robotic vs thoracotomy approaches and 6962 pairs of robotic vs sternotomy approaches. Outcomes were operative mortality, composite mortality and major morbidity, postoperative length of stay, and conversion to mitral replacement. RESULTS: Through the 7-year study period, 116 surgeons across 103 hospitals performed mitral repair robotically. The proportion of robotic cases increased from 10.9% (949 of 8712) in 2015 to 14.6% (1274 of 8730) in 2021. In both robotic-thoracotomy and robotic-sternotomy matched pairs, mortality and morbidity were not significantly different, whereas the robotic approach had lower conversion (1.2% vs 3.1% for robotic-thoracotomy and 1.0% vs 3.7% for robotic-sternotomy), shorter length of stay, and fewer 30-day readmissions. Mortality and morbidity were lower at higher-volume centers, crossing the national mean mortality and morbidity at a cumulative robotic mitral repair case of 40. CONCLUSIONS: Robotic mitral repair is a safe and effective approach and is associated with comparable mortality and morbidity, a lower conversion rate, a shorter length of stay, and fewer 30-day readmissions than thoracotomy or sternotomy approaches.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Mitral , Procedimentos Cirúrgicos Robóticos , Adulto , Humanos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Resultado do Tratamento , Esternotomia , Procedimentos Cirúrgicos Minimamente Invasivos , Estudos Retrospectivos
12.
Ann Thorac Surg ; 117(1): 87-94, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37806334

RESUMO

BACKGROUND: The benefits of fast-track extubation in the intensive care unit (ICU) after cardiac surgery are well established. Although extubation in the operating room (OR) is safe in carefully selected patients, widespread use of this strategy in cardiac surgery remains unproven. This study was designed to evaluate perioperative outcomes with OR vs ICU extubation in patients undergoing nonemergency, isolated coronary artery bypass grafting (CABG). METHODS: The Society of Thoracic Surgeons (STS) data for all single-center patients who underwent nonemergency isolated CABG over a 6-year interval were analyzed. Perioperative morbidity and mortality with ICU vs OR extubation were compared. RESULTS: Between January 1, 2017 and December 31, 2022, 1397 patients underwent nonemergency, isolated CABG; 891 (63.8%) of these patients were extubated in the ICU, and 506 (36.2%) were extubated in the OR. Propensity matching resulted in 414 pairs. In the propensity-matched cohort, there were no differences between the 2 groups in incidence of reintubation, reoperation for bleeding, total operative time, stroke or transient ischemic attack, renal failure, or 30-day mortality. OR-extubated patients had shorter ICU hours (14 hours vs 20 hours; P < .0001), shorter postoperative hospital length of stay (3 days vs 5 days; P < .0001), a greater likelihood of being discharged directly to home (97.3% vs 89.9%; P < .0001), and a lower 30-day readmission rate (1.7% vs 4.1%; P = .04). CONCLUSIONS: Routine extubation in the OR is a feasible and safe strategy for a broad spectrum of patients after nonemergency CABG, with no increase in perioperative morbidity or mortality. Wider adoption of routine OR extubation for nonemergency CABG is indicated.


Assuntos
Extubação , Salas Cirúrgicas , Humanos , Extubação/métodos , Tempo de Internação , Estudos Retrospectivos , Ponte de Artéria Coronária
13.
ASAIO J ; 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38531093

RESUMO

The physiologic impact of pulsatile flow (PF) on end-organ perfusion during cardiopulmonary bypass (CPB) is controversial. Using an intra-aortic balloon pump (IABP) to maintain PF during CPB for patients undergoing heart transplantation (HT) may impact end-organ perfusion, with implications for postoperative outcomes. A single-center retrospective study of 76 patients bridged to HT with IABP was conducted between January 2018 and December 2022. Beginning in May 2022, patients received IABP-generated PF during CPB at an internal rate of 80 beats/minute. Fifty-eight patients underwent HT with the IABP turned off (IABP-Off), whereas 18 patients underwent HT with IABP-generated PF (IABP-On). The unmatched IABP-On group experienced shorter organ ischemia times (180 vs. 203 minutes, p = 0.015) and CPB times (104 vs. 116 minutes, p = 0.022). The cohort was propensity matched according to age, organ ischemia time, and CPB time. Elevations in postoperative lactates in the immediate (2.8 vs. 1.5, p = 0.062) and 24 hour (4.7 vs. 2.4, p = 0.084) postoperative periods trended toward significance in the matched IABP-Off group. There was no difference in postoperative vasoactive inotropic score (VIS), postoperative creatinine, or length of stay. This limited preliminary data suggest that maintaining counterpulsation to generate PF during CPB may improve end-organ perfusion in this patient population as suggested by lower postoperative lactate levels.

14.
JTCVS Open ; 17: 55-63, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420551

RESUMO

Background: The use of rapid-deployment valves (RDVs) has been shown to reduce the operative time for surgical aortic valve replacement (AVR). Long-term core laboratory-adjudicated data are scarce, however. Here we report final 7-year data on RDV use. Methods: TRANSFORM was a prospective, nonrandomized, multicenter, single-arm trial implanting a stented bovine pericardial valve with an incorporated balloon-expandable sealing frame. A prior published 1-year analysis included 839 patients from 29 centers. An additional 46 patients were enrolled and implanted, for a total of 885 patients. Annual clinical and core laboratory-adjudicated echocardiographic outcomes were collected through 8 years. Primary endpoints were structural valve deterioration (SVD), all-cause reintervention, all-cause valve explantation, and all-cause mortality. Secondary endpoints included hemodynamic performance assessed by echocardiography. The mean duration of follow-up was 5.0 ± 2.0 years. Results: The mean patient age was 73.3 ± 8.2 years. Isolated AVR was performed in 62.1% of the patients, and AVR with concomitant procedures was performed in 37.9%. Freedom from all-cause mortality at 7 years was 76.0% for isolated AVR and 68.2% for concomitant AVR. Freedom from SVD, all-cause reintervention, and valve explantation at 7 years was 97.5%, 95.7%, and 97.8%, respectively. The mean gradient and effective orifice area at 7 years were 11.1 ± 5.3 mm Hg and 1.6 ± 0.3 cm2, respectively. Paravalvular leak at 7 years was none/trace in 88.6% and mild in 11.4%. In patients undergoing isolated AVR, the cumulative probability of pacemaker implantation was 13.9% at 30 days, 15.5% at 1 year, and 21.8% at 7 years. Conclusions: AVR for aortic stenosis using an RDV is associated with low rates of late adverse events. This surgical pericardial tissue platform provides excellent and stable hemodynamic performance through 7 years.

15.
Artigo em Inglês | MEDLINE | ID: mdl-38950755

RESUMO

BACKGROUND: Latent left ventricular outflow tract obstruction (LVOTO) is an important cause of symptoms in patients with hypertrophic cardiomyopathy (HCM) but can be challenging to provoke. OBJECTIVES AND METHODS: To examine the value of postprandial resting and stress echocardiography and utilization of invasive or enhanced drug therapies (surgical myectomy, alcohol septal ablation, disopyramide and mavacamten) in patients with postprandial LVOTO. Consecutive HCM patients without LVOTO underwent routine and postprandial echocardiography at rest, with provocation (Valsalva and standing) and after symptom-limited treadmill stress. RESULTS: Among 252 patients (mean age 58 years, 39% women), postprandial LVOT gradients were higher compared with routine echocardiography at rest (median 9.0 [0-38.0] vs 0 [0-14.0] mmHg, p<0.0001) and with provocation (18.5 [0-70.3] vs 1.5 [0-41.0] mmHg, p<0.0001). Postprandial exercise (PPXSE) gradients were higher in a subset of 44 patients who underwent both postprandial and fasting stress echocardiography, (47.0 [5.3-81.0] vs 17.5 [0-46.0] mmHg, p<0.0001). In total, 49 (19.5%) patients achieved the ≥50 mmHg threshold under routine conditions (rest/provocation); 90 (35.7%) additional patients achieved postprandial gradients ≥50 mmHg (rest/provocation/exercise), 38 (15.1%) with PPXSE alone. A total of 71 patients were treated with 91 invasive or enhanced drug therapies, 32 (45.1%) of whom had gradients ≥50 mmHg only after eating (rest/provocation) and 8 (11.3%) only with PPXSE, with symptom relief in the majority. CONCLUSIONS: Postprandial echocardiography was useful at unmasking LVOTO in more than one third of patients who did not have high gradients otherwise. Eating before echocardiography is a powerful provocative tool in the evaluation of patients with HCM.

16.
JTCVS Tech ; 22: 23-27, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38152165

RESUMO

Objective: Totally endoscopic intracardiac robotic surgery is generally limited to uncomplicated mitral valve surgery. With experience, our team has developed a more aggressive approach to robotic cardiac surgery that allows for repair of a broad spectrum of mitral valve pathologies. We report complex subvalvular procedural advancements associated with this approach secondary to enhanced team experience and capabilities. Methods: All robotic mitral procedures performed by a 2-surgeon team in a quaternary care medical center from July 2011 to May 2022 were reviewed. Natural language-processing techniques were used to analyze operative reports for subvalvular repair techniques. Complex subvalvular techniques included papillary muscle repositioning, division of secondary anterior leaflet chordae, septal myomectomy, division of aberrant left ventricular muscle band attachments, and left ventricular patch reconstruction. The surgical experience was divided into 2 periods: early robotic experience (pre-2018) versus late (2018 onwards). Baseline demographics, outcomes, and subvalvular techniques were analyzed and compared. Results: A total of 1287 intracardiac robotic operations were performed by a 2-surgeon team. Thirty-day mortality was 0.6% (8/1287). Mitral valve repair was performed in 1024 patients. The mean age was 61 years (range, 18-90 years), and 15% were >75 years old; 29 patients (2.8%) had previously undergone cardiac surgery. There was a significant increase with experience in the application of advanced subvalvular techniques between the early versus late period (52.3% [268/512] vs 74.2% [380/512] (P < .001)). Conclusions: An experienced 2-surgeon team can perform progressively more complex robotic subvalvular repair techniques. These subvalvular techniques are a surrogate for team proficiency and capabilities.

17.
Innovations (Phila) ; 18(4): 338-345, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37458243

RESUMO

OBJECTIVE: Endoaortic balloon occlusion facilitates cardioplegic arrest during minimally invasive surgery (MIS). Studies have shown endoclamping to be as safe as traditional aortic clamping. We compared outcomes and hospital costs of endoclamping versus external aortic occlusion in a large administrative database. METHODS: There were 52,882 adults undergoing eligible cardiac surgery (October 2015 to March 2020) identified in the Premier Healthcare Database. Endoclamp procedures (n = 419) were 1:3 propensity score matched to similar procedures using external aortic occlusion (n = 1,244). Generalized linear modeling measured differences in in-hospital complications (major adverse renal and cardiac events, including mortality, new-onset atrial fibrillation, acute kidney injury [AKI], myocardial infarction [MI], postcardiotomy syndrome, stroke/transient ischemic attack [TIA], and aortic dissection) and length of stay (LOS). RESULTS: The mean age was 63 years, and 53% were male (n = 882). The majority (93%, n = 1,543) were mitral valve procedures, and 17% of procedures (n = 285) were robot-assisted. Total hospitalization costs were not statistically significantly different between the 2 groups ($52,158 vs $49,839, P = 0.06). The median LOS was significantly shorter in the endoclamp group (incident rate ratio = 0.87, P < 0.001). Mortality, atrial fibrillation, AKI, and stroke/TIA were similar between the 2 groups. MI and postcardiotomy syndrome were lower in the endoclamp group (odds ratio [OR] = 0.14, P = 0.006, and OR = 0.27, P = 0.005). There were no aortic dissections in the endoclamp group. CONCLUSIONS: Aortic endoclamping in MIS was associated with similar costs, shorter LOS, no dissections, and comparably low mortality and stroke rates when compared with external clamping in this hospital billing dataset. These results demonstrate the clinical safety and efficacy of endoaortic balloon clamping in a real-world setting. Further studies are warranted.


Assuntos
Injúria Renal Aguda , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Ataque Isquêmico Transitório , Infarto do Miocárdio , Acidente Vascular Cerebral , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Ataque Isquêmico Transitório/etiologia , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Injúria Renal Aguda/etiologia , Resultado do Tratamento , Estudos Retrospectivos
18.
Artigo em Inglês | MEDLINE | ID: mdl-37360841

RESUMO

Background: Evidence suggests that patients critically ill with COVID-19 have a dysregulated host immune response that contributes to end-organ damage. Extracorporeal membrane oxygenation (ECMO) has been used in this population with varying degrees of success. This study was performed to evaluate the impact of ECMO on the host immunotranscriptomic response in these patients. Methods: Eleven patients critically ill with COVID-19 requiring ECMO underwent an analysis of cytokines and immunotranscriptomic pathways before ECMO (T1), after ECMO for 24 hours (T2), and 2 hours after ECMO decannulation (T3). A Multiplex Human Cytokine panel was used to identify cytokine changes, and immunotranscriptomic changes in peripheral leukocytes were evaluated by PAXgene and NanoString nCounter. Results: Differential gene expression of 11 host immune genes was noted at T2 compared with T1. The most significant genes were MD2 and MRC1, which code for binding ligands for the activation of toll-like receptors 2 and 4. Reactome analyses of differential gene expression demonstrated an impact on many of the body's most important immune inflammatory pathways. Conclusions: These findings suggest a temporal impact of ECMO on the host immunotranscriptomic response in patients critically ill with COVID-19.

19.
Ann Thorac Surg ; 114(1): 70-75, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35282865

RESUMO

BACKGROUND: Severe coronavirus disease 2019 (COVID-19) can cause acute respiratory failure requiring mechanical ventilation. Venovenous (VV) extracorporeal membrane oxygenation (ECMO) has been used in patients in whom conventional mechanical ventilatory support has failed. To date, published data have focused on survival from ECMO and survival to discharge. In addition to survival to discharge, this study reports 1-year follow-up data for patients who were successfully discharged from the hospital. METHODS: A single-institution, retrospective review of all patients with severe COVID-19 who were cannulated for VV-ECMO between March 10, 2020 and May 1, 2020 was performed. A multidisciplinary ECMO team evaluated, selected, and managed patients with ECMO support. The primary outcome of this study was survival to discharge. Available 1-year follow-up data are also reported. RESULTS: A total of 30 patients were supported with VV-ECMO, and 27 patients (90%) survived to discharge. All patients were discharged home or to acute rehabilitation on room air, except for 1 patient (3.7%), who required supplemental oxygen therapy. At a median follow-up of 10.8 months (interquartile range [IQR], 8.9-14.4 months) since ECMO cannulation, survival was 86.7%, including 1 patient who underwent lung transplantation. Of the patients discharged from the hospital, 44.4% (12/27) had pulmonary function testing, with a median percent predicted forced expiratory volume of 100% (IQR, 91%-110%). For survivors, a 6-minute walk test was performed in 59.3% (16/27), with a median value of 350 m (IQR, 286-379 m). CONCLUSIONS: A well-defined patient selection and management strategy of VV-ECMO support in patients with severe COVID-19 resulted in exceptional survival to discharge that was sustained at 1-year after ECMO cannulation.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Síndrome do Desconforto Respiratório , COVID-19/terapia , Oxigenação por Membrana Extracorpórea/métodos , Humanos , Respiração Artificial , Estudos Retrospectivos
20.
J Thorac Cardiovasc Surg ; 161(1): 80-88, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31983525

RESUMO

OBJECTIVE: Mitral annular calcification is underdiagnosed in patients with mitral regurgitation. After excision, it may require reconstruction of the atrioventricular groove and decreases the probability of valve repair. We reviewed the safety and efficacy of totally endoscopic robotic mitral valve repair in the presence of mitral annular calcification, with an emphasis on pathology and repair techniques. METHODS: Between May 2011 and August 2017, the same 2-surgeon team attempted totally endoscopic robotic mitral valve repair in 64 mitral annular calcification cases, accounting for 12.8% of our experience. Mitral annular calcification associated with a calcified posterior leaflet was not considered for totally endoscopic robotic mitral valve repair. When possible, the mitral annular calcification was excised en bloc using electrocautery, the posterior leaflet separated from the mitral annular calcification and spared, the atrioventricular groove was reconstructed, the posterior leaflet was reattached to the neoannulus, and the repair was completed with annuloplasty. RESULTS: The median age of patients was 65 years, with 21 (32.8%) aged less than 60 years, and 34 (53.1%) were women. The etiology was Barlow's disease in 54 patients (84%). Repair was converted to replacement in 2 patients (3.1%). Cryoablation was performed in 8 patients (12.5%), hybrid percutaneous coronary intervention was performed in 5 patients (7.8%), and tricuspid annuloplasty was performed in 2 patients (3.1%). Median aortic occlusion was 122 minutes, excluding cases with concomitant tricuspid repair. Thirty-three patients (52%) were extubated in the operating room. The median length of stay was 4 days. Residual mitral regurgitation on discharge transthoracic echocardiogram was none to mild in all patients. None of the patients had a perioperative stroke or needed a pacemaker. Thirty-day mortality was 2 (3.1%). CONCLUSIONS: Mitral annular calcification is present in a significant percentage of patients with mitral regurgitation, especially in Barlow's disease, including younger patients. By using a variety of repair techniques, totally endoscopic robotic mitral valve repair can be performed safely and effectively in most mitral annular calcification cases with a noncalcified posterior leaflet.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA