Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Pediatr Orthop ; 44(3): e267-e277, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38145389

RESUMO

BACKGROUND: This prospective study was undertaken to report outcomes following reconstructive surgery for patients with painful pediatric idiopathic flexible flatfoot. METHODS: Twenty-five patients with pediatric idiopathic flexible flatfoot were evaluated pre- and post flatfoot reconstruction with lateral column lengthening (LCL). All patients had lengthening of the Achilles or gastrocnemius, while 13 patients had medial side soft tissue (MSST) procedures, 7 underwent medial cuneiform plantarflexion osteotomy (MCPO), and 5 had medializing calcaneal osteotomy. Measures of static foot alignment-both radiographic parameters and clinical arch height indices-were compared, as were measures of dynamic foot alignment and loading, including arch height flexibility and pedobarography. Preoperative and postoperative patient-reported outcome (PRO) scores were compared between those treated with or without MSST procedures. RESULTS: The median subject age was 13.8 years (range: 10.3 to 16.5) at the time of surgery. All radiographic parameters improved with surgery ( P <0.001). The mean sitting arch height index showed a modest increase after surgery ( P =0.023). Arch height flexibility was similar after surgery. The mean center-of-pressure excursion index increased from 14.1% to 24.0% ( P <0.001), and the mean first metatarsal head (MH) peak pressure dropped ( P <0.001), while the mean fifth MH peak pressure increased ( P =0.018). The ratio of peak pressure in the fifth MH to peak pressure in the second MH increased ( P =0.010). The ratio of peak pressure in the first MH to peak pressure in the second MH decreased when an MCPO was not used ( P <0.002), but it remained stable when an MCPO was included. Mean scores in all PRO domains improved ( P <0.001). Patients treated without MSST procedures showed no difference in PROMIS Pain Interference scores compared to those without MSST procedures. CONCLUSIONS: Flatfoot reconstruction surgery using an LCL with plantarflexor lengthening results in improved PROs. LCL changes but does not normalize the distribution of MH pressure loading. The addition of an MCPO can prevent a significant reduction in load-sharing by the first MH.


Assuntos
Calcâneo , Pé Chato , Humanos , Criança , Adolescente , Pé Chato/cirurgia , Calcâneo/cirurgia , Estudos Prospectivos , Dor , Medidas de Resultados Relatados pelo Paciente
2.
J Pediatr Orthop ; 44(6): 366-372, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38595095

RESUMO

OBJECTIVE: Severe spinal deformity results in restrictive pulmonary disease from thoracic distortions and lung-volume limitations. Though spirometry and body plethysmography are widely accepted tests for pulmonary function tests (PFTs), they are time-consuming and require patient compliance. This study investigates whether surface topographic [surface topography (ST)] measurements of body volume difference (BVD) and torso volume difference between maximum inhale and exhale correlate to values determined on PFTs. METHODS: This study included patients with idiopathic scoliosis and thoracic/thoracolumbar curves ≥40 degrees. Patients received ST scans, clinical examinations, and EOS biplanar radiographs on the same day. PFTs were performed within 3 months of ST/radiographic analysis. Univariate linear regression analysis was used to examine relationships between BVD, PFT values, and mean curves. RESULTS: Sixteen patients (14.6 ± 2.2 y, 69% females) with idiopathic scoliosis and mean thoracic/thoracolumbar curves of 62 degrees ± 15˚ degrees (45 degrees to 93 degrees) were assessed. BVD displayed statistically high-positive positive correlations with forced vital capacity ( R = 0.863, P < 0.0001), forced expiratory volume in 1 second ( R = 0.870, P < 0.001), vital capacity ( R = 0.802, P < 0.0001), and TLC ( R = 0.831, P < 0.0001. Torso volume difference showed similarly high positive correlations to forced vital capacity, forced expiratory volume in 1 second, vital capacity, and TLC, but not residual volume. No correlations emerged between the mean thoracic/thoracolumbar curve and BVD or PFT values. CONCLUSION: This study strongly endorses further investigation into ST scanning as an alternative to traditional PFTs for assessing pulmonary volumes. The noncontact and noninvasive nature of ST scanning presents a valuable alternative method for analyzing thoracic volume, particularly beneficial for patients unable to cooperate with standard PFTs. LEVEL OF EVIDENCE: Level II-prognostic.


Assuntos
Medidas de Volume Pulmonar , Testes de Função Respiratória , Escoliose , Humanos , Escoliose/fisiopatologia , Escoliose/diagnóstico por imagem , Feminino , Masculino , Adolescente , Criança , Medidas de Volume Pulmonar/métodos , Pulmão/fisiopatologia , Pulmão/diagnóstico por imagem , Espirometria/métodos
3.
J Pediatr Orthop ; 43(10): 608-614, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37599604

RESUMO

BACKGROUND: Up to 75% of patients with idiopathic scoliosis (IS) report back pain, but the exact contributors are unclear. This study seeks to assess how pain correlates with demographics, radiographic and surface topographic (ST) measurements, and patient-reported outcome measures (PROMs) in patients with IS. METHODS: Patient-Reported Outcome Measurement Information System (PROMIS) Pain Interference (PI) and Scoliosis Research Society revised (SRS-22r) pain domain from an IRB approved prospectively collected registry containing patients 11 to 21 years old with IS were correlated (Spearman coefficients) with measurements from whole-body EOS radiography and ST scanning, PROMIS 1.0 PROMs, Trunk Appearance Perception Scale (TAPS), and SRS-22r domains. SRS-22r and PROMIS-PI were also compared between different sex, scoliosis severities, and primary curve locations with Mann-Whitney U or Kruskal-Wallis tests, and if significant differences were found, included with the 5 highest univariate correlated variables into stepwise multivariate linear regression models ( P <0.05 to enter, P >0.1 to remove) predicting SRS-22r pain and PROMIS-PI. RESULTS: One hundred and forty-nine patients (14.5 ± 2.0 y, body mass index 20.6 ± 4.1 kg/m 2 , 96 (64%) female, mean major coronal curve 40 ± 19 deg, range: 10 deg, 83 deg) reported mean PROMIS-PI of 42.2 ± 10.0 and SRS-22r pain of 4.4 ± 0.6. SRS-22r self-image was the most correlated variable with both SRS-22r pain (rho=0.519) and PROMIS-PI (rho=-0.594). Five variables, none of which were ST or radiographic measures, strongly predicted SRS pain domain (R=0.711, R2=0.505, N=138). Two variables (SRS-22r self-image and SRS-22r function) were utilized by a model correlated with PROMIS-PI (R=0.687, R2=0.463, N=124). CONCLUSIONS: SRS-22r function and self-image domains were more strongly correlated with SRS-22r pain and PROMIS-PI than any radiographic or ST measurements. LEVEL OF EVIDENCE: Level II-retrospective study.

4.
J Biomech Eng ; 144(8)2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35147162

RESUMO

The foot is a highly complex biomechanical system for which finite element (FE) modeling has been used to evaluate its loading environment. However, there is limited knowledge of first metatarsophalangeal (MTP) and first metatarsocuneiform (MTC) joint contact mechanics. Our goal was to develop a framework for FE modeling of the medial forefoot which could accurately predict experimental measurements of first MTP and first MTC joint loading. Simulations of planus and rectus foot types were conducted for midstance of gait. A custom-built force-controlled cadaveric test-rig was used to derive intracapsular pressure sensor measurements of contact pressure, force, and area during quasi-static loading. The FE model was driven under the same boundary and loading conditions as the cadaver. Mesh sensitivity analyses and best-fit calibrations of moduli for first MTP and first MTC joint cartilage were performed. Consistent with previous experimental research, a lower compressive modulus was best-fit to the first MTP compared to first MTC joint at 10 MPa and 20 MPa, respectively. Mean errors in contact pressures, forces, and areas were 24%, 4%, and 40% at the first MTP joint and 23%, 12%, and 19% at the first MTC joint, respectively. The present developmental framework may provide a basis for future modeling of first MTP and first MTC joint contact mechanics. This study acts as a precursor to validation of realistic physiological loading across gait to investigate joint loading, foot type biomechanics, and surgical interventions of the medial forefoot.


Assuntos
, Articulação Metatarsofalângica , Fenômenos Biomecânicos , Análise de Elementos Finitos , Marcha/fisiologia , Humanos , Articulação Metatarsofalângica/fisiologia
5.
Arthroscopy ; 38(2): 404-416.e3, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34126220

RESUMO

PURPOSE: The purpose of our study was to compare lower extremity rotational kinematics and kinetics (angles, torques, and powers) and hip muscle electromyography (EMG) activity between cam-type femoroacetabular impingement syndrome (FAIS) and age- and sex-matched controls during walking, fast walking, stair ascent, stair descent, and sit-to-stand. METHODS: This study included 10 males with unilateral FAIS and 10 control males with no FAIS. We measured kinematics, kinetics, and electromyographic signals during stair ascent/descent, sit-to-stand, self-selected walk, and fast walk. Peak signal differences between groups were compared with independent t-tests with statistical significance when P < .05. RESULTS: FAIS hips showed significant differences compared to controls, including increased hip flexion during walking (+4.9°, P = .048) and stair ascent (+7.8°, P =.003); diminished trunk rotation during stair ascent (-3.4°; P = .015), increased knee flexion during self-selected walking (+5.1°, P = .009), stair ascent (+7.4°, P = .001), and descent (+5.3°, P = .038); and increased knee valgus during fast walking (+4.7°, P = .038). gMed and MedHam showed significantly decreased activation in FAIS during walking (gMed: -12.9%, P = .002; MedHam: -7.4%, P = .028) and stair ascent (gMed: -16.7%, P = .036; MedHam: -13.0%, P = .041); decreased gMed activation during sit-to-stand (-8.8%, P = .004) and decreased MedHam activation during stair descent (-8.0%, P = .039). CONCLUSIONS: Three-dimensional motion analysis and EMG evaluation of functional kinematics and kinetics in subjects with symptomatic unilateral cam-type FAIS across a spectrum of provocative tasks demonstrated significant differences compared to controls in hip flexion, trunk rotation, knee flexion, and valgus. FAIS hips had significantly decreased gMed and MedHam activity. These findings may explain altered torso-pelvic, hip, and knee mechanics in FAIS patients and suggest that evaluation of FAIS should include the patient's hip, knee, and torso-pelvic relationships and muscle function. CLINICAL RELEVANCE: The clinical and functional manifestation of FAIS hip pathomechanics is not entirely understood, and previous literature to date has not clearly described the alterations in gait and functional movements seen in patients with cam-type FAIS. The current study used 3D motion analysis and EMG evaluation of functional kinematics and kinetics to identify a number of differences between FAIS and control hips, which help us better understand the lower extremity kinematics and kinetics and muscle activation in FAIS.


Assuntos
Impacto Femoroacetabular , Fenômenos Biomecânicos , Marcha , Quadril , Humanos , Articulação do Joelho , Masculino , Caminhada/fisiologia
6.
BMC Musculoskelet Disord ; 20(1): 158, 2019 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-30967130

RESUMO

BACKGROUND: Chronic low back pain (cLBP) affects millions of Americans and costs billions. Studies suggest a link between cLBP and joint hypermobility. METHODS: We conducted cross-sectional primary analyses of joint hypermobility and cLBP, lumbar spine osteoarthritis (OA), and lumbar facet joint OA (FOA) in 3 large studies-the Generalized Osteoarthritis Study, Genetics of Generalized Osteoarthritis Study, and Johnston County Osteoarthritis Project (total n = 5072). Associations of joint hypermobility and Beighton trunk flexion with cLBP and lumbar OA were estimated using separate adjusted logistic regression models. Adjusted pooled odds ratios (pORs) and 95% confidence intervals (CIs) were then summarized-using random effect univariate, multivariate crude, and adjusted models-and heterogeneity was determined (I2 statistic). RESULTS: In univariate models, hypermobility was associated with symptomatic FOA (pOR = 0.64 [95% CI 0.44, 0.93]) but this result was not found in the multivariate models. In multivariate adjusted models, hypermobility was not significantly associated with cLBP and lumbar OA, but trunk flexion was inversely associated with cLBP (pOR = 0.40 [95% 0.26, 0.62]), spine OA (pOR = 0.66 [95% CI 0.50, 0.87]), symptomatic spine OA (pOR = 0.39 [95% CI 0.28, 0.53]), and symptomatic FOA (pOR = 0.53 [95% CI 0.37, 0.77]). Generally, between-study heterogeneity was moderate-high. CONCLUSIONS: Hypermobility was not associated with cLBP or lumbar OA. The inverse association of trunk flexion with cLBP and lumbar OA may indicate a role for a flexible spine in avoiding or managing these conditions.


Assuntos
Instabilidade Articular/fisiopatologia , Dor Lombar/fisiopatologia , Vértebras Lombares/fisiopatologia , Osteoartrite da Coluna Vertebral/fisiopatologia , Idoso , Estudos de Casos e Controles , Estudos de Coortes , Estudos Transversais , Feminino , Humanos , Instabilidade Articular/diagnóstico , Instabilidade Articular/epidemiologia , Estudos Longitudinais , Dor Lombar/diagnóstico , Dor Lombar/epidemiologia , Vértebras Lombares/patologia , Masculino , Pessoa de Meia-Idade , Osteoartrite da Coluna Vertebral/diagnóstico , Osteoartrite da Coluna Vertebral/epidemiologia
7.
J Shoulder Elbow Surg ; 27(4): 624-634, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29269137

RESUMO

BACKGROUND: Shoulder capsular plication aims to restore the passive stabilization of the glenohumeral capsule; however, high reported recurrence rates warrant concern. Improving our understanding of the clinical laxity assessment across 2 dimensions, capsular integrity and shoulder position, can help toward the standardization of clinical tools. Our objectives were to test and describe glenohumeral laxity across 5 capsular tension levels and 4 humeral position levels and describe tension-position interplay. METHODS: We tested 14 dissected cadavers for glenohumeral laxity in 5 directions: anterior, posterior, and inferior translation, and internal and external axial rotation. Laxity was recorded across capsule tension (baseline, stretched, 5 mm, 10 mm, and 15 mm of plication) and position (0°, 20°, 40°, 60° of scapular abduction). Repeated-measures analysis of variance with post hoc contrasts tested the effect of tension, position, and composite tension × position on laxity. RESULTS: Capsule tension, position, and composite interplay had a statistically significant, although unequal, effect on laxity in each direction. Laxity was consistently overconstrained in 15-mm plication and was overall greatest in 20° and lowest in 60°. Restoration occurred most in 10 mm, but this depended on the position. The composite effect was significant for external and internal rotation and inferior laxity, but laxity at the middle range (20° or 40°) was different than at the end range (0° or 60°) for all directions. CONCLUSIONS: On average, laxity was restored to baseline tension after 10-mm plication, but this determination varied depending on shoulder position. Middle-range laxity behaved differently than end-range laxity across plication tensions. This information is useful in understanding the unstable shoulder as well as for standardizing clinical laxity assessment.


Assuntos
Cápsula Articular/cirurgia , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Articulação do Ombro/fisiopatologia , Adulto , Idoso , Fenômenos Biomecânicos , Cadáver , Humanos , Úmero , Masculino , Pessoa de Meia-Idade , Postura , Amplitude de Movimento Articular , Rotação
8.
J Appl Biomech ; 33(3): 203-210, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27992254

RESUMO

It has been suggested that foot type considers not only foot structure (high, normal, low arch), but also function (overpronation, normal, oversupination) and flexibility (reduced, normal, excessive). Therefore, this study used canonical regression analyses to assess which variables of foot structure, function, and flexibility can accurately discriminate between clinical foot type classifications. The feet of 61 asymptomatic, healthy adults (18-77 years) were classified as cavus (N = 24), rectus (N = 54), or planus (N = 44) using standard clinical measures. Custom jigs assessed foot structure and flexibility. Foot function was assessed using an emed-x plantar pressure measuring device. Canonical regression analyses were applied separately to extract essential structure, flexibility, and function variables. A third canonical regression analysis was performed on the extracted variables to identify a combined model. The initial combined model included 30 extracted variables; however 5 terminal variables (malleolar valgus index, arch height index while sitting, first metatarsophalangeal joint laxity while standing, pressure-time integral and maximum contact area of medial arch) were able to correctly predict 80.7% of foot types. These remaining variables focused on specific foot characteristics (hindfoot alignment, arch height, midfoot mechanics, Windlass mechanism) that could be essential to discriminating foot type.


Assuntos
Antropometria , Pé/anatomia & histologia , Pé/fisiologia , Adolescente , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Humanos , Instabilidade Articular , Masculino , Pessoa de Meia-Idade , Postura , Pressão , Análise de Regressão , Estudos Retrospectivos , Adulto Jovem
9.
Pediatr Phys Ther ; 29(1): 83-88, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27984478

RESUMO

PURPOSE: To determine the intrarater and interrater reliability of the arch height index (AHI) in children developing typically. The AHI is tested with a device that measures foot structure. METHODS: Thirty children, ages 6 to 12 years, participated for a total of n = 60 feet. The AHI measurements were taken by 2 investigators in sitting and standing and repeated twice by each investigator in a single visit. Intrarater and interrater reliabilities were determined using intraclass correlation coefficient (ICC) (2,1) statistical analysis. RESULTS: The mean age was 9.61 ± 1.96 years. The intrarater and interrater reliability had an ICC 0.76 or more in both sitting and standing. The average AHI value was 0.36 ± 0.02 in sitting and 0.32 ± 0.02 in standing. CONCLUSIONS: Pediatric therapists, physicians, and orthotists should consider using the AHI as an objective measure to be used for research, to assess foot structure, monitor change over time, and assist with treatment planning in children.


Assuntos
Pé Chato/diagnóstico , Modalidades de Fisioterapia/instrumentação , Índice de Massa Corporal , Criança , Feminino , Humanos , Masculino , Postura , Reprodutibilidade dos Testes
10.
J Sports Sci ; 34(15): 1388-95, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26588262

RESUMO

Alterations in joint mechanics have been associated with common overuse injuries. An increase in running cadence in healthy runners has been shown to improve several parameters that have been tied to injury, but the reorganisation of motion that produces these changes has not been examined. The purpose of this study was to determine if runners change their segment coordination and coordination variability with an acute increase in cadence. Data were collected as ten uninjured runners ran overground at their preferred cadence as well as a cadence 10% higher than preferred. Segment coordination and coordination variability were calculated for select thigh-shank and shank-foot couples and selected knee mechanics were also calculated. Paired t-tests were used to examine differences between the preferred and increased cadence conditions. With increased cadence, there was a decrease in peak knee flexion and a later occurrence of peak knee flexion and internal rotation and shank internal rotation. Segment coordination was altered with most changes occurring in mid-late stance. Coordination variability decreased with an increase in cadence across all couples and phases of gait. These results suggest examination of coordination and its variability could give insight into the risk of intervention-induced injury.


Assuntos
Marcha/fisiologia , Corrida/fisiologia , Aceleração , Adulto , Fenômenos Biomecânicos , Transtornos Traumáticos Cumulativos/fisiopatologia , Feminino , Pé/fisiologia , Humanos , Articulação do Joelho/fisiologia , Masculino , Fatores de Risco , Rotação , Corrida/lesões , Estudos de Tempo e Movimento
11.
J Sports Sci ; 33(7): 724-31, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25369525

RESUMO

Many studies have documented the association between mechanical deviations from normal and the presence or risk of injury. Some runners attempt to change mechanics by increasing running cadence. Previous work documented that increasing running cadence reduces deviations in mechanics tied to injury. The long-term effect of a cadence retraining intervention on running mechanics and energy expenditure is unknown. This study aimed to determine if increasing running cadence by 10% decreases running efficiency and changes kinematics and kinetics to make them less similar to those associated with injury. Additionally, this study aimed to determine if, after 6 weeks of cadence retraining, there would be carryover in kinematic and kinetic changes from an increased cadence state to a runner's preferred running cadence without decreased running efficiency. We measured oxygen uptake, kinematic and kinetic data on six uninjured participants before and after a 6-week intervention. Increasing cadence did not result in decreased running efficiency but did result in decreases in stride length, hip adduction angle and hip abductor moment. Carryover was observed in runners' post-intervention preferred running form as decreased hip adduction angle and vertical loading rate.


Assuntos
Educação Física e Treinamento/métodos , Corrida/fisiologia , Adulto , Fenômenos Biomecânicos , Metabolismo Energético , Feminino , Humanos , Extremidade Inferior/fisiologia , Masculino , Movimento , Consumo de Oxigênio , Projetos Piloto , Fatores de Risco , Corrida/lesões , Estudos de Tempo e Movimento
12.
J Hand Surg Am ; 40(8): 1547-53, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26092664

RESUMO

PURPOSE: The purpose of this investigation was to compare kinematic motion and functional performance during 2 tasks in patients following 4-corner fusion (4CF) or proximal row carpectomy (PRC) and to compare these data with those from healthy asymptomatic individuals. METHODS: Twenty men (10 4CFs and 10 PRCs, ages, 43-82 y) were recruited for 3-dimensional wrist motion analysis testing. Kinematic coupling (the ratio of wrist flexion/extension to radial-ulnar deviation), kinematic path length (a measure of total angle distance), clinical measures, and performance measures were collected during 2 tasks: dart throwing and hammering. For each outcome, between-group comparisons employed a 1-way analysis of variance with post hoc analysis using the Fisher least significant difference test. RESULTS: All clinical measures (flexion-extension, radial-ulnar deviation, and grip strength) were decreased for 4CF and PRC patients compared with healthy subjects. Coupling, kinematic path length, and performance were all significantly reduced in 4CF and PRC patients compared with healthy subjects during both tasks. Reduced coupling and a shorter kinematic path length are indicative of less global and combined wrist motion. There were no differences identified in coupling patterns or performance between the surgical groups for the dart-throwing task. However, in hammering, the kinematic path length and performance (time and total strikes) were worse in 4CF than in PRC. CONCLUSIONS: Differences in wrist kinematics and performance were identified between the groups. PRC subjects performed better on kinematic and performance variables. As expected, both groups demonstrated decreased wrist kinematic motion and functional performance compared with individuals with normal wrists. These results require confirmation and while they cannot be used to determine the benefits of one procedure over the other, they are an important step in quantifying differences in motion and function between procedures. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic II.


Assuntos
Artrodese , Ossos do Carpo/cirurgia , Articulações do Carpo/cirurgia , Artropatias/cirurgia , Articulação do Punho/fisiopatologia , Adulto , Idoso , Estudos de Casos e Controles , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Análise e Desempenho de Tarefas
13.
J Hand Surg Am ; 39(4): 634-642.e1, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24582842

RESUMO

PURPOSE: To quantify the coupled motion of the wrist during selected functional tasks and to determine the effects of constraining this coupled motion using a radial-ulnar deviation blocking splint on performance of these tasks. METHODS: Ten healthy, right-handed men performed 15 trials during selected functional tasks with and without a splint, blocking radial and ulnar deviation. The following tasks were performed: dart throwing, hammering, basketball free-throw, overhand baseball and football throwing, clubbing, and pouring. Kinematic coupling parameters (coupling, kinematic path length, flexion-extension range of motion, radial-ulnar deviation range of motion, flexion-extension offset, and radial-ulnar deviation offset) and performance were determined for each functional task. A generalized estimation equation model was used to determine whether each kinematic coupling parameter was significantly different across tasks. A repeated-measures generalized estimation equation model was used to test for differences in performance and kinematic coupling parameters between the free and splinted conditions. RESULTS: Wrist motion exhibited linear coupling between flexion-extension and radial-ulnar deviation, demonstrated by R(2) values from 0.70 to 0.99. Average wrist coupling and kinematic path lengths were significantly different among tasks. Coupling means and kinematic path lengths were different between free and splinted conditions across all tasks other than pouring. Performance was different between wrist conditions for dart throwing, hammering, basketball shooting, and pouring. CONCLUSIONS: Wrist kinematic coupling parameters are task specific in healthy individuals. Functional performance is decreased when wrist coupling is constrained by an external splint. CLINICAL RELEVANCE: Surgical procedures that restrict wrist coupling may have a detrimental effect on functional performance as defined in the study. Patients may benefit from surgical reconstructive procedures and wrist rehabilitation protocols designed to restore kinematic coupling.


Assuntos
Movimento/fisiologia , Contenções , Análise e Desempenho de Tarefas , Articulação do Punho/fisiologia , Adulto , Fenômenos Biomecânicos , Humanos , Masculino , Adulto Jovem
14.
J Appl Biomech ; 30(4): 586-93, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24615208

RESUMO

The purpose of this study was to develop a three-dimensional (3D) motion analysis based anatomical wrist joint coordinate system for measurement of in-vivo wrist kinematics. The convergent validity and reliability of the 3D motion analysis implementation was quantified and compared with manual and electrogoniometry techniques on 10 cadaveric specimens. Fluoroscopic measurements were used as the reference. The 3D motion analysis measurements (mean absolute difference [MAD] = 3.6°) were significantly less different (P < .005) than manual goniometry (MAD = 5.7°) but not (P = .066, power = 0.45) electrogoniometry (MAD = 5.0°) compared with fluoroscopy. The intraclass correlation coefficient (ICC[2,1]) was highest for 3D motion analysis compared with manual and electrogoniometry, suggesting better reliability for this technique. To demonstrate the utility of this new wrist joint coordinate system, normative data from 10 healthy subjects was obtained while throwing a dart.


Assuntos
Pontos de Referência Anatômicos/anatomia & histologia , Imageamento Tridimensional/métodos , Modelos Anatômicos , Modelos Biológicos , Amplitude de Movimento Articular/fisiologia , Articulação do Punho/anatomia & histologia , Articulação do Punho/fisiologia , Cadáver , Simulação por Computador , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
J Appl Biomech ; 30(1): 82-94, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23878206

RESUMO

Increased joint stress and malalignment are etiologic factors in osteoarthritis. Static tibiofemoral frontal plane malalignment is associated with patellofemoral osteoarthritis (PFOA). Patellofemoral joint stress is increased by activities such as sit-to-stand (STS); this stress may be even greater if dynamic frontal plane tibiofemoral malalignment occurs. If hip muscle or quadriceps weakness is present in persons with PFOA, aberrant tibiofemoral frontal plane movement may occur, with increased patellofemoral stress. No studies have investigated frontal plane tibiofemoral and hip kinematics during STS in persons with PFOA or the relationship of hip muscle and quadriceps strength to these motions. Eight PFOA and seven control subjects performed STS from a stool during three-dimensional motion capture. Hip muscle and quadriceps strength were measured as peak isometric force. The PFOA group demonstrated increased peak tibial abduction angles during STS, and decreased hip abductor, hip extensor, and quadriceps peak force versus controls. A moderate inverse relationship between peak tibial abduction angle and peak hip abductor force was present. No difference between groups was found for peak hip adduction angle or peak hip external rotator force. Dynamic tibiofemoral malalignment and proximal lower extremity weakness may cause increased patellofemoral stress and may contribute to PFOA incidence or progression.


Assuntos
Articulação do Quadril/fisiopatologia , Articulação do Joelho/fisiopatologia , Movimento , Força Muscular , Músculo Esquelético/fisiopatologia , Osteoartrite do Joelho/fisiopatologia , Articulação Patelofemoral/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Postura , Amplitude de Movimento Articular
16.
J Robot Surg ; 18(1): 278, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38960985

RESUMO

Historically, pedicle screw accuracy measurements have relied on CT and expert visual assessment of the position of pedicle screws relative to preoperative plans. Proper pedicle screw placement is necessary to avoid complications, cost and morbidity of revision procedures. The aim of this study was to determine accuracy and precision of pedicle screw insertion via a novel computer vision algorithm using preoperative and postoperative computed tomography (CT) scans. Three cadaveric specimens were utilized. Screw placement planning on preoperative CT was performed according to standard clinical practice. Two experienced surgeons performed bilateral T2-L4 instrumentation using robotic-assisted navigation. Postoperative CT scans of the instrumented levels were obtained. Automated segmentation and computer vision techniques were employed to align each preoperative vertebra with its postoperative counterpart and then compare screw positions along all three axes. Registration accuracy was assessed by preoperatively embedding spherical markers (tantalum beads) to measure discrepancies in landmark alignment. Eighty-eight pedicle screws were placed in 3 cadavers' spines. Automated registrations between pre- and postoperative CT achieved sub-voxel accuracy. For the screw tip and tail, the mean three-dimensional errors were 1.67 mm and 1.78 mm, respectively. Mean angular deviation of screw axes from plan was 1.58°. For screw mid-pedicular accuracy, mean absolute error in the medial-lateral and superior-inferior directions were 0.75 mm and 0.60 mm, respectively. This study introduces automated algorithms for determining accuracy and precision of planned pedicle screws. Our accuracy outcomes are comparable or superior to recent robotic-assisted in vivo and cadaver studies. This computerized workflow establishes a standardized protocol for assessing pedicle screw placement accuracy and precision and provides detailed 3D translational and angular accuracy and precision for baseline comparison.


Assuntos
Algoritmos , Cadáver , Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos , Tomografia Computadorizada por Raios X , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Vértebras Lombares/cirurgia , Vértebras Lombares/diagnóstico por imagem , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Cirurgia Assistida por Computador/métodos
17.
Rheumatology (Oxford) ; 52(12): 2275-82, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24049103

RESUMO

OBJECTIVE: Abnormal foot posture and function have been proposed as possible risk factors for low back pain, but this has not been examined in detail. The objective of this study was to explore the associations of foot posture and foot function with low back pain in 1930 members of the Framingham Study (2002-05). METHODS: Low back pain, aching or stiffness on most days was documented on a body chart. Foot posture was categorized as normal, planus or cavus using static weight-bearing measurements of the arch index. Foot function was categorized as normal, pronated or supinated using the centre of pressure excursion index derived from dynamic foot pressure measurements. Sex-specific multivariate logistic regression models were used to examine the associations of foot posture, foot function and asymmetry with low back pain, adjusting for confounding variables. RESULTS: Foot posture showed no association with low back pain. However, pronated foot function was associated with low back pain in women [odds ratio (OR) = 1.51, 95% CI 1.1, 2.07, P = 0.011] and this remained significant after adjusting for age, weight, smoking and depressive symptoms (OR = 1.48, 95% CI 1.07, 2.05, P = 0.018). CONCLUSION: These findings suggest that pronated foot function may contribute to low back symptoms in women. Interventions that modify foot function, such as orthoses, may therefore have a role in the prevention and treatment of low back pain.


Assuntos
Doenças do Pé/fisiopatologia , Pé/fisiopatologia , Dor Lombar/etiologia , Pronação/fisiologia , Supinação/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Dor Lombar/prevenção & controle , Masculino , Pessoa de Meia-Idade , Fatores Sexuais , Suporte de Carga/fisiologia
18.
Spine Deform ; 11(4): 871-880, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36881217

RESUMO

PURPOSE: Adolescent idiopathic scoliosis (AIS) is a deformity of the spine that results in external asymmetry of the torso in the shoulder, waist, and rib hump. Several patient reported outcome measures (PROMS) including the Trunk Appearance Perception Scale (TAPS) and SRS-22r self-image domain are used to measure the patient's self-perception. The purpose of this study is to investigate the relationship between objective surface topographic measurements of the torso to subjective patient self-perception. METHODS: 131 AIS subjects and 37 controls participated in this study. All subjects completed TAPS and SRS-22r PROMS followed by whole body 3d surface topographic scanning. An automated analysis pipeline was used to compute 57 measurements. Multivariate linear models were developed to predict TAPS and SRS-22r self-image using each unique combination of 3 parameters and leave one out validation where the best combinations were selected. RESULTS: Back surface rotation, waist crease vertical asymmetry and rib prominence volume were most predictive of TAPS. The final predicted TAPS values from leave one out cross validation was correlated to ground truth TAPS scores with an R value of 0.65. Back surface rotation, silhouette centroid deviation, and shoulder normal asymmetry were most predictive of SRS-22r self-image with a correlation of R = 0.48. CONCLUSION: Surface topographic measurements of the torso are correlated to TAPS and SRS-22r self-image scores in AIS patients and controls, with TAPS exhibiting a stronger relationship, better reflecting the patient's external asymmetries.


Assuntos
Cifose , Escoliose , Adolescente , Humanos , Qualidade de Vida , Coluna Vertebral , Inquéritos e Questionários , Autoimagem
19.
Clin Biomech (Bristol, Avon) ; 102: 105887, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36657189

RESUMO

BACKGROUND: Early-onset osteoarthritis has been attributed to pro-inflammatory factors and biomechanical changes in obesity. However, research has yet to explore whether knee joint moments are asymmetrical in children with obesity and could precede the onset of knee osteoarthritis. The present study compares knee moment asymmetry between adolescents with and without obesity and examines the relationship between asymmetries and inflammatory biomarkers. METHODS: Twenty-eight adolescents (13-16 years) were classified as with (n = 12) or without (n = 16) obesity. Lower extremity kinetics were measured using three-dimensional motion analysis. Bilateral knee joint moments were analyzed in the sagittal, frontal, and transverse planes across stance phase. Kinetic asymmetry was calculated between the right and left sides and represented by the R2 value. Enzyme-linked immunosorbent assays analyzed serum 25-hydroxy vitamin D, interferon gamma, tumor nercrosis factor alpha, interleukin-6, and C-reactive protein levels. Parametric and non-parametric tests determined significant group differences in asymmetries and biomarkers, respectively. Spearman's correlations identified relationships between biomarkers and asymmetries with statistically significant group differences. FINDINGS: Adolescents with obesity had greater sagittal (loading, midstance) and frontal (midstance, pre-swing) plane kinetic knee asymmetry and higher concentrations of interleukin-6 and C-reactive protein. A moderately negative correlation existed between C-reactive protein and sagittal (loading, midstance) plane asymmetry, and also between interleukin-6 and frontal (pre-swing) plane asymmetry. INTERPRETATION: Inflammatory response increases with greater knee joint asymmetry, suggesting knee joint damage and altered joint loading co-exist in adolescents with obesity. Increased risk to joint health may exist in sub-phases where knee joints are improperly loaded.


Assuntos
Obesidade Infantil , Caminhada , Criança , Humanos , Adolescente , Caminhada/fisiologia , Proteína C-Reativa , Interleucina-6 , Marcha/fisiologia , Articulação do Joelho/fisiologia , Fenômenos Biomecânicos
20.
Spine Deform ; 10(5): 1035-1045, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35526210

RESUMO

PURPOSE: This study introduces a novel surface-topographic scanning system capable of automatically generating a suite of objective measurements to characterize torso shape. RESEARCH QUESTION: what is the reliability of the proposed system for measurement of trunk alignment parameters in patients with adolescent idiopathic scoliosis (AIS) and controls? METHODS: Forty-six adolescents (26 with AIS and 20 controls) were recruited for a prospective reliability study. A series of angular, volumetric, and area measures were computed from topographic scans in each of three clinically relevant poses using a fully automated processing pipeline. Intraclass correlation coefficients (ICC(2,1)) were computed within (intra-) and between (inter-) raters. Measurements were also performed on a torso phantom. RESULTS: Topographic measurements computed on a phantom were highly accurate (mean RMS error 1.7%) compared with CT. For human subjects, intra- and inter-rater reliability were both high (average ICC > 0.90) with intrinsic (pose-independent) measurements having near-perfect reliability (average ICC > 0.98). CONCLUSION: The proposed system is a suitable tool for topographic analysis of AIS; topographic measurements offer an objective description of torso shape that may complement other imaging modalities. Further research is needed to compare topographic findings with gold standard imaging of spinal alignment, e.g., standing radiography. CONCLUSION: clinical parameters can be reliably measured in a fully automated system, paving the way for objective analysis of symmetry, body shape pre/post-surgery, and tracking of pathology without ionizing radiation.


Assuntos
Cifose , Escoliose , Adolescente , Humanos , Estudos Prospectivos , Radiografia , Reprodutibilidade dos Testes , Escoliose/diagnóstico por imagem , Escoliose/cirurgia , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA