Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Arch Orthop Trauma Surg ; 139(5): 645-650, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30715568

RESUMO

INTRODUCTION: Several different systems of classification have been developed to understand the complexity of pelvic ring fractures, to facilitate communication between physicians and to support the selection of appropriate therapeutic measures. The purpose of this study was to measure the inter- and intraobserver reliability of Tile AO, Young and Burgess, and FFP classification in pelvic ring fractures. The Rommens classification system (FFP) is analyzed for the first time. MATERIALS AND METHODS: Four reviewers (2 × senior pelvic trauma surgeon, 1 × resident, 1 × medical student) separately analyzed and classified 154 CT scans of patients with pelvic fracture. The Tile AO, the Young and Burgess, and the FFP classifications (subgroup with patients ≥ 60 years) were compared. Another blinded re-evaluation was carried out after 2 months to determine intraobserver reliability. RESULTS: The overall interobserver agreement was fair for all classification systems (ICC: OTA 0.55, Young and Burgess 0.42, FFP 0.54). For specific categories, (e.g. type B or C fractures), there was a substantial agreement between the experienced surgeons (kappa: OTA 0.64, Young and Burgess 0.62, FFP 0.68). For inexperienced observers, there was a fair agreement in all systems (kappa: OTA 0.23, Young and Burgess 0.23, FFP 0.36). CONCLUSIONS: All three classifications reach their maximum reliability with advanced expertise in the surgery of pelvic fractures. The novel FFP classification has proved to be at least equivalent when directly compared to the established systems. The FFP classification system showed substantial reliability in patients older than 60 years.


Assuntos
Fraturas Ósseas/classificação , Fraturas Ósseas/diagnóstico por imagem , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/lesões , Sacro/diagnóstico por imagem , Sacro/lesões , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
2.
Acta Orthop ; 89(5): 580-584, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29947288

RESUMO

Background and purpose - Cutibacterium acnes, formerly known as Propionibacterium acnes, is often isolated from deep tissues of the shoulder. It is recognized as an important causative agent of foreign-material associated infections. However, the incidence and significance of its detection in tissues from patients without clinical evidence for infection is unclear. We assessed the incidence of C. acnes colonization of osteosynthesis material in asymptomatic patients, and evaluated the short-term outcome in relation to the microbiological findings. Patients and methods - We microbiologically analyzed osteosynthesis material of 34 asymptomatic patients after surgery on the clavicle. Material obtained from 19 asymptomatic patients after osteosynthesis of the fibula served as a control group. Patients were clinically followed up for 3-24 months after removal of the osteosynthesis material. Results - Bacteria were recovered from devices in 29 of 34 patients from the clavicle group. 27 of 29 positive samples grew C. acnes. Isolation of C. acnes was more common in male than in female patients. No bacterial growth was observed on foreign material from patients in the fibula group. All patients remained asymptomatic at follow-up. Interpretation - Growth of C. acnes is common on osteosynthesis material of the shoulder, especially in males. Samples were positive irrespective of clinical signs of infection. Therefore, detection of C. acnes in this clinical setting is of questionable clinical significance. The high positivity rate in asymptomatic patients discourages routine sampling of material in cases without clinical evidence for infection.


Assuntos
Placas Ósseas/microbiologia , Fixação Interna de Fraturas/instrumentação , Propionibacterium acnes/isolamento & purificação , Fraturas do Ombro/cirurgia , Articulação do Ombro/microbiologia , Adulto , Idoso , Parafusos Ósseos/microbiologia , Clavícula/lesões , Clavícula/cirurgia , Remoção de Dispositivo , Contaminação de Equipamentos , Feminino , Fíbula/lesões , Fíbula/cirurgia , Seguimentos , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Propionibacterium acnes/crescimento & desenvolvimento , Articulação do Ombro/cirurgia , Adulto Jovem
3.
Knee Surg Sports Traumatol Arthrosc ; 25(7): 2025-2031, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26685688

RESUMO

PURPOSE: To evaluate different stabilisation techniques for acromioclavicular (AC) joint separations, including direct AC repair, and to compare the properties of the stabilised and native joints. METHODS: An established in vitro testing model for the AC joint was used to analyse joint stability after surgical reconstruction [double TightRope (DTR), DTR with AC repair (DTR + AC), single TR with AC repair (TR + AC), and PDS sling with AC repair (PDS + AC)]. Twenty-four human cadaveric shoulders were randomised by age into four testing groups. Joint stiffness was measured by applying an axial load during defined physiological ranges of motion. Similar tests were performed for the native joints, after dissecting the coracoclavicular and AC ligaments, and after surgical reconstruction. Cyclic loading was performed for 1000 cycles with 20-70 N and vertical load to failure determined after cyclic testing. RESULTS: Axial stiffness for all TR groups was significantly higher than for the native joint (DTR 38.94 N/mm, p = 0.005; DTR + AC 37.79 N/mm, p = 0.015; TR + AC 45.61 N/mm, p < 0.001 vs. native 26.05 N/mm). The axial stiffness of the PDS + AC group was similar to that of the native joint group (21.4 N/mm, n.s.). AC repair did not significantly influence rotational stiffness. Load to failure was similar and >600 N in all groups (n.s.). CONCLUSION: Reconstruction of AC dislocations with one or two TRs leads to stable results with a higher stiffness than the native joints. For the PDS + AC group, axial stiffness was similar to the native situation, although there might be a risk of elongation. Direct AC repair showed no significantly increased stability in comparison with reconstructions without direct AC repair. Thus, a direct AC repair seems to be dispensable in clinical practice, while TRs or PDS cerclages appear to provide sufficiently stable results.


Assuntos
Articulação Acromioclavicular/cirurgia , Luxações Articulares/cirurgia , Ligamentos Articulares/cirurgia , Teste de Materiais , Dispositivos de Fixação Ortopédica , Fita Cirúrgica , Adulto , Idoso , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Instabilidade Articular/cirurgia , Masculino , Pessoa de Meia-Idade , Distribuição Aleatória , Suporte de Carga
4.
Knee Surg Sports Traumatol Arthrosc ; 24(4): 1180-6, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25895834

RESUMO

PURPOSE: Acute ankle sprains are frequently accompanied by syndesmotic injuries. These injuries are often overlooked in clinical examinations. The aim of this study was (1) to evaluate the incidence of syndesmotic injuries in acute ankle sprains using MRI, (2) to determine the accuracy of common clinical diagnostic tests, (3) to analyse their inter-rater reliability, and (4) to evaluate the role of clinical symptoms in the diagnosis of syndesmotic injuries. METHODS: A total of 100 patients with acute ankle sprain injury without associated fractures in plane radiographs were enrolled. The clinical assessment was performed by two independent examiners. Local findings, ankle ligament palpation, squeeze test, external rotation test, Drawer test, Cotton test, and the crossed-leg test (two examiners) were compared with MRI results (read by two blinded radiologists) as a reference standard. RESULTS: Ninety-six participants (57% male) met the inclusion criteria. MRI detected a ruptured anterior inferior tibiofibular ligament (AITFL) in 14 patients (15%); 9 partial tears and 5 complete tears were evident. Evidence of pain at rest was found to predict syndesmotic injuries most accurately (p = 0.039). The palpation test over the proximal fibula produced the highest inter-rater correlation (κ = 0.65), but the lowest sensitivity for syndesmotic injuries of 8%. All other clinical tests demonstrated moderate to fair inter-rater reliabilities (κ = 0.37-0.52). Low sensitivity values were found with all clinical tests (13.9-55.6%). CONCLUSION: In this study, clinical examination was insufficient to detect syndesmotic injuries in acute ankle sprains. MRI scanning revealed a syndesmotic lesion in 15% of patients. MRI scanning should be recommended in patients with ongoing pain at rest following ankle sprains. LEVEL OF EVIDENCE: I.


Assuntos
Traumatismos do Tornozelo/diagnóstico , Ligamentos Articulares/lesões , Imageamento por Ressonância Magnética , Palpação , Entorses e Distensões/diagnóstico , Adolescente , Adulto , Feminino , Humanos , Ligamentos Articulares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Exame Físico , Reprodutibilidade dos Testes , Adulto Jovem
5.
Arch Orthop Trauma Surg ; 136(7): 913-9, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27155882

RESUMO

INTRODUCTION: At the present time, it is generally recommended to use hip replacement in dislocated fractures to avoid failure after internal fixation. A problem is that previous research has demonstrated that observers have problems in discriminating between dislocated and undislocated fractures. A possible solution to this problem would be to use arthroplasty in the majority of the cases. However, this also means that many fractures with the potential for uneventful healing would be replaced. MATERIALS AND METHODS: In the current investigation, the mid-term outcome was recorded for patients with intracapsular hip fractures who were treated with either internal fixation or arthroplasty. A novel treatment algorithm was employed. After careful exclusion of cases with known risk factors for failure after internal fixation, a technique called on-table decision was used to identify suitable patients for internal fixation. RESULTS: A total of 72 patients with intracapsular hip fractures were studied with a median follow-up time of 12 months (IQR 8-15.25 months). Nineteen (19) patients (26 %) were excluded in the selection process, leaving 53 (74 %) for on-table decision-making. Thirty patients (42 %) were identified as suitable for internal fixation and gave anatomically stable closed reductions. Two of these patients (7 %) exhibited non-unions and one (3 %) avascular necrosis. CONCLUSIONS: The mid-term outcome after internal fixation is promising. The careful selection process may be helpful in identifying fracture patterns for which internal fixation may be considered as a safe and less invasive alternative to hip arthroplasty.


Assuntos
Artroplastia de Quadril/métodos , Fixação Interna de Fraturas/métodos , Fraturas do Quadril/cirurgia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artroplastia de Quadril/efeitos adversos , Tomada de Decisões , Feminino , Seguimentos , Fixação Interna de Fraturas/efeitos adversos , Humanos , Cápsula Articular/cirurgia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Fatores de Risco
6.
Clin Orthop Relat Res ; 472(11): 3395-403, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25141842

RESUMO

BACKGROUND: Acetabular fractures and surgical interventions used to treat them can result in nerve injuries. To date, only small case studies have tried to explore the frequency of nerve injuries and their association with patient and treatment characteristics. High-quality data on the risk of traumatic and iatrogenic nerve lesions and their epidemiology in relation to different fracture types and surgical approaches are lacking. QUESTIONS/PURPOSES: The purpose of this study was to determine (1) the proportion of patients who develop nerve injuries after acetabular fracture; (2) which fracture type(s) are associated with increased nerve injury risk; and (3) which surgical approach was associated with the highest proportion of patients developing nerve injuries using data from the German Pelvic Trauma Registry. Two secondary aims were (4) to assess hospital volume-nerve-injury relationship; and (5) internal data validity. METHODS: Between March 2001 and June 2012, 2236 patients with acetabular fractures were entered into a prospectively maintained registry from 29 hospitals; of those, 2073 (92.7%) had complete records on the endpoints of interest in this retrospective study and were analyzed. The neurological status in these patients was captured at their admission and at the discharge. A total of 1395 of 2073 (67%) patients underwent surgery, and the proportions of intervention-related and other hospital-acquired nerve injuries were obtained. Overall proportions of patients developing nerve injuries, risk based on fracture type, and risk of surgical approach type were analyzed. RESULTS: The proportion of patients being diagnosed with nerve injuries at hospital admission was 4% (76 of 2073) and at discharge 7% (134 or 2073). Patients with fractures of the "posterior wall" (relative risk [RR], 2.0; 95% confidence interval [CI], 1.4-2.8; p=0.001), "posterior column and posterior wall" (RR, 2.9; CI, 1.6-5.0; p=0.002), and "transverse+posterior wall" fracture (RR, 2.1; CI, 1.3-3.5; p=0.010) were more likely to have nerve injuries at hospital discharge. The proportion of patients with intervention-related nerve injuries and that of patients with other hospital-acquired nerve injuries was 2% (24 of 1395 and 46 of 2073, respectively). They both were associated with the Kocher-Langenbeck approach (RR, 3.0; CI, 1.4-6.2; p=0.006; and RR, 2.4; CI, 1.4-4.3; p=0.004, respectively). CONCLUSIONS: Acetabular fractures with the involvement of posterior wall were most commonly accompanied with nerve injuries. The data suggest also that Kocher-Langenbeck approach to the pelvic ring is associated with a higher risk of perioperative nerve injuries. Trauma surgeons should be aware of common nerve injuries, particularly in posterior wall fractures. The results of the study should help provide patients with more exact information on the risk of perioperative nerve injuries in acetabular fractures. LEVEL OF EVIDENCE: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Acetábulo/lesões , Acetábulo/cirurgia , Fraturas Ósseas/epidemiologia , Fraturas Ósseas/cirurgia , Traumatismos dos Nervos Periféricos/epidemiologia , Comorbidade , Intervalos de Confiança , Medicina Baseada em Evidências , Feminino , Fixação Interna de Fraturas/efeitos adversos , Fraturas Ósseas/classificação , Alemanha/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prevalência , Sistema de Registros , Estudos Retrospectivos , Medição de Risco
7.
Knee Surg Sports Traumatol Arthrosc ; 22(9): 2237-42, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23860864

RESUMO

PURPOSE: A novel radiation-free electromagnetic navigation system (ENS)-based method was developed, and its feasibility and accuracy for transclavicular-transcoracoid drilling procedures were evaluated in an experimental setting. METHODS: Sixteen arthroscopically assisted electromagnetic navigated transcoracoid-transclavicular drilling procedures with subsequent TightRope device implantation were performed on eight human cadavers. Post-operative fluoroscopy and CT-scan analysis were acquired to determine tunnel placement accuracy. Optimal tunnel placement was defined as both the coracoid entry and exit point of the tunnel localized in the centre position of the coracoid base without cortical breach or fracture. RESULTS: Successful tunnel placement was accomplished in all 16 cases. The mean overall operation time was 30.3 ± 5.0 min. Regarding the coracoid exit point, 15 of 16 tunnels (93.8%) were localized in the desired base-centre position. During the navigated drilling procedure, no misguidance of the drill requiring directional readjustments or restarts occurred. No cortical breach, no fractures and no complications occurred. CONCLUSIONS: The electromagnetically navigated transcoracoid-transclavicular drilling procedure used in this study demonstrated high targeting accuracy, required no intraoperative radiographs, was associated with no complications and provided user-friendliness.


Assuntos
Articulação Acromioclavicular/cirurgia , Clavícula/cirurgia , Escápula/cirurgia , Articulação Acromioclavicular/lesões , Adulto , Artroscopia , Cadáver , Clavícula/diagnóstico por imagem , Fenômenos Eletromagnéticos , Estudos de Viabilidade , Fluoroscopia , Humanos , Implantação de Prótese , Escápula/diagnóstico por imagem , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X
8.
North Clin Istanb ; 9(4): 414-418, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36276575

RESUMO

Magnetic resonance imaging (MRI) is a technique useful for the diagnosis of cartilage damage due to high sensitivity to identify subchondral bone abnormalities and full-thickness cartilage lesions. The lack of a study on knee cartilage changes over time in patients with osteoarthritis (OA) by MRI technique led us to investigate the accuracy of MRI in identifying knee cartilage changes over time in patients with OA in a systematic review. In the present systematic review, started from the beginning of 2020 in one of the University Hospitals in Iran, the databases of CINAHL, Ovid, Elsevier, Scopus, PubMed, Science Direct, and Web of Science were searched using the keywords MRI, OA, Cartilage Lesion, Imaging Techniques. A total of 169 articles were retrieved in the initial search, and after reviewing the titles, abstracts, and full-texts, finally, seven were enrolled in the systematic review. Review of the selected papers showed that a total of 1091 subjects were studied, of which 355 were males. The results of all the studies, except one, indicated the high accuracy of MRI to identify knee cartilage changes over time. MRI technique can show cartilage changes with high accuracy in patients with knee OA over time. We proved the potential of MRI to identify articular cartilage injuries in patients with OA and its importance to the evaluation of articular cartilage lesions along with other available techniques.

9.
Eur J Trauma Emerg Surg ; 48(5): 3635-3641, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32415366

RESUMO

PURPOSE: The role of classification systems for the choice of surgical approach and the management of tibial plateau fractures remains unclear. The purpose of this study was to investigate the potential of classification systems to choose the appropriate operative approach. Current surgical management strategies were investigated in a large multicenter assessment. METHODS: In this study, we retrospectively analyzed all patients with tibial plateau fractures that have received surgical treatment in one of the five Level I trauma facilities between 2012 and 2015. Fractures were classified in each center by a senior orthopedic surgeon using the AO/OTA and the Luo classification. Demographics, trauma mechanism, as well as the surgical approach were recorded. RESULTS: 538 patients (46.1% male, 53.9% female) were included. The anterolateral approach was used most frequently with 54.8% of all single approaches; 76.2% of all combined approaches used anterolateral as part of the approach. Combined approaches were used in 22.5% of the cases; a combination of the anterolateral and medial (10%), anterolateral, and posteromedial approach (5.8%) were used most frequently. The lowest number was found for the posterolateral (1.3%) and the combined approaches dorsal/anterolateral and medial/dorsal (1.7%, 1.1%). The AO/OTA classification showed a peak for 41.B2 (21.9%) and B3 (35.5%) fractures. Regarding the Luo classification, the dorsal column was involved in 45.7%. In contrast, only 14.7% of the surgical approaches used were able to address the dorsal tibial plateau potentially. CONCLUSION: The use of dorsal approach seems to be of minor importance than expected in daily clinical practice in this multicenter study. It was not possible to specify whether the AO/OTA or the Luo classification can reliably predict the choice of surgical approach. The operative treatment strategy of tibial plateau fractures seems to rather rely on the surgeons' experience, education, and preferences.


Assuntos
Fixação Interna de Fraturas , Fraturas da Tíbia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Tíbia/cirurgia , Fraturas da Tíbia/cirurgia
10.
J Trauma ; 70(4): E62-6, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21613972

RESUMO

BACKGROUND: There are a number of biomechanical tests for various treatment options of periprosthetic femoral fractures, but different loading modalities prelude their direct comparison. This study was designed to develop an experimental model of osteoporotic bone fractures near the femoral stem that is based on a simple testing protocol to increase the reproducibility. In addition, we wanted to clarify whether a femoral prosthetic stem reduces the femoral fracture strength. METHODS: Twenty human cadaveric femurs were harvested, and five groups were randomized on the basis of the bone mineral density using a pQCT device. The specimens of three groups were provided with a cemented Exeter V40 stem and loaded to failure with torsion (I), anterior (II), and lateral load (III). The femurs of groups IV and V remained uninstrumented and were tested in a four-point bending assay similar to groups II and III. All biomechanical testings were realized with a servohydraulic testing machine (MTS). RESULTS: There was no significant difference regarding bone mineral density of all groups. Torsional testing generated proximal intertrochanteric fractures and anterior loading resulted exclusively in supracondylar fractures. Introducing the force from the lateral side, all fracture lines occurred close to the tip of the stem, similar to a Vancouver-B fracture. Assuming that lateral load application is a main responsible mechanism of periprosthetic femoral fracture near the tip of the stem, the fracture strength of instrumented femurs was significantly reduced (group III: 4,692 N vs. group V: 6,931 N; p < 0.05). CONCLUSION: Prosthetic stems reduce femoral fracture strength significantly. In an osteoporotic bone model, a four-point bending test with lateral load application seems to be a suitable approach.


Assuntos
Fraturas do Fêmur/fisiopatologia , Prótese de Quadril/efeitos adversos , Fraturas Periprotéticas/fisiopatologia , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Densidade Óssea , Cadáver , Feminino , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/metabolismo , Humanos , Masculino , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/metabolismo , Falha de Prótese
11.
J Trauma ; 71(3): 625-34, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21768904

RESUMO

BACKGROUND: First introduced in 2005, the "Intertan" (IT), an intramedullary nail with two cephalocervical screws, has become an increasingly popular option for treating intertrochanteric fractures. The purpose of this study was to identify the utility of this device for stabilization of unstable femoral neck fractures compared with cannulated screws (CS) and a dynamic hip screw (DHS). METHODS: Twenty-four human cadaveric femurs were harvested and assigned to three groups that were matched with regard to bone mineral density (BMD). Standardized Pauwels-Type-III fractures were osteomized with a custom-made saw guide and fixated by an "IT," three CS, or a DHS. All constructs were biomechanically tested in a servohydraulic testing machine with a physiologic mechanical axis loading of the femoral head (700 N), cyclical compression to 1,400 N (10,000 cycles; 2 Hz), and loading to failure. All specimens were compared with respect to the number of survived cycles, mechanical strength, head displacement, load to failure, and failure mechanism. RESULTS: Regardless of the fixation, the mechanical strength of the stabilized femurs was significantly decreased to 71% compared with the intact femurs (100%). During cyclical testing 46% of the constructs (6 CS, 4 DHS, and 1 IT) failed. There was no difference between the mechanical strength of all survived constructs regarding the BMD, but the BMD of the failed specimens was significantly reduced compared with the surviving femurs (0.71 g/cm² ± 0.18 g/cm² vs. 1.07 g/cm² ± 0.33 g/cm²; p < 0.05). IT femurs survived significantly longer than CS specimens (IT, 9,063 cycles ± 2,480 cycles vs. CS, 3,325 cycles ± 3,885 cycles vs. DHS, 5,716 cycles ± 4,448 cycles; p < 0.01), endured higher failure loads (IT, 4,929 N ± 1,105 N vs. CS, 3,421 N ± 20 N vs. DHS, 3,505 N ± 905 N; p < 0.05), and presented a less inferior head displacement (IT, 8.5 mm ± 1.6 mm vs. CS, 16.4 mm ± 6.7 mm vs. DHS, 14.5 mm ± 6.4 mm; p < 0.05). CONCLUSION: Our results suggest that (1) none of the tested devices restore a comparable mechanical strength in the fractured specimens compared with the intact femurs, and (2) the "IT" possesses some biomechanical benefits for internal fixation of unstable femoral neck fractures compared with DHS and CS. Because the IT constructs failed with an inferior femoral neck fracture, complicating the mandatory anchorage of a prosthetic stem in a revision operation, more biomechanical experiments using the IT in the presence of a posterior comminution defect are required, along with clinical outcome studies.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral/cirurgia , Fixação Interna de Fraturas/instrumentação , Fixadores Internos , Adulto , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Cadáver , Análise de Falha de Equipamento , Feminino , Fraturas do Colo Femoral/patologia , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Maleabilidade , Suporte de Carga
12.
J Trauma ; 71(4): 926-32, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21610540

RESUMO

BACKGROUND: The purpose of this study was to assess the feasibility and accuracy of computer-assisted surgery (CAS) for screw placement in different pelvic regions using intraoperative three-dimensional (3D) imaging and to evaluate the influence of surgeons' experience with such a system on procedure time, radiation time, radiation dose, and misplacement rate. METHODS: Experimental study in a human cadaveric model (n=5) for percutaneous screw placement in the anterior column of the acetabulum, the posterior pelvic ring (S1, S2), and the superior pubic ramus via 3D fluoroscopic navigated procedure. Accuracy of screw placement was assessed by 3D image intensifier, including the reconstruction of multiplanar images and by computer tomography (CT) scan. Influence of surgeons' experience was assessed by direct comparison of a low- and high-volume surgeon using the same technical setting. RESULTS: In 100% of all procedures, intraoperative Iso-C3D image analysis was sufficient to confirm a correct screw placement. The postoperative CT scan revealed no further screw misplacement. However, for a correct supraacetabular screw placement, the intraoperative 3D scan was essential. In this group, the 3D scan showed screw misplacement in three cases. Procedure time for all indications and screw failure rate were significantly lower for the higher experienced surgeon. CONCLUSION: The 3D fluoroscopic navigated procedure in pelvic surgery seems to be a useful tool for all surgeons and especially for less experienced ones. Furthermore, the intraoperative reconstruction of multiplanar 3D images allows a secure control of implant positioning.


Assuntos
Parafusos Ósseos , Imageamento Tridimensional/métodos , Ossos Pélvicos/cirurgia , Cirurgia Assistida por Computador/métodos , Acetábulo/lesões , Acetábulo/cirurgia , Fluoroscopia/métodos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Humanos , Período Intraoperatório , Ossos Pélvicos/lesões , Tomografia Computadorizada por Raios X/métodos
13.
Int Orthop ; 35(9): 1391-6, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20640933

RESUMO

Correct placement of iliosacral screws remains a surgical challenge. The aim of this retrospective study was to identify parameters which impact the accuracy of this technically demanding procedure. Eighty-two patients with vertically unstable pelvic injuries treated with a total of 147 iliosacral screws were included. Assessment of postoperative CT scans revealed screw misplacement in 13 cases (8%), of which six occurred following insertion of two unilateral screws into S1. Six screw misplacements occurred in patients with dislocation injuries of the posterior pelvis. Comparison of a navigated and the standard technique revealed a decreased screw misplacement rate in the navigated group (15% standard vs. 3% navigation, p < 0.05). In addition, the malposition rate was influenced by the surgeon's individual experience (20% for low vs. 3.9% for high volume surgeons, p < 0.05). Overall, the accuracy of iliosacral screw placement depends on the number of screws inserted into S1 and the extent of dislocation. In experienced hands, the use of navigation represents a helpful tool to improve the placement accuracy.


Assuntos
Parafusos Ósseos/efeitos adversos , Ílio/cirurgia , Erros Médicos/prevenção & controle , Ossos Pélvicos/lesões , Implantação de Prótese/métodos , Sacro/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Falha de Equipamento , Feminino , Humanos , Luxações Articulares , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Implantação de Prótese/efeitos adversos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
14.
Int Orthop ; 35(11): 1695-701, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21286918

RESUMO

BACKGROUND AND PURPOSE: Internal fixation is a therapeutic mainstay for treatment of undisplaced femoral neck fractures and fractures without posterior comminution. The best treatment for unstable and comminuted fractures, however, remains controversial, especially in older patients. The present study was designed to assess the utility of the Intertan Nail® (IT) for stabilization of comminuted Pauwels type III fractures compared to dynamic hips screw (DHS). METHODS: Randomized on the basis of bone mineral density, 32 human femurs were assigned to four groups. Pauwels type III fractures were osteomized with a custom-made saw guide. In 16 specimens the posteromedial support was removed and all femurs were instrumented with an IT or a DHS. All constructs were tested with nondestructive axial loading to 700N, cyclical compression to 1,400N (10,000 cycles), and loading to failure. Outcome measures included number of survived cycles, mechanical stiffness, head displacement and load to failure. RESULTS: Postoperative mechanical stiffness and stiffness after cyclical loading were significantly reduced in all constructs regardless of the presence of a comminution defect (p = 0.02). Specimens stabilized with the IT had a lower construct displacement (IT, 8.5 ± 0.5 mm vs. DHS, 14.5 ± 2.2 mm; p = 0.007) and sustained higher failure loads (IT, 4929 ± 419 N vs. DHS, 3505 ± 453 N; p = 0.036) than the DHS constructs. INTERPRETATION: In comminuted Pauwels type III fractures, the fixation with the IT provided sufficient postoperative mechanical strength, comparable rate of femoral head displacement, and a similar tolerance of physiological loads compared to fractures without comminution. The absence of the posteromedial support in comminuted fractures tended to reduce the failure load regardless of the fixation method.


Assuntos
Pinos Ortopédicos , Parafusos Ósseos , Fraturas do Colo Femoral/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estresse Mecânico , Suporte de Carga/fisiologia
15.
Eur J Trauma Emerg Surg ; 46(1): 107-113, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30030551

RESUMO

INTRODUCTION: The objective of this study is to report the institutions experiences with standardized 2D computer-navigated percutaneous iliosacral screw placement (CNS), as well as the conventional fluoroscopically assisted screw placement method (CF) over a period of 10 years. PATIENTS AND METHODS: A total of 604 patients with sacral fractures (OTA B and C) were treated at the institution. Cases with both, a preoperative and postoperative CT scan were included for further analysis. With this prerequisite, a total of 136 cases were included. The quality of screw positioning, length of operation and intraoperative radiation exposure were recorded and compared. Moreover, it was analyzed whether the presence of dysmorphic sacra influenced the precision of screw positioning. RESULTS: Two hundred and thirty-two screws were implanted in 136 patients (100 navigated, 36 conventional). The duration of the average procedure was similar in the two groups [49.8 min (p = 0.7) conventional group (CF) vs. 48.0 min computer-navigated (CNS) group]. With computer navigation, radiation exposure was significantly reduced by almost half [128.3 vs. 65.2 s (p = 0.023)]. Screw placement was more accurate in the navigation group (79.03% CF vs. 86.47% CNS). The presence of dysmorphic sacral foramina or an increased alar slope increased the incidence of screw malpositioning. CONCLUSION: The conventional percutaneous method and a standardized 2D navigated method have similar rates of malpositioning. Dysmorphic upper sacral foramina and increased alar slope were identified as risk factors for screw malpositioning. Radiation exposure rates were reduced by half when using computer navigation. Therefore, computer navigation in iliosacral screw placement is recommended as method of choice.


Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Ílio/cirurgia , Ossos Pélvicos/lesões , Sacro/cirurgia , Cirurgia Assistida por Computador/métodos , Adolescente , Adulto , Idoso , Feminino , Fluoroscopia , Humanos , Ílio/lesões , Masculino , Pessoa de Meia-Idade , Exposição à Radiação , Sacro/anormalidades , Sacro/lesões , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
16.
Orthop Traumatol Surg Res ; 104(7): 1037-1041, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30243677

RESUMO

BACKGROUND: Gold standard to diagnose osteoporosis is standard dual-energy X-ray absorptiometry (DXA). CT is a standard diagnostic tool to detect injuries to the pelvic ring. The aim of the study was to collect information on bone density without DXA by determination of Hounsfield units (HU) in CT scans of patients with sacral fractures, to draw conclusions on the prevalence of osteoporosis in patients admitted to the investigating institution. HYPOTHESIS: Is the determination of HU in CT scans a useful method to gain more information about bone density in patients with sacral fractures? PATIENTS AND METHODS: We performed a retrospective analysis of all patients treated from 2004-2014 with sacral fractures confirmed with a CT scan. A total of 531 patients (398 female, 133 male) were included in the study. Bone density was measured with CT scans in Hounsfield units in vertebral body L5. The assessment was performed by placing a single oval over the trabecular bone in the axial view. In the sagittal plane, the correct position in the middle of the vertebral body was checked. As in previously published studies, we defined bone of less than 100 HU as osteoporotic, 100-150 HU as osteopenic and above 150 HU as normal. RESULTS: In 71.6% of the patients, bone density was reduced. Seventy-five percent of patients aged 65 or more exhibited manifest osteoporosis. With each additional year of age, bone density decreased by 2.7 Hounsfield units (p˂0.001). Female patients were predominant in the patient group with osteoporotic bone (p˂0.001). CONCLUSIONS: There is significant prevalence of reduced bone density in the investigated patient group. The methodology used in this study is an uncomplicated procedure to further assess bone quality in patients with fractures of the pelvic ring. Fractures of the posterior pelvic ring in women over 65 years with low-energy trauma are most probably osteoporotic. LEVEL OF EVIDENCE: III.


Assuntos
Densidade Óssea , Vértebras Lombares/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Osso Esponjoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sacro/diagnóstico por imagem , Sacro/lesões , Fraturas da Coluna Vertebral/diagnóstico por imagem , Adulto Jovem
18.
J Orthop Trauma ; 21(5): 285-94, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17485992

RESUMO

OBJECTIVES/DESIGN: To assess the functional outcome after treatment of proximal humeral fractures with a new antegrade nail that provides angular and sliding stability. INTERVENTION/PATIENTS: Ninety-seven patients were treated during a 4-year period between April 2000 and March 2004. All patients were followed for 6 months, 51 patients (53%) for 12 months, and 31 patients (32%) for 24 months. This study focuses mainly on the patients with a follow up of 1 year. Their mean age was 68 years (range: 33 to 90); 22% were more than 80 years of age. MAIN OUTCOME MEASUREMENTS: All fractures were radiologically graded by the Neer and AO/ASIF classifications. Clinical assessment was performed at all follow-up visits using the Constant-Murley and Neer scores, and complications were recorded. RESULTS: There were 26.8% 2-part, 66% 3-part, and 7.2% 4-part fractures. The relative Constant-Murley score improved significantly (P < 0.001) from 72% at 6 months to 82% at 12 months after operation. No further improvement regarding functional outcome was observed after 24 months. Patients younger than 60 years of age had better results. No significant functional differences were found among 2-, 3- or 4-part fractures. Complications included backing out of the proximal screws (9.8%), secondary dislocation (1.9%), complete osteonecrosis (1.9%), and partial osteonecrosis (5.8%). CONCLUSION: Treatment with this nail provides sufficient fixation of the fragments to allow early mobilization. The good functional results in the majority of the patients indicate that this nail can be used, even in complex fractures and elderly patients.


Assuntos
Pinos Ortopédicos , Fixação Interna de Fraturas/métodos , Fraturas do Ombro/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroscopia , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
19.
Eur J Emerg Med ; 24(2): 120-125, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26287806

RESUMO

OBJECTIVES: Early diagnosis of traumatic brain injury and reliable prediction of outcome are essential for determining treatment strategies and allocating resources. This study re-evaluates the Eppendorf-Cologne Scale (ECS) and its predictive accuracy for outcome compared with the Glasgow Coma Scale (GCS). METHODS: A prospective cohort analysis of severely injured trauma patients registered in the Trauma Registry of the German Society for Trauma Surgery from 2012-2013 was carried out. Only directly admitted patients alive on admission with complete data on GCS, ECS and outcome in terms of survival to hospital discharge or death were included. The predictive accuracy in terms of the outcome of the ECS and the GCS was modelled using area under the receiver operating characteristic (AUROC) curve analysis. RESULTS: A total of 17 616 patients fulfilled the study inclusion criteria. The ECS outmatched the predictive accuracy of the GCS for outcome (AUROC, 0.853, 95% confidence interval, 0.831-0.854; and AUROC 0.836; 95% confidence interval, 0.825-0.848, respectively; P=0.062). An ECS score of 8 was associated with a 25-fold higher mortality compared with an ECS score of 0. Patients who had an ECS score of 8 had a 1.5-fold higher mortality compared with patients allocated a GCS score of 3. CONCLUSION: The ECS shows a higher accuracy for prediction of outcome compared with the GCS and enables further differentiation within the critical GCS 3 collective.


Assuntos
Lesões Encefálicas Traumáticas/diagnóstico , Índices de Gravidade do Trauma , Lesões Encefálicas Traumáticas/classificação , Feminino , Escala de Coma de Glasgow , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento
20.
J Orthop Trauma ; 31(7): e210-e216, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28240619

RESUMO

OBJECTIVES: Anatomical acetabular plates the anterior intrapelvic approach (AIP) were recently introduced to fix acetabular fractures through the intrapelvic approach. Therefore, we asked the following: (1) Does the preshaped 3-dimensional suprapectineal plate interfere with or even impair the fracture reduction quality? (2) How often does the AIP approach need to be extended by the first (lateral) window of the ilioinguinal approach? DESIGN: Observational case series. SETTING: Two Level 1 trauma centers. PATIENTS/PARTICIPANTS: Patients with unstable acetabular fractures in 2014. INTERVENTION: Fracture fixation with anatomical-preshaped, 3-dimensional suprapectineal plates through the AIP approach ± the first window of the ilioinguinal approach. OUTCOME MEASUREMENTS: Fracture reduction results were measured in computed tomography scans and graded according to the Matta quality of reduction. Intraoperative parameters and perioperative complications were recorded. Radiological results (according to Matta) and functional outcome (modified Merle d'Aubigné score) were evaluated at 1-year follow-up. RESULTS: Thirty patients (9 women + 21 men; mean age ± SE: 64 ± 8 years) were included. The intrapelvic approach was solely used in 19 cases, and in 11 cases, an additional extension with the first window of the ilioinguinal approach (preferential for 2-column fractures) was performed. The mean operating time was 202 ± 59 minutes; the fluoroscopic time was 66 ± 48 seconds. Fracture gaps and steps in preoperative versus postoperative computed tomography scans were 12.4 ± 9.8 versus 2.0 ± 1.5 and 6.0 ± 5.5 versus 1.3 ± 1.7 mm, respectively. At 13.4 ± 2.9 months follow-up, the Matta grading was excellent in 50%, good in 25%, fair in 11%, and poor in 14% of cases. The modified Merle d'Aubigné score was excellent in 17%, good in 37%, fair in 33%, and poor in 13% of cases. CONCLUSION: The AIP approach using approach-specific instruments and an anatomical-preshaped, 3-dimensional suprapectineal plate became the standard procedure in our departments. Radiological and functional early results justify joint preserving surgery in most cases. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Acetábulo/lesões , Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Idoso , Desenho de Equipamento , Feminino , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA