Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Clin Microbiol ; 55(8): 2462-2471, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28566316

RESUMO

With the emerging Zika virus (ZIKV) epidemic, serologic diagnosis relies on a labor-intensive IgM antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) and confirmation by a plaque reduction neutralization test (PRNT). To streamline serologic testing, several commercial assays have been developed. Our aim was to compare the commercial Euroimmun anti-ZIKV IgM and IgG assays to the reference MAC-ELISA and PRNT currently in use. Serum specimens submitted to Public Health Ontario Laboratory, Canada, were tested for IgM and IgG using the Euroimmun assays and the results were compared with those from MAC-ELISA. The PRNT was performed on positive or equivocal specimens using either MAC-ELISA or Euroimmun assays, MAC-ELISA-inconclusive specimens, and a convenience sample of specimens negative by both assays (cohort 1). Another set of specimens selected on the basis of PRNT results was subsequently tested by the Euroimmun assays (cohort 2). MAC-ELISA was positive, equivocal, negative, and inconclusive in 57/223, 15/223, 147/223, and 4/223 specimens, respectively. Among the 76 specimens that were MAC-ELISA positive, equivocal, or inconclusive, 30 (39.5%) were Euroimmun IgM and/or IgG positive or equivocal. Among the 147 MAC-ELISA-negative specimens, 136 (92.5%) were Euroimmun IgM and IgG negative. The sensitivity of the combined Euroimmun IgM/IgG against the PRNT was 83% (cohort 1) and 92% (cohort 2), whereas the specificity was 81% (cohort 1) and 65% (cohort 2). The combined Euroimmun IgM/IgG showed good specificity (92.5%) but suboptimal sensitivity (39.5%) compared with that of the MAC-ELISA. However, the sensitivity of the combined Euroimmun IgM/IgG against the PRNT was significantly higher (83 to 92%). More studies are needed before commercial assays are implemented for routine ZIKV serologic diagnosis.


Assuntos
Anticorpos Antivirais/sangue , Ensaio de Imunoadsorção Enzimática/métodos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Testes Sorológicos/métodos , Infecção por Zika virus/diagnóstico , Zika virus/imunologia , Adulto , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ontário , Gravidez , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA