Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
J Magn Reson Imaging ; 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38553860

RESUMO

BACKGROUND: Extracellular volume (ECV) correlates with the degree of liver fibrosis. PURPOSE: To analyze the performance of liver MRI-based ECV evaluations with different blood pool measurements at different time points. STUDY TYPE: Prospective. SAMPLE: 73 consecutive patients (n = 31 females, mean age 56 years) with histopathology-proven liver fibrosis. FIELD STRENGTH/SEQUENCE: 3T acquisition within 90 days of biopsy, including shortened modified look-locker inversion recovery T1 mapping. ASSESSMENT: Polygonal regions of interest were manually drawn in the liver, aorta, vena cava, and in the main, left and right portal vein on four slices before and after Gd-DOTA administration at 5/10/15 minutes. ECV was calculated 1) on one single slice on portal bifurcation level, and 2) averaged over all four slices. STATISTICAL TESTS: Parameters were compared between patients with fibrosis grades F0-2 and F3-F4 with the Mann-Whitney U and fishers exact test. ROC analysis was used to assess the performance of the parameters to predict F3-4 fibrosis. A P-value <0.05 was considered statistically significant. RESULTS: ECV was significantly higher in F3-4 fibrosis (35.4% [33.1%-37.6%], 36.1% [34.2%-37.5%], and 37.0% [34.8%-39.2%] at 5/10/15 minutes) than in patients with F0-2 fibrosis (33.3% [30.8%-34.8%], 33.7% [31.6%-34.7%] and 34.9% [32.2%-36.0%]; AUC = 0.72-0.75). Blood pool T1 relaxation times in the aorta and vena cava were longer on the upper vs. lower slices at 5 minutes, but not at 10/15 minutes. AUC values were similar when measured on a single slice (AUC = 0.69-0.72) or based on blood pool measurements in the cava or portal vein (AUC = 0.63-0.67 and AUC = 0.65-0.70). DATA CONCLUSION: Liver ECV is significantly higher in F3-4 fibrosis compared to F0-2 fibrosis with blood pool measurements performed in the aorta, inferior vena cava, and portal vein at 5, 10, and 15 minutes. However, a smaller variability was observed for blood pool measurements between slices at 15 minutes. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 3.

2.
Eur Radiol ; 34(8): 4928-4938, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38197916

RESUMO

OBJECTIVES: Epicardial adipose tissue (EAT) remodeling is associated with atrial fibrillation (AF). Left atrial (LA) EAT dispersion on cardiac CT is a non-invasive imaging biomarker reflecting EAT heterogeneity. We aimed to investigate the association of LA EAT dispersion with AF recurrence after pulmonary vein isolation (PVI). METHODS: In a prospective registry of consecutive patients undergoing first PVI, mean EAT attenuation values were measured on contrast-enhanced cardiac CT scans in Hounsfield units (HU) within low (- 195 to - 45 HU) and high (- 44 to - 15 HU) threshold EAT compartments around the left atrium (LA). EAT dispersion was defined as the difference between the mean HU values within the two EAT compartments. Continuous variables were compared between groups using the Mann-Whitney U test and cox proportional hazard models were used to calculate hazard ratios of predictors of 1-year AF recurrence. RESULTS: A total of 208 patients were included, 135 with paroxysmal AF and 73 with persistent AF. LA EAT dispersion was significantly larger in patients with persistent compared to paroxysmal AF (52.6 HU vs. 49.9 HU; p = 0.001). After 1 year of follow-up, LA EAT dispersion above the mean (> 50.8 HU) was associated with a higher risk of AF recurrence (HR 2.3, 95% CI 1.5-3.6; p < 0.001). It retained its predictive value when corrected for age, sex, body mass index, LA volume, and AF type (HR 2.8, 95% CI 1.6-4.6; p < 0.001). CONCLUSION: A larger LA EAT dispersion on contrast-enhanced cardiac CT scans, reflecting EAT heterogeneity, is independently associated with AF recurrence after PVI. CLINICAL RELEVANCE STATEMENT: Based on LA EAT dispersion assessment, a more accurate risk stratification and patient selection may be possible based on a pre-procedural cardiac CT when planning PVI. KEY POINTS: • Epicardial adipose tissue (EAT) remodeling is associated with atrial fibrillation (AF). • A larger left atrial EAT dispersion in a pre-procedural cardiac CT was associated with a higher 1-year AF recurrence risk after pulmonary vein isolation. • A pre-procedural cardiac CT with left atrial EAT dispersion assessment may provide a more accurate risk stratification and patient selection for PVI.


Assuntos
Tecido Adiposo , Fibrilação Atrial , Pericárdio , Veias Pulmonares , Recidiva , Tomografia Computadorizada por Raios X , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Masculino , Feminino , Tecido Adiposo/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Pericárdio/diagnóstico por imagem , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Estudos Prospectivos , Idoso , Meios de Contraste , Ablação por Cateter/métodos , Sistema de Registros , Tecido Adiposo Epicárdico
3.
Radiology ; 305(1): 56-65, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35670718

RESUMO

Background The association of epicardial adipose tissue (EAT) and its metabolic activity with atrial fibrillation (AF) is an area of active investigation. Left atrial (LA) enhancing EAT (e-EAT) at cardiac CT may be a noninvasive surrogate marker for the metabolic activity of EAT. Purpose To determine the relationship between LA e-EAT and recurrence after AF ablation. Materials and Methods In a secondary analysis of a prospective registry of consecutive patients (from July 2018 to December 2019) undergoing first AF ablation, total and LA EAT were segmented on preprocedural noncontrast- and contrast-enhanced cardiac CT scans. LA e-EAT volume fraction was defined as the LA EAT volume difference between the noncontrast- and contrast-enhanced scan divided by the total LA EAT volume on the noncontrast-enhanced scan (threshold values, -15 HU to -195 HU). Continuous variables were compared between groups by using the Mann-Whitney U test. Cox proportional hazard models were used to calculate hazard ratios of predictors of 1-year AF recurrence. Results A total of 212 patients (mean age, 64 years; 159 men) who underwent a first AF ablation were included (paroxysmal AF, 64%; persistent AF, 36%). The LA EAT volume was higher in patients with persistent versus paroxysmal AF (50 cm3 [IQR, 37-72] vs 37 [IQR, 27-49]; P < .001), but no difference was found for LA e-EAT (P = .09). After 1 year of follow-up, AF recurrence rate was 77 of 212 (36%). LA e-EAT above the mean (>33%) was associated with a higher risk of AF recurrence (hazard ratio [HR], 2.1; 95% CI: 1.3, 3.3; P < .01). In a multivariable Cox regression analysis, LA e-EAT retained its predictive value when corrected for sex, age, AF phenotype, LA volume index, and LA EAT volume (HR, 1.9; 95% CI: 1.1, 3.1; P = .02). Conclusion Left atrial enhancing epicardial adipose tissue was independently associated with recurrence after atrial fibrillation ablation. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Stojanovska in this issue.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Tecido Adiposo/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração , Humanos , Recidiva , Tomografia Computadorizada por Raios X/métodos
4.
Eur Radiol ; 31(6): 4308-4318, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33313965

RESUMO

PURPOSE: To analyze whether the T1 relaxation time of the liver is a good predictor of significant liver fibrosis and whether normalization to the blood pool improves the predictive value. METHODS: This prospective study was conducted between 03/2016 and 02/2018. One hundred seventy-three patients underwent multiparametric liver MRI at 3 T. The T1 relaxation time was measured in the liver and the spleen, in the aorta, the portal vein, and the inferior vena cava (IVC). T1 relaxation times with and without normalization to the blood pool were compared between patients with (n = 26) and without (n = 141) significant liver fibrosis, based on a cutoff value of 3.5 kPa in MRE as the noninvasive reference standard. For statistics, Student's t test, receiver operating characteristic (ROC) curve analysis, and Pearson's correlation were used. RESULTS: The T1 relaxation time of the liver was significantly longer in patients with liver fibrosis, both with and without blood pool normalization (p < 0.001). T1 relaxation time of the liver allowed prediction of significant liver fibrosis (AUC = 0.88), while normalization to the IVC resulted in a slightly lower performance (AUC = 0.82). The lowest performance was achieved when the T1 relaxation times of the liver were normalized to the aorta (AUC = 0.66) and to the portal vein (AUC = 0.62). The T1 relaxation time of the spleen detected significant liver fibrosis with an AUC of 0.68, and 0.51-0.64 with normalization to the blood pool. CONCLUSION: The T1 relaxation time of the liver is a good predictor of significant liver fibrosis. However, normalization of the blood pool did not improve the predictive value. KEY POINTS: • The T1 relaxation time of the liver is a good predictor of significant liver fibrosis. • Normalization to the blood pool did not improve the predictive value of T1 mapping. • If the blood pool normalization was weighted 30% to the aorta and 70% to the portal vein, the performance was better than normalization to the aorta alone but still lower than normalization to the IVC.


Assuntos
Técnicas de Imagem por Elasticidade , Baço , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética , Estudos Prospectivos , Curva ROC , Baço/diagnóstico por imagem
5.
AJR Am J Roentgenol ; 215(1): 79-86, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32208004

RESUMO

OBJECTIVE. The purpose of this study was to test the hypothesis that patients with idiopathic dilated cardiomyopathy (IDCM) and heart failure have increased liver T1 relaxation times at MRI owing to congestion compared with the T1 relaxation times in patients with IDCM without heart failure and healthy control subjects. MATERIALS AND METHODS. For this retrospective cross-sectional study, 55 subjects (33 men, 22 women; mean age, 47 ± 15 years) who had undergone cardiac MRI were included: 20 healthy control subjects and 35 consecutively registered patients with IDCM. Twenty-one patients were hospitalized for acute heart failure, and 14 patients were in stable condition without heart failure. The performances of cardiac volume, left ventricular (LV) longitudinal strain, and ejection fraction (LVEF) in differentiating IDCM with and without heart failure were compared with myocardial and liver T1 relaxation times by means of Mann-Whitney U test and ROC analysis. RESULTS. The native T1 relaxation time of myocardium was significantly greater in patients with IDCM than in healthy control subjects (p < 0.001) but could not be used to differentiate between IDCM with and IDCM without heart failure (p = 0.653). Conversely, the native T1 relaxation time of liver was significantly greater in patients with IDCM and heart failure than in those without heart failure (p < 0.001). Native T1 relaxation time of liver was the overall best parameter for identifying the presence of heart failure in patients with IDCM (AUC, 0.96). It performed better than LVEF (AUC, 0.88) and global longitudinal LV strain (AUC, 0.85). CONCLUSION. Native T1 relaxation time of liver is an easily accessible and accurate noninvasive imaging marker of congestive heart failure in patients with IDCM. It can be measured on standard short-axis cardiac MRI T1-weighted maps and facilitates differentiating patients with IDCM with from those without heart failure more accurately than established functional parameters, such as LV volume, LVEF, and LV strain.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Fígado/diagnóstico por imagem , Fígado/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Cardiomiopatia Dilatada/complicações , Estudos de Casos e Controles , Meios de Contraste , Estudos Transversais , Diagnóstico Diferencial , Feminino , Insuficiência Cardíaca/complicações , Testes de Função Cardíaca , Humanos , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Compostos Organometálicos , Estudos Retrospectivos
6.
ASAIO J ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38728741

RESUMO

Left ventricular assist devices (LVADs) improve symptoms and outcomes in patients with advanced heart failure. We report the case of a patient with a freshly implanted HeartMate 3 LVAD, suffering abruptly on postoperative day 55 from pejoration of his heart failure with multiple episodes of low-flow alarm. Outflow graft obstruction (OGO) due to local aortic dissection was diagnosed with multimodality imaging. After a multidisciplinary discussion, a surgical approach was decided, and the patient benefited from a revision of his outflow graft.

7.
Sci Rep ; 14(1): 22447, 2024 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-39341945

RESUMO

The study aimed to evaluate the impact of AI assistance on pulmonary nodule detection rates among radiology residents and senior radiologists, along with assessing the effectiveness of two different commercialy available AI software systems in improving detection rates and LungRADS classification in chest CT. The study cohort included 198 participants with 221 pulmonary nodules. Residents' mean detection rate increased significantly from 64 to 77% with AI assist, while seniors' detection rate remained largely unchanged (85% vs. 86%). Residents showed significant improvement in segmental nodule localization with AI assistance, seniors did not. Software 2 slightly outperformed software 1 in increasing detection rates (67-77% vs. 80-86%), but neither significantly affected LungRADS classification. The study suggests that clinical experience mitigates the need for additional AI software, with the combination of CAD with residents being the most beneficial approach. Both software systems performed similarly, with software 2 showing a slightly higher but non-significant increase in detection rates.


Assuntos
Inteligência Artificial , Neoplasias Pulmonares , Radiologistas , Nódulo Pulmonar Solitário , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Tomografia Computadorizada por Raios X/métodos , Pessoa de Meia-Idade , Neoplasias Pulmonares/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico por imagem , Idoso , Adulto , Software , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Nódulos Pulmonares Múltiplos/diagnóstico por imagem
8.
Abdom Radiol (NY) ; 2024 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-39254712

RESUMO

PURPOSE: This study aimed to analyze the predictive value of caudate to right lobe ratio (CRL-R) and liver segmental volume ratio (LSVR) for chronic liver disease (CLD) on routine abdominal CT scans and their association with 5-year decompensation- and transplant-free survival. METHOD: This retrospective study included 108 patients without CLD and 98 patients with biopsy-proven CLD. All patients underwent abdominal CT scans between 03/2015 and 08/2017. Patients with CLD were divided into three groups: early CLD (F0-F2; eCLD; n = 40), advanced CLD (F3-F4; aCLD; n = 20), and aCLD with clinically significant portal hypertension (aCLDPH; n = 38). CRL-R and LSVR were compared between groups using Kruskal-Wallis test and ROC analysis to determine cutoff-values. 5-year decompensation- and transplant-free survival were assessed by Kaplan-Meier curve analysis. RESULTS: CRL-R and LSVR were significantly different between all groups (p < 0.001). A CRL-R cutoff-value of > 0.99 predicted aCLD with a sensitivity of 69% and a specificity of 80% (AUC = 0.75, p < 0.001), while LSVR > 0.37 had a sensitivity of 67% and a specificity of 84% (AUC = 0.80, p < 0.001). CLD-patients with both CRL-R > 0.99 and LSVR > 0.37 had a significantly lower probability of 5-year decompensation-free survival (31%) as well as lower probability of 5-year transplant-free survival (41%) than those with a CRL-R < 0.99 and/or LSVR < 0.37 (70%, 62%, p = 0.006, p = 0.038). CONCLUSION: CRL-R and LSVR showed a high predictive value for CLD on routine abdominal CT scans. In patients with CLD, both CRL-R and LSVR may be combined and are associated with 5-year decompensation-free and transplant-free survival.

9.
Diagnostics (Basel) ; 14(15)2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39125461

RESUMO

To determine the diagnostic performance of simulated reduced-dose chest CT scans regarding pulmonary T1 tumors and assess the potential impact on patient management, a repository of 218 patients with histologically proven pulmonary T1 tumors was used. Virtual reduced-dose images were simulated at 25%- and 5%-dose levels. Tumor size, attenuation, and localization were scored by two experienced chest radiologists. The impact on patient management was assessed by comparing hypothetical LungRADS scores. The study included 210 patients (41% females, mean age 64.5 ± 9.2 years) with 250 eligible T1 tumors. There were differences between the original and the 5%-but not the 25%-dose simulations, and LungRADS scores varied between the dose levels with no clear trend. Sensitivity of Reader 1 was significantly lower using the 5%-dose vs. 25%-dose vs. original dose for size categorization (0.80 vs. 0.85 vs. 0.84; p = 0.007) and segmental localization (0.81 vs. 0.86 vs. 0.83; p = 0.018). Sensitivities of Reader 2 were unaffected by a dose reduction. A CT dose reduction may affect the correct categorization and localization of pulmonary T1 tumors and potentially affect patient management.

10.
Eur J Radiol ; 167: 111047, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37690351

RESUMO

PURPOSE: To evaluate the effectiveness of automated liver segmental volume quantification and calculation of the liver segmental volume ratio (LSVR) on a non-contrast T1-vibe Dixon liver MRI sequence using a deep learning segmentation pipeline. METHOD: A dataset of 200 liver MRI with a non-contrast 3 mm T1-vibe Dixon sequence was manually labeledslice-by-sliceby an expert for Couinaud liver segments, while portal and hepatic veins were labeled separately. A convolutional neural networkwas trainedusing 170 liver MRI for training and 30 for evaluation. Liver segmental volumes without liver vessels were retrieved and LSVR was calculated as the liver segmental volumes I-III divided by the liver segmental volumes IV-VIII. LSVR was compared with the expert manual LSVR calculation and the LSVR calculated on CT scans in 30 patients with CT and MRI within 6 months. RESULTS: Theconvolutional neural networkclassified the Couinaud segments I-VIII with an average Dice score of 0.770 ± 0.03, ranging between 0.726 ± 0.13 (segment IVb) and 0.810 ± 0.09 (segment V). The calculated mean LSVR with liver MRI unseen by the model was 0.32 ± 0.14, as compared with manually quantified LSVR of 0.33 ± 0.15, resulting in a mean absolute error (MAE) of 0.02. A comparable LSVR of 0.35 ± 0.14 with a MAE of 0.04 resulted with the LSRV retrieved from the CT scans. The automated LSVR showed significant correlation with the manual MRI LSVR (Spearman r = 0.97, p < 0.001) and CT LSVR (Spearman r = 0.95, p < 0.001). CONCLUSIONS: A convolutional neural network allowed for accurate automated liver segmental volume quantification and calculation of LSVR based on a non-contrast T1-vibe Dixon sequence.


Assuntos
Aprendizado Profundo , Humanos , Fígado/diagnóstico por imagem , Radiografia , Cintilografia , Imageamento por Ressonância Magnética
11.
Sci Rep ; 12(1): 22059, 2022 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-36543852

RESUMO

We evaluated the effectiveness of automated segmentation of the liver and its vessels with a convolutional neural network on non-contrast T1 vibe Dixon acquisitions. A dataset of non-contrast T1 vibe Dixon liver magnetic resonance images was labelled slice-by-slice for the outer liver border, portal, and hepatic veins by an expert. A 3D U-Net convolutional neural network was trained with different combinations of Dixon in-phase, opposed-phase, water, and fat reconstructions. The neural network trained with the single-modal in-phase reconstructions achieved a high performance for liver parenchyma (Dice 0.936 ± 0.02), portal veins (0.634 ± 0.09), and hepatic veins (0.532 ± 0.12) segmentation. No benefit of using multi-modal input was observed (p = 1.0 for all experiments), combining in-phase, opposed-phase, fat, and water reconstruction. Accuracy for differentiation between portal and hepatic veins was 99% for portal veins and 97% for hepatic veins in the central region and slightly lower in the peripheral region (91% for portal veins, 80% for hepatic veins). In conclusion, deep learning-based automated segmentation of the liver and its vessels on non-contrast T1 vibe Dixon was highly effective. The single-modal in-phase input achieved the best performance in segmentation and differentiation between portal and hepatic veins.


Assuntos
Fígado , Redes Neurais de Computação , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Veia Porta/diagnóstico por imagem , Água , Processamento de Imagem Assistida por Computador/métodos
12.
Sci Rep ; 12(1): 4716, 2022 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-35304554

RESUMO

Magnetic resonance T1 mapping before and after Gd-EOB-DTPA administration allows quantification of the T1 reduction rate as a non-invasive surrogate marker of liver function. A major limitation of T1 relaxation time measurement is its dependency on MRI field strengths. Since T1 reduction rate is calculated as the relative shortening of T1 relaxation time before and after contrast administration, we hypothesized that the T1 reduction rate is comparable between 1.5 and 3 T. We thus compared liver T1 relaxation times between 1.5 and 3 T in a total of 243 consecutive patients (124, 1.5 T and 119, 3 T) between 09/2018 and 07/2019. T1 reduction rates were compared between patients with no cirrhosis and patients with cirrhosis Child-Pugh A-C. There was no significant difference of T1 reduction rate between 1.5 and 3 T in any patient group (p-value 0.126-0.861). On both 1.5 T and 3 T, T1 reduction rate allowed to differentiate between patients with no cirrhosis and patients with liver cirrhosis Child A-C (p < 0.001). T1 reduction rate showed a good performance to predict liver cirrhosis Child A (AUC = 0.83, p < 0.001), Child B (AUC = 0.83, p < 0.001) and Child C (AUC = 0.92, p < 0.001). In conclusion, T1 reduction rate allows to determine liver function on Gd-EOB-DTPA MRI with comparable values on 1.5 T and 3 T.


Assuntos
Meios de Contraste , Gadolínio DTPA , Humanos , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética
13.
Eur Heart J Case Rep ; 5(3): ytab081, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33718769

RESUMO

BACKGROUND: Anomalous aortic origin of a coronary artery (AAOCA) is a rare congenital disease associated with an increased risk of myocardial ischaemia, ventricular arrhythmias, and heart failure. CASE SUMMARY: A 75-year-old Caucasian man was referred for invasive coronary angiography (ICA) due to atypical chest pain. Invasive coronary angiography demonstrated non-significant atherosclerotic disease of the left coronary artery and an anomalous origin of the right coronary artery (RCA); without selective intubation. Coronary computed tomography angiography (CCTA) revealed a right-AAOCA with interarterial and intramural course, and a soft plaque in the distal RCA. Subsequent physical-stress single-photon emissions computed tomography (SPECT) showed exercise-induced inferoapical myocardial ischaemia, giving a Class IC level of evidence for surgical correction of the AAOCA. Repeated ICA with selective R-AAOCA intubation confirmed an 80% distal atherosclerotic stenosis, which was treated with direct stenting. Subsequent invasive physiologic evaluation under maximal dobutamine-volume challenge (gradually increasing dose of dobutamine max. 40 µg/kg per body weight/min, 3000 mL ringer lactate and 1 mg atropine was given until the patient reached a maximum of 145 b.p.m.), revealed a haemodynamically non-relevant anomalous segment with a fractional flow reserve (FFR) of 0.91. A follow-up SPECT was normal, and the patient was completely symptom-free at 1 month. DISCUSSION: We present the sequential diagnostic approach in a symptomatic patient with a right anomalous coronary artery and concomitant atherosclerotic disease. Using this approach, the patient could be deferred from guideline recommended open-heart surgery of the AAOCA, as direct invasive dobutamine/volume FFR revealed haemodynamic non-relevance of the anomalous segment after stenting the concomitant atherosclerotic stenosis in the distal segment within the same coronary artery.

14.
Clin Nucl Med ; 46(12): e577-e578, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34269733

RESUMO

ABSTRACT: A 70-year-old man presented with unspecific abdominal symptoms and weight loss was referred for a sonographic examination. Sonography revealed 3 cystic hepatic masses in an otherwise unremarkable liver. Contrast-enhanced MRI of the liver was performed to characterize the hepatic lesions and elucidate their etiology. The differential diagnosis was primarily parasitic disease or metastases with cystic transformations. 68Ga-DOTATOC PET/CT revealed the neuroendocrine origin of these lesions, confirmed by biopsy. However, the primary site of the neuroendocrine tumor remained unclear, leaving primary hepatic neuroendocrine tumor and neuroendocrine cancer of unknown primary as possible diagnostic options.


Assuntos
Neoplasias Intestinais , Tumores Neuroendócrinos , Compostos Organometálicos , Neoplasias Pancreáticas , Neoplasias Gástricas , Idoso , Humanos , Masculino , Tumores Neuroendócrinos/diagnóstico por imagem , Octreotida , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
15.
Radiol Case Rep ; 16(2): 327-333, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33318775

RESUMO

Langerhans cell histiocytosis (LCH) is a myeloid neoplasm with inflammatory properties. There are few published reports of adult LCH with liver involvement, which is still poorly understood, but shows high morbidity and mortality. We report a case of a 37-year-old woman suffering from hepatitis C showing a LCH affecting the lung as well as the liver. Consistent with histology, we found an early stage of a proliferative/granulomatous phase of hepatobiliary LCH, whereas pulmonary findings showed a nodular stage of adult pulmonary LCH. Although hepatocellular carcinoma is a common malignancy in patients suffering from hepatitis C, it is crucial to keep in mind differential diagnosis for newly appearing liver lesions.

16.
Abdom Radiol (NY) ; 46(10): 4536-4547, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34114087

RESUMO

PURPOSE: To analyze the amount of free abdominal gas and ascites on computed tomography (CT) images relative to the location of a perforation. METHODS: We retrospectively included 172 consecutive patients (93:79 = m:f) with GIT perforation, who underwent abdominal surgery (ground truth for perforation location). The volume of free air and ascites were quantified on CT images by 4 radiologists and a semiautomated software. The relation of the perforation location (upper/lower GIT) and amount of free air and ascites was analyzed by the Mann-Whitney test. Furthermore, best volume cutoff for upper and lower GIT perforation, areas under the curve (AUC), and interreader volume agreement were assessed. RESULTS: There was significantly more abdominal ascites with upper GIT perforation (333 ml, range 5 to 2000 ml) than with lower GIT perforation (100 ml, range 5 to 2000 ml, p = 0.022). The highest volume of free air was found with perforations of the stomach, descending colon and sigmoid colon. Significantly less free air was found with perforations of the small bowel and ascending colon compared to the aforementioned. An ascites volume > 333 ml was associated with an upper GIT perforation demonstrating an AUC of 0.63 ± 0.04. CONCLUSION: Using a two-step process based on the volumes of free air and free fluid can help localizing the site of perforation to the upper, middle or lower GI tract.


Assuntos
Traumatismos Abdominais , Perfuração Intestinal , Ascite/diagnóstico por imagem , Humanos , Perfuração Intestinal/diagnóstico por imagem , Perfuração Intestinal/cirurgia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
17.
Eur J Radiol ; 144: 109958, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34571458

RESUMO

PURPOSE: To analyze the predictive value of ΔT1 of the liver and spleen as well as the extracellular volume fraction (ECV) of the spleen as noninvasive biomarkers for the determination of clinically significant portal hypertension (CSPH) on routine Gd-EOB-DTPA liver MRI. METHOD: 195 consecutive patients with known or suspected chronic liver disease from 9/2018 to 7/2019 with Gd-EOB-DTPA liver MRI and abdominal T1 mapping were retrospectively included. Based on the presence of splenomegaly with thrombocytopenia, ascites and portosystemic collaterals, the patients were divided into noCSPH (n = 113), compensated CSPH (cCSPH, ≥1 finding without ascites; n = 55) and decompensated CSPH (dCSPH, ascites ± other findings; n = 27). T1 times were measured in the liver, spleen and abdominal aorta in the unenhanced and contrast-enhanced T1 maps. Native T1 times and ΔT1 of the liver and spleen as well as ECV of the spleen were compared between groups using the Kruskal-Wallis test with Dunn's post hoc test. Furthermore, cutoff values for group differentiation were calculated using ROC analysis with Youden's index. RESULTS: ΔT1 of the liver was significantly lower in patients with cCSPH and dCSPH (p < 0.001) compared to patients with noCSPH. In the ROC analyses for differentiation between noCSPH and CSPH (cCSPH + dCSPH), a cutoff of < 0.67 for ΔT1 of the liver (AUC = 0.79) performed better than ΔT1 (AUC = 0.69) and ECV (AUC = 0.63) of the spleen with cutoffs of > 0.29 and > 41.9, respectively. CONCLUSION: ΔT1 of the liver and spleen in addition to ECV of the spleen allow for determination of CSPH on routine Gd-EOB-DTPA liver MRI.


Assuntos
Hipertensão Portal , Baço , Meios de Contraste , Gadolínio DTPA , Humanos , Hipertensão Portal/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Baço/diagnóstico por imagem
18.
Invest Radiol ; 51(1): 25-32, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26619283

RESUMO

OBJECTIVE: The aim of this study was to investigate the performance of the arterial enhancement fraction (AEF) in multiphasic computed tomography (CT) acquisitions to detect hepatocellular carcinoma (HCC) in liver transplant recipients in correlation with the pathologic analysis of the corresponding liver explants. MATERIALS AND METHODS: Fifty-five transplant recipients were analyzed: 35 patients with 108 histologically proven HCC lesions and 20 patients with end-stage liver disease without HCC. Six radiologists looked at the triphasic CT acquisitions with the AEF maps in a first readout. For the second readout without the AEF maps, 3 radiologists analyzed triphasic CT acquisitions (group 1), whereas the other 3 readers had 4 contrast acquisitions available (group 2). A jackknife free-response reader receiver operating characteristic analysis was used to compare the readout performance of the readers. Receiver operating characteristic analysis was used to determine the optimal cutoff value of the AEF. RESULTS: The figure of merit (θ = 0.6935) for the conventional triphasic readout was significantly inferior compared with the triphasic readout with additional use of the AEF (θ = 0.7478, P < 0.0001) in group 1. There was no significant difference between the fourphasic conventional readout (θ = 0.7569) and the triphasic readout (θ = 0.7615, P = 0.7541) with the AEF in group 2. Without the AEF, HCC lesions were detected with a sensitivity of 30.7% (95% confidence interval [CI], 25.5%-36.4%) and a specificity of 97.1% (96.0%-98.0%) by group 1 looking at 3 CT acquisition phases and with a sensitivity of 42.1% (36.2%-48.1%) and a specificity of 97.5% (96.4%-98.3%) in group 2 looking at 4 CT acquisition phases. Using the AEF maps, both groups looking at the same 3 acquisition phases, the sensitivity was 47.7% (95% CI, 41.9%-53.5%) with a specificity of 97.4% (96.4%-98.3%) in group 1 and 49.8% (95% CI, 43.9%-55.8%)/97.6% (96.6%-98.4%) in group 2. The optimal cutoff for the AEF was 50%. CONCLUSION: The AEF is a helpful tool to screen for HCC with CT. The use of the AEF maps may significantly improve HCC detection, which allows omitting the fourth CT acquisition phase and thus making a 25% reduction of radiation dose possible.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Transplante de Fígado , Tomografia Computadorizada por Raios X/métodos , Artérias , Carcinoma Hepatocelular/patologia , Humanos , Neoplasias Hepáticas/patologia , Intensificação de Imagem Radiográfica , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA