1.
Eur Spine J ; 32(7): 2255-2265, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37179256

RESUMO

PURPOSE: To develop a novel 3D printable polyether ether ketone (PEEK)-hydroxyapatite (HA)-magnesium orthosilicate (Mg2SiO4) composite material with enhanced properties for potential use in tumour, osteoporosis and other spinal conditions. We aim to evaluate biocompatibility and imaging compatibility of the material. METHODS: Materials were prepared in three different compositions, namely composite A: 75 weight % PEEK, 20 weight % HA, 5 weight % Mg2SiO4; composite B: 70 weight% PEEK, 25 weight % HA, 5 weight % Mg2SiO4; and composite C: 65 weight % PEEK, 30 weight % HA, 5 weight % Mg2SiO4. The materials were processed to obtain 3D printable filament. Biomechanical properties were analysed as per ASTM standards and biocompatibility of the novel material was evaluated using indirect and direct cell cytotoxicity tests. Cell viability of the novel material was compared to PEEK and PEEK-HA materials. The novel material was used to 3D print a standard spine cage. Furthermore, the CT and MR imaging compatibility of the novel material cage vs PEEK and PEEK-HA cages were evaluated using a phantom setup. RESULTS: Composite A resulted in optimal material processing to obtain a 3D printable filament, while composite B and C resulted in non-optimal processing. Composite A enhanced cell viability up to ~ 20% compared to PEEK and PEEK-HA materials. Composite A cage generated minimal/no artefacts on CT and MR imaging and the images were comparable to that of PEEK and PEEK-HA cages. CONCLUSION: Composite A demonstrated superior bioactivity vs PEEK and PEEK-HA materials and comparable imaging compatibility vs PEEK and PEEK-HA. Therefore, our material displays an excellent potential to manufacture spine implants with enhanced mechanical and bioactive property.


Assuntos
Durapatita , Polietilenoglicóis , Humanos , Durapatita/farmacologia , Polímeros , Cetonas
2.
Eur Spine J ; 32(6): 1953-1965, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37052651

RESUMO

PURPOSE: To manufacture and test 3D printed novel design titanium spine rods with lower flexural modulus and stiffness compared to standard solid titanium rods for use in metastatic spine tumour surgery (MSTS) and osteoporosis. METHODS: Novel design titanium spine rods were designed and 3D printed. Three-point bending test was performed to assess mechanical performance of rods, while a French bender was used to assess intraoperative rod contourability. Furthermore, 3D printed spine rods were tested for CT & MR imaging compatibility using phantom setup. RESULTS: Different spine rod designs generated includes shell, voronoi, gyroid, diamond, weaire-phelan, kelvin, and star. Tests showed 3D printed rods had lower flexural modulus with reduction ranging from 2 to 25% versus standard rod. Shell rods exhibited highest reduction in flexural modulus of 25% (~ 77.4 GPa) and star rod exhibited lowest reduction in flexural modulus of 2% (100.8GPa). 3D printed rod showed reduction in stiffness ranging from 40 to 59%. Shell rod displayed highest reduction in stiffness of 59% (179.9 N/mm) and gyroid had least reduction in stiffness of 40% (~ 259.2 N/mm). Rod bending test showed that except gyroid, other rod designs demonstrated lesser bending difficulty versus standard rod. All 3D printed rods demonstrated improved CT/MR imaging compatibility with reduced artefacts versus standard rod. CONCLUSION: By utilising novel design approach, we successfully generated a spine rod design portfolio with lower flexural modulus/stiffness profile and better CT/MR imaging compatibility for potential use in MSTS/other conditions such as osteoporosis. Thus, exploration of new rod designs in surgical application could enhance treatment outcome and improve quality of life for patients.


Assuntos
Qualidade de Vida , Titânio , Humanos , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia , Impressão Tridimensional , Teste de Materiais
3.
Eur Spine J ; 32(11): 3815-3824, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37093263

RESUMO

PURPOSE: To develop a deep learning (DL) model for epidural spinal cord compression (ESCC) on CT, which will aid earlier ESCC diagnosis for less experienced clinicians. METHODS: We retrospectively collected CT and MRI data from adult patients with suspected ESCC at a tertiary referral institute from 2007 till 2020. A total of 183 patients were used for training/validation of the DL model. A separate test set of 40 patients was used for DL model evaluation and comprised 60 staging CT and matched MRI scans performed with an interval of up to 2 months. DL model performance was compared to eight readers: one musculoskeletal radiologist, two body radiologists, one spine surgeon, and four trainee spine surgeons. Diagnostic performance was evaluated using inter-rater agreement, sensitivity, specificity and AUC. RESULTS: Overall, 3115 axial CT slices were assessed. The DL model showed high kappa of 0.872 for normal, low and high-grade ESCC (trichotomous), which was superior compared to a body radiologist (R4, κ = 0.667) and all four trainee spine surgeons (κ range = 0.625-0.838)(all p < 0.001). In addition, for dichotomous normal versus any grade of ESCC detection, the DL model showed high kappa (κ = 0.879), sensitivity (91.82), specificity (92.01) and AUC (0.919), with the latter AUC superior to all readers (AUC range = 0.732-0.859, all p < 0.001). CONCLUSION: A deep learning model for the objective assessment of ESCC on CT had comparable or superior performance to radiologists and spine surgeons. Earlier diagnosis of ESCC on CT could reduce treatment delays, which are associated with poor outcomes, increased costs, and reduced survival.


Assuntos
Aprendizado Profundo , Compressão da Medula Espinal , Adulto , Humanos , Compressão da Medula Espinal/diagnóstico por imagem , Compressão da Medula Espinal/cirurgia , Estudos Retrospectivos , Coluna Vertebral , Tomografia Computadorizada por Raios X/métodos
4.
Radiology ; 305(1): 160-166, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35699577

RESUMO

Background Lumbar spine MRI studies are widely used for back pain assessment. Interpretation involves grading lumbar spinal stenosis, which is repetitive and time consuming. Deep learning (DL) could provide faster and more consistent interpretation. Purpose To assess the speed and interobserver agreement of radiologists for reporting lumbar spinal stenosis with and without DL assistance. Materials and Methods In this retrospective study, a DL model designed to assist radiologists in the interpretation of spinal canal, lateral recess, and neural foraminal stenoses on lumbar spine MRI scans was used. Randomly selected lumbar spine MRI studies obtained in patients with back pain who were 18 years and older over a 3-year period, from September 2015 to September 2018, were included in an internal test data set. Studies with instrumentation and scoliosis were excluded. Eight radiologists, each with 2-13 years of experience in spine MRI interpretation, reviewed studies with and without DL model assistance with a 1-month washout period. Time to diagnosis (in seconds) and interobserver agreement (using Gwet κ) were assessed for stenosis grading for each radiologist with and without the DL model and compared with test data set labels provided by an external musculoskeletal radiologist (with 32 years of experience) as the reference standard. Results Overall, 444 images in 25 patients (mean age, 51 years ± 20 [SD]; 14 women) were evaluated in a test data set. DL-assisted radiologists had a reduced interpretation time per spine MRI study, from a mean of 124-274 seconds (SD, 25-88 seconds) to 47-71 seconds (SD, 24-29 seconds) (P < .001). DL-assisted radiologists had either superior or equivalent interobserver agreement for all stenosis gradings compared with unassisted radiologists. DL-assisted general and in-training radiologists improved their interobserver agreement for four-class neural foraminal stenosis, with κ values of 0.71 and 0.70 (with DL) versus 0.39 and 0.39 (without DL), respectively (both P < .001). Conclusion Radiologists who were assisted by deep learning for interpretation of lumbar spinal stenosis on MRI scans showed a marked reduction in reporting time and superior or equivalent interobserver agreement for all stenosis gradings compared with radiologists who were unassisted by deep learning. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Hayashi in this issue.


Assuntos
Aprendizado Profundo , Estenose Espinal , Constrição Patológica , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Canal Medular , Estenose Espinal/diagnóstico por imagem
5.
J Digit Imaging ; 35(4): 881-892, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35239091

RESUMO

Large datasets with high-quality labels required to train deep neural networks are challenging to obtain in the radiology domain. This work investigates the effect of training dataset size on the performance of deep learning classifiers, focusing on chest radiograph pneumothorax detection as a proxy visual task in the radiology domain. Two open-source datasets (ChestX-ray14 and CheXpert) comprising 291,454 images were merged and convolutional neural networks trained with stepwise increase in training dataset sizes. Model iterations at each dataset volume were evaluated on an external test set of 525 emergency department chest radiographs. Learning curve analysis was performed to fit the observed AUCs for all models generated. For all three network architectures tested, model AUCs and accuracy increased rapidly from 2 × 103 to 20 × 103 training samples, with more gradual increase until the maximum training dataset size of 291 × 103 images. AUCs for models trained with the maximum tested dataset size of 291 × 103 images were significantly higher than models trained with 20 × 103 images: ResNet-50: AUC20k = 0.86, AUC291k = 0.95, p < 0.001; DenseNet-121 AUC20k = 0.85, AUC291k = 0.93, p < 0.001; EfficientNet AUC20k = 0.92, AUC 291 k = 0.98, p < 0.001. Our study established learning curves describing the relationship between dataset training size and model performance of deep learning convolutional neural networks applied to a typical radiology binary classification task. These curves suggest a point of diminishing performance returns for increasing training data volumes, which algorithm developers should consider given the high costs of obtaining and labelling radiology data.


Assuntos
Aprendizado Profundo , Pneumotórax , Algoritmos , Humanos , Redes Neurais de Computação , Pneumotórax/diagnóstico por imagem , Radiografia
6.
Radiology ; 300(1): 130-138, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33973835

RESUMO

Background Assessment of lumbar spinal stenosis at MRI is repetitive and time consuming. Deep learning (DL) could improve -productivity and the consistency of reporting. Purpose To develop a DL model for automated detection and classification of lumbar central canal, lateral recess, and neural -foraminal stenosis. Materials and Methods In this retrospective study, lumbar spine MRI scans obtained from September 2015 to September 2018 were included. Studies of patients with spinal instrumentation or studies with suboptimal image quality, as well as postgadolinium studies and studies of patients with scoliosis, were excluded. Axial T2-weighted and sagittal T1-weighted images were used. Studies were split into an internal training set (80%), validation set (9%), and test set (11%). Training data were labeled by four radiologists using predefined gradings (normal, mild, moderate, and severe). A two-component DL model was developed. First, a convolutional neural network (CNN) was trained to detect the region of interest (ROI), with a second CNN for classification. An internal test set was labeled by a musculoskeletal radiologist with 31 years of experience (reference standard) and two subspecialist radiologists (radiologist 1: A.M., 5 years of experience; radiologist 2: J.T.P.D.H., 9 years of experience). DL model performance on an external test set was evaluated. Detection recall (in percentage), interrater agreement (Gwet κ), sensitivity, and specificity were calculated. Results Overall, 446 MRI lumbar spine studies were analyzed (446 patients; mean age ± standard deviation, 52 years ± 19; 240 women), with 396 patients in the training (80%) and validation (9%) sets and 50 (11%) in the internal test set. For internal testing, DL model and radiologist central canal recall were greater than 99%, with reduced neural foramina recall for the DL model (84.5%) and radiologist 1 (83.9%) compared with radiologist 2 (97.1%) (P < .001). For internal testing, dichotomous classification (normal or mild vs moderate or severe) showed almost-perfect agreement for both radiologists and the DL model, with respective κ values of 0.98, 0.98, and 0.96 for the central canal; 0.92, 0.95, and 0.92 for lateral recesses; and 0.94, 0.95, and 0.89 for neural foramina (P < .001). External testing with 100 MRI scans of lumbar spines showed almost perfect agreement for the DL model for dichotomous classification of all ROIs (κ, 0.95-0.96; P < .001). Conclusion A deep learning model showed comparable agreement with subspecialist radiologists for detection and classification of central canal and lateral recess stenosis, with slightly lower agreement for neural foraminal stenosis at lumbar spine MRI. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Hayashi in this issue.


Assuntos
Aprendizado Profundo , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Estenose Espinal/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
7.
Radiographics ; 40(4): 1107-1124, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32412828

RESUMO

The first metatarsophalangeal joint (MTPJ) is vital to the biomechanics of the foot and supports a weight up to eight times heavier than the body during athletic activities. The first MTPJ comprises osseous and cartilaginous surfaces along with a complex of supporting structures, including the dorsal extensor tendons, collateral ligaments, and a plantar plate complex. In contradistinction to the lesser MTPJ plantar plates, a single dominant fibrocartilaginous capsular thickening does not exist at the first MTPJ. Instead, the plantar plate complex comprises a fibrocartilaginous pad that invests the hallux sesamoids and is inseparable from the plantar capsule, the intersesamoid ligament, paired metatarsosesamoid and sesamoid phalangeal ligaments (SPLs), and the musculotendinous structures. Acute injury at the first MTPJ is typically secondary to forced hyperextension-turf toe-and can involve multiple structures. During hyperextension, the resulting forces primarily load the distal SPLs, making these structures more susceptible to injury. SPL injuries are best seen in the sagittal plane at MRI. Radiography can also aid in diagnosis of full-thickness SPL tears, demonstrating reduced sesamoid excursion at lateral dorsiflexed (stress) views. Hallux valgus is another common condition, resulting in progressive disabling deformity at the first MTPJ. Without appropriate treatment, first MTPJ injuries may progress to degenerative hallux rigidus. The authors detail the anatomy of the first MTPJ in cadaveric forefeet by using high-resolution 3-T and 11.7-T MRI and anatomic-pathologic correlation. Injuries to the plantar plate complex, collateral ligaments, and extensor mechanism are discussed using clinical case examples. Online supplemental material is available for this article. ©RSNA, 2020.


Assuntos
Instabilidade Articular/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Articulação Metatarsofalângica/diagnóstico por imagem , Articulação Metatarsofalângica/lesões , Pontos de Referência Anatômicos , Fenômenos Biomecânicos , Cadáver , Humanos , Articulação Metatarsofalângica/anatomia & histologia
8.
BMC Infect Dis ; 19(1): 83, 2019 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-30678651

RESUMO

BACKGROUND: The understanding of early events following TB exposure is limited by traditional tests that rely on detection of an immune response to infection, which is delayed, or on imaging tests with low sensitivity for early disease. We investigated for evidence of lung abnormalities in heavily exposed TB contacts using PET/MRI. METHODS: 30 household contacts of 20 index patients underwent clinical assessment, IGRA testing, chest x-ray and PET/MRI scan using 18-F-FDG. MRI images were examined by a radiology/nuclear medicine dual-qualified physician using a standardised report form, while PET/MRI images were examined independently by another radiology/nuclear medicine dual-qualified physician using a similar form. Standardised uptake value (SUV) was quantified for each abnormal lesion. RESULTS: IGRA was positive in 40%. PET/MRI scan was abnormal in 30%, predominantly FDG uptake in hilar or mediastinal lymph nodes and lung apices. We did not identify any relationship between PET/MRI findings and degree of exposure or IGRA status. CONCLUSION: PET-based imaging may provide important insights into the natural history following exposure to TB that may not be available from traditional tests of TB immune response or imaging. The clinical significance of the abnormalities is uncertain and merits further investigation in longitudinal studies.


Assuntos
Tuberculose Pulmonar/diagnóstico por imagem , Adulto , Idoso , Busca de Comunicante , Características da Família , Feminino , Fluordesoxiglucose F18/administração & dosagem , Humanos , Linfonodos/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/administração & dosagem , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/transmissão , Adulto Jovem
9.
Skeletal Radiol ; 48(3): 467-473, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30151632

RESUMO

Luxatio erecta humeri (LEH), also known as inferior shoulder dislocation, is uncommon, comprising about 0.5% of all cases of shoulder dislocation. Synchronous bilateral LEH is exceedingly rare and, to our knowledge, there are no descriptions of axillary nerve injury on magnetic resonance imaging (MRI) following LEH. We present a case of traumatic bilateral LEH in a 59-year-old woman who fell from a fast-moving mobility scooter and sustained direct axial loading forces on the fully abducted shoulders. Both shoulders were successfully reduced using the traction-countertraction technique in the emergency department. In this article, we describe the characteristic features of LEH on plain radiography and the pattern of acute soft-tissue injuries on MRI. We emphasize the importance of reviewing the axillary neurovascular bundle, which by virtue of its location beneath the shoulder joint, is prone to injury in inferior shoulder dislocation and thus has a substantial impact on functional recovery. This important complication is unfortunately not routinely examined by radiologists, partly because of the paucity of literature highlighting its clinical significance.


Assuntos
Luxações Articulares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Luxação do Ombro/diagnóstico por imagem , Acidentes por Quedas , Feminino , Humanos , Luxações Articulares/etiologia , Luxações Articulares/terapia , Pessoa de Meia-Idade , Luxação do Ombro/etiologia , Luxação do Ombro/terapia
10.
Skeletal Radiol ; 48(9): 1329-1344, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30770941

RESUMO

This article will review the anatomy and common pathologies affecting the peroneus longus muscle and tendon. The anatomy of the peroneus longus is complex and its long course can result in symptomatology referable to the lower leg, ankle, hindfoot, and plantar foot. Proximally, the peroneus longus muscle lies within the lateral compartment of the lower leg with its distal myotendinous junction arising just above the level of the ankle. The distal peroneus longus tendon has a long course and makes two sharp turns at the lateral ankle and hindfoot before inserting at the medial plantar foot. A spectrum of pathology can occur in these regions. At the lower leg, peroneus longus muscle injuries (e.g., denervation) along with retromalleolar tendon instability/subluxation will be discussed. More distally, along the lateral calcaneus and cuboid tunnel, peroneus longus tendinosis and tears, tenosynovitis, and painful os peroneum syndrome (POPS) will be covered. Pathology of the peroneus longus will be illustrated using clinical case examples along its entire length; these will help the radiologist understand and interpret common peroneus longus disorders.


Assuntos
Diagnóstico por Imagem/métodos , Extremidade Inferior/patologia , Doenças Musculares/diagnóstico por imagem , Doenças Musculares/patologia , Traumatismos dos Tendões/diagnóstico por imagem , Traumatismos dos Tendões/patologia , Tornozelo/diagnóstico por imagem , Tornozelo/patologia , Pé/diagnóstico por imagem , Pé/patologia , Humanos , Extremidade Inferior/diagnóstico por imagem , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/patologia , Tendões/diagnóstico por imagem , Tendões/patologia
12.
Eur Radiol ; 26(2): 398-406, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26032879

RESUMO

OBJECTIVES: Comparison of magnetic resonance elastography (MRE) and diffusion-weighted imaging (DWI) for differentiating malignant and benign focal liver lesions (FLLs). METHODS: Seventy-nine subjects with 124 FLLs (44 benign and 80 malignant) underwent both MRE and DWI. MRE was performed with a modified gradient-echo sequence and DWI with a free breathing technique (b = 0.500). Apparent diffusion coefficient (ADC) maps and stiffness maps were generated. FLL mean stiffness and ADC values were obtained by placing regions of interest over the FLLs on stiffness and ADC maps. The accuracy of MRE and DWI for differentiation of benign and malignant FLL was compared using receiver operating curve (ROC) analysis. RESULTS: There was a significant negative correlation between stiffness and ADC (r = -0.54, p < 0.0001) of FLLs. Malignant FLLs had significantly higher mean stiffness (7.9kPa vs. 3.1kPa, p < 0.001) and lower mean ADC (129 vs. 200 × 10(-3)mm(2)/s, p < 0.001) than benign FLLs. The sensitivity/specificity/positive predictive value/negative predictive value for differentiating malignant from benign FLLs with MRE (cut-off, >4.54kPa) and DWI (cut-off, <151 × 10(-3)mm(2)/s) were 96.3/95.5/97.5/93.3% (p < 0.001) and 85/81.8/88.3/75% (p < 0.001), respectively. ROC analysis showed significantly higher accuracy for MRE than DWI (0.986 vs. 0.82, p = 0.0016). CONCLUSION: MRE is significantly more accurate than DWI for differentiating benign and malignant FLLs. KEY POINTS: • MRE is superior to DWI for differentiating benign and malignant focal liver lesions. • Benign lesions with large fibrous components may have higher stiffness with MRE. • Cholangiocarcinomas tend to have higher stiffness than hepatocellular carcinomas. • Hepatocellular adenomas tend to have lower stiffness than focal nodular hyperplasia. • MRE is superior to conventional MRI in differentiating benign and malignant liver lesions.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Fígado/patologia , Masculino , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
17.
Abdom Imaging ; 40(4): 783-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25331568

RESUMO

PURPOSE: To evaluate the effect of intravenous gadolinium-diethylenetriamine penta-acetic acid (Gd-DTPA) on estimation of liver stiffness using magnetic resonance elastography (MRE) for detection of liver fibrosis. MATERIALS AND METHODS: Liver MRI with MRE was performed in 210 subjects on a single 1.5 Tesla clinical MRI scanner. Liver MRE was performed before intravenous Gd-DTPA injection (NC-MRE) and 5 minutes post injection (PC-MRE) using a modified phase-contrast gradient-echo sequence (TR/TE=100/27 ms, FOV = 30-46 cm, 4 x 10 mm slices, gap 5 mm) which automatically generated stiffness maps. Two readers' blinded to clinical details independently performed liver stiffness measurements (LSM) by drawing 2 or more regions of interest (ROI) on the stiffness maps on each of the four slices of NC-MRE and PC-MRE obtained for each patient. The mean LSM in kilopascals (kPa) for NC-MRE and PC-MRE was calculated. The correlation between NC-MRE and PC-MRE LSM was evaluated with a paired t test and Pearson's correlation analysis, and the inter-observer correlation was evaluated using intra class coefficient (ICC) analysis. A receiver operating curve analysis (ROC) was performed to compare accuracies for detection and staging of liver fibrosis in a subgroup of 72 subjects with histological confirmation of liver fibrosis. RESULTS: There was an excellent correlation between NC-MRE and PC-MRE LSM (R(2)=0.98, p<0.001) with no significant differences. The interobserver agreement was also excellent (ICC, 0.94-0.99). There were no significant differences in the cut-off LSM value/accuracy/sensitivity/specificity for detection of significant liver fibrosis with NC-MRE and PC-MRE (2.98 kPa/98.5%/100%/88%, p<0.001 and 3.1 kPa/98.2%/98%/88%, p<0.001 respectively). CONCLUSION: Intravenous Gd-DTPA had no significant influence on LSM with MRE and does not significantly affect the diagnostic performance of MRE for fibrosis detection.


Assuntos
Meios de Contraste/administração & dosagem , Técnicas de Imagem por Elasticidade , Gadolínio DTPA/administração & dosagem , Aumento da Imagem/métodos , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética , Administração Intravenosa , Feminino , Humanos , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade