Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 34(1): 673-685, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37535156

RESUMO

OBJECTIVES: To calculate the pooled diagnostic performances of whole-body [18F]FDG PET/MR in M staging of [18F]FDG-avid cancer entities. METHODS: A diagnostic meta-analysis was conducted on the [18F]FDG PET/MR in M staging, including studies: (1) evaluated [18F]FDG PET/MR in detecting distant metastasis; (2) compared[ 18F]FDG PET/MR with histopathology, follow-up, or asynchronous multimodality imaging as the reference standard; (3) provided data for the whole-body evaluation; (4) provided adequate data to calculate the meta-analytic performances. Pooled performances were calculated with their confidence interval. In addition, forest plots, SROC curves, and likelihood ratio scatterplots were drawn. All analyses were performed using STATA 16. RESULTS: From 52 eligible studies, 2289 patients and 2072 metastases were entered in the meta-analysis. The whole-body pooled sensitivities were 0.95 (95%CI: 0.91-0.97) and 0.97 (95%CI: 0.91-0.99) at the patient and lesion levels, respectively. The pooled specificities were 0.99 (95%CI: 0.97-1.00) and 0.97 (95%CI: 0.90-0.99), respectively. Additionally, subgroup analyses were performed. The calculated pooled sensitivities for lung, gastrointestinal, breast, and gynecological cancers were 0.90, 0.93, 1.00, and 0.97, respectively. The pooled specificities were 1.00, 0.98, 0.97, and 1.00, respectively. Furthermore, the pooled sensitivities for non-small cell lung, colorectal, and cervical cancers were 0.92, 0.96, and 0.86, respectively. The pooled specificities were 1.00, 0.95, and 1.00, respectively. CONCLUSION: [18F]FDG PET/MR was a highly accurate modality in M staging in the reported [18F]FDG-avid malignancies. The results showed high sensitivity and specificity in each reviewed malignancy type. Thus, our findings may help clinicians and patients to be confident about the performance of [18F]FDG PET/MR in the clinic. CLINICAL RELEVANCE STATEMENT: Although [18F]FDG PET/MR is not a routine imaging technique in current guidelines, mostly due to its availability and logistic issues, our findings might add to the limited evidence regarding its performance, showing a sensitivity of 0.95 and specificity of 0.97. KEY POINTS: • The whole-body [18F]FDG PET/MR showed high accuracy in detecting distant metastases at both patient and lesion levels. • The pooled sensitivities were 95% and 97% and pooled specificities were 99% and 97% at patient and lesion levels, respectively. • The results suggested that 18F-FDG PET/MR was a strong modality in the exclusion and confirmation of distant metastases.


Assuntos
Fluordesoxiglucose F18 , Neoplasias , Humanos , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Imagem Multimodal/métodos , Estadiamento de Neoplasias , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
2.
Eur Radiol ; 33(2): 1102-1111, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36029344

RESUMO

OBJECTIVES: Establishing the reproducibility of expert-derived measurements on CTA exams of aortic dissection is clinically important and paramount for ground-truth determination for machine learning. METHODS: Four independent observers retrospectively evaluated CTA exams of 72 patients with uncomplicated Stanford type B aortic dissection and assessed the reproducibility of a recently proposed combination of four morphologic risk predictors (maximum aortic diameter, false lumen circumferential angle, false lumen outflow, and intercostal arteries). For the first inter-observer variability assessment, 47 CTA scans from one aortic center were evaluated by expert-observer 1 in an unconstrained clinical assessment without a standardized workflow and compared to a composite of three expert-observers (observers 2-4) using a standardized workflow. A second inter-observer variability assessment on 30 out of the 47 CTA scans compared observers 3 and 4 with a constrained, standardized workflow. A third inter-observer variability assessment was done after specialized training and tested between observers 3 and 4 in an external population of 25 CTA scans. Inter-observer agreement was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. RESULTS: Pre-training ICCs of the four morphologic features ranged from 0.04 (-0.05 to 0.13) to 0.68 (0.49-0.81) between observer 1 and observers 2-4 and from 0.50 (0.32-0.69) to 0.89 (0.78-0.95) between observers 3 and 4. ICCs improved after training ranging from 0.69 (0.52-0.87) to 0.97 (0.94-0.99), and Bland-Altman analysis showed decreased bias and limits of agreement. CONCLUSIONS: Manual morphologic feature measurements on CTA images can be optimized resulting in improved inter-observer reliability. This is essential for robust ground-truth determination for machine learning models. KEY POINTS: • Clinical fashion manual measurements of aortic CTA imaging features showed poor inter-observer reproducibility. • A standardized workflow with standardized training resulted in substantial improvements with excellent inter-observer reproducibility. • Robust ground truth labels obtained manually with excellent inter-observer reproducibility are key to develop reliable machine learning models.


Assuntos
Dissecção Aórtica , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Dissecção Aórtica/diagnóstico por imagem , Aorta
3.
Eur J Nucl Med Mol Imaging ; 49(12): 4205-4217, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35705874

RESUMO

PURPOSE: To calculate the diagnostic performance of [18F]-FDG PET/MR in colorectal cancer (CRC). METHODS: This study was designed following the PRISMA-DTA guidelines. To be included, published original articles (until December 31, 2021) that met the following criteria were considered eligible: (1) evaluated [18F]-FDG PET/MR as the diagnostic method to detect CRC; (2) compared [18F]-FDG PET/MR with histopathology as the reference standard, or clinical/imaging composite follow-up when pathology was not available; (3) provided adequate crude data for meta-analysis. The diagnostic pooled measurements were calculated at patient and lesion levels. Regarding sub-group analysis, diagnostic measurements were calculated in "TNM staging," "T staging," "N staging," "M staging," and "liver metastasis" sub-groups. Additionally, we calculated the pooled performances in "rectal cancer: patient-level" and "rectal cancer: lesion-level" sub-groups. A hierarchical method was used to pool the performances. The bivariate model was conducted to find the summary points. Analyses were performed using STATA 16. RESULTS: A total of 1534 patients from 18 studies were entered. The pooled sensitivities in CRC lesion detection (tumor, lymph nodes, and metastases) were 0.94 (95%CI: 0.89-0.97) and 0.93 (95%CI: 0.82-0.98) at patient-level and lesion-level, respectively. The pooled specificities were 0.89 (95%CI: 0.84-0.93) and 0.95 (95%CI: 0.90-0.98) at patient-level and lesion-level, respectively. In sub-groups, the highest sensitivity (0.97, 95%CI: 0.86-0.99) and specificity (0.99, 95%CI: 0.84-1.00) were calculated for "M staging" and "rectal cancer: lesion-level," respectively. The lowest sensitivity (0.81, 95%CI: 0.65-0.91) and specificity (0.79, 95%CI: 0.52-0.93) were calculated for "N staging" and "T staging," respectively. CONCLUSION: This meta-analysis showed an overall high diagnostic performance for [18F]-FDG PET/MR in detecting CRC lesions/metastases. Thus, this modality can play a significant role in several clinical scenarios in CRC staging and restaging. Specifically, one of the main strengths of this modality is ruling out the existence of CRC lesions/metastases. Finally, the overall diagnostic performance was not found to be affected in the post-treatment setting.


Assuntos
Neoplasias Colorretais , Neoplasias Retais , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Fluordesoxiglucose F18 , Humanos , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Neoplasias Retais/patologia , Sensibilidade e Especificidade
4.
Eur Radiol ; 32(3): 1823-1832, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34559264

RESUMO

OBJECTIVES: To investigate, in patients with metastatic prostate cancer, whether radiomics of computed tomography (CT) image data enables the differentiation of bone metastases not visible on CT from unaffected bone using 68 Ga-PSMA PET imaging as reference standard. METHODS: In this IRB-approved retrospective study, 67 patients (mean age 71 ± 7 years; range: 55-84 years) showing a total of 205 68 Ga-PSMA-positive prostate cancer bone metastases in the thoraco-lumbar spine and pelvic bone being invisible in CT were included. Metastases and 86 68 Ga-PSMA-negative bone volumes in the same body region were segmented and further post-processed. Intra- and inter-reader reproducibility was assessed, with ICCs < 0.90 being considered non-reproducible. To account for imbalances in the dataset, data augmentation was performed to achieve improved class balance and to avoid model overfitting. The dataset was split into training, test, and validation set. After a multi-step dimension reduction process and feature selection process, the 11 most important and independent features were selected for statistical analyses. RESULTS: A gradient-boosted tree was trained on the selected 11 radiomic features in order to classify patients' bones into bone metastasis and normal bone using the training dataset. This trained model achieved a classification accuracy of 0.85 (95% confidence interval [CI]: 0.76-0.92, p < .001) with 78% sensitivity and 93% specificity. The tuned model was applied on the original, non-augmented dataset resulting in a classification accuracy of 0.90 (95% CI: 0.82-0.98) with 91% sensitivity and 88% specificity. CONCLUSION: Our proof-of-concept study indicates that radiomics may accurately differentiate unaffected bone from metastatic bone, being invisible by the human eye on CT. KEY POINTS: • This proof-of-concept study showed that radiomics applied on CT images may accurately differentiate between bone metastases and metastatic-free bone in patients with prostate cancer. • Future promising applications include automatic bone segmentation, followed by a radiomics classifier, allowing for a screening-like approach in the detection of bone metastases.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Idoso , Radioisótopos de Gálio , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
5.
J Neuroradiol ; 49(1): 9-16, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34023361

RESUMO

INTRODUCTION: In patients with ulnar neuropathy at the elbow (UNE) the precise determination of the site of lesion is important for subsequent differential diagnostic considerations and therapeutic management. Due to a paucity of comparable data, to better define the role of different diagnostic tests, we performed the first prospective study comparing the diagnostic accuracy of short segment nerve stimulation, nerve ultrasonography, MR neurography (MRN), and diffusion tensor imaging (DTI) in patients with UNE. METHODS: UNE was clinically diagnosed in 17 patients with 18 affected elbows. For all 18 affected elbows in patients and 20 elbows in 10 healthy volunteers, measurements of all different diagnostic tests were performed at six anatomical positions across the elbow with measuring points from distal (D4) to proximal (P6) in relation to the medial epicondyle (P0). Additional qualitative assessment regarding structural changes of surrounding nerve anatomy was conducted. RESULTS: The difference between affected arms of patients and healthy control arms were most frequently the largest at measure intervals D2 to P0 and P0 to P2 for electrophysiological testing, or measure points P0 and P2 for all other devices, respectively. At both levels P0 and at P2, T2 contrast-to-noise ratio (CNR) of MRN and mean diffusivity (MD) of DTI-based MRN showed best accuracies. DISCUSSION: This study revealed differences in diagnostic performance of tests concerning a specific location of UNE, with better results for T2 contrast to noise ratio (CNR) in MRN and mean diffusivity of DTI-based MRN. Additional testing with MRN and nerve ultrasonography is recommended to uncover anatomical changes.


Assuntos
Cotovelo , Neuropatias Ulnares , Imagem de Tensor de Difusão , Cotovelo/diagnóstico por imagem , Eletrodiagnóstico , Humanos , Condução Nervosa , Estudos Prospectivos , Nervo Ulnar , Neuropatias Ulnares/diagnóstico por imagem
6.
Radiology ; 301(1): 105-112, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34342499

RESUMO

Background Current risk models show limited performances for predicting all-cause mortality after transcatheter aortic valve replacement (TAVR). Purpose To determine the prognostic value of coronary artery calcium (CAC) scoring for predicting 30-day and 1-year mortality in patients undergoing TAVR. Materials and Methods In this single-center institutional review board-approved secondary analysis of prospectively collected data (SwissTAVI Registry), the authors evaluated participants who, before TAVR, underwent CT that included a nonenhanced electrocardiography-gated cardiac scan between May 2008 and September 2019 and who had not undergone previous coronary revascularization. Clinical data, including the European System for Cardiac Operative Risk Evaluation (EuroSCORE II), were recorded. The CAC score was determined, and 30-day and 1-year all-cause mortality were assessed by using Cox regression analyses. Results In total, 309 participants (mean age ± standard deviation, 81 years ± 7; 175 women) were included, with a median CAC score of 334 (interquartile range, 104-987). Seventy-seven of the 309 participants (25%) had a CAC score greater than or equal to 1000. A CAC score of 1000 or greater served as an independent predictor of 30-day (hazard ratio [HR], 4.5 [95% CI: 1.5, 13.6] compared with a CAC score <1000; P = .007) and 1-year (HR, 4.3 [95% CI: 1.5, 12.7] compared with a CAC score of 0-99; P = .008) mortality after TAVR. Similar trends were observed for each point increase of the EuroSCORE II as an independent predictor of 30-day (HR, 1.22 [95% CI: 1.10, 1.36]; P < .001) and 1-year (HR, 1.16 [95% CI: 1.08, 1.25]; P < .001) mortality. Adding the CAC score to the EuroSCORE II provided incremental prognostic value for 1-year mortality after TAVR over the EuroSCORE II alone (concordance index, 0.76 vs 0.69; P = .04). Conclusion In participants without prior coronary revascularization, the coronary artery calcium score represented an independent predictor of 30-day and 1-year mortality after transcatheter aortic valve replacement. ClinicalTrials.gov identifier, NCT01368250 © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Almeida in this issue.


Assuntos
Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Substituição da Valva Aórtica Transcateter/mortalidade , Calcificação Vascular/diagnóstico , Calcificação Vascular/mortalidade , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Prognóstico , Estudos Prospectivos , Sistema de Registros/estatística & dados numéricos , Índice de Gravidade de Doença , Suíça/epidemiologia , Resultado do Tratamento
7.
Radiology ; 291(2): 531-538, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30835189

RESUMO

Background Optimal timing of the CT scan relative to the contrast media bolus remains a challenging task given the shorter scan durations of modern CT scanners, as well as interpatient variability. Purpose To compare contrast opacification in CT angiography of the aorta between a cohort with fixed trigger delay and a cohort with patient-specific individualized trigger delay for contrast media timing with bolus tracking. Materials and Methods In this prospective study (January-August 2018), CT angiography of the thoracoabdominal aorta with bolus tracking was performed in two different study cohorts: one with a fixed trigger delay of 4 seconds (fixed cohort) and one with a patient-specific trigger delay (individualized cohort). All CT and contrast media protocol parameters were kept identical among cohorts. Objective image quality was evaluated by one reader; two readers assessed subjective image quality. Student t test was used to test for differences in mean attenuation; the Wilcoxon-Mann-Whitney test was used to test for differences in noise, contrast-to-noise ratio, and subjective image quality. Results The fixed cohort had 108 study participants (16 women; mean age ± standard deviation, 72 years ± 10); the individualized cohort had 108 participants (16 women; mean age, 72 years ± 12). The trigger delay in the individualized cohort ranged from 6.4-11.3 seconds (mean, 9.2 seconds). There was higher overall attenuation in the individualized cohort than in the fixed cohort (486 HU ± 92 for individualized vs 438 HU ± 99 for fixed; P < .001), with increasing differences from the aortic arch (8 HU) to the iliac arteries (95 HU). The regression model indicated uniform attenuation in the individualized cohort and decreasing attenuation in the fixed cohort (decrease of 87 HU by the iliac arteries; P < .001). There was no difference between cohorts for image noise (20 vs 19; P = .41), but contrast-to-noise ratio (21 vs 19; P = .04) and subjective image quality were higher in the individualized cohort than in the fixed cohort (excellent or good image quality, 100% vs 67%; P < .001). Conclusion Compared with a fixed delay time after bolus tracking, a patient-specific individualized trigger delay improves image quality and provides uniform contrast attenuation for CT angiography of the aorta. ©RSNA, 2019.


Assuntos
Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Aortografia/métodos , Feminino , Humanos , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
8.
Proc Natl Acad Sci U S A ; 113(19): 5227-32, 2016 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-27114515

RESUMO

The bony pelvis of adult humans exhibits marked sexual dimorphism, which is traditionally interpreted in the framework of the "obstetrical dilemma" hypothesis: Giving birth to large-brained/large-bodied babies requires a wide pelvis, whereas efficient bipedal locomotion requires a narrow pelvis. This hypothesis has been challenged recently on biomechanical, metabolic, and biocultural grounds, so that it remains unclear which factors are responsible for sex-specific differences in adult pelvic morphology. Here we address this issue from a developmental perspective. We use methods of biomedical imaging and geometric morphometrics to analyze changes in pelvic morphology from late fetal stages to adulthood in a known-age/known-sex forensic/clinical sample. Results show that, until puberty, female and male pelves exhibit only moderate sexual dimorphism and follow largely similar developmental trajectories. With the onset of puberty, however, the female trajectory diverges substantially from the common course, resulting in rapid expansion of obstetrically relevant pelvic dimensions up to the age of 25-30 y. From 40 y onward females resume a mode of pelvic development similar to males, resulting in significant reduction of obstetric dimensions. This complex developmental trajectory is likely linked to the pubertal rise and premenopausal fall of estradiol levels and results in the obstetrically most adequate pelvic morphology during the time of maximum female fertility. The evidence that hormones mediate female pelvic development and morphology supports the view that solutions of the obstetrical dilemma depend not only on selection and adaptation but also on developmental plasticity as a response to ecological/nutritional factors during a female's lifetime.


Assuntos
Envelhecimento/fisiologia , Modelos Biológicos , Ossos Pélvicos/crescimento & desenvolvimento , Pelve/anatomia & histologia , Pelve/crescimento & desenvolvimento , Gravidez/fisiologia , Adaptação Fisiológica/fisiologia , Adolescente , Adulto , Envelhecimento/patologia , Tamanho Corporal/fisiologia , Criança , Pré-Escolar , Medicina Baseada em Evidências , Feminino , Humanos , Lactente , Pessoa de Meia-Idade , Ossos Pélvicos/anatomia & histologia , Adulto Jovem
9.
Europace ; 20(7): e105-e114, 2018 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-29016813

RESUMO

Aims: Left atrial appendage (LAA) occlusion has emerged as an interesting alternative to oral anticoagulation (OAC) for stroke prevention in patients with atrial fibrillation (AF). We report the safety, efficacy, and durability of concomitant device-enabled epicardial LAA occlusion during open-heart surgery. In addition to long-term follow-up, we evaluate the impact on stroke risk in this selected population. Methods and results: A total of 291 AtriClip devices were deployed epicardially in patients (mean CHA2DS2-VASc-Score: 3.1 ± 1.5) undergoing open-heart surgery (including isolated coronary artery bypass grafting, valve, or combined procedures) comprising of forty patients from a first-in-man device trial (NCT00567515) and 251 patients from a consecutive institutional registry thereafter. In all patients (n = 291), the LAA was successfully excluded and overall mean follow-up (FU) was 36 ± 23months (range: 1-97 months). No device-related complications were detected throughout the FU period. Long-term imaging work-up (computed tomography) in selected patients ≥5years post-implant (range: 5.1-8.1 years) displayed complete LAA occlusion with no signs of residual reperfusion or significant LAA stumps. Subgroup analysis of patients with discontinued OAC during FU (n = 166) revealed a relative risk reduction of 87.5% with an observed ischaemic stroke-rate of 0.5/100 patient-years compared with what would have been expected in a group of patients with similar CHA2DS2-VASc scores (expected rate of 4.0/100 patient-years). No strokes occurred in the subgroup with OAC. Conclusion: The long-term results from our first-in-man prospective human trial plus our institutional registry of epicardial LAA occlusion with the AtriClip in patients with AF undergoing cardiac surgery demonstrate the safety and durability of the procedure. In addition, our data are suggestive for the potential efficacy of LAA occlusion in reducing the incidence of stroke. If validated in future large randomized trials, routine LAA occlusion in patients undergoing cardiac surgery (with contraindications to treatment with oral anticoagulants) may represent a reasonable adjunct procedure to reduce the risk of future stroke. Clinical Trial Registration: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00567515.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/instrumentação , Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Pericárdio/cirurgia , Acidente Vascular Cerebral/prevenção & controle , Adulto , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Feminino , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/mortalidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Pericárdio/fisiopatologia , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
10.
Neuroradiology ; 60(3): 281-291, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29356855

RESUMO

PURPOSE: To compare and to combine iterative metal artifact reduction (MAR) and virtual monoenergetic extrapolations (VMEs) from dual-energy computed tomography (DECT) for reducing metal artifacts from intracranial clips and coils. METHODS: Fourteen clips and six coils were scanned in a phantom model with DECT at 100 and 150SnkVp. Four datasets were reconstructed: non-corrected images (filtered-back projection), iterative MAR, VME from DECT at 120 keV, and combined iterative MAR + VME images. Artifact severity scores and visibility of simulated, contrast-filled, adjacent vessels were assessed qualitatively and quantitatively by two independent, blinded readers. RESULTS: Iterative MAR, VME, and combined iterative MAR + VME resulted in a significant reduction of qualitative (p < 0.001) and quantitative clip artifacts (p < 0.005) and improved the visibility of adjacent vessels (p < 0.05) compared to non-corrected images, with lowest artifact scores found in combined iterative MAR + VME images. Titanium clips demonstrated less artifacts than Phynox clips (p < 0.05), and artifact scores increased with clip size. Coil artifacts increased with coil size but were reducible when applying iterative MAR + VME compared to non-corrected images. However, no technique improved the severe artifacts from large, densely packed coils. CONCLUSIONS: Combining iterative MAR with VME allows for an improved metal artifact reduction from clips and smaller, loosely packed coils. Limited value was found for large and densely packed coils.


Assuntos
Artefatos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Próteses e Implantes , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Humanos , Metais , Imagens de Fantasmas
11.
Acta Radiol ; 59(11): 1309-1315, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29486599

RESUMO

Background Computed tomography (CT) for excluding acute aortic syndrome (AAS) and pulmonary embolism (PE) simultaneously in patients with chest pain could be used to exclude coronary artery disease (CAD). Purpose To evaluate the frequency of further testing for CAD in patients receiving a CT in the emergency department (ED) for simultaneous evaluation for AAS and PE. Material and Methods This retrospective study was conducted over a three-year period including all patients with acute chest pain visiting our ED. All patients were included that received an electrocardiography (ECG)-gated CT of the entire chest enquiring simultaneously for AAS and PE. Those patients were followed up for 30 days after their initial ED visit whether they received further testing for CAD. Results Within the study period, a total of 157 patients with acute chest pain received a chest pain CT for simultaneous evaluation of both AAS and PE. Image quality was deemed sufficient to evaluate the coronary arteries in 80% of the patients. Thirty-seven patients (24%) underwent additional testing for CAD within 30 days of their ED visit, including catheter coronary angiography (n = 25), cardiac-stress single-photon emission-CT (n = 6), and cardiac magnetic resonance imaging (MRI) (n = 6). Conclusion Of patients presenting to the ED with acute chest pain who received a chest pain CT for simultaneous evaluation of AAS and PE, 24% had further imaging for CAD within 30 days of the initial ED visit. Immediate evaluation of the coronary arteries as part of a chest pain CT should be considered here for not delaying diagnosis.


Assuntos
Dor no Peito/etiologia , Dor no Peito/fisiopatologia , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Serviço Hospitalar de Emergência , Adulto , Idoso , Idoso de 80 Anos ou mais , Dor no Peito/diagnóstico por imagem , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
12.
Curr Oncol ; 31(1): 521-534, 2024 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-38248121

RESUMO

This study aimed to compare the detection of neuroendocrine tumor liver metastases (NLMs) in hepatobiliary-specific contrast-enhanced MRI (pMR) versus 68Ga-DOTATATE PET/CT (DT-PET). This retrospective study cohort included 30 patients with well-differentiated neuroendocrine tumors who underwent both DT-PET and pMR. Two readers independently assessed NLMs count, SUVmax on DT-PET, and signal characteristics on pMR. A consensus review by two additional readers resolved discrepancies between the modalities. Results showed concordance between DT-PET and pMR NLM count in 14/30 patients (47%). pMR identified more NLMs in 12/30 patients (40%), of which 4 patients showed multiple deposits on pMR but only 0-1 lesions on DT-PET. DT-PET detected more in 4/30 patients (13%). Overall, pMR detected more metastases than DT-PET (p = 0.01). Excluding the four outliers, there was excellent agreement between the two methods (ICC: 0.945, 95%CI: 0.930, 0.958). Notably, pMR had a higher NLM detection rate than DT-PET, with correlations found between lesion size on pMR and DT-PET detectability, as well as diffusion restriction on pMR and SUVmax on DT-PET. In conclusion, in consecutive patients with well-differentiated NETs, the detection rate of NLM is higher with pMR than with DT-PET. However, when excluding patients whose tumors do not overexpress somatostatin receptors (13% of the cohort), high concordance in the detection of NLM is observed between DT PET and pMR.


Assuntos
Gadolínio DTPA , Neoplasias Hepáticas , Tumores Neuroendócrinos , Tomografia por Emissão de Pósitrons , Cintilografia , Humanos , Radioisótopos de Gálio , Tumores Neuroendócrinos/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Elétrons , Estudos Retrospectivos , Imageamento por Ressonância Magnética , Neoplasias Hepáticas/diagnóstico por imagem
13.
Diagnostics (Basel) ; 14(11)2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38893731

RESUMO

We aimed to determine if clinical parameters and radiomics combined with sarcopenia status derived from baseline 18F-FDG-PET/CT could predict developing metastatic disease and overall survival (OS) in gastroesophageal cancer (GEC). Patients referred for primary staging who underwent 18F-FDG-PET/CT from 2008 to 2019 were evaluated retrospectively. Overall, 243 GEC patients (mean age = 64) were enrolled. Clinical, histopathology, and sarcopenia data were obtained, and primary tumor radiomics features were extracted. For classification (early-stage vs. advanced disease), the association of the studied parameters was evaluated. Various clinical and radiomics models were developed and assessed. Accuracy and area under the curve (AUC) were calculated. For OS prediction, univariable and multivariable Cox analyses were performed. The best model included PET/CT radiomics features, clinical data, and sarcopenia score (accuracy = 80%; AUC = 88%). For OS prediction, various clinical, CT, and PET features entered the multivariable analysis. Three clinical factors (advanced disease, age ≥ 70 and ECOG ≥ 2), along with one CT-derived and one PET-derived radiomics feature, retained their significance. Overall, 18F-FDG PET/CT radiomics seems to have a potential added value in identifying GEC patients with advanced disease and may enhance the performance of baseline clinical parameters. These features may also have a prognostic value for OS, improving the decision-making for GEC patients.

14.
Acad Radiol ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38997880

RESUMO

RATIONALE AND OBJECTIVES: To investigate whether [18F]-FDG PET/CT-derived radiomics may correlate with driver gene mutations in non-small cell lung cancer (NSCLC) patients. MATERIALS AND METHODS: In this IRB-approved retrospective study, 203 patients with surgically treated NSCLC who underwent subsequent genomic analysis of the primary tumour at our institution between December 2004 and January 2014 were identified. Of those, 128 patients (mean age 62.4 ± 10.8 years; range: 35-84) received preoperative [18F]-FDG PET/CT as part of their initial staging and thus were included in the study. PET and CT image segmentation and feature extraction were performed semi-automatically with an open-source software platform (LIFEx, Version 6.30, lifexsoft.org). Molecular profiles using different next-generation sequencing (NGS) panels were collected from a web-based resource (cBioPortal.ca for Cancer genomics). Two statistical models were then built to evaluate the predictive ability of [18F]-FDG PET/CT-derived radiomics features for driver gene mutations in NSCLC. RESULTS: More than half (68/128, 53%) of all tumour samples harboured three or more gene mutations. Overall, 55% of tumour samples demonstrated a mutation in TP53, 26% of samples had alterations in KRAS and 17% in EGFR. Extensive statistical analysis resulted in moderate to good predictive ability. The highest Youden Index for TP53 was achieved using combined PET/CT features (0.70), for KRAS using PET features only (0.57) and for EGFR using CT features only (0.60). CONCLUSION: Our study demonstrated a moderate to good correlation between radiomics features and driver gene mutations in NSCLC, indicating increased predictive ability of genomic profiles using combined [18F]-FDG PET/CT-derived radiomics features.

15.
Cancers (Basel) ; 16(10)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38791955

RESUMO

We aimed to investigate whether [18F]F-FDG-PET/CT-derived radiomics can classify histologic subtypes and determine the anatomical origin of various malignancies. In this IRB-approved retrospective study, 391 patients (age = 66.7 ± 11.2) with pulmonary (n = 142), gastroesophageal (n = 128) and head and neck (n = 121) malignancies were included. Image segmentation and feature extraction were performed semi-automatically. Two models (all possible subset regression [APS] and recursive partitioning) were employed to predict histology (squamous cell carcinoma [SCC; n = 219] vs. adenocarcinoma [AC; n = 172]), the anatomical origin, and histology plus anatomical origin. The recursive partitioning algorithm outperformed APS to determine histology (sensitivity 0.90 vs. 0.73; specificity 0.77 vs. 0.65). The recursive partitioning algorithm also revealed good predictive ability regarding anatomical origin. Particularly, pulmonary malignancies were identified with high accuracy (sensitivity 0.93; specificity 0.98). Finally, a model for the synchronous prediction of histology and anatomical disease origin resulted in high accuracy in determining gastroesophageal AC (sensitivity 0.88; specificity 0.92), pulmonary AC (sensitivity 0.89; specificity 0.88) and head and neck SCC (sensitivity 0.91; specificity 0.92). Adding PET-features was associated with marginal incremental value for both the prediction of histology and origin in the APS model. Overall, our study demonstrated a good predictive ability to determine patients' histology and anatomical origin using [18F]F-FDG-PET/CT-derived radiomics features, mainly from CT.

16.
Cancers (Basel) ; 15(7)2023 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-37046757

RESUMO

Lung cancer remains the leading cancer-related death across North America. Imaging is fundamental. Recently, healthcare disparities came into research focus. Our aim was to explore disparity from an imaging, genetic, and outcome perspective. We utilized the AACR Project GENIE Biopharma Consortium (BPC) dataset v 1.1 to build a collated NSCLC dataset. Descriptive and analytical statistics were applied according to data characteristics. From 1849 patients, mean age was 64.4 y (±10.5), 58% (n = 1065) were female, 23% (n = 419) never smoked, 84% (n = 1545) were of white race, and 57% (n = 1052) were < stage III. No difference (p > 0.05) was found for baseline imaging by race. White race showed higher 3-month surveillance imaging (p = 0.048) and a baseline stage < IV (OR 0.61). KRAS (33.3 vs. 17.9%), STK11 (14.8 vs. 7.3%), and KEAP1 (13.3 vs. 5.3%) mutations were predominant among white patients while EGFR mutation (19.2 vs. 44.1%) was less predominant. Mutations in TP53 or KEAP1 had worse PFS and OS. The latter was also reduced in STK11, KRAS + STK11, and KRAS + KEAP1 mutations. Meanwhile, EGFR mutation had increased OS. Multivariate analysis showed that progression on imaging at 3 or 6 months (HR 1.69 and 1.43, respectively), TP53 (HR 1.37) and KRAS (HR 1.26) had lower OS while EGFR and LRP1B (HR 0.69 and 0.39, respectively) had higher OS. No racial disparity at baseline imaging was observed. Higher initial stages among non-white patients might reflect inequalities in accessing healthcare. However, race wasn't associated to OS. Finally, progression in imaging at 3 or 6 months showed the higher hazard ratios for death.

17.
Diagnostics (Basel) ; 13(5)2023 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-36899982

RESUMO

We investigated the prognostic value of sarcopenia measurements and metabolic parameters of primary tumors derived from 18F-FDG-PET/CT among patients with primary, metastatic esophageal and gastroesophageal cancer. A total of 128 patients (26 females; 102 males; mean age 63.5 ± 11.7 years; age range: 29-91 years) with advanced metastatic gastroesophageal cancer who underwent 18F-FDG-PET/CT as part of their initial staging between November 2008 and December 2019 were included. Mean and maximum standardized uptake value (SUV) and SUV normalized by lean body mass (SUL) were measured. Skeletal muscle index (SMI) was measured at the level of L3 on the CT component of the 18F-FDG-PET/CT. Sarcopenia was defined as SMI < 34.4 cm2/m2 in women and <45.4 cm2/m2 in men. A total of 60/128 patients (47%) had sarcopenia on baseline 18F-FDG-PET/CT. Mean SMI in patients with sarcopenia was 29.7 cm2/m2 in females and 37.5 cm2/m2 in males. In a univariable analysis, ECOG (<0.001), bone metastases (p = 0.028), SMI (p = 0.0075) and dichotomized sarcopenia score (p = 0.033) were significant prognostic factors for overall survival (OS) and progression-free survival (PFS). Age was a poor prognostic factor for OS (p = 0.017). Standard metabolic parameters were not statistically significant in the univariable analysis and thus were not evaluated further. In a multivariable analysis, ECOG (p < 0.001) and bone metastases (p = 0.019) remained significant poor prognostic factors for OS and PFS. The final model demonstrated improved OS and PFS prognostication when combining clinical parameters with imaging-derived sarcopenia measurements but not metabolic tumor parameters. In summary, the combination of clinical parameters and sarcopenia status, but not standard metabolic values from 18F-FDG-PET/CT, may improve survival prognostication in patients with advanced, metastatic gastroesophageal cancer.

19.
Cancers (Basel) ; 14(24)2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36551709

RESUMO

We investigate whether computed tomography (CT) derived radiomics may correlate with driver gene mutations in patients with pancreatic ductal adenocarcinoma (PDAC). In this retrospective study, 47 patients (mean age 64 ± 11 years; range: 42-86 years) with PDAC, who were treated surgically and who underwent preoperative CT imaging at our institution were included in the study. Image segmentation and feature extraction was performed semi-automatically with a commonly used open-source software platform. Genomic data from whole genome sequencing (WGS) were collected from our institution's web-based resource. Two statistical models were then built, in order to evaluate the predictive ability of CT-derived radiomics feature for driver gene mutations in PDAC. 30/47 of all tumor samples harbored 2 or more gene mutations. Overall, 81% of tumor samples demonstrated mutations in KRAS, 68% of samples had alterations in TP53, 26% in SMAD4 and 19% in CDKN2A. Extended statistical analysis revealed acceptable predictive ability for KRAS and TP53 (Youden Index 0.56 and 0.67, respectively) and mild to acceptable predictive signal for SMAD4 and CDKN2A (Youden Index 0.5, respectively). Our study establishes acceptable correlation of radiomics features and driver gene mutations in PDAC, indicating an acceptable prognostication of genomic profiles using CT-derived radiomics. A larger and more homogenous cohort may further enhance the predictive ability.

20.
Front Oncol ; 12: 952763, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36353565

RESUMO

Purpose: Radiomics is an emerging imaging assessment technique that has shown promise in predicting survival among nasopharyngeal carcinoma (NPC) patients. Studies so far have focused on PET or MR-based radiomics independently. The aim of our study was to evaluate the prognostic value of clinical and radiomic parameters derived from both PET/CT and MR. Methods: Retrospective evaluation of 124 NPC patients with PET/CT and radiotherapy planning MR (RP-MR). Primary tumors were segmented using dedicated software (LIFEx version 6.1) from PET, CT, contrast-enhanced T1-weighted (T1-w), and T2-weighted (T2-w) MR sequences with 376 radiomic features extracted. Summary statistics describe patient, disease, and treatment characteristics. The Kaplan-Meier (KM) method estimates overall survival (OS) and progression-free survival (PFS). Clinical factors selected based on univariable analysis and the multivariable Cox model were subsequently constructed with radiomic features added. Results: The final models comparing clinical, clinical + RP-MR, clinical + PET/CT and clinical + RP-MR + PET/CT for OS and PFS demonstrated that combined radiomic signatures were significantly associated with improved survival prognostication (AUC 0.62 vs 0.81 vs 0.75 vs 0.86 at 21 months for PFS and 0.56 vs 0.85 vs 0.79 vs 0.96 at 24 months for OS). Clinical + RP-MR features initially outperform clinical + PET/CT for both OS and PFS (<18 months), and later in the clinical course for PFS (>42 months). Conclusion: Our study demonstrated that PET/CT-based radiomic features may improve survival prognostication among NPC patients when combined with baseline clinical and MR-based radiomic features.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA