Sensors (Basel) ; 23(5)2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36904965

RESUMO

Bladder monitoring, including urinary incontinence management and bladder urinary volume monitoring, is a vital part of urological care. Urinary incontinence is a common medical condition affecting the quality of life of more than 420 million people worldwide, and bladder urinary volume is an important indicator to evaluate the function and health of the bladder. Previous studies on non-invasive techniques for urinary incontinence management technology, bladder activity and bladder urine volume monitoring have been conducted. This scoping review outlines the prevalence of bladder monitoring with a focus on recent developments in smart incontinence care wearable devices and the latest technologies for non-invasive bladder urine volume monitoring using ultrasound, optical and electrical bioimpedance techniques. The results found are promising and their application will improve the well-being of the population suffering from neurogenic dysfunction of the bladder and the management of urinary incontinence. The latest research advances in bladder urinary volume monitoring and urinary incontinence management have significantly improved existing market products and solutions and will enable the development of more effective future solutions.


Assuntos
Líquidos Corporais , Incontinência Urinária , Dispositivos Eletrônicos Vestíveis , Humanos , Bexiga Urinária , Qualidade de Vida
2.
Sensors (Basel) ; 23(22)2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-38005593

RESUMO

The development of smart wearable solutions for monitoring daily life health status is increasingly popular, with chest straps and wristbands being predominant. This study introduces a novel sensorized T-shirt design with textile electrodes connected via a knitting technique to a Movesense device. We aimed to investigate the impact of stationary and movement actions on electrocardiography (ECG) and heart rate (HR) measurements using our sensorized T-shirt. Various activities of daily living (ADLs), including sitting, standing, walking, and mopping, were evaluated by comparing our T-shirt with a commercial chest strap. Our findings demonstrate measurement equivalence across ADLs, regardless of the sensing approach. By comparing ECG and HR measurements, we gained valuable insights into the influence of physical activity on sensorized T-shirt development for monitoring. Notably, the ECG signals exhibited remarkable similarity between our sensorized T-shirt and the chest strap, with closely aligned HR distributions during both stationary and movement actions. The average mean absolute percentage error was below 3%, affirming the agreement between the two solutions. These findings underscore the robustness and accuracy of our sensorized T-shirt in monitoring ECG and HR during diverse ADLs, emphasizing the significance of considering physical activity in cardiovascular monitoring research and the development of personal health applications.


Assuntos
Atividades Cotidianas , Têxteis , Humanos , Frequência Cardíaca/fisiologia , Eletrocardiografia , Monitorização Fisiológica/métodos
3.
Front Bioeng Biotechnol ; 11: 1199604, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37378045

RESUMO

Photoplethysmography is a non-invasive technique used for measuring several vital signs and for the identification of individuals with an increased disease risk. Its principle of work is based on detecting changes in blood volume in the microvasculature of the skin through the absorption of light. The extraction of relevant features from the photoplethysmography signal for estimating certain physiological parameters is a challenging task, where various feature extraction methods have been proposed in the literature. In this work, we present PPGFeat, a novel MATLAB toolbox supporting the analysis of raw photoplethysmography waveform data. PPGFeat allows for the application of various preprocessing techniques, such as filtering, smoothing, and removal of baseline drift; the calculation of photoplethysmography derivatives; and the implementation of algorithms for detecting and highlighting photoplethysmography fiducial points. PPGFeat includes a graphical user interface allowing users to perform various operations on photoplethysmography signals and to identify, and if required also adjust, the fiducial points. Evaluating the PPGFeat's performance in identifying the fiducial points present in the publicly available PPG-BP dataset, resulted in an overall accuracy of 99% and 3038/3066 fiducial points were correctly identified. PPGFeat significantly reduces the risk of errors in identifying inaccurate fiducial points. Thereby, it is providing a valuable new resource for researchers for the analysis of photoplethysmography signals.

4.
Biomed Tech (Berl) ; 66(5): 515-527, 2021 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-34162027

RESUMO

In impedance cardiography (ICG), the detection of dZ/dt signal (ICG) characteristic points, especially the X point, is a crucial step for the calculation of hemodynamic parameters such as stroke volume (SV) and cardiac output (CO). Unfortunately, for beat-to-beat calculations, the accuracy of the detection is affected by the variability of the ICG complex subtypes. Thus, in this work, automated classification of ICG complexes is proposed to support the detection of ICG characteristic points and the extraction of hemodynamic parameters according to several existing subtypes. A novel pattern recognition artificial neural network (PRANN) approach was implemented, and a divide-and-conquer strategy was used to identify the five different waveforms of the ICG complex waveform with output nodes no greater than 3. The PRANN was trained, tested and validated using a dataset from four volunteers from a measurement of eight electrodes. Once the training was satisfactory, the deployed network was validated on two other datasets that were completely different from the training dataset. As an additional performance validation of the PRANN, each dataset included four volunteers for a total of eight volunteers. The results show an average accuracy of 96% in classifying ICG complex subtypes with only a decrease in the accuracy to 83 and 80% on the validation datasets. This work indicates that the PRANN is a promising method for automated classification of ICG subtypes, facilitating the investigation of the extraction of hemodynamic parameters from beat-to-beat dZ/dt complexes.


Assuntos
Cardiografia de Impedância , Redes Neurais de Computação , Débito Cardíaco , Hemodinâmica , Humanos , Volume Sistólico
5.
IEEE J Biomed Health Inform ; 22(6): 1883-1894, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29990025

RESUMO

Impedance Cardiography (ICG) is a non-invasive method for monitoring cardiac dynamics using Electrical Bioimpedance (EBI) measurements. Since its appearance more than 40 years ago, ICG has been used for assessing hemodynamic parameters. This paper present a measurement system based on two System on Chip (SoC) solutions and Raspberry PI, implementing both a full 3-lead ECG recorder and an impedance cardiographer, for educational and research development purposes. Raspberry PI is a platform supporting Do-It-Yourself project and education applications across the world. The development is part of Biosignal PI, an open hardware platform focusing in quick prototyping of physiological measurement instrumentation. The SoC used for sensing cardiac biopotential is the ADAS1000, and for the EBI measurement is the AD5933. The recording were wirelessly transmitted through Bluetooth to a PC, where the waveforms were displayed, and hemodynamic parameters such as heart rate, stroke volume, ejection time and cardiac output were extracted from the ICG and ECG recordings. These results show how Raspberry PI can be used for quick prototyping using relatively widely available and affordable components, for supporting developers in research and engineering education. The design and development documents, will be available on www.BiosignalPI.com, for open access under a Non Commercial-Share A like 4.0 International License.


Assuntos
Cardiografia de Impedância/instrumentação , Eletrocardiografia/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Adulto , Tecnologia Biomédica , Desenho de Equipamento , Feminino , Humanos , Masculino , Adulto Jovem
6.
J Electr Bioimpedance ; 9(1): 72-82, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33584923

RESUMO

The quality of an impedance cardiography (ICG) signal critically impacts the calculation of hemodynamic parameters. These calculations depend solely on the identification of ICG characteristic points on the ABEXYOZ complex. Unfortunately, contrary to the relatively constant morphology of the PQRST complex in electrocardiography, the waveform morphology of ICG data is far from stationary, which causes difficulties in the accuracy of the automated detection of characteristic ICG points. This study evaluated ICG recordings obtained from 10 volunteers. The results indicate that there are several different waveforms for the ABEXYOZ complex; there are up to five clearly distinct waveforms for the ABEXYOZ complex in addition to those that are typically reported. The differences between waveform types increased the difficulty of detecting ICG points. To accurately detect all ICG points, the ABEXYOZ complex should be analyzed according to the corresponding waveform type.

SELEÇÃO DE REFERÊNCIAS