Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Breast J ; 26(5): 991-994, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32166836

RESUMO

Guidelines for high-risk screening with MRI were introduced by the American Cancer Society in 2007, based on superior sensitivity of MRI over mammography, albeit without proven mortality reduction. The mortality end point is still unconfirmed, but international data are maturing with improved survival apparent, albeit subject to lead time and length bias. In this observational study of survival, we review 41 consecutive patients whose cancers (85.3% invasive) were detected through 2039 asymptomatic MRI screenings. With a minimum follow-up of 5 years and median follow-up of 10.2 years (range: 5.0-15.1), disease-specific survival is 100%.


Assuntos
Neoplasias da Mama , Mama , Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer , Feminino , Humanos , Imageamento por Ressonância Magnética , Mamografia , Programas de Rastreamento , Estudos Observacionais como Assunto
2.
J Magn Reson Imaging ; 44(5): 1099-1106, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27080203

RESUMO

PURPOSE: To develop a new quantitative global kinetic breast magnetic resonance imaging (MRI) features analysis scheme and assess its feasibility to assess tumor response to neoadjuvant chemotherapy. MATERIALS AND METHODS: A dataset involving breast MR images acquired from 151 cancer patients before neoadjuvant chemotherapy was used. Among them, 63 patients had complete response (CR) and 88 had partial response (PR) to chemotherapy based on the RECIST criterion. A computer-aided detection (CAD) scheme was applied to segment breast region depicted on the breast MR images and computed a total of 10 kinetic image features to represent parenchyma enhancement either from the entire two breasts or the bilateral asymmetry between the two breasts. To classify between CR and PR cases, we tested an attribution selected classifier that integrates with an artificial neural network and a Wrapper Subset Evaluator. The classifier was trained and tested using a leave-one-case-out (LOCO)-based cross-validation method. The area under a receiver operating characteristic curve (AUC) was computed to assess classifier performance. RESULTS: From the pool of initial 10 features, four features were selected by more than 90% times in the LOCO cross-validation iterations. Among them, three represent the bilateral asymmetry of kinetic features between two breasts. Using the classifier yielded AUC = 0.83 ± 0.04, which is significantly higher than using each individual feature to classify between CR and PR cases (P < 0.05). CONCLUSION: This study demonstrated that quantitative analysis of global kinetic features computed from breast MRI-acquired prechemotherapy has potential to generate a useful clinical marker that is associated with tumor response to neoadjuvant chemotherapy. J. Magn. Reson. Imaging 2016;44:1099-1106.


Assuntos
Antineoplásicos/uso terapêutico , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Monitoramento de Medicamentos/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Adulto , Idoso , Neoplasias da Mama/patologia , Quimioterapia Adjuvante , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Aprendizado de Máquina , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
3.
Breast J ; 20(2): 192-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24387050

RESUMO

Current guidelines for adding breast MRI to annual screening mammography are based entirely upon stratification of risk, with a heavy focus on lifetime calculations. This approach is fraught with difficulty due to the reliance on mathematical models that vary widely in their calculations, the inherent age discrimination of using lifetime risks rather than short-term incidence, and the failure to incorporate mammographic density, the latter being an independent risk as well as the greatest predictor of mammographic failure. By utilizing a system of patient selection similar to what was used in the American College of Radiology Imaging Network (ACRIN) 6666 trial for multi-modality imaging, 33 women without a prior diagnosis of breast cancer were found to harbor mammographically occult carcinoma through MRI screening. These 33 patients represent a 2% yield, closely approximating the yields seen in prospective MRI screening trials of women at very high risk of breast cancer. Using the "~20-25%" minimum established by the American Cancer Society and later the National Comprehensive Cancer Network, the Gail model would have prompted the use of MRI in only 9 of 33 (27.3%) patients, the Claus model 1 of 33 (3%), and the Tyrer-Cuzick model 12 of 33 (36.4%). Using all three models and opting for the highest calculated risk, then including BRCA-positivity, still would have identified only 16 of 33 (48.5%) patients with occult breast cancer discovered by MRI. Only one patient was BRCA-positive, and none had lobular carcinoma in situ, while 6 of 33 patients (18.2%) had atypical ductal hyperplasia (ADH). Measures are proposed to refine patient selection for MRI screening through the use of short-term or categorical risks, mammographic density, while maintaining cost-effectiveness through longer MRI screening intervals.


Assuntos
Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética , Medição de Risco/métodos , Adulto , Idoso , Densidade da Mama , Neoplasias da Mama/genética , Neoplasias da Mama/patologia , Carcinoma Intraductal não Infiltrante/diagnóstico , Carcinoma Intraductal não Infiltrante/genética , Carcinoma Intraductal não Infiltrante/patologia , Carcinoma Lobular/diagnóstico , Carcinoma Lobular/patologia , Feminino , Genes BRCA1 , Genes BRCA2 , Testes Genéticos , Humanos , Glândulas Mamárias Humanas/anormalidades , Programas de Rastreamento , Pessoa de Meia-Idade , Imagem Multimodal , Seleção de Pacientes
6.
Cureus ; 15(4): e37109, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37168218

RESUMO

Guidelines for breast cancer screening with MRI were first proposed in 2007, only a few years after its clinical introduction. Those initial guidelines, which were generated by a committee sponsored by the American Cancer Society (ACS), have served as the template for similar recommendations by several organizations, with a singular goal regarding patient candidacy for MRI screening, a qualifying threshold based on risk stratification. Higher risk in those patients recommended for MRI screening translates to higher cancer detection rates, which in turn impacts cost-effectiveness. But there is another variable that should be as important as risk stratification in selecting patients for MRI screening: the probability that screening mammography will fail to detect developing cancer. That failure rate is a function of breast density, included in the MRI screening guidelines as a traditional risk factor but neglected when one considers its role as the primary cause of false-negative mammograms. The two implications of dense mammograms are essentially independent: (1) refining risk stratification and (2) predicting the "miss rate" of mammography. In the 2007 guidelines, indications for annual screening MRI, in addition to mammography, were based on patients having a calculated probability of "greater than 20-25% lifetime risk" for developing breast cancer. Other categorical risks, such as BRCA positivity, are listed in the ACS guidelines, but in effect, the threshold for adding MRI to the screening regimen has been a 20% lifetime risk for the development of breast cancer. While risk stratification in the original MRI screening guidelines had a number of inconsistencies, the focus herein is the questionable placement of high-density patients into the category described as "no policy for or against MRI, more research needed," a category where lifetime risks were grouped as 15-19%. Thus, mammographic density was relegated to its role as a traditional risk factor, while its potentially more significant impact, predicting the "miss rate" of mammography, had no role in patient selection for screening MRI. The 2007 ACS guideline committee was limited by the lack of available data, and since there was no evidence for mortality reduction at the time, the decision was made to follow the patient selection criteria that had been used in the six international MRI screening trials, even though there was little consistency among those trials. Since then, the number of screening MRI trials has more than doubled, and new trials are being designed and implemented with a focus on both features of density: risk and cancer camouflage. Enough evidence has accumulated during the 16 years subsequent to the original ACS high-risk screening guidelines to consider a complete revision that accounts for both numerical risk levels and density levels, much like what was used in the ACRIN 6666 trial. In establishing a new set of guidelines, our first question should be: What is the "miss rate" of mammography in this patient? If the chance of a false-negative mammogram is as high as we see with Level D density, then the decision to include MRI becomes straightforward. The traditional risk assessment would then be used to help determine the optimal interval between MRI screens while maintaining cost-effective cancer detection rates.

7.
Radiology ; 265(1): 51-8, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22923716

RESUMO

PURPOSE: To assess diagnostic performance of dedicated breast magnetic resonance (MR) imaging at breast imaging centers by using a dedicated 1.5-T breast MR system that used high-spatial-resolution, high-contrast-resolution spiral trajectory acquisitions. MATERIALS AND METHODS: The study was institutional review board approved and HIPAA compliant, with waiver of informed consent. Diagnostic performance was retrospectively assessed for 934 consecutive screening (n=347) and diagnostic (n=587) examinations performed from April 2006 to December 2007 in women aged 25-89 years old from four sites for which dedicated breast MR imaging reports and ground truth (biopsy for cancer cases, 1-year follow-up with negative results for cases with negative findings) were available. The sensitivity, specificity, and receiver operating characteristic (ROC) for breast MR imaging were determined. RESULTS: The sensitivity and specificity for the dedicated breast MR imaging system were 92% (92 of 100) and 88.8% (741 of 834). For all cases, the negative predictive value (NPV) was 98.9% (741 of 749). The NPV for screening cases was 100% (326 of 326). The area under the ROC curve was 0.942. Of the 93 cases with false-positive findings seen at dedicated breast MR imaging, 25 (27%) were high-risk histologic findings for which excision is often recommended. The false-positive rate was 93 of 834 (11.2%) for all cases, but only 16 of 326 (4.9%) for the screening cohort. CONCLUSION: High accuracy was achieved by using dedicated breast MR imaging.


Assuntos
Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Neoplasias da Mama/patologia , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade
8.
Breast J ; 18(5): 420-7, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22804792

RESUMO

Preoperative breast MRI in newly diagnosed cancer patients has several potential benefits. Improved survival for patients with invasive disease as the index lesion is unlikely to be one of these benefits, given what is known from variations in locoregional management in the historic conservation trials. However, this may not be the case for patients with ductal carcinoma in situ (DCIS), as the discovery of unsuspected invasive cancer located elsewhere from the biopsy-proven DCIS could result in decreased survival if left undetected and untreated. In support of this hypothesis, a previous observational study of a large cohort of DCIS patients revealed the development of invasive cancer to be the most common event after unilateral DCIS treatment, occurring in 3.9%, mostly in the opposite breast. These cancers appeared on mammography or clinical exam within a short time frame (median 2.9 years) and were associated with a diminution in survival. Given these second events occurring so soon after DCIS treatment, it must be considered that invasive cancers were present elsewhere, but mammographically occult, at the time of DCIS diagnosis. To examine this possibility, 288 consecutive patients with newly diagnosed DCIS underwent preoperative MRI, with the discovery of separate foci of invasive cancer, either multicentric or contralateral, occurring in 3.5% of patients, a similar incidence to the short-term observational study. These "elsewhere" invasive cancers are presented here with details of pathology such that both Stage I and Stage II disease can be seen as clinically significant, with the usual stage-based survival implications.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Carcinoma Intraductal não Infiltrante/diagnóstico , Carcinoma Intraductal não Infiltrante/patologia , Idoso , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Carcinoma Intraductal não Infiltrante/radioterapia , Carcinoma Intraductal não Infiltrante/cirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética , Mastectomia Segmentar , Pessoa de Meia-Idade , Período Pré-Operatório , Estudos Prospectivos
9.
IEEE Trans Med Imaging ; 39(4): 1235-1244, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31603818

RESUMO

This study aims to develop and evaluate a new computer-aided diagnosis (CADx) scheme based on analysis of global mammographic image features to predict likelihood of cases being malignant. An image dataset involving 1,959 cases was retrospectively assembled. Suspicious lesions were detected and biopsied in each case. Among them, 737 cases are malignant and 1,222 are benign. Each case includes four mammograms of craniocaudal and mediolateral oblique view of left and right breasts. CADx scheme is applied to pre-process mammograms, generate two image maps in frequency domain using discrete cosine transform and fast Fourier transform, compute bilateral image feature differences from left and right breasts, and apply a support vector machine (SVM) to predict likelihood of the case being malignant. Three sub-groups of image features were computed from the original mammograms and two transformation maps. Four SVMs using three sub-groups of image features and fusion of all features were trained and tested using a 10-fold cross-validation method. The computed areas under receiver operating characteristic curves (AUCs) range from 0.85 to 0.91 using image features computed from one of three sub-groups, respectively. By fusion of all image features computed in three sub-groups, the fourth SVM yields a significantly higher performance with AUC = 0.96±0.01 (p<0.01). This study demonstrates feasibility of developing a new global image feature analysis based CADx scheme of mammograms with high performance. By avoiding difficulty and possible errors in breast lesion segmentation, this new CADx approach is more efficient in development and potentially more robust in future application.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Curva ROC , Máquina de Vetores de Suporte
10.
Am J Surg ; 218(2): 411-418, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30739738

RESUMO

From its inception, screening mammography has enjoyed a perceived level of sensitivity that is inconsistent with available evidence. The original data that imparted erroneous beliefs about sensitivity were based on a variety of misleading definitions and approaches, such as the inclusion of palpable tumors, using the inverse of interval cancer rates (often tied to an arbitrary 12 month interval), and quoting prevalence screen sensitivity wherein tumors are larger than those found on incidence screens. This review addresses the background for the overestimation of mammographic sensitivity, and how a major adjustment in our thinking is overdue now that multi-modality imaging allows us to determine real time mammographic sensitivity. Although a single value for mammographic sensitivity is disingenuous, given the wide range based on background density, it is important to realize that a sensitivity gap between belief and reality still exists in the early detection of breast cancer using mammography alone, in spite of technologic advances. Failure to recognize this gap diminishes the acceptance of adjunct methods of breast imaging that greatly complement detection rates.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Mamografia/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Imagem Multimodal , Sensibilidade e Especificidade
11.
Comput Methods Programs Biomed ; 179: 104995, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31443864

RESUMO

BACKGROUND AND OBJECTIVE: This study aims to develop and evaluate a unique global mammographic image feature analysis scheme to predict likelihood of a case depicting the detected suspicious breast mass being malignant for breast cancer. METHODS: From the entire breast area depicting on the mammograms, 59 features were initially computed to characterize the breast tissue properties at both spatial and frequency domain. Given that each case consists of two cranio-caudal and two medio-lateral oblique view images of left and right breasts, two feature pools were built, which contain the computed features from either two positive images of one breast or all the four images of two breasts. Next, for each feature pool, a particle swarm optimization (PSO) method was applied to determine the optimal feature cluster followed by training a support vector machine (SVM) classifier to generate a final score for predicting likelihood of the case being malignant. To test the scheme, we assembled a dataset involving 275 patients who had biopsy due to the suspicious findings on mammograms. Among them, 134 are malignant and 141 are benign. A ten-fold cross validation method was used to train and test the scheme. RESULTS: The classification performance levels measured by the areas under ROC curves are 0.79 ± 0.07 and 0.75 ± 0.08 when applying the SVM classifiers trained using image features computed from two-view and four-view images, respectively. CONCLUSIONS: This study demonstrates feasibility of developing a new global mammographic image feature analysis-based scheme to predict the likelihood of case being malignant without lesion segmentation.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Densidade da Mama , Bases de Dados Factuais/estatística & dados numéricos , Feminino , Humanos , Mamografia/estatística & dados numéricos , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador/estatística & dados numéricos , Máquina de Vetores de Suporte
12.
Phys Med Biol ; 63(10): 105005, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29667606

RESUMO

This study aims to investigate the feasibility of identifying a new quantitative imaging marker based on false-positives generated by a computer-aided detection (CAD) scheme to help predict short-term breast cancer risk. An image dataset including four view mammograms acquired from 1044 women was retrospectively assembled. All mammograms were originally interpreted as negative by radiologists. In the next subsequent mammography screening, 402 women were diagnosed with breast cancer and 642 remained negative. An existing CAD scheme was applied 'as is' to process each image. From CAD-generated results, four detection features including the total number of (1) initial detection seeds and (2) the final detected false-positive regions, (3) average and (4) sum of detection scores, were computed from each image. Then, by combining the features computed from two bilateral images of left and right breasts from either craniocaudal or mediolateral oblique view, two logistic regression models were trained and tested using a leave-one-case-out cross-validation method to predict the likelihood of each testing case being positive in the next subsequent screening. The new prediction model yielded the maximum prediction accuracy with an area under a ROC curve of AUC = 0.65 ± 0.017 and the maximum adjusted odds ratio of 4.49 with a 95% confidence interval of (2.95, 6.83). The results also showed an increasing trend in the adjusted odds ratio and risk prediction scores (p < 0.01). Thus, this study demonstrated that CAD-generated false-positives might include valuable information, which needs to be further explored for identifying and/or developing more effective imaging markers for predicting short-term breast cancer risk.


Assuntos
Biomarcadores/análise , Neoplasias da Mama/diagnóstico , Mamografia/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Neoplasias da Mama/etiologia , Detecção Precoce de Câncer , Feminino , Humanos , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Fatores de Risco
13.
Phys Med Biol ; 63(3): 035020, 2018 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-29239858

RESUMO

In order to automatically identify a set of effective mammographic image features and build an optimal breast cancer risk stratification model, this study aims to investigate advantages of applying a machine learning approach embedded with a locally preserving projection (LPP) based feature combination and regeneration algorithm to predict short-term breast cancer risk. A dataset involving negative mammograms acquired from 500 women was assembled. This dataset was divided into two age-matched classes of 250 high risk cases in which cancer was detected in the next subsequent mammography screening and 250 low risk cases, which remained negative. First, a computer-aided image processing scheme was applied to segment fibro-glandular tissue depicted on mammograms and initially compute 44 features related to the bilateral asymmetry of mammographic tissue density distribution between left and right breasts. Next, a multi-feature fusion based machine learning classifier was built to predict the risk of cancer detection in the next mammography screening. A leave-one-case-out (LOCO) cross-validation method was applied to train and test the machine learning classifier embedded with a LLP algorithm, which generated a new operational vector with 4 features using a maximal variance approach in each LOCO process. Results showed a 9.7% increase in risk prediction accuracy when using this LPP-embedded machine learning approach. An increased trend of adjusted odds ratios was also detected in which odds ratios increased from 1.0 to 11.2. This study demonstrated that applying the LPP algorithm effectively reduced feature dimensionality, and yielded higher and potentially more robust performance in predicting short-term breast cancer risk.


Assuntos
Algoritmos , Neoplasias da Mama/diagnóstico , Mama/patologia , Aprendizado de Máquina , Mamografia/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Medição de Risco/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/diagnóstico por imagem , Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Adulto Jovem
15.
J Okla State Med Assoc ; 99(10): 505-15, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17125104

RESUMO

BACKGROUND: Magnetic resonance imaging of the breast is indicated in multiple settings, one of which is preoperative staging to establish tumor extent, multicentricity, and contralateral disease. METHODOLOGY: Results of conventional imaging, breast MRI, and pathology were analyzed from 334 patients who underwent breast MRI subsequent to a biopsy that confirmed primary breast malignancy. The focus of this retrospective study was imaging-histologic correlation. FINDINGS: Only 1.2% of patients with tumors mapped by MRI required re-operation after lumpectomy. Multicentricity was identified by MRI alone in 7.7% of patients, while 3.6% were found to have occult contralateral cancer. In 11 of the 12 patients with contralateral cancer, the lesion was invasive, with ductal histology in 9 of the 11. The sensitivity of mammography for detecting these contralateral cancers was only 22.2%. CONCLUSION: Preoperative breast MRI is recommended for mapping tumor extent and to discover additional primary lesions in newly diagnosed breast cancer patients.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Mama/patologia , Imageamento por Ressonância Magnética , Biópsia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Feminino , Humanos , Mamografia , Mastectomia , Mastectomia Segmentar , Recidiva Local de Neoplasia , Seleção de Pacientes , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Reoperação , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
16.
PLoS One ; 11(8): e0157692, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27508384

RESUMO

Despite significant advances in breast imaging, the ability to accurately detect Breast Cancer (BC) remains a challenge. With the discovery of key biomarkers and protein signatures for BC, proteomic technologies are currently poised to serve as an ideal diagnostic adjunct to imaging. Research studies have shown that breast tumors are associated with systemic changes in levels of both serum protein biomarkers (SPB) and tumor associated autoantibodies (TAAb). However, the independent contribution of SPB and TAAb expression data for identifying BC relative to a combinatorial SPB and TAAb approach has not been fully investigated. This study evaluates these contributions using a retrospective cohort of pre-biopsy serum samples with known clinical outcomes collected from a single site, thus minimizing potential site-to-site variation and enabling direct assessment of SPB and TAAb contributions to identify BC. All serum samples (n = 210) were collected prior to biopsy. These specimens were obtained from 18 participants with no evidence of breast disease (ND), 92 participants diagnosed with Benign Breast Disease (BBD) and 100 participants diagnosed with BC, including DCIS. All BBD and BC diagnoses were based on pathology results from biopsy. Statistical models were developed to differentiate BC from non-BC (i.e., BBD and ND) using expression data from SPB alone, TAAb alone, and a combination of SPB and TAAb. When SPB data was independently used for modeling, clinical sensitivity and specificity for detection of BC were 74.7% and 77.0%, respectively. When TAAb data was independently used, clinical sensitivity and specificity for detection of BC were 72.2% and 70.8%, respectively. When modeling integrated data from both SPB and TAAb, the clinical sensitivity and specificity for detection of BC improved to 81.0% and 78.8%, respectively. These data demonstrate the benefit of the integration of SPB and TAAb data and strongly support the further development of combinatorial proteomic approaches for detecting BC.


Assuntos
Autoanticorpos/genética , Autoanticorpos/metabolismo , Biomarcadores Tumorais/sangue , Neoplasias da Mama/diagnóstico , Proteômica/normas , Área Sob a Curva , Neoplasias da Mama/sangue , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Análise Multivariada , Curva ROC , Sensibilidade e Especificidade
17.
Med Phys ; 42(11): 6520-8, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26520742

RESUMO

PURPOSE: To identify a new clinical marker based on quantitative kinetic image features analysis and assess its feasibility to predict tumor response to neoadjuvant chemotherapy. METHODS: The authors assembled a dataset involving breast MR images acquired from 68 cancer patients before undergoing neoadjuvant chemotherapy. Among them, 25 patients had complete response (CR) and 43 had partial and nonresponse (NR) to chemotherapy based on the response evaluation criteria in solid tumors. The authors developed a computer-aided detection scheme to segment breast areas and tumors depicted on the breast MR images and computed a total of 39 kinetic image features from both tumor and background parenchymal enhancement regions. The authors then applied and tested two approaches to classify between CR and NR cases. The first one analyzed each individual feature and applied a simple feature fusion method that combines classification results from multiple features. The second approach tested an attribute selected classifier that integrates an artificial neural network (ANN) with a wrapper subset evaluator, which was optimized using a leave-one-case-out validation method. RESULTS: In the pool of 39 features, 10 yielded relatively higher classification performance with the areas under receiver operating characteristic curves (AUCs) ranging from 0.61 to 0.78 to classify between CR and NR cases. Using a feature fusion method, the maximum AUC=0.85±0.05. Using the ANN-based classifier, AUC value significantly increased to 0.96±0.03 (p<0.01). CONCLUSIONS: This study demonstrated that quantitative analysis of kinetic image features computed from breast MR images acquired prechemotherapy has potential to generate a useful clinical marker in predicting tumor response to chemotherapy.


Assuntos
Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Monitoramento de Medicamentos/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Algoritmos , Antineoplásicos/administração & dosagem , Feminino , Humanos , Aumento da Imagem/métodos , Aprendizado de Máquina , Pessoa de Meia-Idade , Redes Neurais de Computação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
18.
Oncotarget ; 6(16): 14545-55, 2015 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-26036630

RESUMO

The hypothesis to use microRNAs (miRNAs) circulating in the blood as cancer biomarkers was formulated some years ago based on promising initial results. After some exciting discoveries, however, it became evident that the accurate quantification of cell-free miRNAs was more challenging than expected. Difficulties were linked to the strong impact that many, if not all, pre- and post- analytical variables have on the final results. In this study, we used currently available high-throughput technologies to identify miRNAs present in plasma and serum of patients with breast, colorectal, lung, thyroid and melanoma tumors, and healthy controls. Then, we assessed the absolute level of nine different miRNAs (miR-320a, miR-21-5p, miR-378a-3p, miR-181a-5p, miR-3156-5p, miR-2110, miR-125a-5p, miR-425-5p, miR-766-3p) in 207 samples from healthy controls and cancer patients using droplet digital PCR (ddPCR) technology. We identified miRNAs specifically modulated in one or more cancer types, according to tissue source. The significant reduction of miR-181a-5p levels in breast cancer patients serum was further validated using two independent cohorts, one from Italy (n = 70) and one from US (n = 90), with AUC 0.66 and 0.73 respectively. This study finally powers the use of cell-free miRNAs as cancer biomarkers and propose miR-181a-5p as a diagnostic breast cancer biomarker.


Assuntos
Biomarcadores Tumorais/genética , Neoplasias da Mama/genética , MicroRNAs/genética , Estudos de Coortes , Feminino , Humanos
19.
Am J Surg ; 187(3): 349-62, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15006563

RESUMO

The potential for reducing the risk of breast cancer through selective estrogen receptor modulators, aromatase inhibitors, and surgery has generated interest in the use of quantitative models of risk assessment. With the addition of ductal lavage cytology to traditional epidemiologic risk factors, a discovery of cellular atypia can result in refinement of assigned risk values, while simultaneously optimizing patient selection for selective estrogen receptor modulators utilization. In view of increasing complexity in this arena, a Risk Assessment Working Group was formed to outline management strategies for the patient at an elevated risk for the development of breast cancer. No longer a statistical exercise, quantitative risk assessment is part of basic breast care and comprehensive management includes a discussion of the following: ductal lavage for improved risk stratification, multiple options for risk reduction, and high risk surveillance strategies that might incorporate investigational imaging protocols.


Assuntos
Neoplasias da Mama/epidemiologia , Neoplasias da Mama/terapia , Adulto , Distribuição por Idade , Idoso , Antineoplásicos Hormonais/uso terapêutico , Biópsia por Agulha , Neoplasias da Mama/patologia , Quimioterapia Adjuvante , Terapia Combinada , Feminino , Humanos , Imuno-Histoquímica , Incidência , Mastectomia/métodos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Prognóstico , Radioterapia Adjuvante , Medição de Risco , Análise de Sobrevida , Resultado do Tratamento , Estados Unidos/epidemiologia
20.
J Okla State Med Assoc ; 96(7): 299-307, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12955974

RESUMO

The barriers to magnetic resonance imaging (MRI) in the staging and diagnosis of breast cancer are being resolved through merging technologies and the new ability to perform MRI-guided biopsies. Detailed spatial resolution and excellent sensitivity are the strengths of this modality, whereas specificity is the primary challenge, requiring a strong commitment by the interested radiologist. While the original indication for breast MRI was in the evaluation of implant integrity, this modality is now recommended for: mapping tumor extent in newly diagnosed breast cancer patients, diagnosing breast cancer when conventional imaging is complex and indeterminate, and possibly for screening high-risk patients who have dense mammograms. A breast-dedicated magnetic resonance unit offers several advantages, including the first commercially available biopsy device. RODEOtm software (ROtating Delivery of Excitation Off-resonance) is an anticipated upgrade to this breast-dedicated unit, offering such a high degree of sensitivity and resolution that improved detection of Ductal Carcinoma In Situ will be possible.


Assuntos
Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética , Neoplasias da Mama/cirurgia , Carcinoma Intraductal não Infiltrante/diagnóstico , Feminino , Humanos , Mamografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA