Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Arthroplasty ; 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38823519

RESUMO

INTRODUCTION: The reconstruction of acetabular defects in total hip arthroplasty (THA) can be challenging. An option to treat uncontained acetabular defects is to use modular tantalum augments in combination with cementless press-fit cups. However, modularity is associated with an increased risk of debonding and mechanical failure. In addition, metal wear particles can be released due to micromotions at the implant interface. Clinical data on the long-term results of this treatment strategy is limited. The purposes of this study were: (1) to evaluate the clinical and radiological outcome of complex THA using modular trabecular metal augments and uncemented revision cups; (2) to investigate the blood tantalum concentrations in these patients at mid-term (mean 4.5 year) follow-up; and (3) to report complications and mechanisms of failure related to this procedure. MATERIALS AND METHODS: In this single-center study, we retrospectively reviewed data from a consecutive cohort of 27 patients who underwent complex acetabular defect reconstruction using a modular tantalum acetabular augment in combination with an uncemented tantalum cup. We evaluated the implant survival, and the radiological and clinical outcomes after a mean follow-up of 4.5 years (SD 2.1; range 2.5 to 10.6 years) using patient-reported outcome scores (PROMs). Blood samples were analyzed regarding tantalum concentration and compared with a control group. RESULTS: The cumulative survival rate at 4.5 years with the endpoint "revision of the acetabular component for aseptic loosening" was 94.4% (95% confidence interval (CI) 71.6 to 99.2) and 82.9% (95 % CI 60.5 to 93.3) for the endpoint "revision for any reason." The PROMs improved significantly up to the latest follow-up, and radiographic data showed no signs of loosening or implant migration. Median blood tantalum concentrations were significantly higher in the study group (0.15 µg/L) compared to the control group (0.002 µg/L) (P < 0.001). CONCLUSIONS: This study demonstrated acceptable clinical and radiological results of cementless revision THA using modular trabecular metal implants for the reconstruction of large acetabular defects. Tantalum concentrations were significantly higher in patients who had tantalum implants compared to the control group, however, the systemic and local effects of an increased tantalum exposure are not yet fully understood and have to be further investigated.

2.
BMC Musculoskelet Disord ; 21(1): 191, 2020 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-32220253

RESUMO

BACKGROUND: The arthroscopic method offers a less invasive technique of Bankart repair for traumatic anterior shoulder instability. The aim of the study is to determine the mid-/long-term functional outcome, failure rates and predictors of failure after primary arthroscopic Bankart repair for traumatic anterior shoulder instability. METHODS: A total of 100 patients were primarily operated using arthroscopic Bankart repair after traumatic anterior shoulder instability. Medical records were retrospectively reviewed, and patients were assessed using postal questionnaire after a mean follow-up of 8.3 years [3-14]. Clinical assessment was performed using Constant score, Rowe score, and American Shoulder and Elbow Surgeons score. RESULTS: The overall recurrence rate was 22%. The Kaplan-Meier failure-free survival estimates. were 80% at 5 years and 70% at 10 years. Nearly half (54.5%) of recurrences occurred at 2 years postoperative. Compared with normal shoulder, there were statistical differences in all 3 scores. Failure rate was significantly affected by age at the time of surgery with 86% of recurrence cases observed in patients aged 30 years or younger. Nevertheless, Younger age at the time of surgery (P = 0.007) as well age at the time of initial instability (P = 0.03) was found to correlate negatively with early recurrence within 2 years of surgery. Among those with recurrent instability, recurrence rate was found to be higher if there had been more than 5 instability episodes preoperatively (P = 0.01). Return to the preinjury sport and occupational level was possible in 41 and 78%, respectively. CONCLUSION: Failure-free survival rates dropped dramatically over time. Alternative reconstruction techniques should be considered in those aged ≤30 years due to the high recurrence rate.


Assuntos
Artroscopia/efeitos adversos , Lesões de Bankart/cirurgia , Instabilidade Articular/cirurgia , Luxação do Ombro/cirurgia , Âncoras de Sutura/efeitos adversos , Adolescente , Adulto , Artroscopia/métodos , Lesões de Bankart/complicações , Feminino , Seguimentos , Humanos , Instabilidade Articular/diagnóstico , Instabilidade Articular/epidemiologia , Instabilidade Articular/etiologia , Masculino , Amplitude de Movimento Articular , Recidiva , Estudos Retrospectivos , Luxação do Ombro/diagnóstico , Luxação do Ombro/epidemiologia , Luxação do Ombro/etiologia , Lesões do Ombro , Articulação do Ombro/cirurgia , Inquéritos e Questionários/estatística & dados numéricos , Falha de Tratamento , Adulto Jovem
3.
Knee Surg Sports Traumatol Arthrosc ; 27(5): 1658-1664, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30465099

RESUMO

PURPOSE: Whether unicompartimental or total knee arthroplasty is superior for treatment of anteromedial knee osteoarthritis, is still uncertain. Therefore, the purpose of this study was to evaluate clinical and radiological outcome as well as long-term survivorship of medial Oxford unicompartmental knee arthroplasty (OUKA) at an independent center with a minimum follow-up of 10 years. METHODS: This single-center retrospective cohort study reports the 10-15 years follow-up results of 113 consecutive patients (126 knees) after medial OUKA. Survivorship analysis was performed with several different endpoints and clinical outcome was measured using the Oxford Knee Score (OKS), American Knee Society Score (AKSS-O), range of motion (ROM), Tegner activity score and UCLA score. Radiological analysis was performed with focus on progression of arthritis in the lateral compartment. RESULTS: A total of 16 patients (16 knees) underwent revision surgery resulting in a survival rate of 92.4% at 10 years and 88.6% at 15 years with the endpoint device-related revisions. The main reason for revision surgery was progression of arthritis in five patients (31.3%) followed by persistency of pain in three patients (18.7%). Clinical outcome was good to excellent with an OKS of 39.9 at 11 years, an AKSS-O of 89.3 and a mean range of motion of 122°. The radiological analysis revealed a significant progression of degenerative changes in the lateral compartment, however without any impact on the functional outcome. CONCLUSION: Oxford UKA of the medial compartment ensures good long-term survivorship with an excellent functional outcome. Therefore, the results of this study support the continued use of OUKA in patients with anteromedial osteoarthritis. LEVEL OF EVIDENCE: Retrospective cohort study, Level III.


Assuntos
Artroplastia do Joelho/métodos , Prótese do Joelho , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Osteoartrite do Joelho/cirurgia , Falha de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Progressão da Doença , Feminino , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Dor/cirurgia , Amplitude de Movimento Articular , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
4.
Knee ; 34: 34-41, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34875496

RESUMO

BACKGROUND: The indications and outcomes of semi- or fully-constrained knee implants in primary total knee arthroplasty (TKA) are still controversially discussed. The present study aims to evaluate the mid-term results and complications of a modular/non-modular rotating-hinge implant in complex primary TKA. METHODS: Eighty-two patients (86 knees) following primary TKA were retrospectively evaluated with a mean follow-up of 63 months. The functional outcome was assessed using the American Knee Society Score (AKSS) and the Oxford Knee Score (OKS). A Visual Analog Scale (VAS) was used to determine pain levels. Implant survival and reoperation rateswere estimated using competing risk analysis. Cox regression analysis wasperformed to evaluate the influence of modularity on implant survival. RESULTS: The survival rate with the endpoint implant revision was 90% (95 %CI:83-98%) and the survival rate with the endpoint all reoperations was 84% (95 %CI:75-94%) at 7 years. The AKSS improved significantly from 24 (SD 14.9, range:0-69) preoperatively to 83 (SD 14.3, range:57-100) postoperatively (p < 0.001); functional AKSS improved significantly from 27 (SD 24.3, range:0-100) to 46 (SD: 32.9, range 0-100) (p = 0.003), and OKS from 19 (SD: 8.3, range:5-43) to 29 (SD: 10.7, range:6-48), respectively (p < 0.0001). VAS decreased significantly from 8 (SD: 2.6, range:0-10) preoperatively to 3 (SD: 2.9, range:0-9) postoperatively (p < 0.0001). There was no significant influence of modularity on revision rates comparing modular to non-modular implants (p = 0.072). CONCLUSIONS: The present rotating-hinge implant provides substantial improvement in function and reduction of pain with good implant survival in the mid-term. Modularity was not associated with higher rates of revision.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Humanos , Articulação do Joelho/cirurgia , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
5.
Medicine (Baltimore) ; 101(17): e29230, 2022 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-35512083

RESUMO

ABSTRACT: The goniometer is the gold-standard measurement tool of ankle range of motion (ROM). However, several studies have questioned its inter- and intra-rater reliability. Therefore, we conducted this validation study to assess the reliability of a different tool, named Equinometer, as a measurement device of ankle ROM in addition to comparing the reproducibility of their results.Sixteen healthy individuals were included. They underwent both goniometer and Equinometer measurements in knee extension and 90° knee flexion (Silfverskjöld Test). Three raters reported the values of dorsiflexion (DF) and plantarflexion (PF) in each session using both measurement tools. Intra-rater reliability was assessed between 2 raters on another study group of 24 participants. Intraclass correlation coefficients were used to determine the reliability of the used device.The age of study subjects ranged from 22 to 85 years. Fifty percent were males, and the right ankle joint was the most examined side (68.75%). In terms of DF and PF during knee extension and flexion, our analysis revealed that the measurements recorded by the Equinometer were equivalent to the goniometer. Of note, the intra-rater reliability of the Equinometer was excellent for both DF and PF assessment during both knee flexion and extension (Intraclass correlation coefficient ranged from 0.90 to 0.98), with minimal mean differences from goniometer measurements. Subgroup analysis based on age did not reveal any significant differences (P > .05).Given the high intra-rater correlations of the Equinometer, we suggest that it is reliable and precise in recording ankle ROM in outpatient clinics, particularly to obtain reproductive, comparable and unbiased data from different observers.


Assuntos
Articulação do Tornozelo , Paralisia Cerebral , Adulto , Idoso , Idoso de 80 Anos ou mais , Tornozelo , Paralisia Cerebral/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Reprodutibilidade dos Testes , Adulto Jovem
6.
Orthop Traumatol Surg Res ; 107(4): 102896, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33753266

RESUMO

INTRODUCTION: The objective of this prospective cohort study was the assessment of short-term outcome results of shoulder hemiarthroplasty (HA) using pyrolytic carbon (PC) heads. PC has been introduced as a new material to avoid surgical revision due to glenoid erosion after HA. Glenoid erosion due to the use of metallic heads is known to reduce durability. HYPOTHESIS: HA using PC heads shows comparable or better radiographic and clinical outcome compared to the conventional HA using metallic heads in the short-term. PATIENTS AND METHODS: This study was conducted as a single center prospective cohort follow-up study including a total number of 16 consecutive HA with PC heads. Inclusion criteria were indication for HA, an intact rotator cuff, no proximal humeral fractures in patient's history and age>18years. Mean age at the time of arthroplasty was 52.8±10.8years. The mean follow-up was 24.3±8.1months. Baseline and follow-up Numeric Rating Scale (NRS), Constant Scores (CS), Range of Motion (ROM) and radiographs were assessed. RESULTS: At a mean follow-up of 24.3months the mean CS (p<0.001), mean NRS (p<0.001) and mean ROM (p<0.05) improved statistically significant. Subgroup analysis revealed no differences between subgroups (sex, age, diagnosis, and handedness). Survival rate was high (94.1%). One periprosthetic fracture occurred as the only complication during follow-up. Radiographs showed glenoid erosion in one case and subacromial space reduction in two cases. DISCUSSION: PC heads in HA show satisfying short-term results at a mean follow-up of two years, which are comparable to those of conventional HA. The clinical improvements were highly significant with good implant survival. However, long-term follow-up results are necessary, especially compared to conventional HA. LEVEL OF EVIDENCE: IV; observational therapeutic cohort study.


Assuntos
Artroplastia do Ombro , Hemiartroplastia , Articulação do Ombro , Adolescente , Carbono , Estudos de Coortes , Seguimentos , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Amplitude de Movimento Articular , Reoperação , Ombro , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Resultado do Tratamento
7.
Orthop Traumatol Surg Res ; 106(1): 39-44, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31837929

RESUMO

BACKGROUND: Massive irreparable posterosuperior rotator cuff tears may result in a loss of external rotation. Most of these patients lose their ability to perform activities of daily living (ADLs), especially where external rotation and abduction are needed. Latissimus dorsi tendon transfer (LDTT) is a method to restore abduction and external rotation in patients with posterosuperior rotator cuff tears. There are no objective data concerning whether LDTT can restore range of motion (ROM), especially in performing ADLs and if proprioception changes after LDTT. METHODS: We examined 12 patients 4.2 years (1-9 years) after LDTT with simultaneous 3D motion analysis; the opposite, nonaffected side was assessed as control. The measurement protocol included maximum values in flexion/extension, abduction/adduction, internal/external rotation in 0° and in 90° flexion and in 90° abduction. To evaluate competences, we measured seven activities of daily life and examined the proprioceptive ability using an active angle reproduction test. RESULTS: In total, 4.2 years (1-9 years) after LDTT there was no significant difference in flexion/extension and abduction/adduction compared to the healthy side. Maximum external rotation was significantly reduced compared to the opposite side. Eleven patients (85%) were able to perform all ADL. Proprioceptive ability did not differ from the healthy side. CONCLUSION: LDTT cannot fully restore a patient's ability for external rotation after a posterosuperior rotator cuff tear. However, 4.2 years after surgery, 85% of the patients are able to perform all ADLs. Proprioceptive ability is not affected by the transfer.


Assuntos
Atividades Cotidianas , Propriocepção , Amplitude de Movimento Articular , Lesões do Manguito Rotador , Músculos Superficiais do Dorso , Transferência Tendinosa , Humanos , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Resultado do Tratamento
8.
J Clin Med ; 9(2)2020 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-32033373

RESUMO

Background: Massive irreparable posterosuperior rotator cuff tears may result in the loss of external rotation. Most of the patients with posterosuperior rotator cuff tears suffer from a restriction in their daily life actions. Latissimus dorsi tendon transfer (LDTT) is a method to restore abduction and external rotation in these patients. However, the behavior of the LD after the transfer is not clear yet. Few studies have analyzed the activity of the LD after transfer. The goal of this study was to examine the function of the LD postoperatively in follow-up examinations during activities of daily life (ADLs) and during different movements evaluated by measuring the range of motion (ROM). Methods: We examined 12 patients 4.3 years (1-9 years) after LDTT, using simultaneous 3D motion analysis and surface Electromyography (sEMG) of 12 muscle parts; the opposite, nonaffected side was assessed as a control. The measurement protocol included two standardized movements (exorotation with an adducted arm and exorotation with 90° abduction) as well as two ADLs (combing hair and perineal care). Results: An average of 4.3 years (1-9 years) after LDTT, 9 of the 12 subjects showed EMG activity in the transferred LD during glenohumeral external rotation. During the endorotation phase, either little activity was registered or only the pectoralis major was active. During the ADLs, 6 out of 12 subjects showed EMG activity in the transferred LD while "combing hair", whereas all subjects showed EMG activity during perineal care. Conclusion: The LD showed partial activity in its new role as an exorotator, but no clear difference was observed between some of the movements as well as in comparison with the healthy shoulder. Further studies will need to be conducted to better differentiate voluntary contractions and co-contractions as well as tension and extension in the muscle.

9.
Strategies Trauma Limb Reconstr ; 13(3): 163-170, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30392178

RESUMO

Surgical treatment of benign and low-grade malignant intramedullary chondroid lesions at the distal femur is not well analyzed compared to higher-grade chondrosarcomas. Localization at the distal femur offers high biomechanical risks requiring sophisticated treatment strategy, but scientific guidelines are missing. We therefore wanted to analyze a series of equally treated patients with intralesional resection and bone cement filling with and without additional osteosynthesis. Twenty-two consecutive patients could be included with intralesional excision and filling with polymethylmethacrylate bone cement alone (n = 10) or with compound bone cement osteosynthesis using a locking compression plate (n = 12). Clinical and radiological outcome was retrospectively evaluated including tumor recurrences, complications, satisfaction, pain, and function. Mean follow-up was 55 months (range 7-159 months). Complication rate was generally high with lesion-associated fractures both in the osteosynthesis group (n = 2) and in the non-osteosynthesis group (n = 2). All fractures occurred in lesions that reached the diaphysis. No fractures were found in meta-epiphyseal lesions. No tumor recurrence was found until final follow-up. Clinical outcome was good to excellent for both groups, but patients with additional osteosynthesis had significantly longer surgery time, more blood loss, longer postoperative stay in the hospital, more complications, more pain, less satisfaction, and worse functional outcome. Intralesional resection strategy was oncologically safe without local recurrences but revealed high risk of biomechanical complications if the lesion reached the diaphysis with an equal fracture rate no matter whether osteosynthesis was used or not. Additional osteosynthesis significantly worsened final clinical outcome and had more overall complications. This study may help guide surgeons to avoid overtreatment with additional osteosynthesis after curettage and bone cement filling of intramedullary lesions of the distal femur. Meta-epiphyseal lesions will need additional osteosynthesis rarely, contrary to diaphyseal lesions with considerable cortical thinning.

10.
J Orthop ; 15(2): 349-353, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29881151

RESUMO

PURPOSE: The aim of the study was to examine clinical and radiographic results of a cementless humeral surface and to evaluate prognostic parameters for implant failure. METHODS: 34 shoulders were examined preoperatively and after a mean 2.7 years. Radiographic parameters, Constant scores (CS) and complications were recorded. RESULTS: The mean CS improved from 27 to 51 points. Eight patients (24%) had an implant revision for secondary glenoid erosion. In the revision group was an increase of the LGHO of 8.4%. CONCLUSIONS: The study shows a high revision-rate (24%). Predictor for an implant failure was an operative changing of the LGHO.

11.
J Orthop ; 14(4): 577-581, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28970669

RESUMO

BACKGROUND: Reverse total shoulder arthroplasty (RSA) can improve function in cuff tear arthropathy (CTA) shoulders, but limited data are available on the effect of RSA on proprioception. The purpose of this study was the evaluation of the proprioception after RSA. METHOD: This study included fifteen consecutive patients (n = 15) who received an RSA. We measured an active angle reproduction (AAR) by a novel 3D motion analysis using the Heidelberg upper extremity model (HUX). RESULTS: The overall proprioception didn't change significantly from 6.2° preoperatively to 6.2° postoperatively. CONCLUSION: We conclude that, the overall proprioception remained the same or deteriorated for different movements.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA