Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 145
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 34(8): 1698-1705, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37493499

RESUMO

INTRODUCTION: Among patients with non-valvular atrial fibrillation (AF) and percutaneous left atrial appendage closure (LAAC) undergoing direct current cardioversion (DCCV), the need for and use of LAA imaging and oral anticoagulation (OAC) is unclear. OBJECTIVE: The purpose of this study is to evaluate the real-world use of transesophageal echocardiography (TEE) or cardiac computed tomography angiography (CCTA) before DCCV and use of OAC pre- and post-DCCV in patients with AF status post percutaneous LAAC. METHODS: This retrospective single center study included all patients who underwent DCCV after percutaneous LAAC from 2016 to 2022. Key measures were completion of TEE or CCTA pre-DCCV, OAC use pre- and post-DCCV, incidence of left atrial thrombus (LAT) or device-related thrombus (DRT), incidence of peri-device leak (PDL), and DCCV-related complications (stroke, systemic embolism, device embolization, major bleeding, or death) within 30 days. RESULTS: A total of 76 patients with AF and LAAC underwent 122 cases of DCCV. LAAC consisted of 47 (62%), 28 (37%), and 1 (1%) case of Watchman 2.5, Watchman FLX, and Lariat, respectively. Among the 122 DCCV cases, 31 (25%) cases were identified as "non-guideline based" due to: (1) no OAC for 3 weeks and no LAA imaging within 48 h before DCCV in 12 (10%) cases, (2) no OAC for 4 weeks following DCCV in 16 (13%) cases, or (3) both in 3 (2%) cases. Among the 70 (57%) cases that underwent TEE or CCTA before DCCV, 16 (23%) cases had a PDL with a mean size of 3.0 ± 1.1 mm, and 4 (6%) cases had a LAT/DRT on TEE resulting in cancellation. There were no DCCV-related complications within 30 days. DISCUSSION: There is a widely varied practice pattern of TEE, CCTA, and OAC use with DCCV after LAAC, with a 6% rate of LAT/DRT. LAA imaging before DCCV appears prudent in all cases, especially within 1 year of LAAC, to assess for device position, PDL, and LAT/DRT.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardiopatias , Acidente Vascular Cerebral , Trombose , Humanos , Estudos Retrospectivos , Cardioversão Elétrica/efeitos adversos , Apêndice Atrial/diagnóstico por imagem , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/prevenção & controle , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Ecocardiografia Transesofagiana , Resultado do Tratamento , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Cateterismo Cardíaco/efeitos adversos
2.
Pacing Clin Electrophysiol ; 46(7): 745-751, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37221927

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) and cardiac computed tomography angiography (CCTA) are currently utilized for left atrial appendage closure (LAAC) planning. During the recent global iodine contrast media shortage in 2022, cardiac magnetic resonance imaging (CMR) was utilized for the first time for LAAC planning. This study sought to assess the utility of CMR versus TEE for LAAC planning. METHODS: This single center retrospective study consisted of all patients who underwent preoperative CMR for LAAC with Watchman FLX or Amplatzer Amulet. Key measures were accuracy of LAA thrombus exclusion, ostial diameter, depth, lobe count, morphology, accuracy of predicted device size, and devices deployed per case. Bland-Altman Analysis was used to compare CMR versus TEE measurements of LAA ostial diameter and depth. RESULTS: 25 patients underwent preoperative CMR for LAAC planning. A total of 24 (96%) cases were successfully completed with 1.2 ± 0.5 devices deployed per case. Among the 18 patients who underwent intraoperative TEE, there was no significant difference between CMR versus TEE in LAA thrombus exclusion (CMR 83% vs. TEE 100% cases, p = .229), lobe count (CMR 1.7 ± 0.8 vs. TEE 1.4 ± 0.6, p = .177), morphology (p = .422), and accuracy of predicted device size (CMR 67% vs. TEE 72% cases, p = 1.000). When comparing the difference between CMR and TEE measurements, Bland-Altman analysis demonstrated no significant difference in LAA ostial diameter (CMR-TEE bias 0.7 mm, 95% CI [-1.1, 2.4], p = .420), but LAA depth was significantly larger with CMR versus TEE (CMR-TEE bias 7.4 mm, 95% CI [1.6, 13.2], p = .015). CONCLUSIONS: CMR is a promising alternative for LAAC planning in cases where TEE or CCTA are contraindicated or unavailable.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Trombose , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Ecocardiografia Transesofagiana/métodos , Imageamento por Ressonância Magnética , Trombose/diagnóstico por imagem , Cateterismo Cardíaco , Resultado do Tratamento
3.
Behav Brain Sci ; 46: e415, 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38054298

RESUMO

On several key issues we agree with the commentators. Perhaps most importantly, everyone seems to agree that psychology has an important role to play in building better models of human vision, and (most) everyone agrees (including us) that deep neural networks (DNNs) will play an important role in modelling human vision going forward. But there are also disagreements about what models are for, how DNN-human correspondences should be evaluated, the value of alternative modelling approaches, and impact of marketing hype in the literature. In our view, these latter issues are contributing to many unjustified claims regarding DNN-human correspondences in vision and other domains of cognition. We explore all these issues in this response.


Assuntos
Cognição , Redes Neurais de Computação , Humanos
4.
Behav Brain Sci ; 46: e385, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36453586

RESUMO

Deep neural networks (DNNs) have had extraordinary successes in classifying photographic images of objects and are often described as the best models of biological vision. This conclusion is largely based on three sets of findings: (1) DNNs are more accurate than any other model in classifying images taken from various datasets, (2) DNNs do the best job in predicting the pattern of human errors in classifying objects taken from various behavioral datasets, and (3) DNNs do the best job in predicting brain signals in response to images taken from various brain datasets (e.g., single cell responses or fMRI data). However, these behavioral and brain datasets do not test hypotheses regarding what features are contributing to good predictions and we show that the predictions may be mediated by DNNs that share little overlap with biological vision. More problematically, we show that DNNs account for almost no results from psychological research. This contradicts the common claim that DNNs are good, let alone the best, models of human object recognition. We argue that theorists interested in developing biologically plausible models of human vision need to direct their attention to explaining psychological findings. More generally, theorists need to build models that explain the results of experiments that manipulate independent variables designed to test hypotheses rather than compete on making the best predictions. We conclude by briefly summarizing various promising modeling approaches that focus on psychological data.


Assuntos
Redes Neurais de Computação , Percepção Visual , Humanos , Percepção Visual/fisiologia , Visão Ocular , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Imageamento por Ressonância Magnética/métodos
5.
J Mol Cell Cardiol ; 151: 56-71, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33130148

RESUMO

Atrial fibrillation (AF) occurrence and maintenance is associated with progressive remodeling of electrophysiological (repolarization and conduction) and 3D structural (fibrosis, fiber orientations, and wall thickness) features of the human atria. Significant diversity in AF etiology leads to heterogeneous arrhythmogenic electrophysiological and structural substrates within the 3D structure of the human atria. Since current clinical methods have yet to fully resolve the patient-specific arrhythmogenic substrates, mechanism-based AF treatments remain underdeveloped. Here, we review current knowledge from in-vivo, ex-vivo, and in-vitro human heart studies, and discuss how these studies may provide new insights on the synergy of atrial electrophysiological and 3D structural features in AF maintenance. In-vitro studies on surgically acquired human atrial samples provide a great opportunity to study a wide spectrum of AF pathology, including functional changes in single-cell action potentials, ion channels, and gene/protein expression. However, limited size of the samples prevents evaluation of heterogeneous AF substrates and reentrant mechanisms. In contrast, coronary-perfused ex-vivo human hearts can be studied with state-of-the-art functional and structural technologies, such as high-resolution near-infrared optical mapping and contrast-enhanced MRI. These imaging modalities can resolve atrial arrhythmogenic substrates and their role in reentrant mechanisms maintaining AF and validate clinical approaches. Nonetheless, longitudinal studies are not feasible in explanted human hearts. As no approach is perfect, we suggest that combining the strengths of direct human atrial studies with high fidelity approaches available in the laboratory and in realistic patient-specific computer models would elucidate deeper knowledge of AF mechanisms. We propose that a comprehensive translational pipeline from ex-vivo human heart studies to longitudinal clinically relevant AF animal studies and finally to clinical trials is necessary to identify patient-specific arrhythmogenic substrates and develop novel AF treatments.


Assuntos
Fibrilação Atrial/fisiopatologia , Fenômenos Eletrofisiológicos , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Imageamento Tridimensional , Miocárdio/patologia , Inteligência Artificial , Humanos
6.
J Cardiovasc Electrophysiol ; 32(11): 3027-3034, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34554620

RESUMO

INTRODUCTION: Defibrillation testing (DT) is recommended during the subcutaneous defibrillator (S-ICD) placement. We sought to compare 10 J shock impedance in sinus rhythm (SR) with 65 J defibrillation impedance and evaluate device position on a postimplant chest X-ray (CXR) using an intermuscular (IM) technique. METHODS: Consecutive S-ICD implantations between 12/2019 and 12/2020 at The Ohio State University were reviewed. All implantations were performed using a two-incision IM technique. Standard DT with 65 J shock and 10 J shock in SR were performed unless contraindicated. The PRAETORIAN score was calculated based on CXR. RESULTS: A total of 37 patients (age: 47.2 ± 15.8 years old, male: n = 26 [70.3%], body mass index: 30.1 ± 6.7 kg/m2 ) underwent IM S-ICD implantation, and of those, 27 (73%) underwent both 65 J shock and 10 J shock in SR. The coefficient of determination (R2 ) between 10 J shock impedance and 65 J shock impedance was 0.84. The mean of an impedance difference was 1.6 ± 4.8 Ω (minimum - 11 and maximum 8). Postimplant CXR was available for 33 out of 37 patients (89.2%). The PRAETORIAN score was less than 90 in all patients and the mean score was 32.7 ± 8.8. CONCLUSION: We demonstrated that 10 J shock impedance in SR correlated well with 65 J defibrillation impedance during IM S-ICD implantation. An IM implantation technique provides excellent generator location on postimplant CXR. The IM technique combined with 10 J shock in SR may be sufficient to predict and ensure the defibrillation efficacy of the S-ICD.


Assuntos
Desfibriladores Implantáveis , Adulto , Arritmias Cardíacas , Cardioversão Elétrica , Impedância Elétrica , Humanos , Masculino , Pessoa de Meia-Idade , Ohio , Tela Subcutânea
7.
J Cardiovasc Electrophysiol ; 32(2): 477-483, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33205561

RESUMO

INTRODUCTION: Frequent right AQ4ventricular pacing (≥40%) with a transvenous pacemaker (TVP) is associated with the risk of pacing-induced cardiomyopathy (PICM). Leadless pacemakers (LPs) have distinct physical and mechanical differences from TVP. The risk of PICM with LP is not known. To identify incidence, predictors, and long-term outcomes of PICM in LP and TVP patients. METHODS: The study comprised all pacemaker-dependent patients with LP or TVP who had left ventricular ejection fraction (LVEF) of ≥50 from 2014 to 2019. The incidence of PICM (≥10% LVEF drop) was assessed with an echocardiogram. Predictors for PICM were identified using multivariate analysis. Long-term outcomes after cardiac resynchronization (CRT) were assessed in both groups. RESULTS: A total of 131 patients with TVP and 67 with LP comprised the study. All patients in the TVP group and the majority in the LP group underwent atrioventricular node ablation. The mean follow-up duration in TVP and LP groups was 592 ± 549 and 817 ± 600 days, respectively. A total of 18 (13.7%) patients in TVP and 2 (3%) in LP developed PICM after a median duration of 254 (interquartile range: 470) days. The incidence of PICM was significantly higher with TVP compared with LP (p = .02). TVP as pacing modality was a positive (odds ratio [OR]: 1.07) while age was negative (OR: 0.94) predictor for PICM on multivariable analysis. Both patients in LP and all except two in the TVP group responded to CRT. CONCLUSION: Incidence of PICM is significantly lower with LP compared with TVP in pacemaker-dependent patients. Age and TVP as pacing modality were predictors for PICM.


Assuntos
Cardiomiopatias , Marca-Passo Artificial , Estimulação Cardíaca Artificial/efeitos adversos , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/epidemiologia , Humanos , Incidência , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
8.
J Cardiovasc Electrophysiol ; 31(6): 1289-1297, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32270538

RESUMO

INTRODUCTION: The VICTORY AF Study was designed to evaluate the risk of the procedure and/or device-related strokes in patients with PersAF on warfarin undergoing ablation with a phased radiofrequency (RF) system. METHODS: The VICTORY AF trial was a prospective, multicenter, single-arm, investigational study. PersAF patients on vitamin K antagonism without major structural heart disease or history of stroke/transient ischemic attack undergoing phased RF ablation for atrial fibrillation (AF) were included. The primary outcome was the incidence of the procedure and/or device-related stroke within 30 days of the ablation by a board-certified neurologist's assessment. The secondary outcomes were an acute procedural success, 6 months effectiveness (defined as the reduction in AF/atrial flutter episodes lasting ≥10 minutes by 48-hour Holter 6 months postablation) and the number of patients with pulmonary vein (PV) stenosis. RESULTS: A total of 129 (108 PersAF, 21 long-standing PersAF) patients were treated (mean age: 60.6 ± 7.7; 79.8% male, 54.3% CHA2Ds2-VASc score ≥ 2). Two nondisabling strokes were reported (1.6%); one before discharge and the second diagnosed at the 30-day visit. Due to slow enrollment, the study was terminated before reaching the 95% one-sided upper confidence boundary for stroke incidence. Acute procedural success was 93.8%, and at 6 months, 72.8% of patients demonstrated ≥90% reduction in AF burden, 78.9% were off all antiarrhythmic drugs. There were no patients with PV stenosis of greater than 70%. CONCLUSIONS: VICTORY AF demonstrated a 1.6% incidence of stroke in PersAF undergoing ablation with a phased RF system which did not meet statistical confidence due to poor enrollment. The secondary outcomes suggest comparable efficacy to phased RF in the tailored treatment of permanent AF trial. Rigorous clinical evaluation of the stroke risk of new AF ablation technologies as well as restriction to Vitamin K antagonist anticoagulation appears to be unachievable goals in a clinical multicenter IDE trial of AF ablation in the current era.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Eletrodos , Acidente Vascular Cerebral Hemorrágico/epidemiologia , AVC Isquêmico/epidemiologia , Potenciais de Ação , Idoso , Anticoagulantes/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Feminino , Frequência Cardíaca , Acidente Vascular Cerebral Hemorrágico/diagnóstico , Acidente Vascular Cerebral Hemorrágico/prevenção & controle , Humanos , Incidência , AVC Isquêmico/diagnóstico , AVC Isquêmico/prevenção & controle , Masculino , Pessoa de Meia-Idade , América do Norte/epidemiologia , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Varfarina/uso terapêutico
9.
N Engl J Med ; 374(6): 533-41, 2016 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-26551877

RESUMO

BACKGROUND: A leadless intracardiac transcatheter pacing system has been designed to avoid the need for a pacemaker pocket and transvenous lead. METHODS: In a prospective multicenter study without controls, a transcatheter pacemaker was implanted in patients who had guideline-based indications for ventricular pacing. The analysis of the primary end points began when 300 patients reached 6 months of follow-up. The primary safety end point was freedom from system-related or procedure-related major complications. The primary efficacy end point was the percentage of patients with low and stable pacing capture thresholds at 6 months (≤2.0 V at a pulse width of 0.24 msec and an increase of ≤1.5 V from the time of implantation). The safety and efficacy end points were evaluated against performance goals (based on historical data) of 83% and 80%, respectively. We also performed a post hoc analysis in which the rates of major complications were compared with those in a control cohort of 2667 patients with transvenous pacemakers from six previously published studies. RESULTS: The device was successfully implanted in 719 of 725 patients (99.2%). The Kaplan-Meier estimate of the rate of the primary safety end point was 96.0% (95% confidence interval [CI], 93.9 to 97.3; P<0.001 for the comparison with the safety performance goal of 83%); there were 28 major complications in 25 of 725 patients, and no dislodgements. The rate of the primary efficacy end point was 98.3% (95% CI, 96.1 to 99.5; P<0.001 for the comparison with the efficacy performance goal of 80%) among 292 of 297 patients with paired 6-month data. Although there were 28 major complications in 25 patients, patients with transcatheter pacemakers had significantly fewer major complications than did the control patients (hazard ratio, 0.49; 95% CI, 0.33 to 0.75; P=0.001). CONCLUSIONS: In this historical comparison study, the transcatheter pacemaker met the prespecified safety and efficacy goals; it had a safety profile similar to that of a transvenous system while providing low and stable pacing thresholds. (Funded by Medtronic; Micra Transcatheter Pacing Study ClinicalTrials.gov number, NCT02004873.).


Assuntos
Arritmias Cardíacas/terapia , Marca-Passo Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Eletrodos Implantados , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Estudos Prospectivos , Adulto Jovem
10.
J Cardiovasc Electrophysiol ; 30(11): 2453-2459, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31502324

RESUMO

BACKGROUND: An internal risk stratification algorithm was developed to decrease the risk of major adverse cardiac events (MACEs) during lead extractions (LEs). OBJECTIVE: To report upon the impact of a risk stratification algorithm (RISE [RIsk Stratification prior to lead Extraction] protocol) on outcomes of LEs in a high-volume center. METHODS: A retrospective review of a prospectively maintained LEs database was performed to identify features associated with MACEs. On the basis of the retrospective data, the RISE protocol differentiated LEs procedures into "High" and "Low" risk for occurrence of MACEs. High-risk LEs included dual-coil defibrillator lead (≥3 years), pacemaker and single-coil lead (≥5 years), and any StarFix coronary sinus lead. During the prospective evaluation of the RISE protocol, "High-risk" LEs were performed in an operating room (OR) or hybrid laboratory with the cardiac anesthesiologist, OR nursing team, perfusionist in the room, and a cardiac surgeon on the premises. "Low-risk" LEs were performed in the electrophysiology (EP) laboratory with anesthesia provided by EP nursing team. The preintervention (pre-RISE) and postintervention (post-RISE) group spanned 19 and 40 months and consisted of 449 (632 leads) and 751 patients (1055 leads), respectively. The primary outcome of MACEs in the two groups was compared. RESULTS: Protocol compliance was 100%. The primary outcome of MACEs occurred in 15 patients (3.34%) before and 12 (1.6%) after implementation of the RISE protocol (P = .04). CONCLUSION: RISE identified a low-risk group where minimal resources are needed and allowed for rapid intervention in the high-risk group that reduced the consequences of MACEs.


Assuntos
Protocolos Clínicos , Desfibriladores Implantáveis , Remoção de Dispositivo/efeitos adversos , Marca-Passo Artificial , Complicações Pós-Operatórias/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Remoção de Dispositivo/mortalidade , Feminino , Hospitais com Alto Volume de Atendimentos , Humanos , Masculino , Pessoa de Meia-Idade , Ohio , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Desenho de Prótese , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
Europace ; 21(11): 1686-1693, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31681964

RESUMO

AIMS: Patient selection is a key component of securing optimal patient outcomes with leadless pacing. We sought to describe and compare patient characteristics and outcomes of Micra patients with and without a primary pacing indication associated with atrial fibrillation (AF) in the Micra IDE trial. METHODS AND RESULTS: The primary outcome (risk of cardiac failure, pacemaker syndrome, or syncope related to the Micra system or procedure) was compared between successfully implanted patients from the Micra IDE trial with a primary pacing indication associated with AF or history of AF (AF group) and those without (non-AF group). Among 720 patients successfully implanted with Micra, 228 (31.7%) were in the non-AF group. Reasons for selecting VVI pacing in non-AF patients included an expectation for infrequent pacing (66.2%) and advanced age (27.2%). More patients in the non-AF group had a condition that precluded the use of a transvenous pacemaker (9.6% vs. 4.7%, P = 0.013). Atrial fibrillation patients programmed to VVI received significantly more ventricular pacing compared to non-AF patients (median 67.8% vs. 12.6%; P < 0.001). The overall occurrence of the composite outcome at 24 months was 1.8% with no difference between the AF and non-AF groups (hazard ratio 1.36, 95% confidence interval 0.45-4.2; P = 0.59). CONCLUSION: Nearly one-third of patients selected to receive Micra VVI therapy were for indications not associated with AF. Non-AF VVI patients required less frequent pacing compared to patients with AF. Risks associated with VVI therapy were low and did not differ in those with and without AF.


Assuntos
Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial/métodos , Ventrículos do Coração/fisiopatologia , Marca-Passo Artificial , Seleção de Pacientes , Idoso , Fibrilação Atrial/fisiopatologia , Desenho de Equipamento , Feminino , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
12.
Pacing Clin Electrophysiol ; 42(1): 58-62, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30414285

RESUMO

BACKGROUND: Lead dislodgement (LD) is a well-recognized complication during implantation of cardiac implantable electronic devices (CIEDs). An intraprocedural protocol, referred to as reduction of LD protocol, was developed to reduce the risk of LD. METHODS: The protocol involved (1) inserting a straight stylet down the right atrial lead and applying forward pressure while monitoring for fluoroscopic stability, (2) visualizing all leads during deep inspiration to determine if there is adequate lead redundancy, and (3) having the patient take a deep breath and cough while pacing just at capture threshold to assess for loss of capture in each lead. Any intraprocedural change in the parameters fulfilling the predefined criteria for inadequate lead implantation prompted lead repositioning. Data regarding demographic factors, clinical characteristics, and incidence of LD in the first 30 days after implant was obtained from intramural CIED database. The preintervention (control) group spanned 27 months and consisted of a total of 4,294 leads while the postintervention (intervention) group spanned 17 months and consisted of 2,361 leads implanted. RESULTS: There was no significant difference in the demographic factors and clinical characteristics in the two groups. Protocol compliance was > 90%. There were 44 occurrences of LD (1.02%) before and 10 (0.4%) after implementation of the protocol. The protocol significantly reduced the incidence of LD during the 30 days after implant (P = 0.014). No clinical characteristic predicted the risk of LD. CONCLUSION: Intraprocedural maneuvers performed to assess the adequacy of lead implantation results in reduced risk of LD.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Falha de Equipamento , Complicações Pós-Operatórias/prevenção & controle , Idoso , Eletrocardiografia , Feminino , Fluoroscopia , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco
13.
Pacing Clin Electrophysiol ; 42(12): 1552-1557, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31702059

RESUMO

BACKGROUND: The perioperative anesthesia care during subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is still evolving. OBJECTIVE: To assess the feasibility and safety of S-ICD implantation with monitored anesthesia care (MAC) versus general anesthesia (GA) in a tertiary care center. METHODS: This is a single-center retrospective study of patients undergoing S-ICD implantation between October 2012 and May 2019. Patients were categorized into MAC and GA group based on the mode of anesthesia. Procedural success without escalation to GA was the primary endpoint of the study, whereas intraprocedural hemodynamics, need of pharmacological support for hypotension and bradycardia, length of the procedure, stay in the post-anesthesia care unit, and postoperative pain were assessed as secondary endpoints. RESULTS: The study comprises 287 patients with MAC in 111 and GA in 176 patients. Compared to MAC, patients in GA group were younger and had a higher body mass index. All patients had successful S-ICD implantation. Only one patient (0.9%) in the MAC group was converted to GA. Despite a similar baseline heart rate (HR) and mean arterial blood pressure (MAP) in both groups, patients with GA had significantly lower HR and MAP during the procedure and more frequently required pharmacological hemodynamic support. Length of the procedure, stay in the postanesthesia care unit, and postoperative pain was similar in both groups. CONCLUSION: This retrospective experience suggests that implantation of S-ICD is feasible and safe with MAC. Use of GA is associated with more frequent administration of hemodynamic drugs during S-ICD implantation.


Assuntos
Anestesia/métodos , Desfibriladores Implantáveis , Implantação de Prótese/métodos , Anestesia Geral , Anestesia Local , Bradicardia/tratamento farmacológico , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Hipotensão/tratamento farmacológico , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Medição da Dor , Dor Pós-Operatória/prevenção & controle , Estudos Retrospectivos
16.
J Cardiovasc Electrophysiol ; 29(10): 1460-1466, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29964312

RESUMO

BACKGROUND: Cardiac implantable electronic device (CIED) infections associated with large, mobile vegetation adds to the complexity of lead extraction and is associated with significant patient morbidity and mortality. OBJECTIVE: To show the feasibility of concomitant cardiovascular implantable electronic device extraction and vacuum-assisted removal of lead-related vegetations. METHODS: This is a single-center retrospective case series of consecutive patients with persistent bacteremia, sepsis, or endocarditis despite medical therapy who have vegetations >2 cm and subsequently underwent immediate CIED lead extraction after debulking with vacuum-assisted suction. RESULTS: Eight patients underwent successful removal of 17 leads immediately after debulking of vegetations with vacuum-assisted device suction. Debulking procedure was not successful in 1 patient due to inability to direct the vacuum suction device into proper position. There were no intraprocedure complications related to the vacuum-assisted debulking. One patient required open sternotomy for tear of the coronary sinus ostium related to extraction of a left ventricular pacing electrode. There was no mortality within 30 days of the procedure. CONCLUSIONS: Based upon these clinical results, it is feasible for patients with infected CIED systems that have large right-sided vegetations to undergo vacuum-assisted debulking then immediately followed by percutaneous CIED removal in whom surgical removal is considered high risk.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos de Citorredução/métodos , Remoção de Dispositivo/métodos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Infecções Relacionadas à Prótese/terapia , Adulto , Idoso , Procedimentos Cirúrgicos de Citorredução/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sucção , Resultado do Tratamento , Vácuo , Adulto Jovem
18.
Pacing Clin Electrophysiol ; 41(11): 1491-1494, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30191582

RESUMO

BACKGROUND: A wearable cardioverter defibrillator (WCD) is an alternative for patients who are not immediate candidates for an implantable cardioverter defibrillator (ICD). METHODS: Retrospective analysis of 242 patients prescribed a WCD from January 2014 through March 2015 with 1-year follow-up. RESULTS: A WCD was prescribed to 242 patients during the 15-month period. Forty-one patients were excluded due to lack of complete follow-up. The remaining 201 patients received a WCD for primary or secondary prevention of SCD. Seventy-nine percent of WCDs were prescribed by nonelectrophysiologists. Underlying etiologies for the WCD prescription included: 38% nonischemic cardiomyopathy, 25% recent myocardial infarction, 16% newly diagnosed ischemic cardiomyopathy, 12% documented ventricular arrhythmia, 6% ICD lead extraction, and 3% had high risk conditions for sudden cardiac death. During 1-year follow-up, 96 patients (48%) received an ICD and five patients (2.5%) received appropriate shocks and one patient (0.5 %) received an inappropriate shock. Other 105 (52%) patients subsequently did not require an ICD due to either improvement in ejection fraction, refusal of ICD therapy, or death. CONCLUSIONS: About half of patients prescribed a WCD subsequently receive an ICD and the rate of appropriate shock therapy from the WCD is 2.5%.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica/instrumentação , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária , Estudos Retrospectivos , Fatores de Risco , Prevenção Secundária , Resultado do Tratamento
19.
Pacing Clin Electrophysiol ; 41(5): 504-510, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29476660

RESUMO

BACKGROUND: Atrioventricular junctional (AVJ) ablation and pacemaker implantation are indicated when pharmacotherapy fails to achieve adequate rate control in atrial fibrillation (AF). The purpose of our study is to assess the feasibility and safety of concurrent Micra leadless transcatheter pacemaker implantation and AVJ ablation. METHODS: We retrospectively assessed patients who underwent Micra implantation and concurrent AVJ ablation at three institutions between August 2014 and March 2016. All patients and devices were followed at baseline and at 1, 3, 6, and 12 months postimplantion. RESULTS: Twenty-one patients with permanent AF (median age 77 [range: 62-88], female 15 [71.4%]) underwent successful Micra implantation followed by concurrent AVJ ablation. There was no device dislodgement or malfunction during the 12-month follow-up. Complete 12-month electrical performance data were available in 14 patients (67%). Among patients with the complete data set, median pacing thresholds at implant and at 1, 3, 6, and 12 months were 0.5 V (range: 0.25-0.88), 0.44 V (range: 0.25-2.0), 0.5 V (range: 0.25-1.63), 0.5 V (range: 0.25-1.13), and 0.5 V (range: 0.25-1.13) at a pulse width of 0.24 msec, respectively. Two patients died due to noncardiac causes during follow-up. There were no patients with major device-related complications. CONCLUSIONS: Concurrent Micra implantation and AVJ ablation is feasible and appears safe. There was no device dislodgement, malfunction, or significant pacing threshold rise requiring device reimplantation during the 12-month follow-up. This combined approach can be considered for patients with AF with suboptimal rate control who have failed AF catheter ablation and/or pharmacotherapy.


Assuntos
Fibrilação Atrial/cirurgia , Nó Atrioventricular/cirurgia , Ablação por Cateter/métodos , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Nó Atrioventricular/fisiopatologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
20.
Proc Natl Acad Sci U S A ; 112(33): 10321-4, 2015 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-26240325

RESUMO

Three times as many cases of measles were reported in the United States in 2014 as in 2013. The reemergence of measles has been linked to a dangerous trend: parents refusing vaccinations for their children. Efforts have been made to counter people's antivaccination attitudes by providing scientific evidence refuting vaccination myths, but these interventions have proven ineffective. This study shows that highlighting factual information about the dangers of communicable diseases can positively impact people's attitudes to vaccination. This method outperformed alternative interventions aimed at undercutting vaccination myths.


Assuntos
Conhecimentos, Atitudes e Prática em Saúde , Programas de Imunização/métodos , Pais/psicologia , Educação de Pacientes como Assunto/métodos , Vacinação/psicologia , Adulto , Centers for Disease Control and Prevention, U.S. , Criança , Feminino , Humanos , Masculino , Sarampo/prevenção & controle , Vacina contra Sarampo , Pessoa de Meia-Idade , Percepção , Risco , Estados Unidos , Vacinação/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA