Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Magn Reson Imaging ; 44(1): 72-80, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26800280

RESUMO

PURPOSE: To determine whether quantitation of T2* is sufficiently repeatable and sensitive to detect clinically relevant oxygenation levels in head and neck squamous cell carcinoma (HNSCC) at 3T. MATERIALS AND METHODS: Ten patients with newly diagnosed locally advanced HNSCC underwent two magnetic resonance imaging (MRI) scans between 24 and 168 hours apart prior to chemoradiotherapy treatment. A multiple gradient echo sequence was used to calculate T2* maps. A quadratic function was used to model the blood transverse relaxation rate as a function of blood oxygenation. A set of published coefficients measured at 3T were incorporated to account for tissue hematocrit levels and used to plot the dependence of fractional blood oxygenation (Y) on T2* values, together with the corresponding repeatability range. Repeatability of T2* using Bland-Altman analysis, and calculation of limits of agreement (LoA), was used to assess the sensitivity, defined as the minimum difference in fractional blood oxygenation that can be confidently detected. RESULTS: T2* LoA for 22 outlined tumor volumes were 13%. The T2* dependence of fractional blood oxygenation increases monotonically, resulting in increasing sensitivity of the method with increasing blood oxygenation. For fractional blood oxygenation values above 0.11, changes in T2* were sufficient to detect differences in blood oxygenation greater than 10% (Δ T2* > LoA for ΔY > 0.1). CONCLUSION: Quantitation of T2* at 3T can detect clinically relevant changes in tumor oxygenation within a wide range of blood volumes and oxygen tensions, including levels reported in HNSCC. J. Magn. Reson. Imaging 2016;44:72-80.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/metabolismo , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/metabolismo , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Oxigênio/metabolismo , Biomarcadores Tumorais/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carcinoma de Células Escamosas de Cabeça e Pescoço
2.
Phys Med Biol ; 69(12)2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38648786

RESUMO

Objective.Image quality in whole-body MRI (WB-MRI) may be degraded by faulty radiofrequency (RF) coil elements or mispositioning of the coil arrays. Phantom-based quality control (QC) is used to identify broken RF coil elements but the frequency of these acquisitions is limited by scanner and staff availability. This work aimed to develop a scan-specific QC acquisition and processing pipeline to detect broken RF coil elements, which is sufficiently rapid to be added to the clinical WB-MRI protocol. The purpose of this is to improve the quality of WB-MRI by reducing the number of patient examinations conducted with suboptimal equipment.Approach.A rapid acquisition (14 s additional acquisition time per imaging station) was developed that identifies broken RF coil elements by acquiring images from each individual coil element and using the integral body coil. This acquisition was added to one centre's clinical WB-MRI protocol for one year (892 examinations) to evaluate the effect of this scan-specific QC. To demonstrate applicability in multi-centre imaging trials, the technique was also implemented on scanners from three manufacturers.Main results. Over the course of the study RF coil elements were flagged as potentially broken on five occasions, with the faults confirmed in four of those cases. The method had a precision of 80% and a recall of 100% for detecting faulty RF coil elements. The coil array positioning measurements were consistent across scanners and have been used to define the expected variation in signal.Significance. The technique demonstrated here can identify faulty RF coil elements and positioning errors and is a practical addition to the clinical WB-MRI protocol. This approach was fully implemented on systems from two manufacturers and partially implemented on a third. It has potential to reduce the number of clinical examinations conducted with suboptimal hardware and improve image quality across multi-centre studies.


Assuntos
Imageamento por Ressonância Magnética , Controle de Qualidade , Imagem Corporal Total , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/normas , Humanos , Imagem Corporal Total/instrumentação , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos , Ondas de Rádio
3.
Br J Radiol ; 94(1126): 20210310, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34545764

RESUMO

OBJECTIVES: Myxoid liposarcomas (MLS) show enhanced response to radiotherapy due to their distinctive vascular pattern and therefore could be effectively treated with lower radiation doses. This is a descriptive study to explore the use of functional MRI to identify response in a uniform cohort of MLS patients treated with reduced dose radiotherapy. METHODS: 10 patients with MLS were imaged pre-, during, and post-radiotherapy receiving reduced dose radiotherapy and the response to treatment was histopathologically assessed post-radiotherapy. Apparent diffusion coefficient (ADC), T2* relaxation time, volume transfer constant (Ktrans), initial area under the gadolinium curve over 60 s (IAUGC60) and (Gd) were estimated for a central tumour volume. RESULTS: All parameters showed large inter- and intrasubject variabilities. Pre-treatment (Gd), IAUGC60 and Ktrans were significantly different between responders and non-responders. Post-radiotherapy reductions from baseline were demonstrated for T2*, (Gd), IAUGC60 and Ktrans for responders. No statistically significant ADC differences were demonstrated between the two response groups. Significantly greater early tumour volume reductions were observed for responders. CONCLUSIONS: MLS are heterogenous lesions, characterised by a slow gradual contrast-agent uptake. Pre-treatment vascular parameters, early changes to tumour volume, vascular parameters and T2* have potential in identifying response to treatment. The delayed (Gd) is a suitable descriptive parameter, relying simply on T1 measurements. Volume changes precede changes in MLS functionality and could be used to identify early response. ADVANCES IN KNOWLEDGE: MLS are are characterised by slow gradual contrast-agent uptake. Measurement of the delayed contrast-agent uptake (Gd) is simple to implement and able to discriminate response.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Lipossarcoma Mixoide/diagnóstico por imagem , Lipossarcoma Mixoide/radioterapia , Adulto , Meios de Contraste , Feminino , Humanos , Lipossarcoma Mixoide/patologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Dosagem Radioterapêutica , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Carga Tumoral
4.
Clin Cancer Res ; 23(15): 4233-4241, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28314789

RESUMO

Purpose: To evaluate intrinsic susceptibility (IS) MRI for the identification of cycling hypoxia, and the assessment of its extent and spatial distribution, in head and neck squamous cell carcinoma (HNSCC) xenografts and patients.Experimental Design: Quantitation of the transverse relaxation rate, R2*, which is sensitive to paramagnetic deoxyhemoglobin, using serial IS-MRI acquisitions, was used to monitor temporal oscillations in levels of paramagnetic deoxyhemoglobin in human CALR xenografts and patients with HNSCC at 3T. Autocovariance and power spectrum analysis of variations in R2* was performed for each imaged voxel, to assess statistical significance and frequencies of cycling changes in tumor blood oxygenation. Pathologic correlates with tumor perfusion (Hoechst 33342), hypoxia (pimonidazole), and vascular density (CD31) were sought in the xenografts, and dynamic contrast-enhanced (DCE) MRI was used to assess patient tumor vascularization. The prevalence of fluctuations within patient tumors, DCE parameters, and treatment outcome were reported.Results: Spontaneous R2* fluctuations with a median periodicity of 15 minutes were detected in both xenografts and patient tumors. Spatially, these fluctuations were predominantly associated with regions of heterogeneous perfusion and hypoxia in the CALR xenografts. In patients, R2* fluctuations spatially correlated with regions of lymph nodes with low Ktrans values, typically in the vicinity of necrotic cores.Conclusions: IS-MRI can be used to monitor variations in levels of paramagnetic deoxyhemoglobin, associated with cycling hypoxia. The presence of such fluctuations may be linked with impaired tumor vasculature, the presence of which may impact treatment outcome. Clin Cancer Res; 23(15); 4233-41. ©2017 AACR.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Linfonodos/diagnóstico por imagem , Imageamento por Ressonância Magnética , Neovascularização Patológica/diagnóstico por imagem , Animais , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/patologia , Hipóxia Celular/genética , Linhagem Celular Tumoral , Meios de Contraste/uso terapêutico , Feminino , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Linfonodos/patologia , Masculino , Camundongos , Neovascularização Patológica/tratamento farmacológico , Neovascularização Patológica/patologia , Nitroimidazóis/administração & dosagem , Tolerância a Radiação/efeitos dos fármacos , Carcinoma de Células Escamosas de Cabeça e Pescoço , Resultado do Tratamento , Ensaios Antitumorais Modelo de Xenoenxerto
5.
Res Q Exerc Sport ; 85(2): 245-50, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25098020

RESUMO

PURPOSE: The purpose was to develop a new method for assessing the potential bone-loading intensities of different locomotion activities by using accelerometers. METHOD: Thirty participants (women, N = 19; men, N = 11) with an average age of 40 years (SD = 18 years), performed 8 activities (3 self-selected speeds of walking, 3 self-selected speeds of running, and ascending and descending stairs) in the workplace or at home while wearing an accelerometer. The loading intensity for each activity was calculated from measured acceleration by a new method that considers both loading magnitude and frequency. A 1-way repeated-measures analysis of variance was employed to examine whether type of activity had any significant influence on the loading intensity. RESULTS: The 8 activities showed different loading intensities (p < .001, partial eta2 = .87). Running had higher loading intensity than walking and ascending or descending stairs (p < .05, Cohen's d = 1.79). The higher the speed of walking or running, the higher the loading intensity (p < .05, Cohen's d = 1.15). The increase of loading intensity in different activities was induced by both the increase of loading magnitude and the shift of loading frequency. CONCLUSIONS: This study developed a new method to measure loading intensity of physical activity on bone by using an accelerometer. This method can provide new insight for the assessment of exercise intensity in relation to bone health.


Assuntos
Acelerometria , Ossos da Perna/fisiologia , Corrida/fisiologia , Caminhada/fisiologia , Adulto , Feminino , Humanos , Masculino , Suporte de Carga/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA