Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 24(8): 2012-22, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24838733

RESUMO

OBJECTIVES: Breastfeeding is a well-recognised investment in the health of the mother-infant dyad. Nevertheless, many professionals still advise breastfeeding mothers to temporarily discontinue breastfeeding after contrast media imaging. Therefore, we performed this review to provide health professionals with basic knowledge and skills for appropriate use of contrast media. METHODS: A joint working group of the Italian Society of Radiology (SIRM), Italian Society of Paediatrics (SIP), Italian Society of Neonatology (SIN) and Task Force on Breastfeeding, Ministry of Health, Italy prepared a review of the relevant medical literature on the safety profile of contrast media for the nursing infant/child. RESULTS: Breastfeeding is safe for the nursing infant of any post-conceptional age after administration of the majority of radiological contrast media to the mother; only gadolinium-based agents considered at high risk of nephrogenic systemic fibrosis (gadopentetate dimeglumine, gadodiamide, gadoversetamide) should be avoided in the breastfeeding woman as a precaution; there is no need to temporarily discontinue breastfeeding or to express and discard breast milk following the administration of contrast media assessed as compatible with breastfeeding. CONCLUSIONS: Breastfeeding women should receive unambiguous professional advice and clear encouragement to continue breastfeeding after imaging with the compatible contrast media. KEY POINTS: • Breastfeeding is a well-known investment in the health of the mother-infant dyad. • Breastfeeding is safe after administration of contrast media to the mother. • There is no need to temporarily discontinue breastfeeding following administration of contrast media.


Assuntos
Aleitamento Materno , Meios de Contraste , Neonatologia/métodos , Guias de Prática Clínica como Assunto , Radiologia , Sociedades Médicas , Adulto , Feminino , Humanos , Lactente , Itália
2.
Pediatr Emerg Care ; 30(4): 268, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24694884

RESUMO

A case of a pneumomediastinum mimicking a pericarditis in a boy with an occult perforation due to ulcerative colitis is reported. Pneumomediastinum is a rare complication of severe attacks of ulcerative colitis, with or without the previous development of a toxic megacolon, that should be considered in the differential diagnosis.


Assuntos
Colite Ulcerativa/complicações , Enfisema Mediastínico/etiologia , Pericardite/etiologia , Adolescente , Diagnóstico Diferencial , Humanos , Perfuração Intestinal/etiologia , Masculino , Enfisema Mediastínico/diagnóstico , Pericardite/diagnóstico , Radiografia Torácica
3.
Radiology ; 251(1): 280-6, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19190252

RESUMO

PURPOSE: To measure epidermal thickness by using skin ultrasonography (US) in a series of healthy control subjects and obligate carriers for the worldwide most frequent form of congenital hearing loss owing to the mutated alleles of the connexin 26 gene (GJB2). MATERIALS AND METHODS: The patent for the protocol, coupled with a new sonographic probe specifically designed to analyze epidermal thickness and a dedicated algorithm to classify individuals in groups, is pending. Institutional ethics committee approval and patient consent were obtained. After a preliminary study in 23 subjects aimed to define the best body site and instrument and protocol for US, a total of 303 individuals (237 healthy subjects, 51 carriers, and 15 homozygotes) were tested at midline forehead by using a linear large-band probe with a frequency ranging from 6 to 15 MHz to determine epidermal thickness. Variance and linear regression analyses were performed. Regression coefficients were then used to obtain measurements of thickness corrected for age and sex. RESULTS: GJB2 obligate carriers had a significant increase in epidermal thickness compared with control subjects. GJB2 status explains about 50.0% of this variability, whereas an additional 25.0% is explained by sex and age. Results led to the development of a possible screening protocol with a 98.0% sensitivity and 92.8% specificity in subjects aged 2080 years, with a likelihood ratio of a positive test of 14:1. Even better results (100% sensitivity and 98.9% specificity) were obtained in an analysis of people of only reproductive age. CONCLUSION: Epidermal thickening in the white population owing to GJB2 carrier status can be detected by using US. This measurement could provide a simple, noninvasive, rapid, and sensitive test for carrier screening.


Assuntos
Conexinas/genética , Epiderme/diagnóstico por imagem , Testes Genéticos/métodos , Perda Auditiva/epidemiologia , Perda Auditiva/genética , Medição de Risco/métodos , Ultrassonografia/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Conexina 26 , Feminino , Predisposição Genética para Doença/genética , Heterozigoto , Humanos , Incidência , Itália/epidemiologia , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Adulto Jovem
4.
Pediatr Pulmonol ; 41(7): 694-8, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16703583

RESUMO

Tuberculosis (TB) has been described in association with different malignancies including Hodgkin's disease. However, the association with primary pulmonary Hodgkin's disease (PPHD) is hardly reported in literature and in teenage is quite exceptional. We report a case of an 11 years old boy in whom the diagnosis of tuberculosis preceded and delayed the diagnosis of PPHL.


Assuntos
Doença de Hodgkin/complicações , Neoplasias Pulmonares/complicações , Tuberculose Pulmonar/complicações , Criança , Doença de Hodgkin/diagnóstico , Humanos , Neoplasias Pulmonares/diagnóstico , Masculino , Tuberculose Pulmonar/diagnóstico
5.
PLoS One ; 11(10): e0164539, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27749905

RESUMO

BACKGROUND: The use of point-of-care ultrasonography (POC US) in paediatrics is increasing. This study investigated the diagnostic accuracy of POC US in children accessing the emergency department (ED) when performed by paediatricians under the remote guidance of radiologists (TELE POC). METHODS: Children aged 0 to 18 years accessing the ED of a third level research hospital with eight possible clinical scenarios and without emergency/severity signs at the triage underwent three subsequent US tests: by a paediatrician guided remotely by a radiologist (TELE POC); by the same radiologist (UNBLIND RAD); by an independent blinded radiologist (BLIND RAD). Tele-radiology was implemented using low cost "commercial off-the-shelf" (COTS) equipment and open-source software. Data were prospectively collected on predefined templates. RESULTS: Fifty-two children were enrolled, for a total of 170 ultrasound findings. Sensitivity, specificity, positive and negative predictive values of TELE POC were: 93.8, 99.7, 96.8, 99.4 when compared to UNBLIND RAD and 88.2, 99.7, 96.8, 98.7 when compared to BLIND RAD. The inter-observers agreement between the paediatricians and either the unblind or blind radiologist was excellent (k = 0.93). The mean duration of TELE POC was 6.3 minutes (95% CI 4.1 to 8.5). Technical difficulties occurred in two (3.8%) cases. Quality of the transmission was rated as fair, good, very good and excellent in 7.7%, 15.4%, 42.3% and 34.6% of cases respectively, while in no case was it rated as poor. CONCLUSIONS: POC US performed by paediatricians in ED guided via tele-radiology by an expert radiologist (TELE POC) produced reliable and timely diagnoses. Findings of this study, especially for the rarer conditions under evaluation, need further confirmation. Future research should investigate the overall benefits and the cost savings of using tele-ultrasound to perform US "at children's bedsides", under remote guidance of expert radiologists.


Assuntos
Erros de Diagnóstico/estatística & dados numéricos , Sistemas Automatizados de Assistência Junto ao Leito , Prática Profissional/estatística & dados numéricos , Consulta Remota/métodos , Ultrassonografia , Abdome/diagnóstico por imagem , Adolescente , Criança , Pré-Escolar , Sistemas Computacionais , Serviço Hospitalar de Emergência/economia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Consulta Remota/instrumentação , Software
6.
Arch Dis Child ; 99(12): 1087-90, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24951462

RESUMO

OBJECTIVE: Hand fractures are common in childhood, and radiography is the standard diagnostic procedure. US has been used to evaluate bone injuries, mainly in adults for long-bone trauma; there are only a few studies about hand fractures in children. The purpose of this study was to evaluate and confirm the safety and applicability of the US diagnostic procedure in comparison to X-ray diagnosis. STUDY DESIGN: This cross-sectional study involved a convenience sample of young patients (between 2 and 17 years old) who were taken to the emergency department due to hand trauma. After clinical assessment, patients with a suspected hand fracture first underwent X-ray, and subsequently US examination by two different operators; a radiologist experienced in US and a trained emergency physician in "double-blind" fashion. US and radiographic findings were then compared, and sensitivity as well as specificity was calculated. RESULTS: A total of 204 patients were enrolled in the study. Seventy-nine fractures of phalanges or metacarpals were detected by standard radiography. When US imaging was performed by an expert radiologist, 72 fractures were detected with sensitivity and a specificity of 91.1% and 97.6%, respectively. Sensitivity and specificity were found to be (respectively) 91.5% and 96.8% when US was performed by the ED physicians. CONCLUSIONS: US imaging showed excellent sensitivity and specificity results in the diagnosis of hand fractures in children. The study also showed a great agreement between the results of the US carried out by the senior radiologist and those carried out by the paediatric emergency physician, suggesting that US can be performed by an ED physician, allowing a rapid and accurate evaluation in ED and could become the first diagnostic approach whenever a hand fracture is suspected.


Assuntos
Fraturas Ósseas/diagnóstico por imagem , Ossos da Mão/lesões , Adolescente , Criança , Pré-Escolar , Estudos Transversais , Método Duplo-Cego , Serviço Hospitalar de Emergência , Feminino , Ossos da Mão/diagnóstico por imagem , Humanos , Itália , Masculino , Radiografia , Sensibilidade e Especificidade , Ultrassonografia
7.
Fertil Steril ; 87(6): 1458-67, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17368451

RESUMO

OBJECTIVE: To compare the use of a balloon catheter device with the use of a cervical vacuum cup device in performing hysterosalpingography (HSG). DESIGN: Prospective, randomized, single-blinded study. SETTING: Tertiary infertility center. PATIENT(S): Two hundred twenty-nine infertile women undergoing HSG. INTERVENTION(S): Subjects were randomized to undergo HSG using a cervical vacuum cup (n = 115) or a balloon catheter (n = 114). Randomization was performed according to Consolidated Standard of Reporting Trials (CONSORT) guidelines. MAIN OUTCOME MEASURE(S): The degree of pain experienced during and after the HSG, evaluated using a 100-mm visual analogue scale. The length of the procedure, the fluoroscopic time, the volume of contrast used, the difficulty of performing HSG, and the percentage of complications were also evaluated. RESULT(S): Women in the cervical-cup group experienced more pain than those in the balloon catheter group during the contrast injection (median visual analogue scale pain scores, 13.0 vs. 6.5). The placement of the balloon catheter in comparison with the cervical cup was slightly easier to perform, although it required a somewhat longer time. The HSG using the cervical cup required less fluoroscopic time (median, 0.6 vs. 0.8 min). CONCLUSION(S): The balloon catheter appears to be better tolerated than the cervical cup, but the difference is minimal. The use of the cervical cup allows shortening of the patient radiation exposure.


Assuntos
Colo do Útero/diagnóstico por imagem , Histerossalpingografia/métodos , Infertilidade Feminina/diagnóstico por imagem , Cateterismo/métodos , Colo do Útero/patologia , Constrição Patológica , Feminino , Humanos , Histerossalpingografia/efeitos adversos , Estudos Longitudinais , Medição da Dor , Método Simples-Cego , Vácuo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA