Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Strength Cond Res ; 38(1): 30-37, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37815253

RESUMO

ABSTRACT: Merrigan, JJ, Strang, A, Eckerle, J, Mackowski, N, Hierholzer, K, Ray, NT, Smith, R, Hagen, JA, and Briggs, RA. Countermovement jump force-time curve analyses: reliability and comparability across force plate systems. J Strength Cond Res 38(1): 30-37, 2024-Considering the growing prevalence of commercial force plates providing automated force-time analyses, understanding levels of agreement across force plate systems is warranted. Countermovement jump (CMJ) metrics across Vald ForceDecks (FD), Hawkin Dynamics (HD), and Sparta Science (SS) force plate systems were compared. Twenty-two subjects completed CMJ testing (∼128 comparisons) on each force plate system separately with rest between jumps. Baseline testing occurred 3 times and demonstrated poor test-retest reliability for modified reactive strength index (mRSI) and rate of force development (RFD). ForceDecks and HD comparisons yielded acceptable agreement for concentric/propulsive relative force and net impulse, jump height, eccentric/braking RFD, and mRSI, but systematic and proportionate bias existed for RFD. Sparta Science jump height and reactive strength index (RSI) demonstrated systematic overestimations compared with HD and FD, but jump height had acceptable agreement according to concordance correlation coefficients (CCC = 0.92-0.95). Agreement between SS load (eccentric RFD) and HD braking RFD was acceptable (CCC = 0.91), whereas agreement between SS load and FD deceleration RFD was considered acceptable (CCC = 0.81-0.87) but demonstrated systematic and proportionate bias. ForceDecks (CCC = 0.89) and HD (CCC = 0.85) average relative concentric/propulsive force yielded acceptable agreement with SS explode (average relative concentric force), but SS explode demonstrated systematically lower values than FD and HD. Sparta Science drive (concentric impulse) yielded acceptable agreement with HD relative propulsive impulse (CCC = 0.85), but not FD concentric impulse. Human performance practitioners need to be aware of inconsistencies among testing procedures and analyses across force plate systems, such as differences in metric definitions and units of measurement, before making comparisons across systems.


Assuntos
Força Muscular , Humanos , Reprodutibilidade dos Testes
2.
Lasers Med Sci ; 38(1): 111, 2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37099210

RESUMO

This study aims to examine the effects of acute whole-body photobiomodulation (wbPBM), applied pre-exercise, on bouts of anaerobic cycling (Wingate) performances. Forty-eight healthy, active males and females participated in this single-blind, randomized, crossover study. Participants visited the laboratory three times to complete repeat (4 ×) Wingate testing, with one week between each visit. All participants completed baseline testing during their first visit and randomly received either the wbPBM or placebo condition before testing on the second visit, followed by the opposite condition on the third visit. There were no significant condition × time interactions for any variable (peak power, average power, power decrement, lactate, heart rate, ratings of perceived exertion, heart rate variability (HRV), root-mean square of differences between R-R intervals (rMSSD), power in the high-frequency range (HF) average, power in the low-frequency range (LF) average, total power, LF/HF, or power in the very-low-frequency range average). A main condition effect was only noted for heart rate, where peak heart rate was significantly higher for wbPBM (145, 141-148 bpm) than placebo (143, 139-146 bpm; p = 0.006) and baseline testing (143, 140-146; p = 0.049) throughout the entire testing session (i.e., collapsed across all timepoints). Furthermore, HRV (rMSSD) the following morning after testing was significantly higher for the wbPBM session compared to placebo (p = 0.043). There were no differences in perceived recovery (p = 0.713) or stress (p = 0.978) scores between wbPBM and placebo. Implementing 20 min of wbPBM immediately prior to maximal bouts of anaerobic cycling did not improve performance (i.e., power output) or physiological responses (e.g., lactate). However, wbPBM elicited the ability to work at a higher heart rate throughout testing and seemed to enhance recovery through improved HRV the following morning.


Assuntos
Ciclismo , Ácido Láctico , Masculino , Feminino , Humanos , Estudos Cross-Over , Anaerobiose , Método Simples-Cego , Ciclismo/fisiologia , Frequência Cardíaca/fisiologia
3.
J Strength Cond Res ; 36(9): 2387-2402, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35916879

RESUMO

ABSTRACT: Merrigan, JJ, Stone, JD, Galster, SM, and Hagen, JA. Analyzing force-time curves: Comparison of commercially available automated software and custom MATLAB analyses. J Strength Cond Res 36(9): 2387-2402, 2022-With the growing prevalence of commercial force plate solutions providing automated force-time curve analysis, it is critical to understand the level of agreement across techniques. Thus, this study directly compared commercial and custom software analyses across force-time curves. Twenty-four male and female subjects completed 6 trials of countermovement, squat, and drop jumps, and isometric mid-thigh pulls on the same force plate. Vertical ground reaction forces were analyzed by automated software from Vald Performance, Hawkin Dynamics, and custom MATLAB scripts. Trials were visually assessed to verify proper landmark identifications. Systematic and proportional bias among analyses were compared via least products regressions, Bland-Altman plots, and percent error. Hawkin Dynamics had subtle differences in analysis procedures and demonstrated low percent errors across all tests (<3% error), despite demonstrating systematic and proportional bias for several metrics. ForceDecks demonstrated larger percent differences and greater biases for several metrics. These errors likely result from different identification of movement initiation, system weight, and integration techniques, which causes error to subsequent landmark identifications (e.g., braking/propulsive phases) and respective force-time metrics. Many metrics were in agreement between devices, such as isometric mid-thigh pull peak force consistently within 1 N across analyses, but some metrics are difficult and incomparable across software analyses (i.e., rate of force development). Overall, many metrics were in agreement across each commercial software and custom MATLAB analyses after visually confirming landmarks. However, because of inconsistencies, it is important to only compare metrics that are in agreement across software analyses when absolutely necessary.


Assuntos
Força Muscular , Coxa da Perna , Feminino , Humanos , Masculino , Movimento , Postura , Software
4.
J Strength Cond Res ; 36(1): 277-283, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34941613

RESUMO

ABSTRACT: Merrigan, JJ, Stone, JD, Wagle, JP, Hornsby, WG, Ramadan, J, Joseph, M, and Hagen, JA. Using random forest regression to determine influential force-time metrics for countermovement jump height: a technical report. J Strength Cond Res 36(1): 277-283, 2022-The purpose of this study was to indicate the most influential force-time metrics on countermovement jump (CMJ) height using multiple statistical procedures. Eighty-two National Collegiate Athletic Association Division I American football players performed 2 maximal-effort, no arm-swing, CMJs on force plates. The average absolute and relative (i.e., power/body mass) metrics were included as predictor variables, whereas jump height was the dependent variable within regression models (p < 0.05). Best subsets regression (8 metrics, R2 = 0.95) included less metrics compared with stepwise regression (18 metrics, R2 = 0.96), while explaining similar overall variance in jump height (p = 0.083). Random forest regression (RFR) models included 8 metrics, explained ∼93% of jump height variance, and were not significantly different than best subsets regression models (p > 0.05). Players achieved higher CMJs by attaining a deeper, faster, and more forceful countermovement with lower eccentric-to-concentric force ratios. An additional RFR was conducted on metrics scaled to body mass and revealed relative mean and peak concentric power to be the most influential. For exploratory purposes, additional RFR were run for each positional group and suggested that the most influential variables may differ across positions. Thus, developing power output capabilities and providing coaching to improve technique during the countermovement may maximize jump height capabilities. Scientists and practitioners may use best subsets or RFR analyses to help identify which force-time metrics are of interest to reduce the selectable number of multicollinear force-time metrics to monitor. These results may inform their training programs to maximize individual performance capabilities.


Assuntos
Desempenho Atlético , Futebol Americano , Tutoria , Benchmarking , Estatura , Humanos , Força Muscular
5.
J Strength Cond Res ; 36(2): 411-419, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34798642

RESUMO

ABSTRACT: Merrigan, JJ, Rentz, LE, Hornsby, WG, Wagle, JP, Stone, JD, Smith, HT, Galster, SM, Joseph, M, and Hagen, JA. Comparisons of countermovement jump force-time characteristics among NCAA Division I American football athletes: use of principal component analysis. J Strength Cond Res 36(2): 411-419, 2022-This study aimed to reduce the dimensionality of countermovement jump (CMJ) force-time characteristics and evaluate differences among positional groups (skills, hybrid, linemen, and specialists) within National Collegiate Athletic Association (NCAA) division I American football. Eighty-two football athletes performed 2 maximal effort, no arm-swing, CMJs on force plates. The average absolute and relative (e.g., power/body mass) metrics were analyzed using analysis of variance and principal component analysis procedures (p < 0.05). Linemen had the heaviest body mass and produced greater absolute forces than hybrid and skills but had lower propulsive abilities demonstrated by longer propulsive phase durations and greater eccentric to concentric mean force ratios. Skills and hybrid produced the most relative concentric and eccentric forces and power, as well as modified reactive strength indexes (RSIMOD). Skills (46.7 ± 4.6 cm) achieved the highest jump height compared with hybrid (42.8 ± 5.5 cm), specialists (38.7 ± 4.0 cm), and linemen (34.1 ± 5.3 cm). Four principal components explained 89.5% of the variance in force-time metrics. Dimensions were described as the (a) explosive transferability to concentric power (RSIMOD, concentric power, and eccentric to concentric forces) (b) powerful eccentric loading (eccentric power and velocity), (c) countermovement strategy (depth and duration), and (d) jump height and power. The many positional differences in CMJ force-time characteristics may inform strength and conditioning program designs tailored to each position and identify important explanatory metrics to routinely monitor by position. The overwhelming number of force-time metrics to select from may be reduced using principal component analysis methods, although practitioners should still consider the various metric's applicability and reliability.


Assuntos
Desempenho Atlético , Futebol Americano , Atletas , Humanos , Força Muscular , Análise de Componente Principal , Reprodutibilidade dos Testes
6.
Langmuir ; 34(5): 2139-2146, 2018 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-29283584

RESUMO

DNA aptamers that bind biomolecular targets are of interest as the recognition element in colorimetric sensors based on gold nanoparticles (AuNP), where sensor functionality is related to changes in AuNP colloidal stability upon target binding. In order to understand the role of target binding on DNA-AuNP colloidal stability, we have used high-resolution NMR to characterize the interactions of the 36 nucleotide cocaine-binding aptamer (MN4) and related aptamers with AuNPs, cocaine, and cocaine metabolites. Changes in the aptamer imino proton NMR spectra with low (20 nM) concentrations of AuNP show that the aptamers undergo fast-exchange adsorption on the nanoparticle surface. An analysis of the spectral changes and the comparison with modified MN4 aptamers shows that the AuNP binding domain is localized on stem two of the three-stemmed aptamer. The identification of an AuNP recognition domain allows for the incorporation of AuNP binding functionality into a wide variety of aptamers. AuNP-induced spectral changes are not observed for the aptamer-AuNP mixtures in the presence of cocaine, demonstrating that aptamer absorption on the AuNP surface is modulated by aptamer-target interactions. The data also show that the DNA-AuNP interactions and sensor functionality are critically dependent on aptamer folding.


Assuntos
Aptâmeros de Nucleotídeos/química , Ouro/química , Nanopartículas Metálicas/química , Aptâmeros de Nucleotídeos/genética , Sequência de Bases , Concentração Osmolar , Temperatura
7.
Sensors (Basel) ; 17(4)2017 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-28346350

RESUMO

Neurotransmitters detection is critical to understanding communication between the brain and peripheral tissue. Serotonin is a key neurotransmitter linked to a number of conditions, but a full understanding of its role in disease is still lacking. The development of fast and selective serotonin detection platforms will provide researchers with tools to monitor serotonin in individuals before and after treatment for the condition of interest. Aptamer-gold nanoparticles conjugates that responded colorimetrically to serotonin with minimal response to its metabolite and other neurotransmitters were designed by simply adsorbing the DNA on the surface of AuNPs. A plasmonic assay for serotonin detection was designed with a response to biologically relevant serotonin levels. Importantly, the assay performance was not compromised when tested in filtered spiked fetal bovine serum as a mimic of biofluids. This work shows that these simple and stable Apt-AuNP conjugates are promising tools to develop fast assays for point-of-care and personalized diagnostics applications.


Assuntos
Nanopartículas Metálicas , Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Colorimetria , Ouro , Humanos , Serotonina
8.
Sensors (Basel) ; 17(9)2017 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-28832512

RESUMO

In this work, we developed an assay to determine if an arbitrary white powder is a controlled substance, given the plasmonic response of aptamer-gold nanoparticle conjugates (Apt-AuNPs). Toward this end, we designed Apt-AuNPs with specific a response to common controlled substances without cross reactivity to chemicals typically used as fillers in street formulations. Plasmonic sensor variation was shown to produce unique data fingerprints for each chemical analyzed, supporting the application of multivariate statistical techniques to annotate unknown samples by chemical similarity. Importantly, the assay takes less than fifteen minutes to run, and requires only a few micrograms of the material, making the proposed assay easily deployable in field operations.

9.
Analyst ; 139(23): 6214-22, 2014 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-25319608

RESUMO

The utilization of the plasmonic response of aptamer-gold nanoparticle conjugates (Apt-AuNPs) to design cross-reactive arrays for fingerprint identification of small molecular targets was demonstrated for the first time. Four aptamers with different structural features previously selected to bind different targets were used in combination with AuNPs by adsorbing the DNA on the AuNPs surface. The optimized response of the Apt-AuNPs to the analytes showed that, depending on the specific aptamer used, target binding by the aptamer could result in an increase or decrease of Apt-AuNPs stability. These Apt-AuNPs showed the ability to recognize different analytes with different affinities, generating fingerprints that allowed unambiguous analyte identification with response times in less than fifteen minutes. Importantly, it was observed that it was not necessary to select an aptamer per analyte of interest to generate differentiable signatures, but a subset of aptamers could be used to identify a larger number of analytes. The data was analyzed using principal component analysis, showing efficient clustering of the different datasets for qualitative and quantitative identification. This work opens the door to using these Apt-AuNPs in point of care diagnostics applications where fast sensors with easy to read outputs are needed.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/instrumentação , Ouro/química , Nanopartículas Metálicas/química , Adenosina/química , Adsorção , Técnicas Biossensoriais/métodos , Ácido Cólico/química , Citratos , Colorimetria , Estradiol/química , Estrutura Molecular , Riboflavina/química
10.
Nanotechnology ; 25(9): 094005, 2014 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-24521939

RESUMO

Pentacene-based organic thin-film transistors (OTFTs) were fabricated on several types of flexible substrate: commercial photo paper, ultra-smooth specialty paper and ultra-thin (100 µM) flexible glass. The transistors were fabricated entirely through dry-step processing. The transconductance and field-effect mobility of OTFTs on photo paper reached values of ∼0.52 mS m(-1) and ∼ 0.1 cm(2) V (-1) s(-1), respectively. Preliminary results on the lifetime of OTFTs on photo paper yielded stable transconductance and mobility values over a period of more than 250 h. The comparable characteristics of OTFTs fabricated on widely available, low cost paper and high quality expensive liquid crystal display glass indicate the potential importance of cellulose-based electronic devices.

11.
J Athl Train ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38835321

RESUMO

Athletic trainers are increasingly utilized in non-traditional settings, such as in law enforcement, where they can contribute to healthcare management, including concussion management of law enforcement officers (LEOs). Despite the prevalence of concussions among LEOs, there is a notable gap in concussion management guidelines for this population. LEOs may lack the education and resources necessary for concussion recognition and proper management. Drawing on advancements in concussion management in athletes and military personnel, here we present a comprehensive framework for concussion management in LEOs encompassing concussion education, a graduated return to duty (RTD) protocol, and considerations for implementation and documentation specific to law enforcement. We also present several barriers and facilitators to implementation. Due to job requirements, it is critical for law enforcement organizations and their medical providers to adopt a concussion management strategy. Without proper concussion management, LEOs may risk subsequent injury and/or suffer from prolonged recovery and adverse long-term outcomes.

12.
Explore (NY) ; 20(5): 103022, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38981179

RESUMO

CONTEXT: Health care providers (HCP) experience high stress and burnout rates. Mindfulness Based Interventions (MBI) with biofeedback may help improve resiliency but require further research. DESIGN AND STUDY PARTICIPANTS: Aims were to evaluate changes in sleep patterns, nocturnal physiology, stress, mood disturbances, and perceived experience with biofeedback during the Mindfulness in Motion (MIM) intervention. Data from 66 HCP were included after removing those below 75 % compliance with wearable sensors and wellness surveys. Participants were enrolled in MIM, including eight weekly one-hour virtually delivered synchronous group meetings and ∼10 min of mindfulness home practice at least 3 times per week using a mobile application. Participants wore wearable sensors to monitor sleep and nocturnal physiology and completed short daily stress and mood disturbances. RESULTS: According to mixed effect models, no sleep nor physiological metrics changed across MIM (p > 0.05). More time was spent in bed after MIM sessions (8.33±1.03 h) compared to night before (8.05±0.93 h; p = 0.040). Heart rate variability was lower nights after MIM (33.00±15.59 ms) compared to nights before (34.50±17.04 ms; p = 0.004) but was not clinically meaningful (effect= 0.033). Significant reductions were noted in perceived stress at weeks 3 through 8 compared to Baseline and lower Total Mood Disturbance at weeks 3, 5, 6, and 8 compared to Baseline (p < 0.001). CONCLUSIONS: Participating in the MIM with mobile applications and wearable sensors reduced perceived stress and mood disturbances but did not induce physiological changes. Additional research is warranted to further evaluate objective physiological outcomes while controlling for confounding variables (e.g., alcohol, medications).


Assuntos
Biorretroalimentação Psicológica , Pessoal de Saúde , Atenção Plena , Sono , Estresse Psicológico , Humanos , Atenção Plena/métodos , Masculino , Feminino , Biorretroalimentação Psicológica/métodos , Adulto , Pessoal de Saúde/psicologia , Estresse Psicológico/terapia , Pessoa de Meia-Idade , Sono/fisiologia , Frequência Cardíaca/fisiologia , Esgotamento Profissional/terapia , Esgotamento Profissional/prevenção & controle , Dispositivos Eletrônicos Vestíveis , Aplicativos Móveis
13.
Anal Chem ; 85(23): 11634-42, 2013 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-24206087

RESUMO

Monitoring aspects of human performance during various activities has recently become a highly investigated research area. Many new commercial products are available now to monitor human physical activity or responses while performing activities ranging from playing sports, to driving, and even sleeping. However, monitoring cognitive performance biomarkers, such as neuropeptides, is still an emerging field due to the complicated sample collection and processing, as well as the need for a clinical lab to perform analysis. Enzyme-linked immunosorbent assays (ELISAs) provide specific detection of biomolecules with high sensitivity (picomolar concentrations). Even with the advantage of high sensitivity, most ELISAs need to be performed in a laboratory setting and require around 6 h to complete. Transitioning this assay to a platform where it reduces cost, shortens assay time, and is able to be performed outside a lab is invaluable. Recently developed paper diagnostics provide an inexpensive platform on which to perform ELISAs; however, the major limiting factor for moving out of the laboratory environment is the measurement and analysis instrumentation. Using something as simple as a digital camera or camera-enabled Windows- or Android-based tablets, we are able to image paper-based ELISAs (P-ELISAs), perform image analysis, and produce response curves with high correlation to target biomolecule concentration in the 10 pM range. Neuropeptide Y detection was performed. Additionally, silver enhancement of Au NPs conjugated with IgG antibodies showed a concentration-dependent response to IgG, thus eliminating the need for an enzyme-substrate system. Automated image analysis and quantification of antigen concentrations are able to be performed on Windows- and Android-based mobile platforms.


Assuntos
Neuropeptídeo Y/análise , Papel , Desempenho Psicomotor , Biomarcadores/análise , Biomarcadores/química , Biomarcadores/metabolismo , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Humanos , Neuropeptídeo Y/metabolismo , Saliva/química , Saliva/metabolismo
14.
Ann Biomed Eng ; 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37847420

RESUMO

Law enforcement cadets (LECs) complete weeks of subject control technique training. Similar sport-related combat training has been shown to expose participants to head acceleration events (HAEs) that have potential to result in short- and long-term impairments. The purpose of this study was to describe the number and magnitude of HAEs in LECs throughout their training. 37 LECs (7 females; age = 30.6 ± 8.8 years; BMI = 30.0 ± 6.0) were recruited from a law enforcement organization. Participants wore instrumented mouthguards, which recorded all HAEs exceeding a resultant 5 g threshold for training sessions with the potential for HAEs. Participants completed three defensive tactics (DT) training sessions, a DT skill assessment (DTA), and three boxing sessions. Outcome measures included the number of HAEs, peak linear acceleration (PLA), and peak rotational velocity (PRV). There were 2758 true-positive HAEs recorded across the duration of the study. Boxing sessions accounted for 63.7% of all true-positive HAEs, while DT accounted for 31.4% and DTA accounted for 4.9%. Boxing sessions resulted in a higher number of HAEs per session (F2,28 = 48.588, p < 0.001, ηp2 = 0.776), and higher median PLA (F2,28 = 8.609, p = 0.001, ηp2 = 0.381) and median PRV (F2,28 = 11.297, p < 0.001, ηp2 = 0.447) than DT and DTA. The LECs experience a high number of HAEs, particularly during boxing sessions. Although this training is necessary for job duties, HAE monitoring may lead to modifications in training structure to improve participant safety and enhance recovery.

15.
Glob Adv Integr Med Health ; 12: 27536130231187636, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37434793

RESUMO

Background: Mindfulness in Motion (MIM) is a workplace resilience-building intervention that has shown reductions in perceived stress and burnout, as well as increased resilience and work engagement in health care workers. Objective: To evaluate effects of MIM delivered in a synchronous virtual format on self-reported respiratory rates (RR), as well as perceived stress and resiliency of health care workers. Methods: Breath counts were self-reported by 275 participants before and after 8 weekly MIM sessions. MIM was delivered virtually in a group format as a structured, evidence-based workplace intervention including a variety of mindfulness, relaxation, and resilience-building techniques. Participants counted their breaths for 30 seconds, which was then multiplied by 2 to report RR. Additionally, participants completed Perceived Stress Scale and Connor-Davidson Resiliency Scale. Results: According to mixed effect analyses there were main effects of MIM Session (P < .001) and Weeks (P < .001), but no Session by Week interaction (P = .489) on RR. On average, RR prior to MIM sessions were reduced from 13.24 bpm (95% CI = 12.94, 13.55 bpm) to 9.69 bpm (95% CI = 9.39, 9.99 bpm). When comparing average Pre-MIM and Post-MIM RR throughout the MIM intervention, Week-2 (mean = 12.34; 95% CI = 11.89, 12.79 bpm) was not significantly different than Week-1 (mean = 12.78; 95% CI = 12.34, 13.23 bpm), but Week-3 through Week-8 demonstrated significantly lower average Pre-MIM and Post-MIM RR compared to Week-1 (average weekly difference range: 1.36 to 2.48 bpm, P < .05). Perceived stress was reduced from Week-1 (17.52 ± 6.25) to after Week-8 (13.52 ± 6.04; P < .001), while perceived resiliency was increased from Week-1 (11.30 ± 5.14) to after Week-8 (19.29 ± 2.58); P < .001). Conclusion: Thus far, completion of MIM sessions has shown acute and long-term effects on self-reported RR, but more research is required to determine the extent of improved parasympathetic (relaxed) states. Collectively, this work has shown value for mind-body stress mitigation and resiliency-building in high stress acute health care environments.

16.
Front Sports Act Living ; 4: 795897, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35252854

RESUMO

The primary purpose was to simplify external load data obtained during Division-I (DI) basketball competitions via principal component analysis (PCA). A secondary purpose was to determine if the PCA results were sensitive to load demands of different positional groups (POS). Data comprised 229 observations obtained from 10 men's basketball athletes participating in NCAA DI competitions. Each athlete donned an inertial measurement unit that was affixed to the same location on their shorts prior to competition. The PCA revealed two factors that possessed eigenvalues >1.0 and explained 81.42% of the total variance. The first factor comprised total decelerations (totDEC, 0.94), average speed (avgSPD, 0.90), total accelerations (totACC, 0.85), total mechanical load (totMECH, 0.84), and total jump load (totJUMP, 0.78). Maximum speed (maxSPD, 0.94) was the lone contributor to the second factor. Based on the PCA, external load variables were included in a multinomial logistic regression that predicted POS (Overall model, p < 0.0001; AUCcenters = 0.93, AUCguards = 0.88, AUCforwards = 0.80), but only maxSPD, totDEC, totJUMP, and totMECH were significant contributors to the model's success (p < 0.0001 for each). Even with the high significance, the model still had some issues differentiating between guards and forwards, as in-game demands often overlap between the two positions. Nevertheless, the PCA was effective at simplifying a large external load dataset collected on NCAA DI men's basketball athletes. These data revealed that maxSPD, totDEC, totJUMP, and totMECH were the most sensitive to positional differences during competitions. To best characterize competition demands, such variables may be used to individualize training and recovery regimens most effectively.

17.
Sensors (Basel) ; 11(7): 6645-55, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22163977

RESUMO

Zinc oxide field effect transistors (ZnO-FET), covalently functionalized with single stranded DNA aptamers, provide a highly selective platform for label-free small molecule sensing. The nanostructured surface morphology of ZnO provides high sensitivity and room temperature deposition allows for a wide array of substrate types. Herein we demonstrate the selective detection of riboflavin down to the pM level in aqueous solution using the negative electrical current response of the ZnO-FET by covalently attaching a riboflavin binding aptamer to the surface. The response of the biofunctionalized ZnO-FET was tuned by attaching a redox tag (ferrocene) to the 3' terminus of the aptamer, resulting in positive current modulation upon exposure to riboflavin down to pM levels.


Assuntos
Técnicas Biossensoriais , Riboflavina/análise , Transistores Eletrônicos , Óxido de Zinco/química , Aptâmeros de Nucleotídeos/química , DNA de Cadeia Simples/química , Compostos Ferrosos/química , Metalocenos , Nanoestruturas
18.
Artigo em Inglês | MEDLINE | ID: mdl-34360435

RESUMO

Human performance optimization of tactical personnel requires accurate, meticulous, and effective monitoring of biological adaptations and systemic recovery. Due to an increased understanding of its importance and the commercial availability of assessment tools, the use of heart rate variability (HRV) to address this need is becoming more common in the tactical community. Measuring HRV is a non-invasive, practical method for objectively assessing a performer's readiness, workload, and recovery status; when combined with additional data sources and practitioner input, it provides an affordable and scalable solution for gaining actionable information to support the facilitation and maintenance of operational performance. This narrative review discusses the non-clinical use of HRV for assessing, monitoring, and interpreting autonomic nervous system resource availability, modulation, effectiveness, and efficiency in tactical populations. Broadly, HRV metrics represent a complex series of interactions resulting from internal and external stimuli; therefore, a general overview of HRV applications in tactical personnel is discussed, including the influence of occupational specific demands, interactions between cognitive and physical domains, and recommendations on implementing HRV for training and recovery insights into critical health and performance outcomes.


Assuntos
Sistema Nervoso Autônomo , Carga de Trabalho , Frequência Cardíaca , Humanos , Monitorização Fisiológica
19.
Front Sports Act Living ; 3: 585870, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33733234

RESUMO

Commercial off-the shelf (COTS) wearable devices continue development at unprecedented rates. An unfortunate consequence of their rapid commercialization is the lack of independent, third-party accuracy verification for reported physiological metrics of interest, such as heart rate (HR) and heart rate variability (HRV). To address these shortcomings, the present study examined the accuracy of seven COTS devices in assessing resting-state HR and root mean square of successive differences (rMSSD). Five healthy young adults generated 148 total trials, each of which compared COTS devices against a validation standard, multi-lead electrocardiogram (mECG). All devices accurately reported mean HR, according to absolute percent error summary statistics, although the highest mean absolute percent error (MAPE) was observed for CameraHRV (17.26%). The next highest MAPE for HR was nearly 15% less (HRV4Training, 2.34%). When measuring rMSSD, MAPE was again the highest for CameraHRV [112.36%, concordance correlation coefficient (CCC): 0.04], while the lowest MAPEs observed were from HRV4Training (4.10%; CCC: 0.98) and OURA (6.84%; CCC: 0.91). Our findings support extant literature that exposes varying degrees of veracity among COTS devices. To thoroughly address questionable claims from manufacturers, elucidate the accuracy of data parameters, and maximize the real-world applicative value of emerging devices, future research must continually evaluate COTS devices.

20.
Cureus ; 13(5): e14838, 2021 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-34123609

RESUMO

A growing number of studies utilizing wearable technologies are examining the influence of the autonomic nervous system (ANS) on intense training, recovery, and injury risk. Exercise biometric (EB) data were collected on collegiate, female soccer players during a preseason camp. One player sustained an anterior cruciate ligament (ACL) injury. Baseline anthropometric and EB data were compared to non-injured, position-matched teammates. All players had similar baseline testing. The injured athlete had a higher body mass index (BMI) and slower vision reaction time (RT). On the day of her injury (DOI), relative percentage heart rate recovery (tHRR) between intense training sets was calculated. Relative percentage tHRR was much lower for the injured athlete, indicating reduced recovery between training sets immediately prior to the injury. Also on DOI, the injured athlete had a lower glomerular filtration rate (GFR). In addition to BMI and RT differences, the lower relative percentage tHRR and GFR on the DOI observed for the injured athlete may reflect an imbalanced ANS recovery, and potentially to risk factors leading to her ACL injury.

SELEÇÃO DE REFERÊNCIAS