Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38881496

RESUMO

BACKGROUND: Artificial intelligence, particularly deep learning (DL), has immense potential to improve the interpretation of transthoracic echocardiography (TTE). Mitral regurgitation (MR) is the most common valvular heart disease and presents unique challenges for DL, including the integration of multiple video-level assessments into a final study-level classification. METHODS: A novel DL system was developed to intake complete TTEs, identify color MR Doppler videos, and determine MR severity on a 4-step ordinal scale (none/trace, mild, moderate, and severe) using the reading cardiologist as a reference standard. This DL system was tested in internal and external test sets with performance assessed by agreement with the reading cardiologist, weighted κ, and area under the receiver-operating characteristic curve for binary classification of both moderate or greater and severe MR. In addition to the primary 4-step model, a 6-step MR assessment model was studied with the addition of the intermediate MR classes of mild-moderate and moderate-severe with performance assessed by both exact agreement and ±1 step agreement with the clinical MR interpretation. RESULTS: A total of 61 689 TTEs were split into train (n=43 811), validation (n=8891), and internal test (n=8987) sets with an additional external test set of 8208 TTEs. The model had high performance in MR classification in internal (exact accuracy, 82%; κ=0.84; area under the receiver-operating characteristic curve, 0.98 for moderate/severe MR) and external test sets (exact accuracy, 79%; κ=0.80; area under the receiver-operating characteristic curve, 0.98 for moderate or greater MR). Most (63% internal and 66% external) misclassification disagreements were between none/trace and mild MR. MR classification accuracy was slightly higher using multiple TTE views (accuracy, 82%) than with only apical 4-chamber views (accuracy, 80%). In subset analyses, the model was accurate in the classification of both primary and secondary MR with slightly lower performance in cases of eccentric MR. In the analysis of the 6-step classification system, the exact accuracy was 80% and 76% with a ±1 step agreement of 99% and 98% in the internal and external test set, respectively. CONCLUSIONS: This end-to-end DL system can intake entire echocardiogram studies to accurately classify MR severity and may be useful in helping clinicians refine MR assessments.

2.
Circulation ; 146(1): 36-47, 2022 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-35533093

RESUMO

BACKGROUND: Timely diagnosis of structural heart disease improves patient outcomes, yet many remain underdiagnosed. While population screening with echocardiography is impractical, ECG-based prediction models can help target high-risk patients. We developed a novel ECG-based machine learning approach to predict multiple structural heart conditions, hypothesizing that a composite model would yield higher prevalence and positive predictive values to facilitate meaningful recommendations for echocardiography. METHODS: Using 2 232 130 ECGs linked to electronic health records and echocardiography reports from 484 765 adults between 1984 to 2021, we trained machine learning models to predict the presence or absence of any of 7 echocardiography-confirmed diseases within 1 year. This composite label included the following: moderate or severe valvular disease (aortic/mitral stenosis or regurgitation, tricuspid regurgitation), reduced ejection fraction <50%, or interventricular septal thickness >15 mm. We tested various combinations of input features (demographics, laboratory values, structured ECG data, ECG traces) and evaluated model performance using 5-fold cross-validation, multisite validation trained on 1 site and tested on 10 independent sites, and simulated retrospective deployment trained on pre-2010 data and deployed in 2010. RESULTS: Our composite rECHOmmend model used age, sex, and ECG traces and had a 0.91 area under the receiver operating characteristic curve and a 42% positive predictive value at 90% sensitivity, with a composite label prevalence of 17.9%. Individual disease models had area under the receiver operating characteristic curves from 0.86 to 0.93 and lower positive predictive values from 1% to 31%. Area under the receiver operating characteristic curves for models using different input features ranged from 0.80 to 0.93, increasing with additional features. Multisite validation showed similar results to cross-validation, with an aggregate area under the receiver operating characteristic curve of 0.91 across our independent test set of 10 clinical sites after training on a separate site. Our simulated retrospective deployment showed that for ECGs acquired in patients without preexisting structural heart disease in the year 2010, 11% were classified as high risk and 41% (4.5% of total patients) developed true echocardiography-confirmed disease within 1 year. CONCLUSIONS: An ECG-based machine learning model using a composite end point can identify a high-risk population for having undiagnosed, clinically significant structural heart disease while outperforming single-disease models and improving practical utility with higher positive predictive values. This approach can facilitate targeted screening with echocardiography to improve underdiagnosis of structural heart disease.


Assuntos
Cardiopatias , Aprendizado de Máquina , Adulto , Ecocardiografia , Eletrocardiografia , Cardiopatias/diagnóstico por imagem , Cardiopatias/epidemiologia , Humanos , Estudos Retrospectivos
3.
Circulation ; 145(20): 1524-1533, 2022 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-35389749

RESUMO

BACKGROUND: Rare sequence variation in genes underlying cardiac repolarization and common polygenic variation influence QT interval duration. However, current clinical genetic testing of individuals with unexplained QT prolongation is restricted to examination of monogenic rare variants. The recent emergence of large-scale biorepositories with sequence data enables examination of the joint contribution of rare and common variations to the QT interval in the population. METHODS: We performed a genome-wide association study of the QTc in 84 630 UK Biobank participants and created a polygenic risk score (PRS). Among 26 976 participants with whole-genome sequencing and ECG data in the TOPMed (Trans-Omics for Precision Medicine) program, we identified 160 carriers of putative pathogenic rare variants in 10 genes known to be associated with the QT interval. We examined QTc associations with the PRS and with rare variants in TOPMed. RESULTS: Fifty-four independent loci were identified by genome-wide association study in the UK Biobank. Twenty-one loci were novel, of which 12 were replicated in TOPMed. The PRS composed of 1 110 494 common variants was significantly associated with the QTc in TOPMed (ΔQTc/decile of PRS=1.4 ms [95% CI, 1.3 to 1.5]; P=1.1×10-196). Carriers of putative pathogenic rare variants had longer QTc than noncarriers (ΔQTc=10.9 ms [95% CI, 7.4 to 14.4]). Of individuals with QTc>480 ms, 23.7% carried either a monogenic rare variant or had a PRS in the top decile (3.4% monogenic, 21% top decile of PRS). CONCLUSIONS: QTc duration in the population is influenced by both rare variants in genes underlying cardiac repolarization and polygenic risk, with a sizeable contribution from polygenic risk. Comprehensive assessment of the genetic determinants of QTc prolongation includes incorporation of both polygenic and monogenic risk.


Assuntos
Estudo de Associação Genômica Ampla , Síndrome do QT Longo , Eletrocardiografia , Heterozigoto , Humanos , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/genética , Herança Multifatorial , Sequenciamento Completo do Genoma
4.
J Electrocardiol ; 76: 61-65, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36436476

RESUMO

BACKGROUND: Several large trials have employed age or clinical features to select patients for atrial fibrillation (AF) screening to reduce strokes. We hypothesized that a machine learning (ML) model trained to predict AF risk from 12­lead electrocardiogram (ECG) would be more efficient than criteria based on clinical variables in indicating a population for AF screening to potentially prevent AF-related stroke. METHODS: We retrospectively included all patients with clinical encounters in Geisinger without a prior history of AF. Incidence of AF within 1 year and AF-related strokes within 3 years of the encounter were identified. AF-related stroke was defined as a stroke where AF was diagnosed at the time of stroke or within a year after the stroke. The efficiency of five methods was evaluated for selecting a cohort for AF screening. The methods were selected from four clinical trials (mSToPS, GUARD-AF, SCREEN-AF and STROKESTOP) and the ECG-based ML model. We simulated patient selection for the five methods between the years 2011 and 2014 and evaluated outcomes for 1 year intervals between 2012 and 2015, resulting in a total of twenty 1-year periods. Patients were considered eligible if they met the criteria before the start of the given 1-year period or within that period. The primary outcomes were numbers needed to screen (NNS) for AF and AF-associated stroke. RESULTS: The clinical trial models indicated large proportions of the population with a prior ECG for AF screening (up to 31%), coinciding with NNS ranging from 14 to 18 for AF and 249-359 for AF-associated stroke. At comparable sensitivity, the ECG ML model indicated a modest number of patients for screening (14%) and had the highest efficiency in NNS for AF (7.3; up to 60% reduction) and AF-associated stroke (223; up to 38% reduction). CONCLUSIONS: An ECG-based ML risk prediction model is more efficient than contemporary AF-screening criteria based on age alone or age and clinical features at indicating a population for AF screening to potentially prevent AF-related strokes.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Eletrocardiografia , Estudos Retrospectivos , Programas de Rastreamento , Acidente Vascular Cerebral/diagnóstico
5.
Circulation ; 143(13): 1287-1298, 2021 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-33588584

RESUMO

BACKGROUND: Atrial fibrillation (AF) is associated with substantial morbidity, especially when it goes undetected. If new-onset AF could be predicted, targeted screening could be used to find it early. We hypothesized that a deep neural network could predict new-onset AF from the resting 12-lead ECG and that this prediction may help identify those at risk of AF-related stroke. METHODS: We used 1.6 M resting 12-lead digital ECG traces from 430 000 patients collected from 1984 to 2019. Deep neural networks were trained to predict new-onset AF (within 1 year) in patients without a history of AF. Performance was evaluated using areas under the receiver operating characteristic curve and precision-recall curve. We performed an incidence-free survival analysis for a period of 30 years following the ECG stratified by model predictions. To simulate real-world deployment, we trained a separate model using all ECGs before 2010 and evaluated model performance on a test set of ECGs from 2010 through 2014 that were linked to our stroke registry. We identified the patients at risk for AF-related stroke among those predicted to be high risk for AF by the model at different prediction thresholds. RESULTS: The area under the receiver operating characteristic curve and area under the precision-recall curve were 0.85 and 0.22, respectively, for predicting new-onset AF within 1 year of an ECG. The hazard ratio for the predicted high- versus low-risk groups over a 30-year span was 7.2 (95% CI, 6.9-7.6). In a simulated deployment scenario, the model predicted new-onset AF at 1 year with a sensitivity of 69% and specificity of 81%. The number needed to screen to find 1 new case of AF was 9. This model predicted patients at high risk for new-onset AF in 62% of all patients who experienced an AF-related stroke within 3 years of the index ECG. CONCLUSIONS: Deep learning can predict new-onset AF from the 12-lead ECG in patients with no previous history of AF. This prediction may help identify patients at risk for AF-related strokes.


Assuntos
Fibrilação Atrial/diagnóstico , Aprendizado Profundo/normas , Acidente Vascular Cerebral/etiologia , Fibrilação Atrial/complicações , Eletrocardiografia , Feminino , Humanos , Masculino , Redes Neurais de Computação , Acidente Vascular Cerebral/mortalidade , Análise de Sobrevida
6.
Genet Med ; 23(10): 1961-1968, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34120153

RESUMO

PURPOSE: The genetic architecture of Plakophilin 2 (PKP2) cardiomyopathy can inform our understanding of its variant pathogenicity and protein function. METHODS: We assess the gene-wide and regional association of truncating and missense variants in PKP2 with arrhythmogenic cardiomyopathy (ACM), and arrhythmogenic right ventricular cardiomyopathy (ARVC) specifically. A discovery data set compares genetic testing requisitions to gnomAD. Validation is performed in a rigorously phenotyped definite ARVC cohort and non-ACM individuals in the Geisinger MyCode cohort. RESULTS: The etiologic fraction (EF) of ACM-related diagnoses from truncating variants in PKP2 is significant (0.85 [0.80,0.88], p < 2 × 10-16), increases for ARVC specifically (EF = 0.96 [0.94,0.97], p < 2 × 10-16), and is highest in definite ARVC versus non-ACM individuals (EF = 1.00 [1.00,1.00], p < 2 × 10-16). Regions of missense variation enriched for ACM probands include known functional domains and the C-terminus, which was not previously known to contain a functional domain. No regional enrichment was identified for truncating variants. CONCLUSION: This multicohort evaluation of the genetic architecture of PKP2 demonstrates the specificity of PKP2 truncating variants for ARVC within the ACM disease spectrum. We identify the PKP2 C-terminus as a potential functional domain and find that truncating variants likely cause disease irrespective of transcript position.


Assuntos
Displasia Arritmogênica Ventricular Direita , Cardiomiopatias , Placofilinas , Displasia Arritmogênica Ventricular Direita/genética , Testes Genéticos , Humanos , Fenótipo , Placofilinas/genética
7.
J Genet Couns ; 30(3): 634-644, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33786929

RESUMO

Emerging genetic testing delivery models have enabled individuals to receive testing without a medical indication. This article will highlight key considerations for patient care in the setting of adult patients with positive results for monogenic disease identified through genomic screening. Suggestions for how to adapt genetic counseling to a genomic screening population will encompass topics such as phenotyping, risk assessments, and the use of existing guidelines and resources. Case examples will demonstrate principles of genotype-first patient care.


Assuntos
Aconselhamento Genético , Testes Genéticos , Adulto , Genômica , Humanos
8.
BMC Med Inform Decis Mak ; 21(1): 156, 2021 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-33985483

RESUMO

BACKGROUND: Severity scores assess the acuity of critical illness by penalizing for the deviation of physiologic measurements from normal and aggregating these penalties (also called "weights" or "subscores") into a final score (or probability) for quantifying the severity of critical illness (or the likelihood of in-hospital mortality). Although these simple additive models are human readable and interpretable, their predictive performance needs to be further improved. METHODS: We present OASIS +, a variant of the Oxford Acute Severity of Illness Score (OASIS) in which an ensemble of 200 decision trees is used to predict in-hospital mortality based on the 10 same clinical variables in OASIS. RESULTS: Using a test set of 9566 admissions extracted from the MIMIC-III database, we show that OASIS + outperforms nine previously developed severity scoring methods (including OASIS) in predicting in-hospital mortality. Furthermore, our results show that the supervised learning algorithms considered in our experiments demonstrated higher predictive performance when trained using the observed clinical variables as opposed to OASIS subscores. CONCLUSIONS: Our results suggest that there is room for improving the prognostic accuracy of the OASIS severity scores by replacing the simple linear additive scoring function with more sophisticated non-linear machine learning models such as RF and XGB.


Assuntos
Unidades de Terapia Intensiva , Aprendizado de Máquina , Mortalidade Hospitalar , Humanos , Prognóstico , Estudos Retrospectivos
9.
Eur Heart J ; 41(12): 1249-1257, 2020 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-31386109

RESUMO

AIMS: We investigated the relationship between clinically assessed left ventricular ejection fraction (LVEF) and survival in a large, heterogeneous clinical cohort. METHODS AND RESULTS: Physician-reported LVEF on 403 977 echocardiograms from 203 135 patients were linked to all-cause mortality using electronic health records (1998-2018) from US regional healthcare system. Cox proportional hazards regression was used for analyses while adjusting for many patient characteristics including age, sex, and relevant comorbidities. A dataset including 45 531 echocardiograms and 35 976 patients from New Zealand was used to provide independent validation of analyses. During follow-up of the US cohort, 46 258 (23%) patients who had undergone 108 578 (27%) echocardiograms died. Overall, adjusted hazard ratios (HR) for mortality showed a u-shaped relationship for LVEF with a nadir of risk at an LVEF of 60-65%, a HR of 1.71 [95% confidence interval (CI) 1.64-1.77] when ≥70% and a HR of 1.73 (95% CI 1.66-1.80) at LVEF of 35-40%. Similar relationships with a nadir at 60-65% were observed in the validation dataset as well as for each age group and both sexes. The results were similar after further adjustments for conditions associated with an elevated LVEF, including mitral regurgitation, increased wall thickness, and anaemia and when restricted to patients reported to have heart failure at the time of the echocardiogram. CONCLUSION: Deviation of LVEF from 60% to 65% is associated with poorer survival regardless of age, sex, or other relevant comorbidities such as heart failure. These results may herald the recognition of a new phenotype characterized by supra-normal LVEF.


Assuntos
Insuficiência Cardíaca , Função Ventricular Esquerda , Feminino , Humanos , Masculino , Nova Zelândia/epidemiologia , Prognóstico , Modelos de Riscos Proporcionais , Fatores de Risco , Volume Sistólico
10.
Circulation ; 140(1): 42-54, 2019 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-31216868

RESUMO

BACKGROUND: Truncating variants in the Titin gene (TTNtvs) are common in individuals with idiopathic dilated cardiomyopathy (DCM). However, a comprehensive genomics-first evaluation of the impact of TTNtvs in different clinical contexts, and the evaluation of modifiers such as genetic ancestry, has not been performed. METHODS: We reviewed whole exome sequence data for >71 000 individuals (61 040 from the Geisinger MyCode Community Health Initiative (2007 to present) and 10 273 from the PennMedicine BioBank (2013 to present) to identify anyone with TTNtvs. We further selected individuals with TTNtvs in exons highly expressed in the heart (proportion spliced in [PSI] >0.9). Using linked electronic health records, we evaluated associations of TTNtvs with diagnoses and quantitative echocardiographic measures, including subanalyses for individuals with and without DCM diagnoses. We also reviewed data from the Jackson Heart Study to validate specific analyses for individuals of African ancestry. RESULTS: Identified with a TTNtv in a highly expressed exon (hiPSI) were 1.2% individuals in PennMedicine BioBank and 0.6% at Geisinger. The presence of a hiPSI TTNtv was associated with increased odds of DCM in individuals of European ancestry (odds ratio [95% CI]: 18.7 [9.1-39.4] {PennMedicine BioBank} and 10.8 [7.0-16.0] {Geisinger}). hiPSI TTNtvs were not associated with DCM in individuals of African ancestry, despite a high DCM prevalence (odds ratio, 1.8 [0.2-13.7]; P=0.57). Among 244 individuals of European ancestry with DCM in PennMedicine BioBank, hiPSI TTNtv carriers had lower left ventricular ejection fraction (ß=-12%, P=3×10-7), and increased left ventricular diameter (ß=0.65 cm, P=9×10-3). In the Geisinger cohort, hiPSI TTNtv carriers without a cardiomyopathy diagnosis had more atrial fibrillation (odds ratio, 2.4 [1.6-3.6]) and heart failure (odds ratio, 3.8 [2.4-6.0]), and lower left ventricular ejection fraction (ß=-3.4%, P=1×10-7). CONCLUSIONS: Individuals of European ancestry with hiPSI TTNtv have an abnormal cardiac phenotype characterized by lower left ventricular ejection fraction, irrespective of the clinical manifestation of cardiomyopathy. Associations with arrhythmias, including atrial fibrillation, were observed even when controlling for cardiomyopathy diagnosis. In contrast, no association between hiPSI TTNtvs and DCM was discerned among individuals of African ancestry. Given these findings, clinical identification of hiPSI TTNtv carriers may alter clinical management strategies.


Assuntos
Conectina/genética , Registros Eletrônicos de Saúde , Variação Genética/genética , Genômica/métodos , Cardiopatias/genética , População Branca/genética , Adulto , Idoso , Estudos de Coortes , Registros Eletrônicos de Saúde/tendências , Feminino , Cardiopatias/diagnóstico , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade
11.
Genet Med ; 22(1): 102-111, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31383942

RESUMO

PURPOSE: "Genome-first" approaches, in which genetic sequencing is agnostically linked to associated phenotypes, can enhance our understanding of rare variants' contributions to disease. Loss-of-function variants in LMNA cause a range of rare diseases, including cardiomyopathy. METHODS: We leveraged exome sequencing from 11,451 unselected individuals in the Penn Medicine Biobank to associate rare variants in LMNA with diverse electronic health record (EHR)-derived phenotypes. We used Rare Exome Variant Ensemble Learner (REVEL) to annotate rare missense variants, clustered predicted deleterious and loss-of-function variants into a "gene burden" (N = 72 individuals), and performed a phenome-wide association study (PheWAS). Major findings were replicated in DiscovEHR. RESULTS: The LMNA gene burden was significantly associated with primary cardiomyopathy (p = 1.78E-11) and cardiac conduction disorders (p = 5.27E-07). Most patients had not been clinically diagnosed with LMNA cardiomyopathy. We also noted an association with chronic kidney disease (p = 1.13E-06). Regression analyses on echocardiography and serum labs revealed that LMNA variant carriers had dilated cardiomyopathy and primary renal disease. CONCLUSION: Pathogenic LMNA variants are an underdiagnosed cause of cardiomyopathy. We also find that LMNA loss of function may be a primary cause of renal disease. Finally, we show the value of aggregating rare, annotated variants into a gene burden and using PheWAS to identify novel ontologies for pleiotropic human genes.


Assuntos
Doença do Sistema de Condução Cardíaco/genética , Cardiomiopatias/genética , Sequenciamento do Exoma/métodos , Lamina Tipo A/genética , Mutação com Perda de Função , Insuficiência Renal Crônica/genética , Idoso , Comorbidade , Biologia Computacional/métodos , Registros Eletrônicos de Saúde , Feminino , Estudos de Associação Genética , Predisposição Genética para Doença , Humanos , Masculino , Pessoa de Meia-Idade , Mutação de Sentido Incorreto , Fenótipo
12.
J Cardiovasc Magn Reson ; 20(1): 63, 2018 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-30208894

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) feature tracking is increasingly used to quantify cardiac mechanics from cine CMR imaging, although validation against reference standard techniques has been limited. Furthermore, studies have suggested that commonly-derived metrics, such as peak global strain (reported in 63% of feature tracking studies), can be quantified using contours from just two frames - end-diastole (ED) and end-systole (ES) - without requiring tracking software. We hypothesized that mechanics derived from feature tracking would not agree with those derived from a reference standard (displacement-encoding with stimulated echoes (DENSE) imaging), and that peak strain from feature tracking would agree with that derived using simple processing of only ED and ES contours. METHODS: We retrospectively identified 88 participants with 186 pairs of DENSE and balanced steady state free precession (bSSFP) image slices acquired at the same locations across two institutions. Left ventricular (LV) strains, torsion, and dyssynchrony were quantified from both feature tracking (TomTec Imaging Systems, Circle Cardiovascular Imaging) and DENSE. Contour-based strains from bSSFP images were derived from ED and ES contours. Agreement was assessed with Bland-Altman analyses and coefficients of variation (CoV). All biases are reported in absolute percentage. RESULTS: Comparison results were similar for both vendor packages (TomTec and Circle), and thus only TomTec Imaging System data are reported in the abstract for simplicity. Compared to DENSE, mid-ventricular circumferential strain (Ecc) from feature tracking had acceptable agreement (bias: - 0.4%, p = 0.36, CoV: 11%). However, feature tracking significantly overestimated the magnitude of Ecc at the base (bias: - 4.0% absolute, p < 0.001, CoV: 18%) and apex (bias: - 2.4% absolute, p = 0.01, CoV: 15%), underestimated torsion (bias: - 1.4 deg/cm, p < 0.001, CoV: 41%), and overestimated dyssynchrony (bias: 26 ms, p < 0.001, CoV: 76%). Longitudinal strain (Ell) had borderline-acceptable agreement (bias: - 0.2%, p = 0.77, CoV: 19%). Contour-based strains had excellent agreement with feature tracking (biases: - 1.3-0.2%, CoVs: 3-7%). CONCLUSION: Compared to DENSE as a reference standard, feature tracking was inaccurate for quantification of apical and basal LV circumferential strains, longitudinal strain, torsion, and dyssynchrony. Feature tracking was only accurate for quantification of mid LV circumferential strain. Moreover, feature tracking is unnecessary for quantification of whole-slice strains (e.g. base, apex), since simplified processing of only ED and ES contours yields very similar results to those derived from feature tracking. Current feature tracking technology therefore has limited utility for quantification of cardiac mechanics.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Contração Miocárdica , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Adolescente , Adulto , Fenômenos Biomecânicos , Criança , Bases de Dados Factuais , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/normas , Kentucky , Imagem Cinética por Ressonância Magnética/normas , Masculino , Philadelphia , Valor Preditivo dos Testes , Padrões de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Torção Mecânica , Disfunção Ventricular Esquerda/fisiopatologia , Adulto Jovem
13.
JAMA ; 320(22): 2354-2364, 2018 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-30535219

RESUMO

Importance: Atrial fibrillation (AF) is the most common arrhythmia affecting 1% of the population. Young individuals with AF have a strong genetic association with the disease, but the mechanisms remain incompletely understood. Objective: To perform large-scale whole-genome sequencing to identify genetic variants related to AF. Design, Setting, and Participants: The National Heart, Lung, and Blood Institute's Trans-Omics for Precision Medicine Program includes longitudinal and cohort studies that underwent high-depth whole-genome sequencing between 2014 and 2017 in 18 526 individuals from the United States, Mexico, Puerto Rico, Costa Rica, Barbados, and Samoa. This case-control study included 2781 patients with early-onset AF from 9 studies and identified 4959 controls of European ancestry from the remaining participants. Results were replicated in the UK Biobank (346 546 participants) and the MyCode Study (42 782 participants). Exposures: Loss-of-function (LOF) variants in genes at AF loci and common genetic variation across the whole genome. Main Outcomes and Measures: Early-onset AF (defined as AF onset in persons <66 years of age). Due to multiple testing, the significance threshold for the rare variant analysis was P = 4.55 × 10-3. Results: Among 2781 participants with early-onset AF (the case group), 72.1% were men, and the mean (SD) age of AF onset was 48.7 (10.2) years. Participants underwent whole-genome sequencing at a mean depth of 37.8 fold and mean genome coverage of 99.1%. At least 1 LOF variant in TTN, the gene encoding the sarcomeric protein titin, was present in 2.1% of case participants compared with 1.1% in control participants (odds ratio [OR], 1.76 [95% CI, 1.04-2.97]). The proportion of individuals with early-onset AF who carried a LOF variant in TTN increased with an earlier age of AF onset (P value for trend, 4.92 × 10-4), and 6.5% of individuals with AF onset prior to age 30 carried a TTN LOF variant (OR, 5.94 [95% CI, 2.64-13.35]; P = 1.65 × 10-5). The association between TTN LOF variants and AF was replicated in an independent study of 1582 patients with early-onset AF (cases) and 41 200 control participants (OR, 2.16 [95% CI, 1.19-3.92]; P = .01). Conclusions and Relevance: In a case-control study, there was a statistically significant association between an LOF variant in the TTN gene and early-onset AF, with the variant present in a small percentage of participants with early-onset AF (the case group). Further research is necessary to understand whether this is a causal relationship.


Assuntos
Fibrilação Atrial/genética , Conectina/genética , Mutação com Perda de Função , Adulto , Idade de Início , Estudos de Casos e Controles , Feminino , Predisposição Genética para Doença , Estudo de Associação Genômica Ampla , Heterozigoto , Humanos , Masculino , Pessoa de Meia-Idade , Controle de Qualidade
14.
Genet Med ; 19(11): 1245-1252, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28471438

RESUMO

PurposeArrhythmogenic right ventricular cardiomyopathy (ARVC) is an inherited heart disease. Clinical follow-up of incidental findings in ARVC-associated genes is recommended. We aimed to determine the prevalence of disease thus ascertained.MethodsIndividuals (n = 30,716) underwent exome sequencing. Variants in PKP2, DSG2, DSC2, DSP, JUP, TMEM43, or TGFß3 that were database-listed as pathogenic or likely pathogenic were identified and evidence-reviewed. For subjects with putative loss-of-function (pLOF) variants or variants of uncertain significance (VUS), electronic health records (EHR) were reviewed for ARVC diagnosis, diagnostic criteria, and International Classification of Diseases (ICD-9) codes.ResultsEighteen subjects had pLOF variants; none of these had an EHR diagnosis of ARVC. Of 14 patients with an electrocardiogram, one had a minor diagnostic criterion; the rest were normal. A total of 184 subjects had VUS, none of whom had an ARVC diagnosis. The proportion of subjects with VUS with major (4%) or minor (13%) electrocardiogram diagnostic criteria did not differ from that of variant-negative controls. ICD-9 codes showed no difference in defibrillator use, electrophysiologic abnormalities or nonischemic cardiomyopathies in patients with pLOF or VUSs compared with controls.ConclusionpLOF variants in an unselected cohort were not associated with ARVC phenotypes based on EHR review. The negative predictive value of EHR review remains uncertain.


Assuntos
Displasia Arritmogênica Ventricular Direita/genética , Exoma , Variação Genética , Análise de Sequência de DNA , Adulto , Displasia Arritmogênica Ventricular Direita/epidemiologia , Estudos de Coortes , Registros Eletrônicos de Saúde , Feminino , Estudos de Associação Genética , Genótipo , Humanos , Masculino , Pessoa de Meia-Idade , Fenótipo , Prevalência
15.
J Magn Reson Imaging ; 45(3): 786-794, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27458823

RESUMO

PURPOSE: To determine the optimal respiratory navigator gating configuration for the quantification of left ventricular strain using spiral cine displacement encoding with stimulated echoes (DENSE) MRI. MATERIALS AND METHODS: Two-dimensional spiral cine DENSE was performed on a 3 Tesla MRI using two single-navigator configurations (retrospective, prospective) and a combined "dual-navigator" configuration in 10 healthy adults and 20 healthy children. The adults also underwent breathhold DENSE as a reference standard for comparisons. Peak left ventricular strains, signal-to-noise ratio (SNR), and navigator efficiency were compared. Subjects also underwent dual-navigator gating with and without visual feedback to determine the effect on navigator efficiency. RESULTS: There were no differences in circumferential, radial, and longitudinal strains between navigator-gated and breathhold DENSE (P = 0.09-0.95) (as confidence intervals, retrospective: [-1.0%-1.1%], [-7.4%-2.0%], [-1.0%-1.2%]; prospective: [-0.6%-2.7%], [-2.8%-8.3%], [-0.3%-2.9%]; dual: [-1.6%-0.5%], [-8.3%-3.2%], [-0.8%-1.9%], respectively). The dual configuration maintained SNR compared with breathhold acquisitions (16 versus 18, P = 0.06). SNR for the prospective configuration was lower than for the dual navigator in adults (P = 0.004) and children (P < 0.001). Navigator efficiency was higher (P < 0.001) for both retrospective (54%) and prospective (56%) configurations compared with the dual configuration (35%). Visual feedback improved the dual configuration navigator efficiency to 55% (P < 0.001). CONCLUSION: When quantifying left ventricular strains using spiral cine DENSE MRI, a dual navigator configuration results in the highest SNR in adults and children. In adults, a retrospective configuration has good navigator efficiency without a substantial drop in SNR. Prospective gating should be avoided because it has the lowest SNR. Visual feedback represents an effective option to maintain navigator efficiency while using a dual navigator configuration. LEVEL OF EVIDENCE: 2 J. Magn. Reson. Imaging 2017;45:786-794.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Técnicas de Imagem por Elasticidade/métodos , Ventrículos do Coração/diagnóstico por imagem , Aumento da Imagem/métodos , Imagem Cinética por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Função Ventricular Esquerda/fisiologia , Adolescente , Módulo de Elasticidade/fisiologia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estresse Mecânico , Resistência à Tração/fisiologia , Adulto Jovem
16.
J Cardiovasc Magn Reson ; 19(1): 25, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28245864

RESUMO

BACKGROUND: Left ventricular (LV) torsion is an important indicator of cardiac function that is limited by high inter-test variability (50% of the mean value). We hypothesized that this high inter-test variability is partly due to inconsistent breath-hold positions during serial image acquisitions, which could be significantly improved by using a respiratory navigator for cardiovascular magnetic resonance (CMR) based quantification of LV torsion. METHODS: We assessed respiratory-related variability in measured LV torsion with two distinct experimental protocols. First, 17 volunteers were recruited for CMR with cine displacement encoding with stimulated echoes (DENSE) in which a respiratory navigator was used to measure and then enforce variability in end-expiratory position between all LV basal and apical acquisitions. From these data, we quantified the inter-test variability of torsion in the absence and presence of enforced end-expiratory position variability, which established an upper bound for the expected torsion variability. For the second experiment (in 20 new, healthy volunteers), 10 pairs of cine DENSE basal and apical images were each acquired from consecutive breath-holds and consecutive navigator-gated scans (with a single acceptance position). Inter-test variability of torsion was compared between the breath-hold and navigator-gated scans to quantify the variability due to natural breath-hold variation. To demonstrate the importance of these variability reductions, we quantified the reduction in sample size required to detect a clinically meaningful change in LV torsion with the use of a respiratory navigator. RESULTS: The mean torsion was 3.4 ± 0.2°/cm. From the first experiment, enforced variability in end-expiratory position translated to considerable variability in measured torsion (0.56 ± 0.34°/cm), whereas inter-test variability with consistent end-expiratory position was 57% lower (0.24 ± 0.16°/cm, p < 0.001). From the second experiment, natural respiratory variability from consecutive breath-holds translated to a variability in torsion of 0.24 ± 0.10°/cm, which was significantly higher than the variability from navigator-gated scans (0.18 ± 0.06°/cm, p = 0.02). By using a respiratory navigator with DENSE, theoretical sample sizes were reduced from 66 to 16 and 26 to 15 as calculated from the two experiments. CONCLUSIONS: A substantial portion (22-57%) of the inter-test variability of LV torsion can be reduced by using a respiratory navigator to ensure a consistent breath-hold position between image acquisitions.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Mecânica Respiratória , Técnicas de Imagem de Sincronização Respiratória , Função Ventricular Esquerda , Adulto , Idoso , Fenômenos Biomecânicos , Suspensão da Respiração , Feminino , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo , Torção Mecânica , Adulto Jovem
17.
J Cardiovasc Magn Reson ; 19(1): 100, 2017 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-29228952

RESUMO

BACKGROUND: Patients with repaired tetralogy of Fallot (TOF) have progressive, adverse biventricular remodeling, leading to abnormal contractile mechanics. Defining the mechanisms underlying this dysfunction, such as diffuse myocardial fibrosis, may provide insights into poor long-term outcomes. We hypothesized that left ventricular (LV) diffuse fibrosis is related to impaired LV mechanics. METHODS: Patients with TOF were evaluated with cardiac magnetic resonance in which modified Look-Locker (MOLLI) T1-mapping and spiral cine Displacement encoding (DENSE) sequences were acquired at three LV short-axis positions. Linear mixed modeling was used to define the association between regional LV mechanics from DENSE based on regional T1-derived diffuse fibrosis measures, such as extracellular volume fraction (ECV). RESULTS: Forty patients (26 ± 11 years) were included. LV ECV was generally within normal range (0.24 ± 0.05). For LV mechanics, peak circumferential strains (-15 ± 3%) and dyssynchrony indices (16 ± 8 ms) were moderately impaired, while peak radial strains (29 ± 8%) were generally normal. After adjusting for patient age, sex, and regional LV differences, ECV was associated with log-adjusted LV dyssynchrony index (ß = 0.67) and peak LV radial strain (ß = -0.36), but not LV circumferential strain. Moreover, post-contrast T1 was associated with log-adjusted LV diastolic circumferential strain rate (ß = 0.37). CONCLUSIONS: We observed several moderate associations between measures of fibrosis and impaired mechanics, particularly the LV dyssynchrony index and peak radial strain. Diffuse fibrosis may therefore be a causal factor in some ventricular dysfunction in TOF.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Contração Miocárdica , Miocárdio/patologia , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Esquerda/etiologia , Função Ventricular Esquerda , Remodelação Ventricular , Adolescente , Adulto , Fenômenos Biomecânicos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos Transversais , Feminino , Fibrose , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Fatores de Risco , Tetralogia de Fallot/complicações , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Adulto Jovem
18.
J Cardiovasc Magn Reson ; 19(1): 49, 2017 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-28659144

RESUMO

BACKGROUND: Pediatric obesity is a growing public health problem, which is associated with increased risk of cardiovascular disease and premature death. Left ventricular (LV) remodeling (increased myocardial mass and thickness) and contractile dysfunction (impaired longitudinal strain) have been documented in obese children, but little attention has been paid to the right ventricle (RV). We hypothesized that obese/overweight children would have evidence of RV remodeling and contractile dysfunction. METHODS: One hundred and three children, ages 8-18 years, were prospectively recruited and underwent cardiovascular magnetic resonance (CMR), including both standard cine imaging and displacement encoding with stimulated echoes (DENSE) imaging, which allowed for quantification of RV geometry and function/mechanics. RV free wall longitudinal strain was quantified from the end-systolic four-chamber DENSE image. Linear regression was used to quantify correlations of RV strain with LV strain and measurements of body composition (adjusted for sex and height). Analysis of variance was used to study the relationship between RV strain and LV remodeling types (concentric remodeling, eccentric/concentric hypertrophy). RESULTS: The RV was sufficiently visualized with DENSE in 70 (68%) subjects, comprising 36 healthy weight (13.6 ± 2.7 years) and 34 (12.1 ± 2.9 years) obese/overweight children. Obese/overweight children had a 22% larger RV mass index (8.2 ± 0.9 vs 6.7 ± 1.1 g/m2.7, p < 0.001) compared to healthy controls. RV free wall longitudinal strain was impaired in obese/overweight children (-16 ± 4% vs -19 ± 5%, p = 0.02). Ten (14%) out of 70 children had LV concentric hypertrophy, and these children had the most impaired RV longitudinal strain compared to those with normal LV geometry (-13 ± 4% vs -19 ± 5%, p = 0.002). RV longitudinal strain was correlated with LV longitudinal strain (r = 0.34, p = 0.004), systolic blood pressure (r = 0.33, p = 0.006), as well as BMI z-score (r = 0.28, p = 0.02), waist (r = 0.31, p = 0.01), hip (r = 0.40, p = 0.004) and abdominal (r = 0.38, p = 0.002) circumference, height and sex adjusted. CONCLUSIONS: Obese/overweight children have evidence of RV remodeling (increased RV mass) and RV contractile dysfunction (impaired free wall longitudinal strain). Moreover, RV longitudinal strain correlates with LV longitudinal strain, and children with LV concentric hypertrophy show the most impaired RV function. These results suggest there may be a common mechanism underlying both remodeling and dysfunction of the left and right ventricles in obese/overweight children.


Assuntos
Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Contração Miocárdica , Obesidade Infantil/complicações , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Esquerda , Função Ventricular Direita , Remodelação Ventricular , Adolescente , Criança , Feminino , Humanos , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Interpretação de Imagem Assistida por Computador , Kentucky , Modelos Lineares , Masculino , Variações Dependentes do Observador , Obesidade Infantil/diagnóstico , Obesidade Infantil/fisiopatologia , Pennsylvania , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/fisiopatologia
19.
J Cardiovasc Magn Reson ; 19(1): 86, 2017 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-29117866

RESUMO

BACKGROUND: Children with obesity have hypertrophic cardiac remodeling. Hypertension is common in pediatric obesity, and may independently contribute to hypertrophy. We hypothesized that both the degree of obesity and ambulatory blood pressure (ABP) would independently associate with measures of hypertrophic cardiac remodeling in children. METHODS: Children, aged 8-17 years, prospectively underwent cardiovascular magnetic resonance (CMR) and ABP monitoring. Left ventricular (LV) mass indexed to height2.7 (LVMI), myocardial thickness and end-diastolic volume were quantified from a 3D LV model reconstructed from cine balanced steady state free precession images. Categories of remodeling were determined based on cutoff values for LVMI and mass/volume. Principal component analysis was used to define a "hypertrophy score" to study the continuous relationship between concentric hypertrophy and ABP. RESULTS: Seventy-two children were recruited, and 68 of those (37 healthy weight and 31 obese/overweight) completed both CMR and ABP monitoring. Obese/overweight children had increased LVMI (27 ± 4 vs 22 ± 3 g/m2.7, p < 0.001), myocardial thickness (5.6 ± 0.9 vs 4.9 ± 0.7 mm, p < 0.001), mass/volume (0.69 ± 0.1 vs 0.61 ± 0.06, p < 0.001), and hypertrophy score (1.1 ± 2.2 vs -0.96 ± 1.1, p < 0.001). Thirty-five percent of obese/overweight children had concentric hypertrophy. Ambulatory hypertension was observed in 26% of the obese/overweight children and none of the controls while masked hypertension was observed in 32% of the obese/overweight children and 16% of the controls. Univariate linear regression showed that BMI z-score, systolic BP (24 h, day and night), and systolic load correlated with LVMI, thickness, mass/volume and hypertrophy score, while 24 h and nighttime diastolic BP and load also correlated with thickness and mass/volume. Multivariate analysis showed body mass index z-score and systolic blood pressure were both independently associated with left ventricular mass index (ß=0.54 [p < 0.001] and 0.22 [p = 0.03]), thickness (ß=0.34 [p < 0.001] and 0.26 [p = 0.001]) and hypertrophy score (ß=0.47 and 0.36, both p < 0.001). CONCLUSIONS: In children, both the degree of obesity and ambulatory blood pressures are independently associated with measures of cardiac hypertrophic remodeling, however the correlations were generally stronger for the degree of obesity. This suggests that interventions targeted at weight loss or obesity-associated co-morbidities including hypertension may be effective in reversing or preventing cardiac remodeling in obese children.


Assuntos
Pressão Sanguínea , Hipertensão/etiologia , Hipertrofia Ventricular Esquerda/etiologia , Obesidade Infantil/complicações , Função Ventricular Esquerda , Remodelação Ventricular , Adolescente , Fatores Etários , Monitorização Ambulatorial da Pressão Arterial , Índice de Massa Corporal , Distribuição de Qui-Quadrado , Criança , Estudos Transversais , Feminino , Humanos , Hipertensão/diagnóstico , Hipertensão/fisiopatologia , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/fisiopatologia , Modelos Lineares , Imagem Cinética por Ressonância Magnética , Masculino , Análise Multivariada , Obesidade Infantil/diagnóstico , Obesidade Infantil/fisiopatologia , Análise de Componente Principal , Estudos Prospectivos , Fatores de Risco , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA