Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38587261

RESUMO

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Bioprótese/efeitos adversos , Insuficiência Cardíaca , Estimativa de Kaplan-Meier , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
2.
Eur Heart J ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38820201

RESUMO

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.

3.
J Cardiovasc Electrophysiol ; 34(11): 2225-2232, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37702135

RESUMO

INTRODUCTION: The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration ≥140 ms, and prosthesis oversizing ≥16%. To prospectively validate the previously described risk score. METHODS: We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis. RESULTS: A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001). CONCLUSIONS: The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
4.
J Card Fail ; 29(7): 1046-1055, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36958391

RESUMO

BACKGROUND: Left ventricular (LV) volume reshaping reduces myocardial wall stress and may induce reverse remodeling in patients with heart failure with reduced ejection fraction. The AccuCinch Transcatheter Left Ventricular Restoration system consists of a series of anchors connected by a cable implanted along the LV base that is cinched to the basal free wall radius. We evaluated the echocardiographic and clinical outcomes following transcatheter left ventricular restoration. METHODS AND RESULTS: We analyzed 51 heart failure patients with a left ventricular ejection fraction between 20% and 40%, with no more than 2+ mitral regurgitation treated with optimal medical therapy, who subsequently underwent transcatheter left ventricular restoration. Serial echocardiograms, Kansas City Cardiomyopathy Questionnaire scores, and 6-minute walk test distances were measured at baseline through 12 months. Primary analysis end point was change in end-diastolic volume at 12 months compared with baseline. Patients (n = 51) were predominantly male (86%) with a mean age of 56.3 ± 13.1 years. Fluoroscopy showed LV free wall radius decreased by a median of 9.2 mm amounting to a 29.6% decrease in the free wall arc length. At 12 months, the LV end-diastolic volume decreased by 33.6 ± 34.8 mL (P < .01), with comparable decreases in the LV end-systolic volume. These decreases were associated with significant improvements in the overall Kansas City Cardiomyopathy Questionnaire score (16.4 ± 18.7 points; P < .01) and 6-minute hall walk test distance (45.9 ± 83.9 m; P < .01). There were no periprocedural deaths; through the 1-year follow-up, 1 patient died (day 280) and 1 patient received a left ventricular assist device (day 13). CONCLUSIONS: In patients with heart failure with reduced ejection fraction without significant mitral regurgitation receiving optimal medical therapy, the AccuCinch System resulted in decreases of LV volume, as well as improved quality of life and exercise endurance. A randomized trial is ongoing (NCT04331769).


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
5.
Catheter Cardiovasc Interv ; 102(7): 1291-1300, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37890015

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is as an alternative treatment to surgical AVR, but the long-term outcomes of TAVR remain unclear. AIMS: This study aimed to analyze long-term outcomes following TAVR using meta-analysis. METHODS: A literature search was performed with MEDLINE, EMBASE, Cochrane Library, Web of Science, and Google Scholar through November 2022; studies reporting clinical outcomes of TAVR with follow-up periods of ≥8 years were included. The outcomes of interest were overall survival and/or freedom from structural valve deterioration (SVD). Surgical risk was assessed with the Society of Thoracic Surgeons (STS) predicted risk of mortality (PROM) score. A subgroup analysis was conducted for intermediate-/high-surgical risk patients only. RESULTS: Eleven studies including 5458 patients were identified and analyzed. The mean age was 82.0 ± 6.5 years, and mean STS PROM score ranged from 2.9 to 10.6%. Survival rate at 5 and 10 years was 47.7% ± 1.4% and 12.1 ± 2.0%. Five studies including 1509 patients were analyzed for SVD. Freedom from SVD at 5 and 8 years was 95.5 ± 0.7% and 85.1 ± 3.1%. Similar results for survival and SVD were noted in the subgroup analysis of intermediate-/high-risk patients. CONCLUSIONS: Following TAVR, approximately 88% of patients died within 10 years, whereas 85% were free from SVD at 8 years. These date suggest that baseline patient demographic have the greatest impact on survival, and SVD does not seem to have a prognostic impact in this population. Further investigations on longer-term outcomes of younger and lower-risk patients are warranted.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco
6.
Catheter Cardiovasc Interv ; 99(3): 924-931, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34626449

RESUMO

OBJECTIVES: We assessed the impact of conventional delivery system (DS) insertion technique on "Hat-marker" orientation/commissural alignment in patients who underwent transcatheter aortic valve replacement (TAVR) in the Evolut Low Risk Trial CT substudy versus a modified technique. BACKGROUND: Unlike surgical aortic valve replacement, where alignment of the surgical valve commissures with native commissures can be achieved virtually 100% of the time, commissural alignment during TAVR is not achieved consistently. This may subsequently impact the feasibility of both coronary access and reintervention after TAVR. METHODS: "Hat-marker" orientations during deployment were characterized as outer curve (OC), center front (CF), inner curve, and center back. Severe commissure-to-CA overlap was 0-20°. "Hat-marker" orientations and CA overlap were compared to 240 patients from a single center using the modified 3-o'clock flush port DS technique. RESULTS: In the CT substudy in which conventional DS insertion was performed (flush port at 12 o'clock); 154/249 had both analyzable CT and procedural fluoroscopy to validate "Hat-marker" to C-tab/commissural orientation. On post-TAVR CT, Evolut valve commissural orientation and coronary artery (CA) ostia were identified. Compared to conventional DS technique in the CT substudy, the modified technique had higher rates of "Hat-marker" at OC/CF orientation, improved commissural alignment and reduced severe CA overlap; (left main, 14.2 vs. 27.9%; right coronary artery, 11.7 vs. 27.3% both, 5.0 vs. 13.6%; 1 or both CA, 20.8 vs. 41.6%, all p < 0.01). CONCLUSIONS: The modified technique improved initial "Hat-marker" orientation during Evolut deployment and resulted in better commissural alignment and reduced CA overlap.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
J Interv Cardiol ; 2022: 9737245, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36101865

RESUMO

The use of bioprosthetic prostheses during surgical aortic valve replacements has increased dramatically over the last two decades, accounting for over 85% of surgical implantations. Given limited long-term durability, there has been an increase in aortic valve reoperations and reinterventions. With the advent of new technologies, multiple treatment strategies are available to treat bioprosthetic valve failure, including valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR). However, ViV TAVR has an increased risk of higher gradients and patient prosthesis mismatch (PPM) secondary to placing the new valve within the rigid frame of the prior valve, especially in patients with a small surgical bioprosthesis in situ. Bioprosthetic valve fracture allows for placement of a larger transcatheter valve, as well as a fully expanded transcatheter valve, decreasing postoperative gradients and the risk of PPM.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
8.
Curr Cardiol Rep ; 24(9): 1179-1187, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35767177

RESUMO

PURPOSE OF REVIEW: This review summarizes current data supporting a minimalist TAVR approach and identifies the need for additional study to optimize TAVR care. The authors discuss future directions of the TAVR landscape and how this necessitates evolution of minimalist care pathways. RECENT FINDINGS: Transcatheter aortic valve replacement (TAVR) has become a mainstay in the treatment of aortic stenosis since the initial procedure in 2002. Recently, attention has shifted to TAVR optimization and the minimalist approach with a focus on minimizing procedural sedation, protocolization of perioperative management, and prioritization on early discharge. This approach has been shown to be safe and reduce procedure time, length of stay, and overall cost for hospital systems. The minimalist care pathway avoids general anesthesia, shortens procedure time and length of stay, and reduces cost without changing mortality or readmission rates at 30 days. A variety of protocols have been proposed without a clear consensus on specific components or patient eligibility. There is a continued need for data regarding patient risk stratification, valve selection, and discharge strategy as TAVR becomes increasingly common.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Procedimentos Clínicos , Humanos , Tempo de Internação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
9.
J Card Surg ; 37(12): 4124-4132, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36168827

RESUMO

Transcatheter aortic valve replacement (TAVR) has transformed the treatment of aortic stenosis and pre-procedure planning relies heavily on advanced imaging. Multidetector computed tomography angiography, the "TAVR CT," facilitates essential planning steps of measuring the aortic root for valve sizing and feasibility and assessment of potential access vessels, making it the guideline gold standard in preprocedural TAVR work up. This Impact of Advanced Imaging Techniques on Cardiac Surgery article will examine the development of TAVR CT, illustrate the current impact and utility, and highlight potential areas of future growth. Clinicians who keep informed of these changes and can become proficient with TAVR CT analyses will offer patients the most optimal results and fuel future therapeutic growth.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Tomografia Computadorizada Multidetectores/métodos , Angiografia , Valor Preditivo dos Testes , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 97(5): 940-947, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33382519

RESUMO

OBJECTIVES: We sought to evaluate the safety, efficacy and feasibility of same-day discharge after uncomplicated, minimalist TAVR. BACKGROUND: At the start of the COVID-19 pandemic, we created a same-day discharge (SDD) pathway after conscious sedation, transfemoral (minimalist) TAVR to help minimize risk of viral transmission and conserve hospital resources. Studies support that next-day discharge (NDD) for carefully selected patients following minimalist TAVR is safe and feasible. There is a paucity of data regarding the safety of SDD after TAVR. METHODS: In-hospital and 30 day outcomes of consecutive patients meeting pre-specified criteria for SDD after minimalist TAVR at our institution between March and July of 2020 were reviewed. Outcomes were compared to a NDD cohort from July 2018 through July 2020 that would have met SDD criteria. Primary endpoints were mortality, delayed pacemaker placement, stroke and cardiovascular readmission at 30 days. RESULTS: Twenty nine patients were discharged via the SDD pathway after TAVR. 128 prior NDD patients were identified who met all criteria for SDD. The STS scores were similar between the two groups (SDD 2.6% ±1.5 vs. NDD 2.3% ± 1.2). There were no deaths at 30 days in either group. There was no significant difference in delayed pacemaker placement (SDD 0% vs. NDD 0.8%, p > .99) or cardiovascular readmission (SDD 0% vs. NDD 5.5%, p = .35) at 30 days. CONCLUSIONS: Same day discharge following uncomplicated, minimalist TAVR in selected patients appears to be safe, achieving similar 30 day outcomes as a cohort of next day discharge patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , COVID-19/epidemiologia , Pandemias , Alta do Paciente/tendências , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Comorbidade , Feminino , Seguimentos , Humanos , Tempo de Internação/tendências , Masculino , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
12.
Basic Res Cardiol ; 110(5): 503, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26150250

RESUMO

It is commonly thought that the optimal method for intracoronary administration of cells is to stop coronary flow during cell infusion, in order to prolong cell/vascular wall contact, enhance adhesion, and promote extravasation of cells into the interstitial space. However, occlusion of a coronary artery with a balloon involves serious risks of vascular damage and/or dissection, particularly in non-stented segments such as those commonly found in patients with heart failure. It remains unknown whether the use of the stop-flow technique results in improved donor cell retention. Acute myocardial infarction was produced in 14 pigs. One to two months later, pigs received 10 million indium-111 oxyquinoline (oxine)-labeled c-kit(pos) human cardiac stem cells (hCSCs) via intracoronary infusion with (n = 7) or without (n = 7) balloon inflation. Pigs received cyclosporine to prevent acute graft rejection. Animals were euthanized 24 h later and hearts harvested for radioactivity measurements. With the stop-flow technique, the retention of hCSCs at 24 h was 5.41 ± 0.80 % of the injected dose (n = 7), compared with 4.87 ± 0.62 % without coronary occlusion (n = 7), (P = 0.60). When cells are delivered intracoronarily in a clinically relevant porcine model of chronic ischemic cardiomyopathy, the use of the stop-flow technique does not result in greater myocardial cell retention at 24 h compared with non-occlusive infusion. These results have practical implications for the design of cell therapy trials. Our observations suggest that the increased risk of complications secondary to coronary manipulation and occlusion is not warranted.


Assuntos
Isquemia Miocárdica/cirurgia , Miócitos Cardíacos/transplante , Transplante de Células-Tronco/métodos , Animais , Separação Celular , Modelos Animais de Doenças , Feminino , Citometria de Fluxo , Humanos , Proteínas Proto-Oncogênicas c-kit , Sus scrofa
13.
Catheter Cardiovasc Interv ; 85(1): 118-29, 2015 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25204308

RESUMO

BACKGROUND: Data are limited regarding transcatheter aortic valve replacement (TAVR)-related thrombocytopenia (TP). We sought to thoroughly characterize the presence, clinical impact, and severity of TP associated with TAVR. METHODS AND RESULTS: Data were collected from 90 patients who underwent TAVR using the Edwards SAPIEN valve (59 TF, 29 TA, 2 Tao). Platelet counts were evaluated peri-procedurally and for 8 days following TAVR. Platelet levels were compared and patients were divided into a no TP (No-TP) group 1, acquired (new) TP (NTP) group 2, pre-existing (pre-TAVR) TP (PTP) group 3, and further stratified based on the severity of TP: mild (M) TP (100-149 × 10(3) cell/µL) and moderate-severe (MS) TP (<100 × 10(3) cell/µL). Pre-TAVR point prevalence and post-TAVR incidence of TP were 40% and 79%, respectively (P < 0.001); nadir platelet count in all groups occurred day 4 post-TAVR. Baseline predictors for developing MS TP in groups 2-3 included baseline TP, leaner body mass, smaller pre-procedural aortic valve area, higher peak aortic jet velocity, and worsening baseline renal function. Development of "major" TP (nadir platelet count <100 × 103 cell/µL, ≥50% decrease) predicted a higher risk of major vascular complications (OR 2.78 [95% CI, 1.58-3.82]) and major bleeding (OR 3.18 [95% CI, 1.33-5.42]) in group 3. CONCLUSION: TAVR-related TP is predictable and classification by PTP and TP severity prior to TAVR allows for better risk stratification in predicting in-hospital clinical outcomes. Major TP in the presence of worsening TP is predictable and is associated with worse clinical outcomes. © 2014 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Trombocitopenia/etiologia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Distribuição de Qui-Quadrado , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Kentucky , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Contagem de Plaquetas , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Trombocitopenia/sangue , Trombocitopenia/diagnóstico , Fatores de Tempo , Resultado do Tratamento
14.
Ann Cardiothorac Surg ; 13(3): 236-243, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38841088

RESUMO

For decades, surgeons have recognized the risk of prosthesis-patient mismatch (PPM) when treating aortic stenosis (AS) with surgical aortic valve replacement (SAVR). The concept of PPM-or placing a valve that is too small for the cardiac output requirements of the patient-has been associated with worse patient outcomes, including increased risk of death. Transcatheter aortic valve replacement (TAVR) has become the standard treatment for most patients with severe symptomatic AS and is associated with improved hemodynamics and lower risks of PPM. Larger surgical valves, stentless, and sutureless technology, and surgical aortic annulus enlargement (AAE) have been employed to avoid severe PPM. However, especially in the small aortic annulus (SAA), TAVR may provide a benefit. Understanding who is at risk for PPM requires preplanning, and cardiac-gated computed tomography (CT) imaging is the standard of care when considering TAVR. It should be standard for all patients with AS. Once SAA is identified, the risk of PPM can be calculated, and an informed decision made on whether to proceed with SAVR or TAVR. In the current TAVR era, younger patients are treated with TAVR driven by patient preference, but with little long-term data to support the practice. Selecting the best valve for the patient is a multifactorial decision often nuanced by anatomical considerations, hemodynamic and durability expectations, and decisions regarding lifetime management that may include placing a second valve. Although PPM may be only one of the factors to consider, the association with elevated mean gradients and worse outcomes certainly makes TAVR a good solution for many patients.

15.
J Am Heart Assoc ; 13(9): e033846, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38639328

RESUMO

BACKGROUND: Next-day discharge (NDD) outcomes following uncomplicated self-expanding transcatheter aortic valve replacement have not been studied. Here, we compare readmission rates and clinical outcomes in NDD versus non-NDD transcatheter aortic valve replacement with Evolut. METHODS AND RESULTS: Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry patients (n=29 597) undergoing elective transcatheter aortic valve replacement with self-expanding supra-annular valves (Evolut R, PRO, and PRO+) from July 2019 to June 2021 were stratified by postprocedure length of stay: ≤1 day (NDD) versus >1 day (non-NDD). Propensity score matching was used to compare risk adjusted 30-day readmission rates and 1-year outcomes in NDD versus non-NDD, and multivariable regression to determine predictors of NDD and readmission. Between the first and last calendar quarter, the rate of NDD increased from 45.4% to 62.1% and median length of stay decreased from 2 days to 1. Propensity score matching produced relatively well-matched NDD and non-NDD cohorts (n=10 549 each). After matching, NDD was associated with lower 30-day readmission rates (6.3% versus 8.4%; P<0.001) and 1-year adverse outcomes (death, 7.0% versus 9.3%; life threatening/major bleeding, 1.6% versus 3.4%; new permanent pacemaker implantation/implantable cardioverter-defibrillator, 3.6 versus 11.0%; [all P<0.001]). Predictors of NDD included non-Hispanic ethnicity, preexisting permanent pacemaker implantation/implantable cardioverter-defibrillator, and previous surgical aortic valve replacement. CONCLUSIONS: Most patients undergoing uncomplicated self-expanding Evolut transcatheter aortic valve replacement are discharged the next day. This study found that NDD can be predicted from baseline patient characteristics and was associated with favorable 30-day and 1-year outcomes, including low rates of permanent pacemaker implantation and readmission.


Assuntos
Estenose da Valva Aórtica , Alta do Paciente , Readmissão do Paciente , Pontuação de Propensão , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/tendências , Readmissão do Paciente/estatística & dados numéricos , Readmissão do Paciente/tendências , Masculino , Feminino , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Idoso , Alta do Paciente/tendências , Sistema de Registros , Tempo de Internação/estatística & dados numéricos , Tempo de Internação/tendências , Fatores de Tempo , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento , Estados Unidos/epidemiologia , Fatores de Risco , Valva Aórtica/cirurgia , Estudos Retrospectivos , Desenho de Prótese , Medição de Risco
16.
J Am Heart Assoc ; 13(9): e033872, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38700000

RESUMO

BACKGROUND: The mortality risk attributable to moderate aortic stenosis (AS) remains incompletely characterized and has historically been underestimated. We aim to evaluate the association between moderate AS and all-cause death, comparing it with no/mild AS (in a general referral population and in patients with heart failure with reduced ejection fraction). METHODS AND RESULTS: A systematic review and pooled meta-analysis of Kaplan-Meier-derived reconstructed time-to-event data of studies published by June 2023 was conducted to evaluate survival outcomes among patients with moderate AS in comparison with individuals with no/mild AS. Ten studies were included, encompassing a total of 409 680 patients (11 527 with moderate AS and 398 153 with no/mild AS). In the overall population, the 15-year overall survival rate was 23.3% (95% CI, 19.1%-28.3%) in patients with moderate AS and 58.9% (95% CI, 58.1%-59.7%) in patients with no/mild aortic stenosis (hazard ratio [HR], 2.55 [95% CI, 2.46-2.64]; P<0.001). In patients with heart failure with reduced ejection fraction, the 10-year overall survival rate was 15.5% (95% CI, 10.0%-24.0%) in patients with moderate AS and 37.3% (95% CI, 36.2%-38.5%) in patients with no/mild AS (HR, 1.83 [95% CI, 1.69-2.0]; P<0.001). In both populations (overall and heart failure with reduced ejection fraction), these differences correspond to significant lifetime loss associated with moderate AS during follow-up (4.4 years, P<0.001; and 1.9 years, P<0.001, respectively). A consistent pattern of elevated mortality rate associated with moderate AS in sensitivity analyses of matched studies was observed. CONCLUSIONS: Moderate AS was associated with higher risk of death and lifetime loss compared with patients with no/mild AS.


Assuntos
Estenose da Valva Aórtica , Humanos , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Medição de Risco/métodos , Fatores de Risco , Volume Sistólico/fisiologia , Causas de Morte , Fatores de Tempo , Feminino , Idoso , Masculino
17.
Artigo em Inglês | MEDLINE | ID: mdl-38871537

RESUMO

BACKGROUND: Permanent pacemaker implantation (PPI) rates following transcatheter aortic valve replacement (TAVR) remain a concern. We assessed the PPI rates over time in patients implanted with an Evolut supra-annular, self-expanding transcatheter valve from the US STS/ACC TVT Registry. METHODS: Patients who underwent TAVR with an Evolut R, Evolut PRO or Evolut PRO+ valve between July 2018 (Q3) and June 2021 (Q2) were included. PPI rates were reported by calendar quarter. In-hospital PPI rates were reported as proportions and 30-day rates as Kaplan-Meier estimates. A Cox regression model was used to determine potential predictors of a new PPI within 30 days of the TAVR procedure. RESULTS: From July 2018 to June 2021, 54,014 TAVR procedures were performed using Evolut valves. Mean age was 79.3 ± 8.8 years and 49.2 % were male. The 30-day PPI rate was 16.6 % in 2018 (Q3) and 10.8 % in 2021 (Q2, 34.9 % decrease, p < 0.001 for trend across all quarters). The in-hospital PPI rate decreased by 40.1 %; from 14.7 % in 2018 (Q3) to 8.8 % in 2021 (Q2) (p < 0.001 for trend across all quarters). Significant predictors of a new PPI within 30 days included a baseline conduction defect, history of atrial fibrillation, home oxygen, and diabetes mellitus. CONCLUSION: From 2018 to 2021, TAVR with an Evolut transcatheter heart valve in over 50,000 patients showed a significant decreasing trend in the rates of in-hospital and 30-day PPI, representing the lowest rate of PPI in any large real-world registry of Evolut. During the same evaluated period, high device success and shorter length of stay was also observed.

18.
Am J Cardiol ; 220: 84-91, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38604492

RESUMO

Development of functional tricuspid regurgitation (TR) because of chronic mitral disease and subsequent heart failure is common. However, the effect of TR on clinical outcomes after transcatheter mitral valve replacement (TMVR) remains unclear. We aimed to evaluate the impact of baseline TR on outcomes after TMVR. This was a single-center, retrospective analysis of patients who received valve-in-valve or valve-in-ring TMVR between 2012 and 2022. Patients were categorized into none/mild TR and moderate/severe TR based on baseline echocardiography. The primary outcome was 3 years all-cause death and the secondary outcomes were in-hospital events. Of the 135 patients who underwent TMVR, 64 (47%) exhibited none/mild TR at baseline, whereas 71 (53%) demonstrated moderate/severe TR. There were no significant differences in in-hospital events between the groups. At 3 years, the moderate/severe TR group exhibited a significantly increased risk of all-cause death (adjusted hazard ratio 3.37, 95% confidence interval 1.35 to 8.41, p = 0.009). When patients with baseline moderate/severe TR were stratified by echocardiography at 30 days into improved (36%) and nonimproved (64%) TR groups, although limited by small sample size, there was no significant difference in 3-year all-cause mortality (p = 0.48). In conclusion, this study investigating the impact of baseline TR on clinical outcomes revealed that moderate/severe TR is prevalent in those who underwent TMVR and is an independent predictor of 3-year all-cause mortality. Earlier mitral valve intervention before the development of significant TR may play a pivotal role in improving outcomes after TMVR.


Assuntos
Ecocardiografia , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Humanos , Masculino , Insuficiência da Valva Tricúspide/cirurgia , Feminino , Estudos Retrospectivos , Idoso , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco/métodos , Índice de Gravidade de Doença , Resultado do Tratamento , Causas de Morte/tendências , Complicações Pós-Operatórias/epidemiologia , Idoso de 80 Anos ou mais , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem
19.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38573257

RESUMO

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Incidência , Retratamento
20.
J Am Coll Cardiol ; 83(14): 1257-1272, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38471643

RESUMO

BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a source of morbidity in hypertrophic cardiomyopathy (HCM) and a life-threatening complication of transcatheter mitral valve replacement (TMVR) and transcatheter aortic valve replacement (TAVR). Available surgical and transcatheter approaches are limited by high surgical risk, unsuitable septal perforators, and heart block requiring permanent pacemakers. OBJECTIVES: The authors report the initial experience of a novel transcatheter electrosurgical procedure developed to mimic surgical myotomy. METHODS: We used septal scoring along midline endocardium (SESAME) to treat patients, on a compassionate basis, with symptomatic LVOT obstruction or to create space to facilitate TMVR or TAVR. RESULTS: In this single-center retrospective study between 2021 and 2023, 76 patients underwent SESAME. In total, 11 (14%) had classic HCM, and the remainder underwent SESAME to facilitate TMVR or TAVR. All had technically successful SESAME myocardial laceration. Measures to predict post-TMVR LVOT significantly improved (neo-LVOT 42 mm2 [Q1-Q3: 7-117 mm2] to 170 mm2 [Q1-Q3: 95-265 mm2]; P < 0.001; skirt-neo-LVOT 169 mm2 [Q1-Q3: 153-193 mm2] to 214 mm2 [Q1-Q3: 180-262 mm2]; P < 0.001). Among patients with HCM, SESAME significantly decreased invasive LVOT gradients (resting: 54 mm Hg [Q1-Q3: 40-70 mm Hg] to 29 mm Hg [Q1-Q3: 12-36 mm Hg]; P = 0.023; provoked 146 mm Hg [Q1-Q3: 100-180 mm Hg] to 85 mm Hg [Q1-Q3: 40-120 mm Hg]; P = 0.076). A total of 74 (97.4%) survived the procedure. Five experienced 3 of 76 (3.9%) iatrogenic ventricular septal defects that did not require repair and 3 of 76 (3.9%) ventricular free wall perforations. Neither occurred in patients treated for HCM. Permanent pacemakers were required in 4 of 76 (5.3%), including 2 after concomitant TAVR. Lacerations were stable and did not propagate after SESAME (remaining septum: 5.9 ± 3.3 mm to 6.1 ± 3.2 mm; P = 0.8). CONCLUSIONS: With further experience, SESAME may benefit patients requiring septal reduction therapy for obstructive hypertrophic cardiomyopathy as well as those with LVOT obstruction after heart valve replacement, and/or can help facilitate transcatheter valve implantation.


Assuntos
Cardiomiopatia Hipertrófica , Implante de Prótese de Valva Cardíaca , Miotomia , Obstrução da Via de Saída Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo , Humanos , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Cateterismo Cardíaco/métodos , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Resultado do Tratamento , Cardiomiopatia Hipertrófica/complicações , Miotomia/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA