Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Acta Psychiatr Scand ; 147(4): 322-332, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36744383

RESUMO

OBJECTIVE: Electroconvulsive therapy (ECT) is an effective treatment for severe depressive symptoms, yet more research is needed to examine predictors of treatment response, and factors associated with response in patients not initially improving with treatment. This study reports factors associated with time to response (early vs. late) to ECT in a real-world setting. METHODS: This was a retrospective, single-center cohort study of patients endorsing moderate to severe depressive symptoms using the Quick Inventory of Depressive Symptomatology (QIDS; QIDS>10). Response was defined as 50% or greater decrease in QIDS score from baseline. We used logistic regression to predict response at treatment #5 (early response) as well as after treatment #5 (late response) and followed patients through ECT discontinuation or through treatment #20. RESULTS: Of the 1699 patients included in this study, 555 patients (32.7%) responded to ECT treatment at treatment #5 and 397 (23.4%) responded after treatment #5. Among patients who did not respond by treatment #5, those who switched to brief pulse width ECT from ultrabrief pulse ECT had increased odds of response after treatment #5 compared with patients only receiving ultrabrief pulse (aOR = 1.55, 95% CI: 1.16-2.07). Additionally, patients with less improvement in QIDS from baseline to treatment #5 had decreased odds of response after treatment #5 (aOR = 0.97, 95% CI = 0.97-0.98). CONCLUSION: Among depressed patients treated with ECT, response occurred in 56.0% of patients by treatment #20. Patient receiving ultrabrief pulse ECT at baseline and who did not respond by treatment #5 had greater odds of subsequent response if switched to brief pulse ECT than if continued with ultrabrief pulse.


Assuntos
Eletroconvulsoterapia , Resultado do Tratamento , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Prognóstico , Fatores de Tempo , Demografia , Modelos Logísticos , Estudos Retrospectivos
2.
Acta Psychiatr Scand ; 148(6): 553-560, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37643775

RESUMO

OBJECTIVE: Suicidal ideation (SI) is common in patients with depressive symptoms, who are the most common recipients of electroconvulsive therapy (ECT). We sought to quantify changes in self-reported SI occurring during treatment with ECT, and to identify factors associated with persistence of SI in patients beginning treatment with SI. METHOD: Retrospective, single-center cohort study of patients receiving ECT and who self-reported symptoms using Quick Inventory of Depressive Symptomatology (QIDS) prior to ECT and after treatment #5 or #10. Changes in QIDS-reported SI over the course of ECT were calculated, and logistic regression models were performed to assess factors associated with reporting SI at the end of treatment. RESULTS: 2554 provided baseline and follow-up SI scores, of whom, 1931 (75.6%) endorsed SI at baseline. There was a reduction in SI with ECT treatment (McNemar's test; df = 1, Χ2 = 803.7; p < 0.001), and in adjusted models 64.0% of individuals with baseline SI reported resolution of SI with ECT treatment, while 3.3% without baseline SI reported SI at the end of treatment. Higher baseline SI severity and outpatient treatment were associated with a higher odds of persistent SI among individuals beginning treatment with SI. CONCLUSION: Electroconvulsive therapy treatment was associated with reductions in self-reported SI. These results support the use of ECT in the treatment of patients with SI, but further research is needed to determine the effects of ECT on suicidal behavior.


Assuntos
Eletroconvulsoterapia , Humanos , Eletroconvulsoterapia/métodos , Ideação Suicida , Estudos Retrospectivos , Estudos de Coortes , Autorrelato , Resultado do Tratamento
3.
J ECT ; 39(3): 173-178, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37027490

RESUMO

OBJECTIVES: Electroconvulsive therapy (ECT) is an essential procedure for a range of psychiatric conditions. Multiple single-center studies have documented reduction in ECT administration in 2020 because of the coronavirus disease 2019 pandemic, but there have been little nationally representative data from the United States. The aim of this study was to examine the demographics of patients receiving ECT in 2019 and 2020 and to characterize temporal and regional variations in ECT utilization. METHODS: The 2019 and 2020 National Inpatient Sample, an administrative database of inpatient hospitalizations in the United States, was queried for hospitalizations involving the delivery of ECT based on procedural codes. Overall number of ECT procedures was calculated based on the overall number of ECT procedural claims. RESULTS: In the 2019 NIS, 14,230 inpatient hospitalizations (95% confidence interval, 12,936-15,524) involved the use of ECT, with a cumulative 52,450 inpatient ECT procedures administered. In 2020, the number of inpatient hospitalizations with ECT decreased to 12,055 (95% confidence interval, 10,878-13,232), with a 10.0% reduction in overall procedures to 47,180. Whereas January and February ECT hospitalizations were comparable in both years, ECT hospitalizations decreased by more than 25% in March through May 2020 relative to 2019 volume. There was regional variability in the change in ECT utilization between 2019 and 2020. CONCLUSIONS: Electroconvulsive therapy use among general hospital inpatients declined between 2019 and 2020, with regional variability in the magnitude of change. Further study is warranted into the root causes and optimal responses to these changes.


Assuntos
COVID-19 , Eletroconvulsoterapia , Transtornos Mentais , Humanos , Estados Unidos , Eletroconvulsoterapia/métodos , Pacientes Internados , Hospitalização , Transtornos Mentais/terapia
4.
Am J Geriatr Psychiatry ; 30(7): 790-798, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34996701

RESUMO

OBJECTIVES: This study explores the association between baseline impaired global cognitive function and changes in global cognitive function and depression among geriatric patients undergoing acute course electroconvulsive therapy (ECT). DESIGN: Retrospective cohort study. SETTING: Single freestanding psychiatric hospital. PARTICIPANTS: Patients aged 50 and older receiving ECT. INTERVENTIONS: 10 ECT treatments. MEASUREMENTS: Cognitive assessments with the Montreal Cognitive Assessment (MoCA). Depression assessment with the Quick Inventory of Depressive Symptomatology Self Report 16 item scale (QIDS). RESULTS: Baseline and follow-up data were available for 684 patients. On average, patients with baseline normal cognition (MoCA ≥26; N = 371) had a decrease in MoCA of -1.44±0.26 points over the course of treatment, while those with baseline impaired global cognitive function (MoCA <26; N = 313) had an increase in MoCA of 1.72±0.25 points. Baseline cognitive status was not associated with a differential response on the QIDS. CONCLUSIONS: Patients with baseline impaired global cognitive function did not demonstrate a worsening in cognition following ECT, and baseline global cognitive function was not associated with a differential change in depression with ECT. These results suggest that impaired global cognitive function should not be viewed as a contraindication to ECT in geriatric patients.


Assuntos
Eletroconvulsoterapia , Idoso , Cognição , Eletroconvulsoterapia/efeitos adversos , Humanos , Testes de Estado Mental e Demência , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
5.
Acta Psychiatr Scand ; 145(1): 100-108, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34662429

RESUMO

OBJECTIVES: Electroconvulsive therapy (ECT) is an effective treatment for depressive disorders and approved for use in adolescents and adults, but it is unclear whether efficacy or cognitive side effect burden differs with age or if effectiveness in usual clinical practice matches that in prospective studies. We examined the effects of ECT on depression and cognition in a large clinical cohort. METHODS: A retrospective cohort study of patients ages 16 and older receiving ECT between 2011 and 2020 and who were evaluated with the Quick Inventory of Depressive Symptomatology (QIDS), the Behavior and Symptom Identification Scale-24 (BASIS-24), and the Montreal Cognitive Assessment (MoCA) at baseline and after treatment #10. RESULTS: Among 1698 patients, ECT was associated with a decrease in depression symptoms (QIDS reduction from 17.1 ± 4.9 to 10.1 ± 5.2) and improvement in self-reported mental health (BASIS-24 scores improved from 1.92 ± 0.55 to 1.17 ± 0.60). There was a reduction in MoCA scores from 25.8 ± 3.1 to 25.4 ± 3.1. In multivariate models, age was not associated with a differential QIDS or BASIS-24 response, but older age was associated with a lesser reduction in MoCA. CONCLUSION: Among 1698 patients aged 16 and older, ECT was associated with improvement in depression and overall self-reported mental health, with a slight decrease in cognition. Age was not associated with changes in efficacy, but older age was associated with a lesser cognitive change as measured by the MoCA. These results provide normative data of real-world effectiveness of ECT, and add further support to its utility in patients with severe psychiatric illness.


Assuntos
Eletroconvulsoterapia , Adolescente , Adulto , Idoso , Cognição , Humanos , Testes de Estado Mental e Demência , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
6.
J ECT ; 38(3): 171-175, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35389952

RESUMO

OBJECTIVE: While emerging evidence suggests that electroconvulsive therapy (ECT) is an effective treatment for depressive symptoms in patients with co-occurring borderline personality disorder (BPD) traits, it is unclear whether the presence of BPD traits modulates the tolerability of ECT. This study estimates the association between BPD traits and retention in acute course ECT treatment. METHODS: This study used a retrospective cohort of patients receiving ECT between 2015 and 2020 and who were assessed using the McLean Screening Instrument for BPD, the Quick Inventory of Depressive Symptomatology Self-Report 16-item scale, and the Montreal Cognitive Assessment before initiating treatment. RESULTS: One thousand five hundred eight patients received ECT during the study period, of whom 277 (18.4%) screened positive for BPD traits. Borderline personality disorder traits were associated with a higher odds of remaining in ECT for at least 10 treatments (adjusted odds ratio, 1.502; 95% confidence interval, 1.11-2.02; P = 0.007). Among individual symptom domains, only endorsing chronically feeling empty was associated with duration in ECT treatment. CONCLUSIONS: Among patients receiving ECT, screening positive for BPD traits was associated with a higher odds of receiving at least 10 ECT treatments. These results support the overall tolerability of ECT in patients with BPD traits.


Assuntos
Transtorno da Personalidade Borderline , Eletroconvulsoterapia , Estudos de Coortes , Humanos , Estudos Retrospectivos , Resultado do Tratamento
7.
Eur Arch Psychiatry Clin Neurosci ; 271(1): 191-197, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33196856

RESUMO

Right unilateral ultrabrief pulse (RUL-UBP) ECT has emerged as a promising technique for minimizing cognitive side effects of ECT while retaining clinical efficacy, but it is unknown how often patients will require alternative treatment parameters and at what point in the treatment course this occurs. To better define this problem, this study analyzes continuation in RUL-UBP ECT in a retrospective cohort of patients beginning acute course treatment. A single-center retrospective chart review was conducted of adult patients receiving a first lifetime course of ECT from 2010 to 2017 starting with RUL-UBP treatment parameters. 1793 patients met study criteria. Patients received a mean of 10.0 ± 3.2 ECT treatments, of which a mean of 8.4 ± 3.4 were RUL-UBP treatments; proportion using RUL-UBP through 12 treatments was 57.8%. In total, 65.6% of patients were treated with RUL-UPB ECT exclusively. Mean dose increased from 7.6 × seizure threshold at the second RUL-UBP treatment to 14.3 × seizure threshold at the twelfth RUL-UBP treatment. Rates of continuation in RUL-UBP ECT did not differ based on age or on primary diagnosis of major depression vs. bipolar disorder. Among patients beginning acute-course treatment using RUL-UPB ECT, two thirds were treated with these parameters exclusively. Among patients who received twelve RUL-UBP treatments, mean final dose was 14.3 × seizure threshold. Further studies regarding optimal dosing of RUL-UBP ECT are indicated.


Assuntos
Centros Médicos Acadêmicos , Transtorno Bipolar/terapia , Transtorno Depressivo Maior/terapia , Eletroconvulsoterapia , Convulsões/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
8.
J ECT ; 37(1): 40-45, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32826707

RESUMO

OBJECTIVES: The use of ultrabrief pulse (UBP) stimuli and individual seizure threshold determination have been proposed as ways of minimizing the cognitive side effects of electroconvulsive therapy (ECT), but large samples of patients receiving UBP ECT are lacking. This study reports a retrospective cohort of patients receiving an index course of right unilateral UBP ECT and characterizes the amount of charge required to induce a seizure. METHODS: A single-center retrospective chart review was conducted of adult patients receiving a first lifetime course of ECT using an UBP titration from 2005 to 2017. RESULTS: There were 2328 patients that received a dose titration during the study period, with a mean dose of 21.82 ± 21.61 mC applied to induce a seizure. During the early part of the study period, a mean dose of 18.73 ± 8.99 mC was used, with 28% of patients seizing at a dose of less than 19.2 mC. In the later period, the initial step of dose titration was standardized at 19.2 mC, yielding a mean initial dose to induce a seizure of 22.72 ± 24.00 mC. CONCLUSIONS: Mean seizure thresholds may be lower than reported in previous studies, and a significant proportion of patients may have a seizure threshold lower than the first step of many existing dose titration protocols.


Assuntos
Eletroconvulsoterapia/métodos , Convulsões/etiologia , Adulto , Feminino , Humanos , Masculino , Massachusetts , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
J ECT ; 37(4): 238-242, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33840804

RESUMO

OBJECTIVES: Right unilateral brief pulse (RUL-BP) electroconvulsive therapy (ECT) has been adopted as a technique for reducing the cognitive side effects of ECT relative to sine wave or bilateral treatments, but it is unknown how often patients are transitioned to alternative electrode placements. This study analyzes time in first lifetime acute course RUL-BP ECT. METHODS: A single-center retrospective chart review was conducted of adult patients receiving a first lifetime course of ECT from 2000 to 2017 beginning with individualized seizure threshold determination using RUL-BP treatment parameters. RESULTS: A total of 1383 patients met study criteria and received a mean number of 9.4 ± 3.1 treatments, of which 7.6 ± 3.3 were using RUL-BP stimuli. Only 37.5% of patients were transitioned from RUL to bilateral treatments. Younger patients and those diagnosed with bipolar disorder were more likely to transition from RUL-BP to bilateral treatments, but the overall number of treatments did not differ based on age or primary diagnosis. CONCLUSIONS: Among patients who begin treatment with RUL-BP ECT, more than 60% use exclusively those parameters throughout their acute course.


Assuntos
Transtorno Bipolar , Eletroconvulsoterapia , Adulto , Transtorno Bipolar/psicologia , Transtorno Bipolar/terapia , Duração da Terapia , Eletroconvulsoterapia/efeitos adversos , Eletroconvulsoterapia/métodos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
10.
Psychother Psychosom ; 89(5): 314-319, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32554959

RESUMO

INTRODUCTION: Electroconvulsive therapy (ECT) is a critical procedure in psychiatric treatment, but as typically delivered involves the use of bag-mask ventilation (BMV), which during the COVID-19 pandemic exposes patients and treatment staff to potentially infectious aerosols. OBJECTIVE: To demonstrate the utility of a modified anesthesia protocol for ECT utilizing preoxygenation by facemask and withholding the use of BMV for only those patients who desaturate during the apneic period. METHODS: This chart review study analyzes patients who were treated with ECT using both the traditional and modified anesthesia protocols. RESULTS: A total of 106 patients were analyzed, of whom 51 (48.1%) required BMV using the new protocol. Of clinical factors, only patient BMI was significantly associated with the requirement for BMV. Mean seizure duration reduced from 52.0 ± 22.4 to 46.6 ± 17.1 s, but seizure duration was adequate in all cases. No acute physical, respiratory, or psychiatric complications occurred during treatment. CONCLUSIONS: A modified anesthesia protocol reduces the use of BMV by more than 50%, while retaining adequate seizure duration.


Assuntos
Aerossóis , Anestesia/normas , Protocolos Clínicos/normas , Infecções por Coronavirus/prevenção & controle , Eletroconvulsoterapia/normas , Oxigenoterapia/normas , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Avaliação de Processos em Cuidados de Saúde , Respiração Artificial/normas , Adulto , Índice de Massa Corporal , COVID-19 , Feminino , Humanos , Masculino , Estudos Retrospectivos
11.
J ECT ; 36(4): 229-233, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32453188

RESUMO

OBJECTIVES: Electroconvulsive therapy (ECT) is an effective treatment of depression and other psychiatric conditions. There are few comprehensive data on how many patients receive ECT in the United States or about the demographics of ECT recipients. This study characterizes the demographics of those receiving ECT and how these demographics may have changed with time. METHODS: Freedom of information requests for all data from record keeping inception to January 2019 were sent to the Department of Health or equivalent agency of states that mandate reporting of ECT. Information on demographics and the number of treating facilities was extracted. RESULTS: Data on 62,602 patients receiving treatment in 3 states (California, Illinois, Vermont) were obtained. Overall, 62.3% were women. Fewer than 1% of patients treated were younger than 18 years, whereas 30.3% were 65 years or older. White patients received a disproportionate proportion of treatments, with all other races underrepresented. The total number of facilities offering ECT in the 3 states declined over the study period. CONCLUSIONS: Recipients of ECT are more likely to be female, more likely to be elderly, and more likely to be white than the average person in their state.


Assuntos
Demografia , Eletroconvulsoterapia/tendências , Fatores Etários , California , Etnicidade , Feminino , Humanos , Illinois , Masculino , Vermont
12.
J Arthroplasty ; 34(5): 954-958, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30733073

RESUMO

BACKGROUND: Rheumatoid arthritis patients are at increased risk for periprosthetic joint infection after arthroplasty. The reason is multifactorial. Nasal colonization with Staphylococcus aureus is a modifiable risk factor; carriage rates in RA patients are unknown. The goal of this study is to determine the S aureus nasal carriage rates of RA patients on biologics, RA patients on traditional disease-modifying anti-rheumatic drugs (DMARDs), and osteoarthritis. METHODS: Consecutive patients with RA on biologics (±DMARDs), RA on non-biologic DMARDs, or OA were prospectively enrolled from April 2017 to May 2018. One hundred twenty-three patients were determined necessary per group to show a difference in carriage rates. Patients underwent a nasal swab and answered questions to identify additional risk factors. S aureus positive swabs were further categorized using spa typing. Logistic regression evaluated the association with S aureus colonization between the groups after controlling for known risk factors. RESULTS: RA patients on biologics, 70% of whom were on DMARDs, had statistically significant increase in S aureus colonization (37%) compared to RA on DMARDs alone (24%), or OA (20%) (P = .01 overall). After controlling for glucocorticoids, antibiotic use, recent hospitalization, and diabetes, RA on biologics had a significant increased risk of S aureus nasal colonization (Odds ratio 1.80, 95% confidence interval 1.00-3.22, P = .047). CONCLUSION: S aureus colonization risk was increased for RA on biologics compared to RA not on biologics and OA. Nasal S aureus carriage increases the risk of surgical site infection; this modifiable risk factor should be addressed prior to total joint arthroplasty for this higher risk patient group.


Assuntos
Artrite Reumatoide/tratamento farmacológico , Produtos Biológicos/uso terapêutico , Portador Sadio/tratamento farmacológico , Infecções Estafilocócicas/microbiologia , Staphylococcus aureus/isolamento & purificação , Infecção da Ferida Cirúrgica/microbiologia , Idoso , Antibacterianos/uso terapêutico , Antirreumáticos/uso terapêutico , Artrite Reumatoide/complicações , Artrite Reumatoide/microbiologia , Terapia Biológica , Portador Sadio/microbiologia , Testes Diagnósticos de Rotina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/complicações , Osteoartrite/microbiologia , Osteoartrite/cirurgia , Fatores de Risco , Infecções Estafilocócicas/complicações , Infecções Estafilocócicas/tratamento farmacológico , Infecção da Ferida Cirúrgica/etiologia
13.
J ECT ; 35(2): 133-134, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30308569

RESUMO

Clozapine-induced gastric hypomotility (CIGH) is an underreported, underrecognized effect from high-dose clozapine. In this report, we present a patient with treatment refractory schizophrenia receiving high-dose clozapine who aspirated during general anesthesia for electroconvulsive therapy. To our knowledge, this is the first report of aspiration under general anesthesia as a result of CIGH and highlights the potential dangers high-dose clozapine can pose on patients undergoing electroconvulsive therapy with unrecognized CIGH.


Assuntos
Antipsicóticos/efeitos adversos , Clozapina/efeitos adversos , Eletroconvulsoterapia/efeitos adversos , Pneumonia Aspirativa/etiologia , Anestesia Geral , Antipsicóticos/administração & dosagem , Clozapina/administração & dosagem , Terapia Combinada , Motilidade Gastrointestinal , Humanos , Masculino , Estômago/efeitos dos fármacos , Adulto Jovem
17.
Antimicrob Agents Chemother ; 57(11): 5271-6, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23939898

RESUMO

Voriconazole is more effective for aspergillosis infections with central nervous system involvement than other antifungal agents. The clinical efficacy of voriconazole for central nervous system infections has been attributed to its ability to cross the blood-brain barrier. However, pharmacokinetic studies are limited to plasma and cerebrospinal fluid, so it remains unclear how much of the drug enters the brain. Fluorinated compounds such as voriconazole can be quantified in the brain using fluorine-19 magnetic resonance spectroscopy (MRS). Twelve healthy adult males participated in a pharmacokinetic analysis of voriconazole levels in the brain and plasma. Open-label voriconazole was dosed per clinical protocol with a loading dose of 400 mg every 12 h on day 1, followed by 200 mg every 12 h administered orally over a 3-day period. MRS was performed before and after dosing on the third day. Voriconazole levels in the brain exceeded the MIC for Aspergillus. The brain/plasma ratios were 3.0 at steady state on day 3 (predose) and 1.9 postdose. We found that voriconazole is able to penetrate the brain tissue, which can be quantified using a noninvasive MRS technique. (This study has been registered at ClinicalTrials.gov under registration no. NCT00300677.).


Assuntos
Antifúngicos/farmacocinética , Encéfalo/metabolismo , Pirimidinas/farmacocinética , Triazóis/farmacocinética , Administração Oral , Adulto , Antifúngicos/sangue , Área Sob a Curva , Barreira Hematoencefálica/metabolismo , Esquema de Medicação , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Pirimidinas/sangue , Triazóis/sangue , Voriconazol
18.
Gen Hosp Psychiatry ; 82: 95-100, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37004416

RESUMO

OBJECTIVE: Electroconvulsive therapy (ECT) devices are classified as class II (moderate risk) for the treatment of depressive disorders and catatonia in patients aged 13 and older, but it is unknown how often the treatment is utilized by child and adolescent patients. The aim of this study was to examine the demographics of child and adolescent hospitalizations involving ECT, the medical and psychiatric comorbidities of these hospitalizations, and the overall number of treatments administered per hospitalization. METHOD: The 2019 Kids' Inpatient Database, a national sample of pediatric discharges from 3998 acute care hospitals, was analyzed for hospitalizations involving patients aged 19 and younger receiving ECT based on inpatient procedural codes. RESULTS: 315 (95% confidence interval 275 to 354) discharges among child and adolescent patients, or 0.03% of youth hospitalizations, involved the administration of ECT in the KID in 2019. Hospitalizations in the Northeast, those involving patients residing in ZIP codes in the top income quartile, and those for commercially insured patients had higher odds of ECT administration. Primary discharge diagnoses among ECT recipients were major depressive disorder (143; 46.4%), schizophrenia and other psychotic disorders (71; 23.1%) and bipolar disorder (59; 19.2%). In total 153 (48.6%) of ECT recipients had a coded diagnosis of suicidal ideation. Hospitalizations involved a median of 2 (IQR 1 to 5) ECT treatments before discharge. CONCLUSIONS: ECT is rarely utilized in the inpatient treatment of child and adolescent patients, but is most often administered to patients with mood and psychotic disorders. Commercial insurance and higher income were associated with higher odds of ECT administration, suggesting that access to care may be limited.


Assuntos
Transtorno Depressivo Maior , Eletroconvulsoterapia , Transtornos Psicóticos , Humanos , Criança , Adolescente , Transtorno Depressivo Maior/epidemiologia , Transtorno Depressivo Maior/terapia , Hospitais Gerais , Pacientes Internados
19.
J Affect Disord ; 341: 374-378, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37661058

RESUMO

BACKGROUND: Residual depressive symptoms following treatment are a burden for patients and are associated with increased risk of relapse. While this phenomenon has been explored following pharmacotherapy, there is little research into residual symptoms following electroconvulsive therapy (ECT). This study quantifies the frequency and type of residual symptoms following ECT treatment. METHODS: This study used retrospective data from patients receiving ECT as part of routine clinical care. Depressive symptomatology was assessed using the Quick Inventory of Depressive Symptomatology - Self-Report 16 item scale (QIDS), which includes 9 symptom domains graded from 0 to 3. We quantified the frequency of mild or greater (QIDS≥1) and moderate or greater (QIDS ≥ 2) residual symptoms following treatment among patients responding to ECT (QIDS decrease ≥50 % from baseline) and non-responders (QIDS decrease <50 %). RESULTS: Among 1799 patients, 1015 (56.4 %) responded to ECT and 784 (43.6 %) did not. Among responders, 99.5 % had at least one residual symptom of mild severity or greater (median = 5, IQR = 3-6) and 83.3 % had at least one residual symptom of moderate severity or greater (median = 1, IQR = 1-2). Among non-responders, 100 % had residual symptoms of mild severity or greater (median = 8, IQR = 7-9), and 99.2 % had a residual symptom of moderate severity or greater (median = 4, IQR = 3-5). The most common residual symptoms among both responders and non-responders were sleep disturbances (93.1 % and 98.7 %, respectively) and sadness (68.9 % and 96.4 %, respectively). LIMITATIONS: Retrospective data from a single freestanding psychiatric hospital. CONCLUSION: Among patients with depression receiving ECT, there were high rates of residual symptoms even among patients responding to treatment.


Assuntos
Eletroconvulsoterapia , Humanos , Eletroconvulsoterapia/efeitos adversos , Estudos Retrospectivos , Hospitais Psiquiátricos , Tristeza , Autorrelato
20.
J Affect Disord ; 333: 140-146, 2023 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-37024015

RESUMO

BACKGROUND: Electroconvulsive therapy (ECT) and repetitive transcranial magnetic stimulation (rTMS) are effective neuromodulation therapies for treatment-resistant depression (TRD). While ECT is generally considered the most effective antidepressant, rTMS is less invasive, better tolerated and leads to more durable therapeutic benefits. Both interventions are established device antidepressants, but it remains unknown if they share a common mechanism of action. Here we aimed to compare the brain volumetric changes in patients with TRD after right unilateral (RUL) ECT versus left dorsolateral prefrontal cortex (lDLPFC) rTMS. METHODS: We assessed 32 patients with TRD before the first treatment session and after treatment completion using structural magnetic resonance imaging. Fifteen patients were treated with RUL ECT and seventeen patients received lDLPFC rTMS. RESULTS: Patients receiving RUL ECT, in comparison with patients treated with lDLPFC rTMS, showed a greater volumetric increase in the right striatum, pallidum, medial temporal lobe, anterior insular cortex, anterior midbrain, and subgenual anterior cingulate cortex. However, ECT- or rTMS-induced brain volumetric changes were not associated with the clinical improvement. LIMITATIONS: We evaluated a modest sample size with concurrent pharmacological treatment and without neuromodulation therapies randomization. CONCLUSIONS: Our findings suggest that despite comparable clinical outcomes, only RUL ECT is associated with structural change, while rTMS is not. We hypothesize that structural neuroplasticity and/or neuroinflammation may explain the larger structural changes observed after ECT, whereas neurophysiological plasticity may underlie the rTMS effects. More broadly, our results support the notion that there are multiple therapeutic strategies to move patients from depression to euthymia.


Assuntos
Eletroconvulsoterapia , Humanos , Eletroconvulsoterapia/métodos , Estimulação Magnética Transcraniana/métodos , Depressão/terapia , Giro do Cíngulo , Lobo Temporal , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA