Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Phys Med ; 75: 69-76, 2020 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-32540648

RESUMO

PURPOSE: Titanium dioxide nanoparticles (TiO2 NPs) have been investigated for their role as radiosensitisers for radiation therapy. The study aims to increase the efficiency of these NPs by synthesising them with samarium. METHODS: Samarium-doped TiO2 NPs (Ti(Sm)O2 NPs) were synthesised using a solvothermal method. Transmission electron microscopy (TEM), X-ray diffraction (XRD), and energy-dispersive X-ray spectroscopy (EDS) were performed for characterising of the Ti(Sm)O2 NPs. The intracellular uptake and cytotoxicity were assessed in vitro using A549 and DU145 cancer cell lines. Furthermore, the effect of dose enhancement and generation of reactive oxygen species (ROS) in response to 6 MV X-rays was evaluated. Additionally, the image contrast properties were investigated using computed tomography (CT) images. RESULTS: The synthesised Ti(Sm)O2 NPs were about 13 nm in diameter as determined by TEM. The XRD pattern of Ti(Sm)O2 NPs was consistent with that of anatase-type TiO2. EDS confirmed the presence of samarium in the nanoparticles. At 200 µg/ml concentration, no differences in cellular uptake and cytotoxicity were observed between TiO2 NPs and Ti(Sm)O2 NPs in both A549 and DU145 cells. However, the combination of Ti(Sm)O2 NPs and X-rays elicited higher cytotoxic effect and ROS generation in the cells than that with TiO2 NPs and X-rays. The CT numbers of Ti(Sm)O2 NPs were systematically higher than that of TiO2 NPs. CONCLUSIONS: The Ti(Sm)O2 NPs increased the dose enhancement of MV X-ray beams than that elicited by TiO2 NPs. Samarium improved the efficiency of TiO2 NPs as potential radiosensitising agent.

2.
Phys Med Biol ; 60(2): 883-904, 2015 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-25565406

RESUMO

The Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) has established a method for ionisation chamber calibrations using megavoltage photon reference beams. The new method will reduce the calibration uncertainty compared to a (60)Co calibration combined with the TRS-398 energy correction factor. The calibration method employs a graphite calorimeter and a Monte Carlo (MC) conversion factor to convert the absolute dose to graphite to absorbed dose to water. EGSnrc is used to model the linac head and doses in the calorimeter and water phantom. The linac model is validated by comparing measured and modelled PDDs and profiles. The relative standard uncertainties in the calibration factors at the ARPANSA beam qualities were found to be 0.47% at 6 MV, 0.51% at 10 MV and 0.46% for the 18 MV beam. A comparison with the Bureau International des Poids et Mesures (BIPM) as part of the key comparison BIPM.RI(I)-K6 gave results of 0.9965(55), 0.9924(60) and 0.9932(59) for the 6, 10 and 18 MV beams, respectively, with all beams within 1σ of the participant average. The measured kQ values for an NE2571 Farmer chamber were found to be lower than those in TRS-398 but are consistent with published measured and modelled values. Users can expect a shift in the calibration factor at user energies of an NE2571 chamber between 0.4-1.1% across the range of calibration energies compared to the current calibration method.


Assuntos
Calibragem , Grafite/efeitos da radiação , Método de Monte Carlo , Fótons , Água/química , Austrália , Calorimetria , Grafite/química , Humanos , Aceleradores de Partículas , Imagens de Fantasmas , Doses de Radiação , Radiometria/métodos , Estudos de Validação como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA