1.
J Biomech Eng ; 143(11)2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34114605

RESUMO

Biomechanical testing of long bones can be susceptible to errors and uncertainty due to malalignment of specimens with respect to the mechanical axis of the test frame. To solve this problem, we designed a novel, customizable alignment and potting fixture for long bone testing. The fixture consists of three-dimensional-printed components modeled from specimen-specific computed tomography (CT) scans to achieve a predetermined specimen alignment. We demonstrated the functionality of this fixture by comparing benchtop torsional test results to specimen-matched finite element models and found a strong correlation (R2 = 0.95, p < 0.001). Additional computational models were used to estimate the impact of malalignment on mechanical behavior in both torsion and axial compression. Results confirmed that torsion testing is relatively robust to alignment artifacts, with absolute percent errors less than 8% in all malalignment scenarios. In contrast, axial testing was highly sensitive to setup errors, experiencing absolute percent errors up to 50% with off-center malalignment and up to 170% with angular malalignment. This suggests that whenever appropriate, torsion tests should be used preferentially as a summary mechanical measure. When more challenging modes of loading are required, pretest clinical-resolution CT scanning can be effectively used to create potting fixtures that allow for precise preplanned specimen alignment. This may be particularly important for more sensitive biomechanical tests (e.g., axial compressive tests) that may be needed for industrial applications, such as orthopedic implant design.


Assuntos
Rádio (Anatomia)
2.
BMC Musculoskelet Disord ; 22(1): 468, 2021 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-34022860

RESUMO

BACKGROUND: Failure of surgical fixation in orthopaedic fractures occurs at a significantly higher rate in osteoporotic patients due to weakened osteoporotic bone. A therapy to acutely improve the mechanical properties of bone during fracture repair would have profound clinical impact. A previous study has demonstrated an increase in mechanical properties of acellular cortical canine bone after immersion in raloxifene. The goal of this study was to determine if similar treatment yields the same results in cancellous fetal bovine bone and whether this translates into a difference in screw pull-out strength in human cadaveric tissue. METHODS: Cancellous bone from fetal bovine distal femora underwent quasi-static four-point bending tests after being immersed in either raloxifene (20 µM) or phosphate-buffered saline as a control for 7 days (n = 10). Separately, 5 matched pairs of human osteoporotic cadaveric humeral heads underwent the same procedure. Five 3.5 mm unicortical cancellous screws were then inserted at standard surgical fixation locations to a depth of 30 mm and quasi-static screw pull-out tests were performed. RESULTS: In the four-point bending tests, there were no significant differences between the raloxifene and control groups for any of the mechanical properties - including stiffness (p = 0.333) and toughness (p = 0.546). In the screw pull-out tests, the raloxifene soaked samples and control samples had pullout strengths of 122 ± 74.3 N and 89.5 ± 63.8 N, respectively. CONCLUSIONS: Results from this study indicate that cancellous fetal bovine samples did not demonstrate an increase in toughness with raloxifene treatment, which is in contrast to previously published data that studied canine cortical bone. In vivo experiments are likely required to determine whether raloxifene will improve implant fixation.


Assuntos
Imersão , Cloridrato de Raloxifeno , Animais , Fenômenos Biomecânicos , Parafusos Ósseos , Cadáver , Bovinos , Cães , Humanos , Teste de Materiais , Cloridrato de Raloxifeno/farmacologia
3.
J Hand Surg Am ; 46(2): 106-113, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32950317

RESUMO

PURPOSE: This study examined the effect of low-profile volar rim plates (VR), proximally placed standard variable-angle locking plates (pVA-LCP), and distally placed standard variable-angle locking plates (dVA-LCP) on the flexor pollicis longus (FPL) tendon in a cadaver model. We hypothesized that tendons from the VR and pVA-LCP groups would exhibit similar contact pressures, wear patterns, and post-fatigue testing mechanical properties, whereas dVA-LCP tendons would exhibit higher contact pressures, increased tendon wear patterns, and decreased mechanical properties. METHODS: Nine matched pairs of cadaveric specimens were used in this study. Thin-film pressure sensors were used to measure the initial contact loads between plates and FPL tendons. Specimens were cyclically loaded for 10,000 cycles by actuating the FPL tendon. Cycled tendons were harvested, photographed with a stereomicroscope, and graded for wear on a Likert scale by 5 observers who were blinded to the study protocol. Uniaxial tensile testing measured mechanical properties of the tendon: ultimate failure load, ultimate stress, percent stress relaxation, elastic modulus, and stiffness. RESULTS: With regard to the cadaveric FPL tendon, VR and dVA-LCP had increased contact pressure and tendon wear compared with pVA-LCP. There were no significant differences in contact pressure or tendon wear between dVA-LCP and VR. There was no major difference in the tested mechanical properties of the FPL tendon among any of the groups. CONCLUSIONS: Plates placed directly on or beyond the volar rim demonstrate increased contact pressures and increased tendon wear in a cadaveric model. CLINICAL RELEVANCE: Although low-profile plates allow for fixation of smaller volar fragments in the distal radius, they cause substantial contact with the FPL tendon, which may rupture if the plate is not removed.


Assuntos
Fraturas do Rádio , Traumatismos dos Tendões , Placas Ósseas , Cadáver , Fixação Interna de Fraturas , Humanos , Traumatismos dos Tendões/cirurgia , Tendões/cirurgia
4.
Foot Ankle Surg ; 27(4): 405-411, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32553424

RESUMO

BACKGROUND: This study compared stiffness between two constructs for talonavicular arthrodesis: a dorsomedial plating system and two partially threaded cannulated cancellous screws. We hypothesized that the plate would exhibit greater stiffness and resistance to deformation during cyclic loading. METHODS: The constructs were implanted in eight matched pairs of cadaveric feet and subjected to axial torsion, cantilever bending in two directions, and cyclic loading to failure. RESULTS: The two-screw constructs were significantly stiffer in plantar-dorsal bending (p = .025) and trended towards a higher number of cycles before failure than the plate group (p = .087). No significant differences were observed in internal torsion (p = .620), external torsion (p = .165), or medial-lateral bending (p = .686). CONCLUSIONS: This study provided the first biomechanical assessment of a plating system with an integrated compression screw, which was significantly less stiff than a two-screw construct when loaded from plantar to dorsal.


Assuntos
Artrodese/instrumentação , Artrodese/métodos , Placas Ósseas , Parafusos Ósseos , Pé/cirurgia , Adulto , Idoso , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pressão , Resultado do Tratamento
5.
J Biomech Eng ; 142(8)2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-31913444

RESUMO

Internal fixation with the use of locking plates is the standard surgical treatment for proximal humerus fractures, one of the most common fractures in the elderly. Screw cut-out through weak cancellous bone of the humeral head, which ultimately results in collapse of the fixed fracture, is the leading cause of failure and revision surgery. In an attempt to address this problem, surgeons often attach the plate with as many locking screws as possible into the proximal fragment. It is not thoroughly understood which screws and screw combinations play the most critical roles in fixation stability. This study conducted a detailed finite element analysis to evaluate critical parameters associated with screw cut-out failure. Several clinically relevant screw configurations and fracture gap sizes were modeled. Findings demonstrate that in perfectly reduced fracture cases, variation of the screw configurations had minor influence on mechanical stability of the fixation. The effects of screw configurations became substantial with the existence of a fracture gap. Interestingly, the use of a single anterior calcar screw was as effective as utilizing two screws to support the calcar. On the other hand, the variation in calcar screw configuration had minor influence on the fixation stability when all the proximal screws (A-D level) were filled. This study evaluates different screw configurations to further understand the influence of combined screw configurations and the individual screws on the fixation stability. Findings from this study may help decrease the risk for screw cut-out with proximal humerus varus collapse and the associated economic costs.


Assuntos
Análise de Elementos Finitos , Fraturas do Ombro , Idoso , Fenômenos Biomecânicos , Placas Ósseas , Fixação Interna de Fraturas , Humanos
6.
J Shoulder Elbow Surg ; 28(6): 1183-1192, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30770316

RESUMO

BACKGROUND: Locked plating of displaced proximal humeral fractures is common, but rates of subacromial impingement remain high. This study used a multidisciplinary approach to elucidate the relationships between common surgical parameters, anatomic variability, and the likelihood of plate impingement. METHODS: The experiment was completed in 3 phases. First, a controlled in vitro experiment was conducted to simulate impingement. Second, a dynamic in silico musculoskeletal model modeled changes to implant geometry, surgical techniques, and acromial anatomy, where a collision detection algorithm was used to simulate impingement. Finally, in vivo shoulder kinematics were recorded for 9 activities of daily living. Motions that created a high likelihood of impingement were identified. RESULTS: Of simulated impingement events, 73.9% occurred when the plate was moved proximally, and 84% occurred when acromial tilt was 20° or 25°. Simulations of impingement occurred at cross-body adduction angles between 10° and 50°. Impingement occurred at an average of 162.0° ± 14.8° abduction with 10 mm distal plate placement, whereas the average was 72.1° ± 11.4° with 10 mm proximal placement. A patient may encounter these shoulder angles when performing activities such as combing one's hair, lifting an object overhead, and reaching behind one's head. DISCUSSION AND CONCLUSION: Proximal implant placement and decreases in acromial tilt play major roles in the likelihood of impingement, whereas plate thickness and humeral head center of rotation should also be considered. Careful preoperative planning that includes these factors could help guide operative decision making and improve clinical outcomes.


Assuntos
Placas Ósseas/efeitos adversos , Fixação Interna de Fraturas/instrumentação , Fraturas do Ombro/cirurgia , Síndrome de Colisão do Ombro/etiologia , Acrômio/anatomia & histologia , Atividades Cotidianas , Idoso , Fenômenos Biomecânicos , Cadáver , Simulação por Computador , Feminino , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Humanos , Cabeça do Úmero , Masculino , Movimento , Rotação , Articulação do Ombro/fisiopatologia , Articulação do Ombro/cirurgia , Adulto Jovem
7.
Clin Biomech (Bristol, Avon) ; 111: 106151, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37989063

RESUMO

BACKGROUND: Design freedom offered by additive manufacturing allows for the implementation of functional gradients - where mechanical stiffness is decreased along the length of the implant. It is unclear if such changes will influence failure mechanisms in the context of rib fracture repair. We hypothesized that our novel functionally graded rib implants would be less stiff than controls and decrease occurrence of secondary fracture at implant ends. METHODS: Five novel additively manufactured rib implants were tested along with a clinically used Control implant. Fracture reconstructions were modeled with custom synthetic rib bones with a transverse B1 fracture. Ribs were compressed in a cyclic two-point bend test for 360,000 cycles followed by a ramp to failure test. Differences in cyclic stiffness, 3D interfragmentary motions, ramp-to-failure stiffness, maximum load, and work to failure were determined. FINDINGS: The Control group had lower construct stiffness (0.76 ± 0.28 N/mm), compared to all novel implant designs (means: 1.35-1.61 N/mm, p < 0.05) and rotated significantly more about the bending axis (2.7° ± 1.3°) than the additively manufactured groups (means between 1.2° - 1.6°, p < 0.05). All constructs failed via bone fracture at the most posterior screw hole. Experimental implants were stiffer than Controls, and there were few significant differences between functional gradient groups. INTERPRETATION: Additively manufactured, functionally graded designs have the potential to change the form and function of trauma implants. Here, the impact of functional gradients was limited because implants had small cross-sectional areas.


Assuntos
Fraturas das Costelas , Humanos , Fraturas das Costelas/cirurgia , Placas Ósseas , Fixação de Fratura , Parafusos Ósseos , Fenômenos Biomecânicos , Costelas , Impressão Tridimensional , Fixação Interna de Fraturas
8.
J Orthop Res ; 42(7): 1409-1419, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38368531

RESUMO

Mucopolysaccharidosis (MPS) I is a lysosomal storage disorder characterized by deficient alpha-l-iduronidase activity, leading to abnormal accumulation of glycosaminoglycans (GAGs) in cells and tissues. Synovial joint disease is prevalent and significantly reduces patient quality of life. There is a strong clinical need for improved treatment approaches that specifically target joint tissues; however, their development is hampered by poor understanding of underlying disease pathophysiology, including how pathological changes to component tissues contribute to overall joint dysfunction. Ligaments and tendons, in particular, have received very little attention, despite the critical roles of these tissues in joint stability and biomechanical function. The goal of this study was to leverage the naturally canine model to undertake functional and structural assessments of the anterior (cranial) cruciate ligament (CCL) and Achilles tendon in MPS I. Tissues were obtained postmortem from 12-month-old MPS I and control dogs and tested to failure in uniaxial tension. Both CCLs and Achilles tendons from MPS I animals exhibited significantly lower stiffness and failure properties compared to those from healthy controls. Histological examination revealed multiple pathological abnormalities, including collagen fiber disorganization, increased cellularity and vascularity, and elevated GAG content in both tissues. Clinically, animals exhibited mobility deficits, including abnormal gait, which was associated with hyperextensibility of the stifle and hock joints. These findings demonstrate that pathological changes to both ligaments and tendons contribute to abnormal joint function in MPS I, and suggest that effective clinical management of joint disease in patients should incorporate treatments targeting these tissues.


Assuntos
Tendão do Calcâneo , Modelos Animais de Doenças , Mucopolissacaridose I , Animais , Cães , Mucopolissacaridose I/patologia , Mucopolissacaridose I/fisiopatologia , Tendão do Calcâneo/patologia , Tendão do Calcâneo/fisiopatologia , Fenômenos Biomecânicos , Ligamento Cruzado Anterior/patologia , Masculino , Feminino
9.
J Mech Behav Biomed Mater ; 153: 106457, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38401185

RESUMO

Controlled degradation of biodegradable poly-lactic-co-glycolic acid (PLGA) trauma implants may increase interfragmentary loading which is known to accelerate fracture healing. Additive manufacturing allows us to tune the mechanical properties of PLGA scaffolds; however, little is known about this novel approach. The purpose of this study was to use in vitro and in vivo models to determine the degradative kinetics of additively manufactured test coupons fabricated with PLGA. We hypothesized that 1) increases in infill density would lead to improved initial mechanical properties, and 2) loss of mechanical properties would be constant as a function of time, regardless of implant design. Porous and solid test coupons were fabricated using 85:15 PLGA filament. Coupons were either incubated in serum or implanted subcutaneously in rats for up to 16 weeks. Samples were tested in tension, compression, torsion, and bending on a universal test frame. Variables of interest included, but were not limited to: stiffness, and ultimate force for each unique test. Infill density was the driving factor in test coupon mechanical properties, whereas differences in lattice architecture led to minimal changes. We observed moderate levels of degradation after 8 weeks, and significant decreases for all specimens after 16 weeks. Results from this study suggest substantial degradation of 3-D printed PLGA implants occurs during the 8- to 16-week window, which may be desirable for bone fracture repair applications. This study represents initial findings that will help us better understand the complicated interactions between overall implant design, porosity, and implant biodegradation.


Assuntos
Glicóis , Fenômenos Mecânicos , Ratos , Animais , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Ácido Poliglicólico , Implantes Absorvíveis , Porosidade
10.
Sci Rep ; 14(1): 9495, 2024 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664570

RESUMO

The biological mechanisms regulating tenocyte differentiation and morphological maturation have not been well-established, partly due to the lack of reliable in vitro systems that produce highly aligned collagenous tissues. In this study, we developed a scaffold-free, three-dimensional (3D) tendon culture system using mouse tendon cells in a differentially adherent growth channel. Transforming Growth Factor-ß (TGFß) signaling is involved in various biological processes in the tendon, regulating tendon cell fate, recruitment and maintenance of tenocytes, and matrix organization. This known function of TGFß signaling in tendon prompted us to utilize TGFß1 to induce tendon-like structures in 3D tendon constructs. TGFß1 treatment promoted a tendon-like structure in the peripheral layer of the constructs characterized by increased thickness with a gradual decrease in cell density and highly aligned collagen matrix. TGFß1 also enhanced cell proliferation, matrix production, and morphological maturation of cells in the peripheral layer compared to vehicle treatment. TGFß1 treatment also induced early tenogenic differentiation and resulted in sufficient mechanical integrity, allowing biomechanical testing. The current study suggests that this scaffold-free 3D tendon cell culture system could be an in vitro platform to investigate underlying biological mechanisms that regulate tenogenic cell differentiation and matrix organization.


Assuntos
Diferenciação Celular , Proliferação de Células , Tendões , Tenócitos , Fator de Crescimento Transformador beta1 , Animais , Fator de Crescimento Transformador beta1/farmacologia , Fator de Crescimento Transformador beta1/metabolismo , Tendões/citologia , Tendões/metabolismo , Camundongos , Diferenciação Celular/efeitos dos fármacos , Tenócitos/metabolismo , Tenócitos/citologia , Proliferação de Células/efeitos dos fármacos , Técnicas de Cultura de Células em Três Dimensões/métodos , Células Cultivadas , Técnicas de Cultura de Células/métodos , Matriz Extracelular/metabolismo , Colágeno/metabolismo , Engenharia Tecidual/métodos
11.
J Biomech Eng ; 135(2): 021013, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23445058

RESUMO

Model-based estimation of in vivo contact forces arising between components of a total knee replacement is challenging because such forces depend upon accurate modeling of muscles, tendons, ligaments, contact, and multibody dynamics. Here we describe an approach to solving this problem with results that are tested by comparison to knee loads measured in vivo for a single subject and made available through the Grand Challenge Competition to Predict in vivo Tibiofemoral Loads. The approach makes use of a "dual-joint" paradigm in which the knee joint is alternately represented by (1) a ball-joint knee for inverse dynamic computation of required muscle controls and (2) a 12 degree-of-freedom (DOF) knee with elastic foundation contact at the tibiofemoral and patellofemoral articulations for forward dynamic integration. Measured external forces and kinematics were applied as a feedback controller and static optimization attempted to track measured knee flexion angles and electromyographic (EMG) activity. The resulting simulations showed excellent tracking of knee flexion (average RMS error of 2.53 deg) and EMG (muscle activations within ±10% envelopes of normalized measured EMG signals). Simulated tibiofemoral contact forces agreed qualitatively with measured contact forces, but their RMS errors were approximately 25% of the peak measured values. These results demonstrate the potential of a dual-joint modeling approach to predict joint contact forces from kinesiological data measured in the motion laboratory. It is anticipated that errors in the estimation of contact force will be reduced as more accurate subject-specific models of muscles and other soft tissues are developed.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/fisiologia , Articulação do Joelho/cirurgia , Locomoção , Fenômenos Mecânicos , Modelos Biológicos , Idoso de 80 Anos ou mais , Algoritmos , Fenômenos Biomecânicos , Humanos , Ossos da Perna/fisiologia , Masculino , Músculos/fisiologia
12.
Orthop J Sports Med ; 11(1): 23259671221123342, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36743727

RESUMO

Background: The docking technique is widely used to perform ulnar collateral ligament (UCL) reconstructions because of its high failure torque and reliable clinical outcomes. A double-cortical button technique was recently described, with advantages including the ability to tension the graft at the ulnar and humeral attachments and the creation of single bone tunnels. Purpose/Hypothesis: To compare the biomechanics between the docking and double-button UCL reconstruction techniques using cadaveric specimens. We hypothesized that there would be no difference in postoperative stiffness or maximum strength between the techniques. Study Design: Controlled laboratory study. Methods: Eight matched pairs of cadaveric elbow joints underwent controlled humeral valgus torsion cycles in a test frame. Toe region stiffness, elastic region stiffness, and maximum torque were measured during a 4-step protocol: intact, injured, reconstructed (10 and 1000 cycles), and ramp to failure. Graft strains were calculated using 3-dimensional motion capture. Results: After 10 cycles, intact ligaments from the docking and double-button groups exhibited mean ± SD elastic torsional stiffness of 1.60 ± 0.49 and 1.64 ± 0.35 N·m/deg (P = .827), while docking (1.10 ± 0.39 N·m/deg) and double-button (1.05 ± 0.29 N·m/deg) reconstructions were lower (P = .754). There were no significant differences in maximum torque between the docking (3.45 ± 1.35 N·m) and double-button (3.25 ± 1.31 N·m) groups (P = .777). Similarly, differences in maximum graft strains were not significant between the docking (8.1% ± 7.2%) and double-button (5.5% ± 3.1%) groups (P = .645). The groups demonstrated similar decreases in these measures after cyclic loading. Ramp-to-failure testing showed no significant differences in ultimate torque between the docking (8.93 ± 3.9 N·m) and double-button (9.56 ± 3.5 N·m) groups (P = .739). Conclusion: The biomechanical behavior of the double-button technique was not significantly different from that of the docking technique. Both reconstruction techniques restored joint stability, but neither fully recapitulated preinjury joint stiffness. Clinical Relevance: With its procedural advantages, results preliminarily support the use of the double-button reconstruction technique for UCL reconstruction as a reliable single-tunnel technique for primary or revision cases.

13.
OTA Int ; 6(2 Suppl): e249, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37168029

RESUMO

At the 2021 annual meeting of the Orthopaedic Trauma Association, the Basic Science Focus Forum hosted its first ever debate-style symposium focused on biomechanics and fracture repair. The 3 subjects of debate were "Mechanics versus Biology-Which is 'More Important' to Consider?" "Locked Plate versus Forward Dynamization versus Reverse Dynamization-Which Way Should I Go?" and "Sawbones versus Cadaver Models-What Should I Believe Most?" These debates were held because fracture healing is a highly organized synergistic response between biological factors and the local mechanical environment. Multiple studies have demonstrated that both factors play roles in governing bone healing responses, and the causal relationships between the 2 remain unclear. The lack of clarity in this space has led to a spectrum of research with the common goal of helping surgeons make good decisions. Before reading further, the reader should understand that the questions posed in the debate titles are unanswerable and might represent a false choice. Instead, the reader should appreciate that the debates were held to gain a more thorough understanding of these topics based on the current state of the art of experimental and clinical studies, by using an engaging and thought-provoking format.

14.
J Surg Educ ; 80(7): 1020-1027, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37198080

RESUMO

OBJECTIVE: To determine if preoperative examination of patient additive manufactured (AM) fracture models can be used to improve resident operative competency and patient outcomes. DESIGN: Prospective cohort study. Seventeen matched pairs of fracture fixation surgeries (for a total of 34 surgeries) were performed. Residents first performed a set of baseline surgeries (n = 17) without AM fracture models. The residents then performed a second set of surgeries randomly assigned to include an AM model (n = 11) or to omit it (n = 6). Following each surgery, the attending surgeon evaluated the resident using an Ottawa Surgical Competency Operating Room Evaluation (O-Score). The authors also recorded clinical outcomes including operative time, blood loss, fluoroscopy duration, and patient reported outcome measurement information system (PROMIS) scores of pain and function at 6 months. SETTING: Single-center academic level one trauma center. PARTICIPANTS: Twelve orthopaedic residents, between postgraduate year (PGY) 2 and 5, participated in this study. RESULTS: Residents significantly improved their O-Scores between the first and second surgery when they trained with AM models for the second surgery (p = 0.004, 2.43 ± 0.79 versus 3.73 ± 0.64). Similar improvements were not observed in the control group (p = 0.916, 2.69 ± 0.69 versus 2.77 ± 0.36). AM model training also significantly improved clinical outcomes, including surgery time (p = 0.006), fluoroscopy exposure time (p = 0.002), and patient reported functional outcomes (p = 0.0006). CONCLUSIONS: Conclusions: Training with AM fracture models improves the performance of orthopaedic surgery residents during fracture surgery.


Assuntos
Fraturas Ósseas , Internato e Residência , Impressão Tridimensional , Humanos , Competência Clínica , Educação de Pós-Graduação em Medicina , Fixação de Fratura/educação , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Estudos Prospectivos
15.
Plast Reconstr Surg ; 151(6): 981e-990e, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36729719

RESUMO

BACKGROUND: The pronator teres (PT) to extensor carpi radialis brevis (ECRB) tendon transfer reestablishes wrist extension. Occasionally, the PT periosteal extension is of suboptimal quality to support a strong transfer. In these instances, turnover lengthening techniques can increase usable tendon length. This study characterized the optimal length of tendon turnover and the effect of lengthening on transfer strength. METHODS: Twenty-seven cadaveric extensor tendons were lengthened using the turnover lengthening technique with 1 to 3 cm of tendon overlap. PT-to-ECRB tendon transfers were performed with native or lengthened ECRB tendons. Tensile testing was used to evaluate stress relaxation and load to failure. RESULTS: The median maximum load to failure increased with increasing overlap length, measuring 35.6 N (quartile 1, 30.2 N; quartile 3, 38.6 N) for 1 cm, 66.0 N (quartile 1, 59.1 N; quartile 3, 74.7 N) for 2 cm, and 96.6 N (quartile 1, 85.9; quartile 3, 114.9 N) for 3 cm of overlap ( P < 0.05). Failure occurred most frequently at the junction of the central overlap and native tendon. Tendons lengthened with 2 and 3 cm of overlap displayed greater stiffness than those with 1 cm ( P < 0.05). Lengthening the ECRB tendon with 2 or 3 cm of overlap did not disrupt the strength or stiffness of subsequent PT-to-ECRB tendon transfers. CONCLUSIONS: Turnover tendon lengthening does not detrimentally affect PT-to-ECRB tendon transfer. Greater overlap lengthening distance confers greater stiffness and resistance to rupture. When the periosteal extension of the PT tendon avulses or is of poor quality, the ECRB tendon can be lengthened using the turnover tendon lengthening technique to facilitate a robust transfer.


Assuntos
Transferência Tendinosa , Punho , Humanos , Transferência Tendinosa/métodos , Tenotomia , Tendões/cirurgia , Músculo Esquelético
16.
JHEP Rep ; 5(9): 100760, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37534230

RESUMO

Background & Aims: Glisson's capsule is the interstitial connective tissue that surrounds the liver. As part of its normal physiology, it withstands significant daily changes in liver size. The pathophysiology of the capsule in disease is not well understood. The aim of this study was to characterise the changes in capsule matrix, cellular composition, and mechanical properties that occur in liver disease and to determine whether these correlate with disease severity or aetiology. Methods: Samples from ten control patients, and six with steatosis, seven with moderate fibrosis, and 37 with cirrhosis were collected from autopsies, intraoperative biopsies, and liver explants. Matrix proteins and cell markers were assessed by staining and second harmonic generation imaging. Mechanical tensile testing was performed on a test frame. Results: Capsule thickness was significantly increased in cirrhotic samples compared with normal controls irrespective of disease aetiology (70.12 ± 14.16 µm and 231.58 ± 21.82 µm, respectively), whereas steatosis and moderate fibrosis had no effect on thickness (90.91 ± 11.40 µm). Changes in cirrhosis included an increase in cell number (fibroblasts, vascular cells, infiltrating immune cells, and biliary epithelial cells). Key matrix components (collagens 1 and 3, hyaluronan, versican, and elastin) were all deposited in the lower capsule, although only the relative amounts per area of hyaluronan and versican were increased. Organisational features, including crimping and alignment of collagen fibres, were also altered in cirrhosis. Unexpectedly, capsules from cirrhotic livers had decreased resistance to loading compared with controls. Conclusions: The liver capsule, similar to the parenchyma, is an active site of disease, demonstrating changes in matrix and cell composition as well as mechanical properties. Impact and implications: We assessed the changes in composition and response to stretching of the liver outer sheath, the capsule, in human liver disease. We found an increase in key structural components and numbers of cells as well as a change in matrix organisation of the capsule during the later stages of disease. This allows the diseased capsule to stretch more under any given force, suggesting that it is less stiff than healthy tissue.

17.
Sci Transl Med ; 15(722): eadf1690, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37967202

RESUMO

Conventional microdiscectomy treatment for intervertebral disc herniation alleviates pain but does not repair the annulus fibrosus, resulting in a high incidence of recurrent herniation and persistent dysfunction. The lack of repair and the acute inflammation that arise after injury can further compromise the disc and result in disc-wide degeneration in the long term. To address this clinical need, we developed tension-activated repair patches (TARPs) for annulus fibrosus repair and local delivery of the anti-inflammatory factor anakinra (a recombinant interleukin-1 receptor antagonist). TARPs transmit physiologic strain to mechanically activated microcapsules embedded within the patch, which release encapsulated bioactive molecules in direct response to spinal loading. Mechanically activated microcapsules carrying anakinra were loaded into TARPs, and the effects of TARP-mediated annular repair and anakinra delivery were evaluated in a goat model of annular injury in the cervical spine. TARPs integrated with native tissue and provided structural reinforcement at the injury site that prevented aberrant disc-wide remodeling resulting from detensioning of the annular fibrosus. The delivery of anakinra by TARP implantation increased matrix deposition and retention at the injury site and improved maintenance of disc extracellular matrix. Anakinra delivery additionally attenuated the inflammatory response associated with TARP implantation, decreasing osteolysis in adjacent vertebrae and preserving disc cellularity and matrix organization throughout the annulus fibrosus. These results demonstrate the therapeutic potential of TARPs for the treatment of intervertebral disc herniation.


Assuntos
Degeneração do Disco Intervertebral , Deslocamento do Disco Intervertebral , Disco Intervertebral , Nanofibras , Animais , Deslocamento do Disco Intervertebral/tratamento farmacológico , Deslocamento do Disco Intervertebral/cirurgia , Cabras , Cápsulas , Proteína Antagonista do Receptor de Interleucina 1/farmacologia , Proteína Antagonista do Receptor de Interleucina 1/uso terapêutico , Degeneração do Disco Intervertebral/cirurgia
18.
Clin Biomech (Bristol, Avon) ; 97: 105709, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35780699

RESUMO

BACKGROUND: Treatment of proximal humerus periprosthetic fractures is challenging. It remains difficult to achieve robust fixation of the proximal fragment to the locking plate using cerclage wiring and/or unicortical screws. Use of polyaxial tangentially directed bicortical locking screws increases screw purchase, but it is unclear if this option provides robust fixation. This biomechanical study compares fixation of constructs using cerclage wires, bicortical locking screws, and a hybrid method utilizing both methods. METHODS: Uncemented humeral stems were implanted into synthetic humeri and Type C periprosthetic fractures were simulated with a 1 cm transverse osteotomy. Distal ends of locking plates were secured with bicortical non-locking screws. The proximal ends were supported by either isolated cerclage wires, polyaxial locking screws, or a hybrid combination of both (n = 6 for each group). A universal test frame was used for non-destructive torsion and cyclic axial compression tests. 3-D motion tracking was employed to determine stiffnesses and relative interfragmentary motions. FINDINGS: Isolated screw constructs showed significantly increased resistance against torsional movement, bending, and shear, (p < 0.05) in comparison to cerclage constructs. The hybrid construct provided no significant changes in stability over the isolated screw construct. INTERPRETATION: Addition of cerclage wires in this synthetic bone model of Type C periprosthetic humerus fractures did not add significant stability to proximal bicortical locking plate fixation. Considering risks of tissue stripping and nerve injury, usage of cerclage wires in a similar clinical setting should be chosen carefully, especially when bicortical fixation around the prosthetic stem can be achieved.


Assuntos
Fraturas Periprotéticas , Fenômenos Biomecânicos , Placas Ósseas , Fixação Interna de Fraturas/métodos , Humanos , Úmero/cirurgia , Fraturas Periprotéticas/cirurgia
19.
Clin Biomech (Bristol, Avon) ; 95: 105636, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35428007

RESUMO

BACKGROUND: This systematic review explores the differences in the intrinsic biomechanical properties of different graft sources used in anterior cruciate ligament (ACL) reconstruction as tested in a laboratory setting. METHODS: Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, two authors conducted a systematic review exploring the biomechanical properties of ACL graft sources (querying PubMed, Cochrane, and Embase databases). Using the keywords "anterior cruciate ligament graft," "biomechanics," and "biomechanical testing," relevant articles of any level of evidence were identified as eligible and included if they reported on the biomechanical properties of skeletally immature or mature ACL grafts solely and if the grafts were studied in vitro, in isolation, and under similar testing conditions. Studies were excluded if performed on both skeletally immature and mature or non-human grafts, or if the grafts were tested after fixation in a cadaveric knee. For each graft, failure load, stiffness, Young's modulus, maximum stress, and maximum strain were recorded. FINDINGS: Twenty-six articles were included. Most studies reported equal or increased biomechanical failure load and stiffness of their tested bone-patellar tendon-bone, hamstring, quadriceps, peroneus longus, tibialis anterior and posterior, Achilles, tensor fascia lata, and iliotibial band grafts compared to the native ACL. All recorded biomechanical properties had similar values between graft types. INTERPRETATION: Most grafts used for ACL reconstruction are biomechanically superior to the native ACL. Utilizing a proper graft, combined with a standard surgical technique and a rigorous rehabilitation before and after surgery, will improve outcomes of ACL reconstruction.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Músculos Isquiossurais , Ligamento Patelar , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Fenômenos Biomecânicos , Humanos , Ligamento Patelar/cirurgia
20.
OTA Int ; 5(1 Suppl): e164, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35282393

RESUMO

Objectives: Current surgical fracture treatment paradigms, which use rigid metallic constructs to heal bones, provide reasonable clinical outcomes; however, they do not leverage recent advances in our understanding of bone healing and mechanotransduction throughout bone healing. The objective of this review was to investigate the efficacy and potential clinical applicability of surgical techniques and implants that deliberately introduce interfragmentary motion throughout the healing process. Methods: The authors searched PubMed and Google Scholar databases for articles reporting on fracture repair using dynamic locking plates, dynamized surgical techniques, and reverse dynamization. Data collection also included assessment of additively manufactured (AM) implants that provide dynamic mechanical behaviors. Results: Forty articles were included for final review. It was found that accelerated rates of fracture healing can be achieved with staged 2-part surgeries or dynamic implant designs. Temporal dynamization, where static fixation of bones is followed by the introduction of micromotion and controlled loading, has been shown to improve callus volume and accelerate the healing response. Reverse dynamization, where micromotion is encouraged during early callus formation and arrested later, may represent a significant advance for the treatment of critical defect injuries. Advances in AM techniques will likely provide the ability to create high-resolution implants capable of dynamized and reverse dynamized modalities. Conclusions: There is no one-size-fits-all approach to optimization of fracture healing. However, it has been clearly demonstrated that fracture treatment can be enhanced by systematically altering the construct stiffness throughout the different phases of healing, which may be achieved with AM implant designs.