J Water Health ; 20(4): 702-711, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35482386

RESUMO

This study examined 184 legionellosis outbreaks in the United States reported to the Centers for Disease Control and Prevention's Waterborne Disease and Outbreak Surveillance System, from 2001 to 2017. Drinking water characteristics examined include source water type, disinfectant type, exposure setting, geographical distribution by U.S. Census Divisions, and the public water system size (population served). This study found that most of the reported drinking water-associated legionellosis outbreaks occurred in eastern United States, including 35% in the South Atlantic, 32% in the Middle Atlantic, and 16% in the East North Central Census Divisions were linked with building water systems in healthcare and hotel settings; and were associated with buildings receiving drinking water from public water systems serving >10,000 people. Targeted evaluations and interventions may be useful to further determine the combination of factors, such as disinfectant residual type and drinking water system size that may lead to legionellosis outbreaks.


Assuntos
Desinfetantes , Água Potável , Legionelose , Surtos de Doenças , Humanos , Legionelose/epidemiologia , Estados Unidos/epidemiologia , Microbiologia da Água