Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Catheter Cardiovasc Interv ; 96(2): 450-458, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31785087

RESUMO

BACKGROUND: Evidence is lacking to standardize post-procedure care after transcatheter aortic valve replacement (TAVR). OBJECTIVE: We report on the findings of the post-procedure sub-study of the multimodality, multidisciplinary but minimalist TAVR (3M TAVR) study. METHODS: A standardized protocol to guide monitoring, early mobilization, reconditioning, communication, and criteria-driven discharge was implemented in a multicenter, prospective, sequential case series study in 13 North American low, medium, and high-volume centers in 2015-2017. Outcome measures pertaining to post-procedure care included avoidance of invasive lines and delirium, in-hospital bed utilization, patient disposition at the time of discharge, and 30-day use of nonelective medical services. RESULTS: Four hundred eleven participants were enrolled. In the post-procedure phase, 365 (88.8%) participants were admitted without a temporary pacemaker; urinary catheterization was avoided in 402 (97.8%) participants. Of note, 91.7% received care in a single unit (critical care: 72.5%; cardiac telemetry: 19.2%); 99.0% were discharged home. At the time of 30-day follow-up, 6 (1.6%) participants required admission to a rehabilitation or a skilled nursing facility; 30-day emergency department visits were 13.5%. CONCLUSIONS: The implementation of the 3M TAVR standardized accelerated reconditioning protocol is a safe and effective strategy to facilitate next-day discharge home after TAVR in centers of varying size.


Assuntos
Estenose da Valva Aórtica/cirurgia , Tempo de Internação , Alta do Paciente , Cuidados Pós-Operatórios , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estimulação Cardíaca Artificial , Terapia Combinada , Deambulação Precoce , Estudos de Viabilidade , Feminino , Humanos , Masculino , América do Norte , Equipe de Assistência ao Paciente , Cuidados Pós-Operatórios/efeitos adversos , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Cateterismo Urinário
2.
Catheter Cardiovasc Interv ; 84(6): 859-67, 2014 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-24760495

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an increasingly available therapy for the management of aortic stenosis in higher risk populations. Beyond addressing the procedural challenges, centers must attend to the unique requirements of developing TAVR programs from referral to follow-up. AIM: The aim of this article is to outline the recommendations for best practice for program development from centers with early and extensive experience. RECOMMENDATIONS: The guideline-recommended Heart Team approach requires interdisciplinary agreements, delineation of roles and responsibilities, and the development of the role of the TAVR Coordinator. To support appropriate case selection, the screening and evaluation must be organized in a comprehensive clinic visit. In addition to the multimodality imaging tests, the assessment of functional status and frailty is pivotal to the eligibility decision. Throughout the TAVR trajectory, careful attention must be afforded to the integration of geriatric best practices. Pre-procedure care requires patient and family education to manage expectations and facilitate early discharge planning. Peri-procedural care planning, including equipment requirements, monitoring protocols, and emergency intervention agreements, contributes to procedural success. The aims of post-procedure care are to monitor the recovery, facilitate the rapid return to baseline status, and optimize length of stay. TAVR programs require data management strategies to facilitate and monitor program growth, support program evaluation, and meet the requirements for submission to national registries. CONCLUSION: TAVR represents a paradigm shift in the management of structural heart disease. Programmatic success and patient outcomes depend on the development of a comprehensive and collaborative program tailored to TAVR.


Assuntos
Estenose da Valva Aórtica/terapia , Benchmarking/normas , Cateterismo Cardíaco/normas , Implante de Prótese de Valva Cardíaca/normas , Estenose da Valva Aórtica/diagnóstico , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Comportamento Cooperativo , Diagnóstico por Imagem/normas , Definição da Elegibilidade/normas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Comunicação Interdisciplinar , Equipe de Assistência ao Paciente/normas , Valor Preditivo dos Testes , Desenvolvimento de Programas/normas , Indicadores de Qualidade em Assistência à Saúde/normas , Resultado do Tratamento
3.
JACC Adv ; 3(7): 100981, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39130036

RESUMO

Shared decision-making (SDM) and multidisciplinary team-based care delivery are recommended across several cardiology clinical practice guidelines. However, evidence for benefit and guidance on implementation are limited. Informed consent, the use of patient decision aids, or the documentation of these elements for governmental or societal agencies may be conflated as SDM. SDM is a bidirectional exchange between experts: patients are the experts on their goals, values, and preferences, and clinicians provide their expertise on clinical factors. In this Expert Panel perspective, we review the current state of SDM in team-based cardiovascular care and propose best practice recommendations for multidisciplinary team implementation of SDM.

4.
Eur J Cardiovasc Nurs ; 19(6): 537-544, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32498556

RESUMO

The COVID-19 pandemic continues to significantly impact the treatment of people living with aortic stenosis, and access to transcatheter aortic valve implantation. Transcatheter aortic valve implantation (TAVI) programmes require unique coordinated processes that are currently experiencing multiple disruptions and are guided by rapidly evolving protocols. We present a series of recommendations for TAVI programmes to adapt to the new demands, based on recent evidence and the international expertise of nurse leaders and collaborators in this field. Although recommended in most guidelines, the uptake of the role of the TAVI programme nurse is uneven across international regions. COVID-19 is further highlighting why a nurse-led central point of coordination and communication is a vital asset for patients and programmes. We propose an alternative streamlined evaluation pathway to minimize patients' pre-procedure exposure to the hospital environment while ensuring appropriate treatment decision and shared decision-making. The competing demands created by COVID-19 require vigilant wait list management, with risk stratification, telephone surveillance and optimized triage and prioritization. A minimalist approach with close scrutiny of all parts of the procedure has become an imperative to avoid any complications and ensure patients' accelerated recovery. Lastly, we outline a nurse-led protocol of rapid mobilization and reconditioning as an effective strategy to facilitate safe next-day discharge home. As the pandemic abates, TAVI programmes must facilitate access to care without compromising patient safety, enable hospitals to manage the competing demands created by COVID-19 and establish new processes to support patients living with valvular heart disease.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Betacoronavirus , Infecções por Coronavirus , Pandemias , Pneumonia Viral , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/cirurgia , COVID-19 , Humanos , Alta do Paciente , Segurança do Paciente , Guias de Prática Clínica como Assunto , SARS-CoV-2 , Resultado do Tratamento
5.
Am J Cardiol ; 116(2): 264-9, 2015 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-25963221

RESUMO

Transcatheter aortic valve replacement (TAVR) is an effective treatment for severe symptomatic aortic stenosis (AS) in patients who are inoperable or at high risk for surgery. However, the intermediate- to long-term mortality is high, emphasizing the importance of patient selection. We, therefore, sought to evaluate the prognostic value of frailty in older recipients of TAVR, hypothesizing that frail patients would experience a higher mortality rate and a higher likelihood of poor outcome 1 year after TAVR. This substudy of the Placement of Aortic Transcatheter Valves trial was conducted at 3 high-enrolling sites where frailty was assessed systematically before TAVR. In total, 244 patients received TAVR at the participating sites. Frailty was assessed using a composite of 4 markers (serum albumin, dominant handgrip strength, gait speed, and Katz activity of daily living survey), which were combined into a frailty score. The cohort was dichotomized at median frailty score. Outcomes measures were the time to death from any cause for >1 year of follow-up and poor outcome at 1 year. Poor outcome was defined as (1) death, (2) Kansas City Cardiomyopathy Questionnaire overall summary (KCCQ-OS) score <60, or (3) decrease of ≥10 points in the KCCQ-OS score from baseline to 1 year. At 1 year, the Kaplan-Meier-estimated all-cause mortality rate was 32.7% in the frail group and 15.9% in the nonfrail group (log-rank p = 0.004). At 1 year, poor outcome occurred in 50.0% of the frail group and 31.5% of the nonfrail group (p = 0.02). In conclusion, frailty was associated with increased mortality and a higher rate of poor outcome 1 year after TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Idoso Fragilizado , Substituição da Valva Aórtica Transcateter , Idoso , Estenose da Valva Aórtica/mortalidade , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Prognóstico , Qualidade de Vida , Inquéritos e Questionários , Taxa de Sobrevida/tendências , Resultado do Tratamento , Estados Unidos/epidemiologia
6.
JACC Cardiovasc Interv ; 5(9): 974-81, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22995885

RESUMO

OBJECTIVES: This study sought to evaluate the impact of frailty in older adults undergoing transcatheter aortic valve replacement (TAVR) for symptomatic aortic stenosis. BACKGROUND: Frailty status impacts prognosis in older adults with heart disease; however, the impact of frailty on prognosis after TAVR is unknown. METHODS: Gait speed, grip strength, serum albumin, and activities of daily living status were collected at baseline and used to derive a frailty score among patients who underwent TAVR procedures at a single large-volume institution. The cohort was dichotomized on the basis of median frailty score into frail and not frail groups. The impact of frailty on procedural outcomes (stroke, bleeding, vascular complications, acute kidney injury, and mortality at 30 days) and 1-year mortality was evaluated. RESULTS: Frailty status was assessed in 159 subjects who underwent TAVR (age 86 ± 8 years, Society of Thoracic Surgery Risk Score 12 ± 4). Baseline frailty score was not associated with conventionally ascertained clinical variables or Society of Thoracic Surgery score. Although high frailty score was associated with a longer post-TAVR hospital stay when compared with lower frailty score (9 ± 6 days vs. 6 ± 5 days, respectively, p = 0.004), there were no significant crude associations between frailty status and procedural outcomes, suggesting adequacy of the standard selection process for identifying patients at risk for periprocedural complications after TAVR. Frailty status was independently associated with increased 1-year mortality (hazard ratio: 3.5, 95% confidence interval: 1.4 to 8.5, p = 0.007) after TAVR. CONCLUSIONS: Frailty was not associated with increased periprocedural complications in patients selected as candidates to undergo TAVR but was associated with increased 1-year mortality after TAVR. Further studies will evaluate the independent value of this frailty composite in older adults with aortic stenosis.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/efeitos adversos , Avaliação Geriátrica , Implante de Prótese de Valva Cardíaca/efeitos adversos , Atividades Cotidianas , Injúria Renal Aguda/etiologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Biomarcadores/sangue , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Comorbidade , Feminino , Idoso Fragilizado , Marcha , Força da Mão , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemorragia/etiologia , Mortalidade Hospitalar , Hospitais com Alto Volume de Atendimentos , Humanos , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Cidade de Nova Iorque , Modelos de Riscos Proporcionais , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Albumina Sérica/análise , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento , Doenças Vasculares/etiologia
7.
Clin Cardiol ; 35(5): 307-14, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22331630

RESUMO

BACKGROUND: In the transcatheter aortic valve replacement era, characterization of functional status in older adults with aortic stenosis (AS) is essential. Gait speed (GS) is emerging as a marker of frailty and predictor of outcomes in older adults undergoing cardiovascular intervention. The objective of this study was to delineate the prevalence of slow GS, evaluate the association of GS with factors used in standard cardiovascular assessments, and evaluate the association of GS with dependence in activities of daily living (ADLs) in older adults with AS. HYPOTHESIS: We hypothesized that gait speed would not be associated with clinical factors, but would be associated with ADLs. METHODS: We evaluated GS, ADLs dependence, and Society of Thoracic Surgery score along with clinical and functional assessments in 102 older adults with AS being evaluated for transcatheter valve. Gait speed <0.5 m/s was considered slow, and GS ≥0.5 m/s was considered preserved. We assessed the association of covariates with GS as well as with ADLs dependence. RESULTS: Median GS was 0.37 m/s (interquartile range, 0.0-0.65 m/s). Sixty-four (63%) subjects had slow GS. Of commonly employed clinical covariates, only prior coronary intervention and serum albumin were weakly associated with GS. However, GS was independently associated with ADLs dependence (Odds ratio: 1.52 [1.21-1.91] for every 0.1 m/s decrease in GS; P = 0.0003). CONCLUSIONS: Although the prevalence of slow GS in a population of elderly patients with severe AS being screened for transcatheter valve was high, there were only weak associations between GS and other risk stratifying tools. The strong association between GS and dependent functional status suggests that assessment of gait speed is a useful, objectively measurable, risk stratification tool in this population.


Assuntos
Atividades Cotidianas , Estenose da Valva Aórtica/fisiopatologia , Marcha/fisiologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Estudos Transversais , Feminino , Humanos , Masculino , Prevalência , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA