Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Catheter Cardiovasc Interv ; 98(3): E444-E452, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33502784

RESUMO

OBJECTIVES: To determine whether a permanent pacemaker (PPM) in situ can enhance survival after transcatheter aortic valve implantation (TAVI), in a predominantly inoperable or high risk cohort. BACKGROUND: New conduction disturbances are the most frequent complication of TAVI, often necessitating PPM implantation before hospital discharge. METHODS: We performed an observational cohort analysis of the UK TAVI registry (2007-2015). Primary and secondary endpoints were 30-day post-discharge all-cause mortality and long-term survival, respectively. RESULTS: Of 8,651 procedures, 6,815 complete datasets were analyzed. A PPM at hospital discharge, irrespective of when implantation occurred (PPM 1.68% [22/1309] vs. no PPM 1.47% [81/5506], odds ratio [OR] 1.14, 95% confidence interval [CI] 0.71-1.84; p = .58), or a PPM implanted peri- or post-TAVI only (PPM 1.44% [11/763] vs. no PPM 1.47% [81/5506], OR 0.98 [0.51-1.85]; p = .95) did not significantly reduce the primary endpoint. Patients with a PPM at discharge were older, male, had right bundle branch block at baseline, were more likely to have received a first-generation self-expandable prosthesis and had experienced more peri- and post-procedural complications including bailout valve-in-valve rescue, bleeding and acute kidney injury. A Cox proportional hazards model demonstrated significantly reduced long-term survival in all those with a PPM, irrespective of implantation timing (hazard ratio [HR] 1.14 [1.02-1.26]; p = .019) and those receiving a PPM only at the time of TAVI (HR 1.15 [1.02-1.31]; p = .032). The reasons underlying this observation warrant further investigation. CONCLUSIONS: A PPM did not confer a survival advantage in the first 30 days after hospital discharge following TAVI.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Assistência ao Convalescente , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Masculino , Alta do Paciente , Complicações Pós-Operatórias , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 89(4): 783-786, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27726292

RESUMO

INTRODUCTION AND METHOD: Transcatheter aortic valve implantation (TAVI) and balloon aortic valvuloplasty (BAV) are now well established percutaneous procedures. These procedures almost always require bursts of rapid ventricular pacing to temporarily reduce cardiac output to facilitate the procedure, usually done via a temporary pacing wire inserted into the right ventricle. We describe a case series of 132 cases of TAVI and 76 BAV done using ventricular pacing via the left ventricular lead by simply connecting one electrode to the patient's skin and one electrode through the left ventricular (LV) wire. RESULTS: All of the 132 TAVI cases (a mixture of Edwards Sapien, Medtronic CoreValve and Boston Scientific Lotus) and 76 BAV were successfully performed using pacing through the LV wire. No BAV patients required temporary pacing wire (TPW) or permanent pacemaker (PPM) insertion. Of the TAVI patients, 6 (4.5%) required TPW during the procedure due to complete heart block to facilitate removal of the LV wire. 1 patient (0.8%) required a PPM urgently due to complete heart block and haemodynamic instability. Twenty eight Patients (21.2%) required PPM following TAVI, 9 of which were within the first 24 hr. Average time to pacemaker implantation was 3.7 days. CONCLUSION: Rapid ventricular pacing via the LV wire is a simple, safe and effective strategy for percutaneous aortic valve intervention and balloon aortic valvuloplasty. It eliminates the need for a temporary pacing wire with its attendant risks in the vast majority of cases. Furthermore, most pacemakers following TAVI are required late, after the first 24 hr period, by which time the TPW has already usually been removed. © 2016 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/métodos , Bloqueio Cardíaco/prevenção & controle , Ventrículos do Coração/fisiopatologia , Marca-Passo Artificial , Complicações Pós-Operatórias/prevenção & controle , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Débito Cardíaco/fisiologia , Feminino , Bloqueio Cardíaco/etiologia , Frequência Cardíaca/fisiologia , Próteses Valvulares Cardíacas , Humanos , Período Intraoperatório , Masculino , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Resultado do Tratamento
3.
Front Cardiovasc Med ; 11: 1357006, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38404723

RESUMO

Introduction: Assessing filling pressure (FP) remains a clinical challenge despite advancements in non-invasive imaging techniques. This study investigates the utility of echocardiographic left ventricular (LV) to left atrial (LA) volume ratio in estimating the resting FP in patients with dyspnoea and preserved ejection fraction (EF). Methods: This study is a prospective, single-centre analysis of 53 consecutive patients with dyspnoea (New York Heart Association grade 2 or 3) and LVEF of ≥50% (mean age 71 ± 10 years) who underwent cardiac catheterisation, including direct measurement of LA pressure at rest using retrograde technique. Echocardiographic data were obtained 1.5 ± 1.0 h after cardiac catheterisation. The patients were divided into two groups: Group 1 consisted of individuals with elevated FP, indicated by a mean LA pressure or mean pulmonary capillary wedge pressure of >12 mmHg, and Group 2 comprised of patients with normal FP. The LV and LA volumes were measured at three specific points: the minimum volume (LVES, LAmin), the volume during diastasis (LVdias, LAdias), and the maximum volume (LVED, LAmax). The corresponding LV/LA volume ratios were analysed: end-systole (LVES/LAmax), diastasis (LVdias/LAdias), and end-diastole (LVED/LAmin). Results: The patients in Group 1 exhibited lower LV/LA volume ratios compared with those in Group 2 (LVES/LAmax 0.44 ± 0.12 vs. 0.60 ± 0.23, P = 0.0032; LVdias/LAdias 1.13 ± 0.30 vs. 1.56 ± 0.49, P = 0.0007; LVED/LAmin 2.71 ± 1.57 vs. 4.44 ± 1.70, P = 0.0004). The LV/LA volume ratios correlated inversely with an increased FP (LVES/LAmax, r = -0.40, P = 0.0033; LVdias/LAdias, r = -0.45, P = 0.0007; LVED/LAmin, r = -0.55, P < 0.0001). Among all the measurements, the LVdias/LAdias ratio demonstrated the highest discriminatory power to distinguish patients with elevated FP from normal FP, with a cut-off value of ≤1.24 [area under the curve (AUC) = 0.822] for the entire group, encompassing both sinus rhythm and atrial fibrillation. For patients in sinus rhythm specifically, the cut-off value was ≤1.28 (AUC = 0.799), with P < 0.0001 for both. The LVdias/LAdias index demonstrated non-inferiority to the E/e' ratio [ΔAUC = 0.159, confidence interval (CI) = -0.020-0.338; P = 0.0809], while surpassing the indices of LA reservoir function (ΔAUC = 0.249, CI = 0.044-0.454; P = 0.0176), LA reservoir strain (ΔAUC = 0.333, CI = 0.149-0.517; P = 0.0004), and LAmax index (ΔAUC = 0.224, CI = 0.043-0.406; P = 0.0152) in diagnosing patients with elevated FP. Conclusion: The study presents a straightforward and reproducible method for non-invasive estimation of FP using routine TTE in patients with dyspnoea and preserved EF. The LVdias/LAdias index emerges as a promising indicator for identifying elevated FP, demonstrating comparable or even superior performance to established parameters.

4.
Ann Thorac Surg ; 103(4): e305-e307, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28359483

RESUMO

Transcatheter aortic valve implantation (TAVI) has become the standard treatment for aortic stenosis in high-risk patients. TAVI for native valve aortic regurgitation is technically more demanding because of a lack of anchoring calcification, a lower index incidence, heterogeneous causes, and larger anatomy. We present 3 cases in which the Lotus TAV was used to treat severe native aortic regurgitation (AR) successfully.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Feminino , Humanos , Masculino
5.
Int J Cardiol ; 245: 99-104, 2017 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-28778466

RESUMO

INTRODUCTION: Safety and efficacy data on patent foramen ovale (PFO) closure with the Occlutech Figulla Flex II device are lacking. We undertook a fully monitored prospective Registry on PFO closure using this device. METHODS: 100 patients undergoing PFO closure were enrolled into the OPPOSE Registry at 6 UK centres. The primary endpoint was PFO closure (grade 0 or 1 shunt) at 6-month BCTTE assessed by Corelab. Secondary endpoints included implantation success, complications, and atrial fibrillation during follow-up. RESULTS: 100 patients aged 43.8±11.5years, 53% male, were recruited. Indications for PFO closure included stroke (56%), TIA (29%) systemic embolism (4%) and MI (3%). Closure was undertaken under GA (44%) or LA (56%), with TOE (45%), ICE (31%), no imaging (20%) or TTE (3%). Balloon sizing was used in 98% of cases and showed a tunnel length of 7.3±3.6mm, primum-secundum separation of 7.0±2.9mm and basal inlet width of 8.5±3.5mm. Implantation was successful in all cases using 18mm (9%), 25mm (80%), 30mm (10%) and 35mm (1%) devices. 5 patients were lost to follow-up. 92 patients underwent six-month BCTTE. The primary endpoint of PFO closure (grade 0 or 1 shunt) at six months was 79.3%. One patient developed major bleeding (BARC 3b), one patient required vascular surgery, and in one patient device embolization was noted at six months and a larger device implanted. There was one case of new atrial fibrillation. CONCLUSIONS: This first prospective monitored data for the Occlutech Figulla Flex II device demonstrates good safety and efficacy data at implant and six-month follow-up.


Assuntos
Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/cirurgia , Sistema de Registros , Dispositivo para Oclusão Septal/tendências , Adulto , Ecocardiografia Transesofagiana/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Dispositivo para Oclusão Septal/efeitos adversos , Dispositivo para Oclusão Septal/normas , Resultado do Tratamento
6.
JACC Cardiovasc Interv ; 10(12): 1247-1253, 2017 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-28641846

RESUMO

OBJECTIVES: The authors report the incidence of pacemaker implantation up to hospital discharge and the factors influencing pacing rate following implantation of the LOTUS bioprosthesis (Boston Scientific, Natick, Massachusetts) in the United Kingdom. BACKGROUND: Transcatheter aortic valve replacement (TAVR) is associated with a significant need for permanent pacemaker implantation. Pacing rates vary according to the device used. The REPRISE II (Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus Valve System) trial reported a pacing rate of 29% at 30 days after implantation of the LOTUS device. METHODS: Data were collected retrospectively on 228 patients who had the LOTUS device implanted between March 2013 and February 2015 across 10 centers in the United Kingdom. Twenty-seven patients (12%) had pacemakers implanted pre-procedure and were excluded from the analysis. RESULTS: Patients were aged 81.2 ± 7.7 years; 50.7% were male. The mean pre-procedural QRS duration was 101.7 ± 20.4 ms. More than one-half of the cohort (n = 111, 55%) developed new left bundle branch block (LBBB) following the procedure. Permanent pacemakers were implanted in 64 patients (32%) with a median time to insertion of 3.0 ± 3.4 days. Chief indications for pacing were atrioventricular (AV) block (n = 46, 72%), or LBBB with 1st degree AV block (n = 11, 17%). Amongst those who received a pacemaker following TAVR the pre-procedural electrocardiogram findings included: No conduction disturbance (n = 41, 64%); 1st degree AV block (n = 10, 16%); right bundle branch block (n = 6, 9%) and LBBB (n = 5, 8%). LBBB (but not permanent pacemaker) occurred more frequently in patients who had balloon aortic valvuloplasty before TAVR (odds ratio [OR]: 1.25; p = 0.03). Pre-procedural conduction abnormality (composite of 1st degree AV block, hemiblock, right bundle branch block, LBBB) was independently associated with the need for permanent pacemaker (OR: 2.54; p = 0.048). The absence of aortic valve calcification was also associated with a higher pacing rate (OR: 0.55; p = 0.031). Multivariate regression analysis did not show an independent association between depth of implant, valve oversizing, balloon post-dilatation, and the need for pacing post-procedure. CONCLUSIONS: Following implantation of the repositionable LOTUS valve, 55% of patients developed LBBB and 32% of patients required a pacemaker during their index hospital admission. Patients with pre-procedural conduction disturbance and non-calcified aortic valves were more likely to need pacing. No other anatomic features were identified with increased pacing requirement with the LOTUS device.


Assuntos
Bloqueio Atrioventricular/terapia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial , Sistema de Condução Cardíaco/fisiopatologia , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter/efeitos adversos , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/fisiopatologia , Valvuloplastia com Balão , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/fisiopatologia , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Reino Unido
7.
Int J Cardiovasc Imaging ; 29(5): 1121-7, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23283562

RESUMO

Cardiac CT myocardial perfusion is an emerging tool utilizing differences in myocardial density of ischemic compared to normal myocardium. We sought to document the contrast enhanced density profile of myocardial segments subtended by severely stenotic coronary arteries on rest (non stress) cardiac CT imaging, and compare the density with identical segments without ischemic disease. 100 cardiac CT studies were identified resulting in 25 normal patients, 37 with severe left anterior descending artery stenosis, 14 with severe left circumflex artery stenosis, and 24 with severe right coronary artery stenosis. The studies were reviewed on a workstation with dedicated myocardial analysis software. Left anterior descending artery ischemic segments (apical anterior and apical septal) measured 82.2 (±3) and 102 (±3) Hounsfield unit (HU) respectively comparing with non-ischemic segments 89 (±4) and 109 (±4) HU respectively (both P values 0.16). Left circumflex artery segments (basal anterolateral and mid anterolateral) demonstrated 80 (±4) and 76 (±4) HU respectively compared to non-ischemic segments, 89 (±4) and 87 (±4) HU (P value 0.13 and 0.07 respectively). Right coronary artery ischemic segments (basal inferoseptal and basal inferior) measured 104 (±3) and 105 (±3) HU respectively and these compared with non-ischemic segments, 102 (±4) and 105 (±4) HU respectively (P Value 0.69 and 0.94 respectively). Comparison of ischemic myocardial segments with non-ischemic segments demonstrated no significant difference in myocardial density. In prospectively acquired resting 320 multi detector CT, the myocardium subtended by severely stenotic vessels demonstrates no significant density difference compared with those supplied by vessels with no stenosis, confirming that myocardial ischaemia cannot be reliably detected on rest coronary computed tomography angiography by qualitative nor quantitative assessment.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Imagem de Perfusão do Miocárdio/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Software , Automação Laboratorial , Circulação Coronária , Estenose Coronária/fisiopatologia , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
9.
J Cardiothorac Surg ; 2: 43, 2007 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-17956619

RESUMO

BACKGROUND: To examine whether augmentation index (AIx) is increased in Marfan syndrome (MFS) and associated with increased aortic root size, and whether a peripheral-to-central generalised transfer function (GTF) can be applied usefully in MFS. METHODS: 10 MFS patients and 10 healthy controls (matched for sex, age and height) were studied before and after 400 microg sub-lingual GTN. Arterial waveforms were recorded using applanation tonometry. AIx and pulse pressure (PP) were determined for the radial and carotid arteries. Pulse wave velocity (PWV) was measured between carotid and femoral arteries. GTFs were generated to examine the relationship between radial and carotid waveforms. RESULTS: AIx was greater in MFS compared to controls at radial (mean -31.4 (SD 14.3)% v -50.2(15.6)%, p = 0.003) and carotid (-7.6(11.2)% v -23.7(12.7)%, p = 0.004) sites. Baseline PP at all measurement sites, and PWV, did not differ between subject groups. Multivariate analysis demonstrated that PWV and carotid AIx were positively correlated with aortic root size (p < 0.001 and p = 0.012 respectively), independent of the presence of MFS. PP was not associated with aortic root size. GTN caused similar decreases in AIx in both controls and patients. Significant differences were found in GTFs between MFS and control subjects, which changed following GTN administration. However, when an independent GTF was used to derive carotid waves from radial waves, no differences were found in the degree of error between MFS and controls. CONCLUSION: AIx is sensitive to the vascular abnormalities present in MFS, and may have a role as an adjunct to measurement of central PP and PWV. Differences between MFS and controls in the nature of the peripheral-to-central GTF are present, although have little effect on the pulse contour.


Assuntos
Manometria/métodos , Síndrome de Marfan/fisiopatologia , Adolescente , Adulto , Pressão Sanguínea/efeitos dos fármacos , Artérias Carótidas/efeitos dos fármacos , Artérias Carótidas/fisiopatologia , Estudos de Casos e Controles , Ecocardiografia , Elasticidade/efeitos dos fármacos , Feminino , Análise de Fourier , Humanos , Masculino , Pessoa de Meia-Idade , Nitroglicerina/farmacologia , Fluxo Pulsátil , Seio Aórtico/diagnóstico por imagem , Seio Aórtico/efeitos dos fármacos , Seio Aórtico/patologia , Vasodilatadores/farmacologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA