Magn Reson Med ; 71(4): 1374-80, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24453116

RESUMO

PURPOSE: To develop a technique that accurately detects the QRS complex in 1.5 Tesla (T), 3T, and 7T MRI scanners. METHODS: During early systole, blood is rapidly ejected into the aortic arch, traveling perpendicular to the MRI's main field, which produces a strong voltage (V(MHD)) that eclipses the QRS complex. Greater complexity arises in arrhythmia patients, since V(MHD) varies between sinus-rhythm and arrhythmic beats. The 3DQRS method uses a kernel consisting of 6 electrocardiogram (ECG) precordial leads (V1-V6), compiled from a 12-lead ECG performed outside the magnet. The kernel is cross-correlated with signals acquired inside the MRI to identify the QRS complex in real time. The 3DQRS method was evaluated against a vectorcardiogram (VCG)-based approach in two premature ventricular contraction (PVC) and two atrial fibrillation (AF) patients, a healthy exercising athlete, and eight healthy volunteers, within 1.5T and 3T MRIs, using a prototype MRI-conditional 12-lead ECG system. Two volunteers were recorded at 7T using a Holter recorder. RESULTS: For QRS complex detection, 3DQRS subject-averaged sensitivity levels, relative to VCG were: 1.5T (100% versus 96.7%), 3T (98.9% versus 92.2%), and 7T (96.2% versus 77.7%). CONCLUSION: The 3DQRS method was shown to be more effective in cardiac gating than a conventional VCG-based method.


Assuntos
Algoritmos , Artefatos , Mapeamento Potencial de Superfície Corporal/métodos , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Frequência Cardíaca/fisiologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Proc Inst Mech Eng H ; 237(3): 297-308, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36704957

RESUMO

Magnetically steerable catheters (MSCs) have caught the interest of researchers due to their various potential uses in clinical applications, for example, minimally invasive surgery. Many significant advances in the design, implementation and analysis of MSCs have been accomplished in the last decade. This review concentrates on the configurations of current MSCs with an in depth look at control of the device and the specific workspace. This review also evaluates MSCs and references possible future system designs and difficulties. The concept of magnetic manipulation is briefly presented. Then, by category, the MSC is introduced. Following that, a discussion of future works and challenges of the review systems is provided. The conclusions are finally addressed.


Assuntos
Catéteres , Procedimentos Cirúrgicos Minimamente Invasivos , Desenho de Equipamento
3.
Int J Med Robot ; 17(2): e2235, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33497520

RESUMO

BACKGROUND: Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease with no cure and limited treatment options. Recent studies have shown that delivering cellular therapeutics to the ventral horn of the spinal cord can effectively halt neurodegeneration associated with ALS in small animal models. METHODS: We developed a robotic system that assists with MRI-guided percutaneous injections to the spinal cord. The needle positioning robot consists of two linear axes with motorised translational sleds for two-degree-of-freedom (2-DOF) needle translation and a radial template for 2-DOF discrete rotation. RESULTS: The robot's targeting capability, evaluated using phantom models and swine cadavers, showed mean targeting errors of 0.48 and 2.84 mm, respectively. The duration of the targeting procedure is approximately 60 min, with an extra 10 min for each additional injection. CONCLUSIONS: The presented robot does not affect imaging quality during MRI-guided procedures, and it enables a simplified workflow for MRI-guided spinal therapy.


Assuntos
Doenças Neurodegenerativas , Procedimentos Cirúrgicos Robóticos , Medula Espinal , Animais , Imageamento por Ressonância Magnética , Agulhas , Imagens de Fantasmas , Suínos
4.
Circ Cardiovasc Imaging ; 8(12)2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26628581

RESUMO

BACKGROUND: To develop a technique to noninvasively estimate stroke volume in real time during magnetic resonance imaging (MRI)-guided procedures, based on induced magnetohydrodynamic voltages (VMHD) that occur in ECG recordings during MRI exams, leaving the MRI scanner free to perform other imaging tasks. Because of the relationship between blood flow (BF) and VMHD, we hypothesized that a method to obtain stroke volume could be derived from extracted VMHD vectors in the vectorcardiogram (VCG) frame of reference (VMHDVCG). METHODS AND RESULTS: To estimate a subject-specific BF-VMHD model, VMHDVCG was acquired during a 20-s breath-hold and calibrated versus aortic BF measured using phase-contrast magnetic resonance in 10 subjects (n=10) and 1 subject diagnosed with premature ventricular contractions. Beat-to-beat validation of VMHDVCG-derived BF was performed using real-time phase-contrast imaging in 7 healthy subjects (n=7) during 15-minute cardiac exercise stress tests and 30 minutes after stress relaxation in 3T MRIs. Subject-specific equations were derived to correlate VMHDVCG with BF at rest and validated using real-time phase-contrast. An average error of 7.22% and 3.69% in stroke volume estimation, respectively, was found during peak stress and after complete relaxation. Measured beat-to-beat BF time history derived from real-time phase-contrast and VMHD was highly correlated using a Spearman rank correlation coefficient during stress tests (0.89) and after stress relaxation (0.86). CONCLUSIONS: Accurate beat-to-beat stroke volume and BF were estimated using VMHDVCG extracted from intra-MRI 12-lead ECGs, providing a means to enhance patient monitoring during MR imaging and MR-guided interventions.


Assuntos
Eletrocardiografia , Frequência Cardíaca , Imagem Cinética por Ressonância Magnética , Volume Sistólico , Função Ventricular Esquerda , Complexos Ventriculares Prematuros/diagnóstico , Estudos de Casos e Controles , Teste de Esforço , Humanos , Interpretação de Imagem Assistida por Computador , Modelos Cardiovasculares , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Complexos Ventriculares Prematuros/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA