Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Interv Cardiol ; 2022: 9915247, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35360094

RESUMO

Background: The impact of devices for vessel closure on the safety and efficacy of cannula removal in VA-ECMO patients is unknown. Methods: We retrospectively analyzed 180 consecutive patients weaned from VA-ECMO after cardiac arrest or cardiogenic shock from January 2012 to June 2020. In the first period (historical technique group), from January 2012 to December 2018, primary decannulation strategy was manual compression. In the second period (current technique group), from January 2019 to June 2020, decannulation was performed either by a conventional approach with manual compression or by a suture-mediated closure device technique. Results: A femoral compression system was necessary in 71% of patients in the historical group compared to 39% in the current technique group (p < 0.01). Vascular surgery was performed in 12% in the historical cohort and 2% in the current technique cohort, which indicated a clear trend, albeit it did not reach significance (p = 0.07). Conclusion: We illustrated that a suture-mediated closure device technique for VA-ECMO decannulation was feasible, safe, and may have reduced the need of surgical interventions compared to manual compression alone.


Assuntos
Oxigenação por Membrana Extracorpórea , Oxigenação por Membrana Extracorpórea/métodos , Artéria Femoral/cirurgia , Humanos , Estudos Retrospectivos , Técnicas de Sutura , Suturas
2.
J Clin Med ; 13(8)2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38673527

RESUMO

Background: Extracorporeal life support (ECLS) therapy for refractory postcardiotomy cardiogenic shock (rPCS) is associated with high early mortality rates. This study aimed to identify negative predictors of mid-term survival and to assess health-related quality of life (HRQoL) and recovery of the survivors. Methods: Between 2017 and 2020, 142 consecutive patients received ECLS therapy following cardiac surgery. The median age was 66.0 [57.0-73.0] years, 67.6% were male and the median EuroSCORE II was 10.5% [4.2-21.3]. In 48 patients, HRQoL was examined using the 36-Item Short Form Survey (SF-36) and the modified Rankin-Scale (mRS) at a median follow-up time of 2.2 [1.9-3.2] years. Results: Estimated survival rates at 3, 12, 24 and 36 months were 47%, 46%, 43% and 43% (SE: 4%). Multivariable Cox Proportional Hazard regression analysis revealed preoperative EuroSCORE II (p = 0.013), impaired renal function (p = 0.010), cardiopulmonary bypass duration (p = 0.015) and pre-ECLS lactate levels (p = 0.004) as independent predictors of mid-term mortality. At the time of follow-up, 83.3% of the survivors were free of moderate to severe disability (mRS < 3). SF-36 analysis showed a physical component summary of 45.5 ± 10.2 and a mental component summary of 50.6 ± 12.5. Conclusions: Considering the disease to be treated, ECLS for rPCS is associated with acceptable mid-term survival, health-related quality of life and functional status. Preoperative EuroSCORE II, impaired renal function, cardiopulmonary bypass duration and lactate levels prior to ECLS implantation were identified as negative predictors and should be included in the decision-making process.

3.
ASAIO J ; 69(1): e46-e48, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-35471649

RESUMO

Isolated right ventricular failure presents a rare pathology and heart transplantation remains the treatment of choice. Because of the shortage of donor organs, alternative treatment options are required. However, current continuous-flow ventricular assist devices are designed and approved only for left ventricular support and right ventricular implantation usually presents a procedure of last resort. Herein, we present a successful implantation of the HeartMate 3 for isolated right ventricular support as destination therapy in a patient suffering from late-onset arrhythmogenic right ventricular cardiomyopathy.


Assuntos
Displasia Arritmogênica Ventricular Direita , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/cirurgia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Transplante de Coração/efeitos adversos , Ventrículos do Coração/cirurgia
4.
Front Cardiovasc Med ; 10: 1198204, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37363098

RESUMO

Chronic thromboembolic pulmonary hypertension is a rare but life-threatening complication of long-term central venous catheters (CVC) in children. However, evidence in terms of potential treatment strategies and outcome data remains scarce. We describe two cases of CVC-related thrombosis (Hickman-catheter) complicated by recurrent pulmonary emboli. One patient experienced a complete thromboembolic obstruction of the right pulmonary artery with normal pulmonary pressures and the second patient suffered from a central thromboembolic obstruction of both pulmonary arteries associated with severe pulmonary hypertension. Both patients successfully underwent surgical thromboendarterectomy with deep hypothermic circulatory arrest.

5.
Front Cardiovasc Med ; 9: 1070314, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36741835

RESUMO

Ventricular assist device implantation presents a possible bridge to heart transplantation for patients with failing Fontan physiology. However, evidence regarding outcome and possible pitfalls associated with the Fontan circulation is still insufficient. We describe the course of a 13-year-old male, who was born with hypoplastic left heart syndrome and underwent HeartMate III implantation due to refractory failure of the systemic right ventricle.

6.
Artigo em Inglês | MEDLINE | ID: mdl-36562497

RESUMO

BACKGROUND: The HeartMate 3 (HM 3; Abbott) left ventricular assist device (LVAD) has improved hemocompatibility-related adverse outcomes. In sporadic cases, external compression of the outflow graft causing obstruction (eOGO) can result from substance accumulation between the outflow graft and its bend relief. We sought to evaluate the prevalence, course, and clinical implications of eOGO in an international study. METHODS: A multicenter retrospective analysis of HM 3 LVADs implanted between November 2014 and April 2021 (n = 2108) was conducted across 17 cardiac centers in 8 countries. We defined eOGO as obstruction >25% in the cross-sectional area in imaging (percutaneous angiography, computed tomography, or intravascular ultrasound). The prevalence and annual incidence were calculated. Serious adverse events and outcomes (death, transplantation, or device exchange) were analyzed for eOGO cases. RESULTS: Of 2108 patients, 62 were diagnosed with eOGO at a median LVAD support duration of 953 (interquartile range, 600-1267) days. The prevalence of eOGO was 3.0% and the incidence at 1, 2, 3, 4, and 5 years of support was 0.6%, 2.8%, 4.0%, 5.2%, and 9.1%, respectively. Of 62 patients, 9 were observed, 27 underwent surgical revision, 15 underwent percutaneous stent implantation, 8 received a heart transplant, and 2 died before intervention. One patient underwent surgical revision and later stent implantation. The mortality with therapeutic intervention was 9/53 (17.0%). CONCLUSIONS: Although uncommon, HM 3 LVAD-supported patients might develop eOGO with an increasing incidence after 1 year of support. Although engineering efforts to reduce this complication are under way, clinicians must maintain a focus on early detection and remain vigilant.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA