Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Sensors (Basel) ; 24(18)2024 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-39338851

RESUMO

The leaf area index (LAI) is a key indicator of vegetation canopy structure and growth status, crucial for global ecological environment research. The Moderate Resolution Spectral Imager-II (MERSI-II) aboard Fengyun-3D (FY-3D) covers the globe twice daily, providing a reliable data source for large-scale and high-frequency LAI estimation. VI-based LAI estimation is effective, but species and growth status impacts on the sensitivity of the VI-LAI relationship are rarely considered, especially for MERSI-II. This study analyzed the VI-LAI relationship for eight biomes in China with contrasting leaf structures and canopy architectures. The LAI was estimated by adaptively combining multiple VIs and validated using MODIS, GLASS, and ground measurements. Results show that (1) species and growth stages significantly affect VI-LAI sensitivity. For example, the EVI is optimal for broadleaf crops in winter, while the RDVI is best for evergreen needleleaf forests in summer. (2) Combining vegetation indices can significantly optimize sensitivity. The accuracy of multi-VI-based LAI retrieval is notably higher than using a single VI for the entire year. (3) MERSI-II shows good spatial-temporal consistency with MODIS and GLASS and is more sensitive to vegetation growth fluctuation. Direct validation with ground-truth data also demonstrates that the uncertainty of retrievals is acceptable (R2 = 0.808, RMSE = 0.642).


Assuntos
Folhas de Planta , Folhas de Planta/crescimento & desenvolvimento , China , Ecossistema , Florestas , Imagens de Satélites/métodos , Estações do Ano
2.
Opt Express ; 30(7): 11986-12007, 2022 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-35473129

RESUMO

A compact polarization Raman lidar has been designed and constructed for using it for atmospheric correction measurements during satellite optical sensor calibration in areas with high altitude and extremely low aerosol loading. The parameters of this lidar, such as laser wavelength, telescope diameter and interference filter bandwidth, were simulated and optimized for the best observation performance. The instrument has low weight, is small in size, and requires air cooling instead of commonly used water-cooling of the laser. Thus, the instrument is suitable for autonomous operation in remote sites. The lidar prototype was installed in Lijiang (26°43' N, 100°01' E), China, a potential observation site for calibrations of optical sensors of satellites. This observation site has been shown to be an appropriate place for remote sensing and satellite calibration activities with low aerosol loading, thin air and a comparably high proportion of cloud-free days. A field campaign carried out between November 2019 and April 2020 allowed for thoroughly testing the instruments. The results of test observations show that complete overlap between emitted laser beam and field-of-view of the receiver unit is achieved at relatively low heights above ground. The measurement accuracy is comparably high. Thus, this instrument is suitable for operating in areas with relatively clean atmospheric conditions.

3.
J Environ Sci Health B ; 56(6): 587-593, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34102954

RESUMO

The dissipation and residue of validamycin A in grapes were investigated under field conditions. An ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for the determination of validamycin A in grapes was established and validated. Methanol and water (90/10, v/v) were used for validamycin A extraction and purification used MCX solid-phase extraction cartridges. The average recoveries of validamycin A in grapes at 0.01, 0.50, and 5.0 mg/kg levels were between 83.8 and 91.4%, with relative standard deviations of 2.3-3.0%. The half-lives of validamycin A in grape were 4.4-6.1 days. The terminal residues in grapes over a range of harvest times (7, 14, and 21 days) were no more than 0.73 mg/kg. According to Chinese consumption data, the risk quotient (RQ) of validamycin A was 3.22%, demonstrating a low risk to consumers. The current study may offer guidance for validamycin A use and could aid the government in determining the maximum residue level (MRL) values for validamycin A in grapes.


Assuntos
Frutas/química , Fungicidas Industriais/análise , Inositol/análogos & derivados , Resíduos de Praguicidas/análise , Vitis/química , Cromatografia Líquida de Alta Pressão , Exposição Dietética/análise , Contaminação de Alimentos/análise , Humanos , Inositol/análise , Medição de Risco , Extração em Fase Sólida , Espectrometria de Massas em Tandem
4.
Sensors (Basel) ; 20(17)2020 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-32825258

RESUMO

Limited by the on-orbital calibration capability, scaling the measured radiance in accuracy and stability is challenging for the Earth observation satellites in the reflective solar bands (RSBs). Although the lunar calibration is a well-developed technique in the RSBs, limited work has been done for Chinese Earth observation satellites. To improve the on-orbital calibration performance, the advanced MEdium Resolution Spectral Imager (MERSI II), which is the primary payload of the fourth satellite of the Fengyun 3 Series (FY-3D), expands the space view angle of the imager in order to capture better lunar images. In this study, we propose an absolute radiometric calibration method based on the FY-3D/MERSI lunar observation data. A lunar irradiance model named ROLO/GIRO has been used together with the necessary data procedures, including dark current count estimation, single pixel irradiance calculation, and full disk lunar irradiance calculation. The calibration coefficients obtained by the lunar calibration are compared with the pre-launch laboratory calibration. The results show that the deviations between the two calibration procedures are in a reasonable range in general. However, a relatively high non-linear response was found in the low energy incidence for some detectors, which leads to the large deviation in the corresponding bands. This study explored an ideal and independent method to validate MERSI on-orbit radiometric performance. The lunar calibration practiced for MERSI also gave a valuable example that can be recommended to the other Chinese Earth observation satellites.

5.
Appl Opt ; 58(20): 5506-5515, 2019 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-31504021

RESUMO

Mirror jitters around a bias tilt angle can make noise performance degradation for a space-borne Michelson interferometer. A numerical model simulates the Hyperspectral Infrared Atmospheric Sounder (HIRAS) spectra affected by the mirror jitters. According to the simulation, mirror jitters mainly generate spectrally correlated noise, which can be estimated by subtracting the random noise component from the total noise. The random noise is estimated through a principal component analysis (PCA) technique. Applying the PCA noise estimator as a diagnostic tool to monitor the noise level in the process of bias tilt angle tuning, optimized HIRAS noise performance is achieved with the correlated noise component minimized.

6.
Guang Pu Xue Yu Guang Pu Fen Xi ; 37(2): 394-402, 2017 Feb.
Artigo em Zh | MEDLINE | ID: mdl-30264968

RESUMO

The energy received through remote sensing sensors contains the amount of reflected solar energy and emitted energy of objects in middle-wave infrared (MWIR, 3~5 µm). Usually, the reflected solar energy is weak in MWIR spectrum. In some certain situations like sun glint area in sea surface, however, the energy is relatively significant and less sensitive to atmospheric effects. Meanwhile, for the satellite sensor which equipped with onboard calibration system, its onboard radiation performance of MWIR(using blackbody calibration)is quite stable. Therefore, the MWIR reflectance in sea surface glint area can be considered as a reference for cross-calibration between the solar reflected bands. Based on this idea, this paper constructed an improved non-linear split window model that is suitable for VIIRS (visible infrared imaging radiometer) MWIR band and used this model to calculate the MWIR reflectance of sun glint area in southern Indian Ocean. This model made statistics, getting the relationship between the reflectance of VIIRS M12 and M13 bands at first, and then used the non-linear split window algorithm to calculate the actual sea surface reflectance. The uncertainty of the simulation model was 0.83%. On this basis, this paper calculated sea surface reflectance of selected sample regions based on the data of VIIRS M12 band (center wavelength: 3.697 µm) in sun glint areas. And then verified the reflectance accuracy by two methods, getting the two accuracies were about 0.239% and 0.23%, respectively. It proves that the calculation model in this paper can greatly improve the accuracy compared to the situation when the sea surface reflectance is between M12 and M13 which are assumed to be equal (accuracy of 2.48% and 1.03%, respectively). It also indicated that the model is feasible and effective to calculate the reflectance in sea surface glint area with VIIRS M12 MWIR band, and the accuracy can meet the requirements of MWIR sea surface reflectance as a calibration reference among bands.

7.
Appl Opt ; 55(31): 8770-8778, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27828274

RESUMO

The lunar spectrum has been used in radiometric calibration and sensor stability monitoring for spaceborne optical sensors. A ground-based large-aperture static image spectrometer (LASIS) can be used to acquire the lunar spectral image for lunar radiance model improvement when the moon orbits over its viewing field. The lunar orbiting behavior is not consistent with the desired scanning speed and direction of LASIS. To correctly extract interferograms from the obtained data, a translation correction method based on image correlation is proposed. This method registers the frames to a reference frame to reduce accumulative errors. Furthermore, we propose a circle-matching-based approach to achieve even higher accuracy during observation of the full moon. To demonstrate the effectiveness of our approaches, experiments are run on true lunar observation data. The results show that the proposed approaches outperform the state-of-the-art methods.

8.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(8): 2639-45, 2016 Aug.
Artigo em Zh | MEDLINE | ID: mdl-30074721

RESUMO

A radiometric calibration method is described in this paper by using the deep convective clouds (Deep Convective Cloud, DCC) target for FY-2 visible channel. The deep convective cloud can be used as the radiometric calibration transfer object. The on-operational FY-2 radiometric calibration bias and the long-term degradation trend are evaluated according to the AQUA/MODIS instrument as the baseline of radiometric reference and DCC. The results show that: (1) There are different degrees of degradation for FY-2D, FY-2E and FY-2F, among which FY-2D has the biggest degradation due to the longest period. The annual rates of degradation for FY-2D and FY-2E are quite similar, 1.67% and 1.69% respectively, whereas the rate for FY-2F is lower with 0.81%; (2) During the period of satellite eclipse, the instruments are not stable and this phenomenon could be detected by the DCC method;(3) There are bias in the the operational radiometric calibration between FY-2 and AQUA/MODIS, which is treated as the the radiometric reference usually. The radiometric calibration method based on DCC could work well in the radiometric calibration for FY-2. The results will help us to understand the degradation of instrument and for quantitative application usage.

9.
Molecules ; 20(1): 1161-75, 2015 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-25587790

RESUMO

Glyphosate formulations that are used as a broad-spectrum systemic herbicide have been widely applied in agriculture, causing increasing concerns about residues in soils. In this study, the degradation dynamics of glyphosate in different types of citrus orchard soils in China were evaluated under field conditions. Glyphosate soluble powder and aqueous solution were applied at 3000 and 5040 g active ingredient/hm2, respectively, in citrus orchard soils, and periodically drawn soil samples were analyzed by high performance liquid chromatography. The results showed that the amount of glyphosate and its degradation product aminomethylphosphonic acid (AMPA) in soils was reduced with the increase of time after application of glyphosate formulations. Indeed, the amount of glyphosate in red soil from Hunan and Zhejiang Province, and clay soil from Guangxi Province varied from 0.13 to 0.91 µg/g at 42 days after application of aqueous solution. Furthermore, the amount of glyphosate in medium loam from Zhejiang and Guangdong Province, and brown loam from Guizhou Province varied from less than 0.10 to 0.14 µg/g, while the amount of AMPA varied from less than 0.10 to 0.99 µg/g at 42 days after application of soluble powder. Overall, these findings demonstrated that the degradation dynamics of glyphosate aqueous solution and soluble powder as well as AMPA depend on the physicochemical properties of the applied soils, in particular soil pH, which should be carefully considered in the application of glyphosate herbicide.


Assuntos
Citrus , Produtos Agrícolas , Glicina/análogos & derivados , Poluentes do Solo/química , China , Cromatografia Líquida de Alta Pressão , Glicina/química , Cinética , Espectrometria de Fluorescência , Glifosato
10.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(12): 3429-34, 2014 Dec.
Artigo em Zh | MEDLINE | ID: mdl-25881453

RESUMO

Accurate satellite radiance measurements are significant for data assimilations and quantitative retrieval applications. In the present paper, radiometric calibration accuracy of FungYun-3A (FY-3A) Medium Resolution Spectral Imager (MERSI) thermal infrared (TIR) channel was evaluated based on simultaneous nadir observation (SNO) intercalibration method. Hyperspectral and high-quality measurements of METOP-A/IASI were used as reference. Assessment uncertainty from intercalibration method was also investigated by examining the relation between BT bias against four main collocation factors, i. e. observation time difference, view geometric difference related to zenith angles and azimuth angles, and scene spatial homogeneity. It was indicated that the BT bias is evenly distributed across the collocation variables with no significant linear relationship in MERSI IR channel. Among the four collocation factors, the scene spatial homogeneity may be the most important factor with the uncertainty less than 2% of BT bias. Statistical analysis of monitoring biases during one and a half years indicates that the brightness temperature measured by MERSI is much warmer than that of IASI. The annual mean bias (MERSI-IASI) in 2012 is (3.18±0.34) K. Monthly averaged BT biases show a little seasonal variation character, and fluctuation range is less than 0.8 K. To further verify the reliability, our evaluation result was also compared with the synchronous experiment results at Dunhuang and Qinghai Lake sites, which showed excellent agreement. Preliminary analysis indicates that there are two reasons leading to the warm bias. One is the overestimation of blackbody emissivity, and the other is probably the incorrect spectral respond function which has shifted to window spectral. Considering the variation character of BT biases, SRF error seems to be the dominant factor.

11.
J AOAC Int ; 96(6): 1448-52, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24645528

RESUMO

A method was developed for the determination of cyantraniliprole (HGW86) and its metabolite J9Z38 in watermelon and soil by ultra-performance LC (UPLC)/MS/MS. Target compounds were extracted by acetonitrile-water, cleaned up on a silica gel column, and determined by UPLC/MS/MS. Average recoveries of cyantraniliprole and J9Z38 in watermelon and soil at three levels (0.01, 0.1, and 0.5 mg/kg) ranged from 85.71 to 105.74%, with RSDs of 0.90-6.34%. The LOQs for cyantraniliprole and J9Z38 were determined to be 0.00021, 0.00015, 0.0010, and 0.00090 mg/kg in watermelon and soil samples, respectively. This method was used to determine the cyantraniliprole and J9Z38 residues in watermelon and soil samples for studies on their dissipation. The trial results showed that the half-lives of cyantraniliprole obtained after treatments were 1.1 and 4.1 days in watermelon and soil in Zhejiang, and 2.7 and 2.6 days in watermelon and soil in Hunan, respectively. The average levels of cyantraniliprole and J9Z38 residues in watermelon and soil were all < 0.01 mg/kg within the 14-day interval after treatment.


Assuntos
Citrullus/química , Análise de Alimentos/métodos , Resíduos de Praguicidas/análise , Pirazóis/análise , Poluentes do Solo/análise , Solo/química , ortoaminobenzoatos/análise , Calibragem , Técnicas de Química Analítica , Cromatografia Líquida de Alta Pressão/métodos , Monitoramento Ambiental/métodos , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Fatores de Tempo
12.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(7): 1869-77, 2012 Jul.
Artigo em Zh | MEDLINE | ID: mdl-23016343

RESUMO

MERSI is the keystone payload of FengYun-3 and there have been two sensors operating on-orbit since 2008. The on-orbit response changes obviously at reflective solar bands (RSBs) and must be effectively monitored and corrected. However MERSI can not realize the RSBs onboard absolute radiometric calibration. This paper presents a new vicarious calibration (VC) method for RSBs based on in-situ BRDF model, and vector radiometric transfer model 6SV with gaseous absorption correction using MOTRAN. The results of synchronous VC experiments in 4 years show that the calibration uncertainties are within 5% except for band at the center of water vapor absorption, and 3% for most bands. Aqua MODIS was taken as the radiometric reference to evaluate the accuracy of this VC method. By comparison of the simulated radiation at top of atmosphere (TOA) with MODIS measurement, it was revealed that the average relative differences are within 3% for window bands with wavelengths less than 1 microm, and 5% for bands with wavelengths larger than 1 microm (except for band 7 at 2.1 microm). Besides, the synchronous nadir observation cross analysis shows the excellent agreement between re-calibrated MERSI TOA apparent reflectance and MODIS measurements. Based on the multi-year site calibration results, it was found that the calibration coefficients could be fitted with two-order polynomials, thus the daily calibration updates could be realized and the response variation between two calibration experiments could be corrected timely; there are large response changes at bands with wavelengths less than 0.6 microm, the degradation rate of the first year at band 8 (0.41 microm) is about 14%; the on-orbit response degradation is maximum at the beginning, the degradation rates slow down after one year in operation, and after two years the responses even increase at some band with wavelengths larger than 0.6 microm.

13.
Environ Sci Pollut Res Int ; 29(34): 51758-51767, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35253103

RESUMO

Fritillaria (Beimu in Chinese) is a well-known traditional Chinese medicinal herbal and valuable health food, which has attracted more and more attention. In this study, an efficient method was developed to determine pyraclostrobin, fluxapyroxad, difenoconazole, and azoxystrobin in plants, fresh Fritillaria, dry Fritillaria, and soil via liquid chromatography-tandem mass spectrometry. The average recoveries of the method were 78.9-109.7% with relative standard deviations of 0.94-11.1%. The dissipation half-lives of the four fungicides were 4.4-7.7 days in the Fritillaria plant and 11.6-18.2 days in the soil. The terminal residues of four fungicides were 0.033-0.13 mg/kg in fresh Fritillaria, 0.096-0.42 mg/kg in dry Fritillaria, and 0.12-0.74 mg/kg in soil. In the risk assessment of dietary exposure, all the chronic hazard quotient and acute hazard quotient index values were far below 100%, which were both acceptable to consumers. Accordingly, 7 days was recommended as the pre-harvest interval for the four fungicides in Fritillaria. This work could guide the safe use of these fungicides in Fritillaria and also give a reference for the Chinese government to establish the maximum residue limits (MRLs).


Assuntos
Fritillaria , Fungicidas Industriais , Resíduos de Praguicidas , Amidas , China , Exposição Dietética/análise , Dioxolanos , Ecossistema , Fungicidas Industriais/análise , Resíduos de Praguicidas/análise , Pirimidinas , Medição de Risco , Solo/química , Estrobilurinas/análise , Espectrometria de Massas em Tandem/métodos , Triazóis
14.
Light Sci Appl ; 11(1): 329, 2022 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-36414615

RESUMO

The solar X-ray and Extreme Ultraviolet Imager (X-EUVI), developed by the Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences (CIOMP), is the first space-based solar X-ray and Extreme ultraviolet (EUV) imager of China loaded on the Fengyun-3E (FY-3E) satellite supported by the China Meteorological Administration (CMA) for solar observation. Since started work on July 11, 2021, X-EUVI has obtained many solar images. The instrument employs an innovative dual-band design to monitor a much larger temperature range on the Sun, which covers 0.6-8.0 nm in the X-ray region with six channels and 19.5 nm in the EUV region. X-EUVI has a field of view of 42', an angular resolution of 2.5″ per pixel in the EUV band and an angular resolution of 4.1″ per pixel in the X-ray band. The instrument also includes an X-ray and EUV irradiance sensor (X-EUVS) with the same bands as its imaging optics, which measures the solar irradiance and regularly calibrates the solar images. The radiometric calibration of X-EUVS on the ground has been completed, with a calibration accuracy of 12%. X-EUVI is loaded on the FY-3E satellite and rotates relative to the Sun at a uniform rate. Flat-field calibration is conducted by utilizing successive rotation solar images. The agreement between preliminarily processed X-EUVI images and SDO/AIA and Hinode/XRT images indicates that X-EUVI and the data processing algorithm operate properly and that the data from X-EUVI can be applied to the space weather forecast system of CMA and scientific investigations on solar activity.

15.
Environ Pollut ; 286: 117531, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34126519

RESUMO

Guadipyr, which combines neonicotinoid and semicarbazone functional groups in one molecule, exhibits good activity on several pests and high acute and chronic toxicity to silkworms (Bombyx mori). In this report, the effects of low-dose guadipyr on the midgut microbiota and immune system of silkworms were studied. Results showed that the structure and richness of the midgut microbiota of silkworms were altered after being treated with 5.25 mg/L (1/10 of LC50) of guadipyr. The abundance of Pseudomonas was evidently increased, whereas Curvibacter was substantially reduced, which might be related to the growth and immunity of silkworms. The expression of key genes in the Toll, IMD, and JAK/STAT pathways, which ultimately led to the downregulation of antimicrobial peptide genes (AMPs), such as CecA, Defensin1, Leb, and glv2, was reduced upon guadipyr exposure. Simultaneously, the suppression of steroid hormone 20-hydroxyecdysone receptor and response genes, such as BR-C Z4, was detected in the exposed groups. The decreased expression of these immune regulatory pathway-related and 20-hydroxyecdysone signal pathway-related genes indicated that the immune system of silkworms was affected by low-dose guadipyr. Our results revealed the negative effects of guadipyr on silkworms and highlighted the unneglectable toxicity of low-dose guadipyr to this economic insect. Given the risk, it is necessary to control the application of guadipyr in or around the mulberry fields.


Assuntos
Bombyx , Doenças do Sistema Imunitário , Inseticidas , Microbiota , Animais , Disbiose , Guanidinas , Proteínas de Insetos , Inseticidas/toxicidade , Larva
16.
Environ Sci Pollut Res Int ; 27(13): 15165-15173, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32067175

RESUMO

This study aimed to develop a reliable method for the simultaneous analysis of triflumizole (TRIF) and its primary metabolite FM-6-1 (N-4-chloro-2-trifluoromethylphenyl-2-propoxy-acetamidine) in the soil and treated strawberries using solid phase extraction (SPE) coupled with gas chromatography-tandem mass spectrometry (GC-MS/MS). Using this method, TRIF and FM-6-1 degradation in strawberries and the soil under greenhouse conditions were investigated. The field trials showed that t1/2 of TRIF and total residues (the sum of TRIF and FM-6-1) were 1.6-2.2 days and 2.4-2.9 days in strawberry and 4.3-6.1 days and 5.5-6.9 days in soil, respectively. Terminal total residues were ≤ 0.39 mg/kg in strawberry and ≤ 0.42 mg/kg in soil from 5 to 10 days of harvest. The risk quotient (RQ) of TRIF was below 1.89%, showing that the dietary risk of TRIF in strawberry was low. These findings provide guidance for the use of TRIF on crops and provide reference to establish the maximum residue level (MRL) of TRIF in strawberry.


Assuntos
Fragaria , Resíduos de Praguicidas/análise , Poluentes do Solo/análise , Cromatografia Gasosa-Espectrometria de Massas , Meia-Vida , Imidazóis , Medição de Risco , Solo , Espectrometria de Massas em Tandem
17.
Guang Pu Xue Yu Guang Pu Fen Xi ; 29(5): 1213-7, 2009 May.
Artigo em Zh | MEDLINE | ID: mdl-19650456

RESUMO

Gobi surface emissivity spectrum of Dunhuang radiometric calibration site of China is one of the key factors to calibrate the thermal infrared remote sensors using land surface. Based on the iterative spectrally smooth temperature/emissivity separation (ISSTES)algorithm, Dunhuang Gobi surface emissivity spectrum was measured using BOMEM MR154 Fourier transform spectroradiometer and Infrared Golden Board. Emissivity spectrum data were obtained at different time and locations. These spectrum data were convolved with the channel response function of CE312 radiometer and compared with the channel emissivity measured by the same instrument. The results showed that the difference between these two kinds of channel emissivity was within 0.012 and exhibited a good consistency. With these measured emissivity spectra, all of the mainstream thermal infrared remote sensors can be calibrated using Dunhuang Gobi surface at radiometric calibration site of China.

18.
Guang Pu Xue Yu Guang Pu Fen Xi ; 29(5): 1153-9, 2009 May.
Artigo em Zh | MEDLINE | ID: mdl-19650442

RESUMO

Chinese MODIS onboard ShenZhou-3 spacecraft (SZ-3/CMODIS)is the experiment instrument of next generation environmental and meteorological satellites. CMODIS can obtain the data of 30 bands in visible and near infrared region from the earth-atmosphere system. But the quantitative application of these data is limited by radiometric calibration The present paper addresses a new concept of semi-synchronous measurements with satellite observation based on the traditional sites vicarious calibration It can meet the expected calibration requirement under the condition of no enough ground measurements. In addition to this, the reflectance of Dunhuang Calibration site is very smooth on the Vis-NIR spectral region A new cross-calibration was also conducted experimentally using the spectral interpolation of atmospheric correction reflectance from EOS/MODIS. The results of these two methods were compared and verified with each other and showed that they are effective and reliable. These new radiometric calibration methods provide good technique experiences for the next generation in-flight optical sensors.

19.
J Agric Food Chem ; 62(29): 7072-7, 2014 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-24945619

RESUMO

Dermal and respiratory exposure assessments and risk assessment for applicators were performed with 48% chlorpyrifos EC. The chlorpyrifos was applied with lever-operated knapsacks under three spraying environments, namely, average maize field heights of 62 cm (A1), 108 cm (A2), and 212 cm (A3). The whole body dosimetry technique was applied to collect dermal exposure samples including cotton protective garments, gloves, socks, and hats. A personal air monitor equipped with an XAD-2 resin was used for respiratory exposure assessment. Without personal protective equipment (PPE) the total potential dermal exposure (PDE) was 27.8, 90.6, and 462.1 mL h(-1) under A1, A2, and A3 spraying environments, respectively. In addition, with the change in the maize plant height, the major exposure parts on the applicators were also different. Under single-layer garment and glove protection circumstances, internal dermal exposure (IDE) was 3.37 mL h(-1) for A1, 4.28 mL h(-1) for A2, and 18.32 mL h(-1) for A3. Potential inhalation exposure (PIE) was detected in A3, but it was not detected in A1 and A2. For risk assessment, the margin of safety (MOS) was calculated from the PDE or IDE and PIE. The MOS values for the three spraying environments were <1 under no PPE and single-layer garment and glove protection circumstances, indicating high possibility of health risk. However, with double protective garments, the MOS values for A1 and A2 cases were all >1, but the MOS was <1 in the A3 case.


Assuntos
Clorpirifos/toxicidade , Produtos Agrícolas , Inseticidas/toxicidade , Exposição Ocupacional , Pele/efeitos dos fármacos , Zea mays , China , Humanos , Exposição por Inalação , Medição de Risco
20.
Chemosphere ; 93(1): 190-5, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23800585

RESUMO

A simple and reliable analytical method was developed to detect cyantraniliprole (HGW86) and its metabolite J9Z38 in rice straw, paddy water, brown rice, and paddy soil. The fate of cyantraniliprole and its metabolite J9Z38 in rice field ecosystem was also studied. The target compounds were extracted using acetonitrile, cleaned up on silicagel or strong anion exchange column, and analyzed by ultra-performance liquid chromatography-tandem mass spectrometry. The average recoveries of cyantraniliprole and J9Z38 in rice straw, paddy water, brown rice, and paddy soil ranged from 79.0% to 108.6%, with relative standard deviations of 1.1-10.6%. The limits of quantification of cyantraniliprole and J9Z38 were 18 and 39µgkg(-1) for rice straw, 2.8 and 5.0µgkg(-1) for paddy water, 4.3 and 6.3µgkg(-1) for brown rice, and 3.9 and 5.3µgkg(-1) for paddy soil. The trial results showed that the half-lives of cyantraniliprole were 3.2, 4.4, and 6.3d in rice straw and 4.9, 2.0, and 6.2d in paddy water in Zhejiang, Hunan, and Shandong, respectively. The respective final residues of cyantraniliprole and J9Z38 in brown rice were lower than 0.05 and 0.02mgkg(-1) after 14d of pre-harvest interval. The maximum residue limit of cyantraniliprole at 0.1mgkg(-1) and dosage of 100g a.i.hm(-2), which could be considered safe to human beings and animals, were recommended.


Assuntos
Ecossistema , Oryza/química , Resíduos de Praguicidas/análise , Resíduos de Praguicidas/metabolismo , Pirazóis/análise , Pirazóis/metabolismo , ortoaminobenzoatos/análise , ortoaminobenzoatos/metabolismo , Cinética , Controle de Pragas , Saúde Pública , Solo/química , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA