Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Transfusion ; 58(5): 1100-1107, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29574766

RESUMO

BACKGROUND: Di(2-ethylhexyl)phthalate (DEHP) makes polyvinyl chloride flexible for use in blood bags and stabilizes the red blood cell (RBC) membrane preventing excessive hemolysis. DEHP migrates into the blood product and rodent studies have suggested that DEHP exposure may be associated with adverse health effects albeit at high dosages. Although structurally and functionally similar to DEHP, di(2-ethylhexyl)terephthalate (DEHT; or Eastman 168 SG [Eastman Chemical Company]) is metabolically distinct with a comprehensive and benign toxicology profile. This study evaluated RBC stability in DEHT-plasticized bags with AS-1 and PAGGSM compared to conventional DEHP-plasticized bags with AS-1. STUDY DESIGN AND METHODS: Thirty-six whole blood units were collected into CPD solution, leukoreduced, centrifuged, and divided into RBCs and plasma. To limit donor-related variability, three ABO-identical RBCs were mixed together and then divided equally and stored among the three different plasticizer and additive solution combinations. RBCs from 12 trios were analyzed for a standard panel of in vitro variables on Day 0 and after storage. RESULTS: No individual bag on Day 42 exceeded the US 1.0% hemolysis criteria. While hemolysis during storage was higher in the DEHT bags, the PAGGSM RBCs were close to the control RBCs (0.38% vs. 0.32%, respectively). ATP retention was higher than 70% and potassium levels were similar regardless of plasticizer. Additional RBC variables exhibited some significant differences but were not viewed as clinically important. CONCLUSION: DEHT/PAGGSM provides similar hemolysis protection to that of DEHP/AS-1. Although hemolysis values with DEHT and AS-1 are higher than that of DEHP, DEHT is a potential DEHP alternative.


Assuntos
Preservação de Sangue/métodos , Eritrócitos/citologia , Plastificantes/química , Embalagem de Produtos/métodos , Soluções/química , Adenina , Glucose , Guanosina , Hemólise/efeitos dos fármacos , Humanos , Manitol , Ácidos Ftálicos , Cloreto de Polivinila , Cloreto de Sódio
2.
Transfusion ; 48(1): 147-52, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17894787

RESUMO

BACKGROUND: Automated collection of blood components offers multiple advantages and has prompted development of portable devices. This study sought to document the biochemical and hematologic properties and in vivo recovery of red cells (RBCs) collected via a new device that employed a variable-volume centrifugal separation chamber. STUDY DESIGN AND METHODS: Normal subjects (n = 153) donated 2 units of RBCs via an automated blood collection system (Cymbal, Haemonetics). Procedures were conducted with wall outlet power (n = 49) or the device's battery source (n = 104). Units were collected with or without leukoreduction filtration and were stored in AS-3 for 42 days. The units were assessed via standard biochemical and hematologic tests before and after storage, and 24 leukoreduced (LR) and 24 non-LR RBCs were radiolabeled on Day 42 with Na(2)(51)CrO(4) for autologous return to determine recovery at 24 hours with concomitant determination of RBC volume via infusion of (99m)Tc-labeled fresh RBCs. RESULTS: Two standard RBC units (targeted to contain 180 mL of RBCs plus 100 mL of AS-3) could be collected in 35.7 +/- 2.0 minutes (n = 30) or 40.3 +/- 2.7 minutes for LR RBCs (n = 92). An additional 31 collections were conducted successfully with intentional filter bypassing. RBC units contained 104 +/- 4.1 percent of their targeted volumes (170-204 mL of RBCs), and LR RBCs contained 92 percent of non-LR RBCs' hemoglobin. All LR RBCs contained less than 1 x 10(6) white blood cells. Mean hemolysis was below 0.8 percent (Day 42) for all configurations. Adenosine triphosphate was well preserved. Mean recovery was 82 +/- 4.9 percent for RBCs and 84 +/- 7.0 percent for LR RBCs. CONCLUSIONS: The Cymbal device provided quick and efficient collection of 2 RBC units with properties meeting regulatory requirements and consistent with good clinical utility.


Assuntos
Remoção de Componentes Sanguíneos/instrumentação , Separação Celular/instrumentação , Eritrócitos , Trifosfato de Adenosina/análise , Automação , Separação Celular/métodos , Desenho de Equipamento , Contagem de Eritrócitos , Transfusão de Eritrócitos , Hemoglobinas/análise , Hemólise , Humanos , Contagem de Leucócitos , Procedimentos de Redução de Leucócitos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA