Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Gynecol Obstet Invest ; 85(3): 252-258, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32268326

RESUMO

BACKGROUND/OBJECTIVES: Mechanical micro-vibration remains insufficient for improving embryo culture conditions in human immature oocytes. This study compared the clinical outcomes and embryo development between germinal vesicle (GV) oocytes with the micro-vibration culture (MVC) system in in vitro maturation (IVM) cycles and in vivo-matured oocytes in controlled ovarian hyperstimulation (COH) cycles in polycystic ovarian syndrome (PCOS) patients. METHODS: This study investigated 152 PCOS patients who underwent 159 fresh embryo transfer cycles, including IVM cycles with embryos derived from GV oocytes and the COH cycles with embryos derived from in vivo-matured oocytes. The IVM cycles were divided into groups according to the culture system used: static culture (SC) and MVC: In the IVM-S group (n = 47), SC was applied during both IVM and in vitro culture (IVC), whereas in the IVM-MV group (n = 44), MVC was applied during both IVM and IVC. For the COH cycles, in the COH-S group (n = 68), SC was applied during IVC. RESULTS: The number of in vitro-matured oocytes was similar in the IVM-S and IVM-MV groups, but the good-quality embryo (GQE; ≥6-cells) rate was significantly higher in the IVM-MV group (p < 0.01). The GQE rate and clinical outcomes of the COH-S group were significantly better than those of the IVM-S group (p < 0.05) but similar to those of the IVM-MV group. CONCLUSION: Compared with the SC system, the MVC system in IVM cycles improves the embryonic quality of GV oocytes and clinical outcomes, resulting in development of potential equivalent to in vivo-matured oocytes.


Assuntos
Desenvolvimento Embrionário/fisiologia , Técnicas de Maturação in Vitro de Oócitos/métodos , Oócitos/fisiologia , Indução da Ovulação/métodos , Síndrome do Ovário Policístico/fisiopatologia , Adulto , Transferência Embrionária , Feminino , Humanos , Gravidez , Resultado do Tratamento , Vibração
2.
J Assist Reprod Genet ; 32(1): 155-68, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25358408

RESUMO

PURPOSE: In the field of assisted reproductive technology (ART), medical accidents can result in serious legal and social consequences. This study was conducted to develop a security system (called IVF-guardian; IG) that could prevent mismatching or mix-ups in ART. MATERIALS AND METHODS: A software program was developed in collaboration with outside computer programmers. A quick response (QR) code was used to identify the patients, gametes and embryos in a format that was printed on a label. There was a possibility that embryo development could be affected by volatile organic components (VOC) in the printing material and adhesive material in the label paper. Further, LED light was used as the light source to recognize the QR code. Using mouse embryos, the effects of the label paper and LED light were examined. The stability of IG was assessed when applied in clinical practice after developing the system. A total of 104 cycles formed the study group, and 82 cycles (from patients who did not want to use IG because of safety concerns and lack of confidence in the security system) to which IG was not applied comprised the control group. RESULTS: Many of the label paper samples were toxic to mouse embryo development. We selected a particular label paper (P touch label) that did not affect mouse embryo development. The LED lights were non-toxic to the development of the mouse embryos under any experimental conditions. There were no differences in the clinical pregnancy rates between the IG-applied group and the control group (40/104 = 38.5 % and 30/82 = 36.6 %, respectively). CONCLUSIONS: The application of IG in clinical practice did not affect human embryo development or clinical outcomes. The use of IG reduces the misspelling of patient names. Using IG, there was a disadvantage in that each treatment step became more complicated, but the medical staff improved and became sufficiently confident in ART to offset this disadvantage. Patients who received treatment using the IG system also went through a somewhat tedious process, but there were no complaints. These patients gained further confidence in the practitioners over the course of treatment.


Assuntos
Técnicas de Reprodução Assistida , Segurança , Software , Animais , Feminino , Células Germinativas/fisiologia , Humanos , Camundongos , Gravidez , Taxa de Gravidez
3.
J Assist Reprod Genet ; 30(6): 835-41, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23657828

RESUMO

PURPOSE: Micro-vibration culture system was examined to determine the effects on mouse and human embryo development and possible improvement of clinical outcomes in poor responders. MATERIALS AND METHODS: The embryonic development rates and cell numbers of blastocysts were compared between a static culture group (n = 178) and a micro-vibration culture group (n = 181) in mice. The embryonic development rates and clinical results were compared between a static culture group (n = 159 cycles) and a micro-vibration culture group (n = 166 cycles) in poor responders. A micro-vibrator was set at a frequency of 42 Hz, 5 s/60 min duration for mouse and human embryo development. RESULTS: The embryonic development rate was significantly improved in the micro-vibration culture group in mice (p < 0.05). The cell numbers of mouse blastocysts were significantly higher in the micro-vibration group than in the static culture group (p < 0.05). In the poor responders, the rate of high grade embryos was not significantly improved in the micro-vibration culture group on day 3. However, the optimal embryonic development rate on day 5 was improved in the micro-vibration group, and the total pregnancy rate and implantation rate were significantly higher in the micro-vibration group than in the static culture group (p < 0.05). CONCLUSIONS: Micro-vibration culture methods have a beneficial effect on embryonic development in mouse embryos. In poor responders, the embryo development rate was improved to a limited extent under the micro-vibration culture conditions, but the clinical results were significantly improved.


Assuntos
Blastocisto/citologia , Técnicas de Cultura Embrionária/métodos , Desenvolvimento Embrionário , Vibração , Adulto , Animais , Meios de Cultura , Implantação do Embrião , Transferência Embrionária , Feminino , Humanos , Camundongos , Indução da Ovulação , Gravidez , Taxa de Gravidez
4.
Clin Exp Reprod Med ; 45(1): 52-55, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29662827

RESUMO

This study retrospectively assessed whether time-lapse data relating to developmental timing and morphology were associated with clinical outcomes, with the eventual goal of using morphokinetic variables to select embryos prospectively for cryopreservation. In this study, we examined the clinical outcomes of single vitrified-warmed blastocyst transfer cycles that were cultured in a time-lapse incubation system. The morphokinetic variables included uneven pronuclei, an uneven blastomere, multinucleation, and direct, rapid, and irregular division. A total of 164 single vitrified-warmed blastocyst transfer cycles were analyzed (102 cycles of regularly developed blastocysts and 62 cycles of blastocysts with morphokinetic variables). No significant differences in the age of females or the standard blastocyst morphology were found between these two groups. The regularly developed blastocysts showed significantly higher implantation and clinical pregnancy rates than the blastocysts exhibiting morphokinetic variables (30.4% vs. 9.7% and 37.3% vs. 14.5%, respectively; p<0.01). The blastocysts that exhibited morphokinetic variables showed different mean development times compared with the regularly developed blastocysts. Although morphokinetic variables are known to have fatal impacts on embryonic development, a considerable number of embryos developed to the blastocyst stage. Morphokinetic variables had negative effects on the implantation and clinical pregnancy rates in vitrified-warmed blastocyst transfer cycles. These findings suggest that blastocysts cultured in a time-lapse incubation system should be considered for selective cryopreservation according to morphokinetic variables.

5.
Clin Exp Reprod Med ; 43(2): 106-11, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27358829

RESUMO

OBJECTIVE: To study the clinical outcomes of single frozen-thawed blastocyst transfer cycles according to the hatching status of frozen-thawed blastocysts. METHODS: Frozen-thawed blastocysts were divided into three groups according to their hatching status as follows: less-than-expanded blastocyst (≤EdB), hatching blastocyst (HgB), and hatched blastocyst (HdB). The female age and infertility factors of each group were evaluated. The quality of the single frozen-thawed blastocyst was also graded as grade A, tightly packed inner cell mass (ICM) and many cells organized in the trophectoderm epithelium (TE); grade B, several and loose ICM and TE; and grade C, very few ICM and a few cells in the TE. The clinical pregnancy and implantation rate were compared between each group. The data were analyzed by either t-test or chi-square analysis. RESULTS: There were no statistically significant differences in average female ages, infertility factors, or the distribution of blastocyst grades A, B, and C in each group. There was no significant difference in the clinical pregnancy and implantation rate of each group according to their blastocyst grade. However, there was a significant difference in the clinical pregnancy and implantation rate between each group. In the HdB group, the clinical pregnancy and implantation rate were similar regardless of the blastocyst quality. CONCLUSION: There was an effect on the clinical outcomes depending on whether the blastocyst hatched during single frozen-thawed blastocyst transfer. When performing single frozen-thawed blastocyst transfer, the hatching status of the frozen-thawed blastocyst may be a more important parameter for clinical outcomes than the quality of the frozen-thawed blastocyst.

6.
Clin Exp Reprod Med ; 43(3): 146-51, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27689036

RESUMO

OBJECTIVE: This study was conducted to compare the effects of static culture, dynamic culture, and the combination of dynamic culture with specialized surfaces involving co-culture on human embryonic development. Embryos cultured using conventional static culture (SC) techniques served as a control group. We compared dynamic culture using micro-vibration culture (MVC) and micro-vibration with co-culture (MCoC), in which autologous cumulus cells were used as a specialized surface. METHODS: We conducted a chart review of patients who were treated between January 2011 and November 2014 in order to compare embryonic development rates and pregnancy rates among the groups. Zygotes were cultured in micro-droplets, and embryos were subsequently selected for transfer. Some surplus embryos were cryopreserved, and the others were cultured for blastocyst development. A micro-vibrator was set at the frequency of 42 Hz for duration of 5 seconds per 60 minutes to facilitate embryo development. RESULTS: No significant differences among the groups were present in patient's characteristics. However, the clinical pregnancy rates were significantly higher in the MVC group and the MCoC group than in the SC group. No significant differences were found in the blastocyst development rate between the SC group and the MVC group, but the blastocyst development rate in the MCoC group was significantly higher than in the SC and MVC groups. CONCLUSION: The clinical pregnancy rate was significantly increased by the application of micro-vibration to the embryonic cultures of poor responders. The blastocyst development rate was significantly increased by the application of MCoC to surplus embryos.

7.
Clin Exp Reprod Med ; 39(4): 153-60, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23346525

RESUMO

OBJECTIVE: The aim of this study was to compare vitrification optimization of mouse embryos using electron microscopy (EM) grid, cryotop, and thin plastic strip (TPS) containers by evaluating developmental competence and apoptosis rates. METHODS: Mouse embryos were obtained from superovulated mice. Mouse cleavage-stage, expanded, hatching-stage, and hatched-stage embryos were cryopreserved in EM grid, cryotop, and TPS containers by vitrification in 15% ethylene glycol, 15% dimethylsulfoxide, 10 µg/mL Ficoll, and 0.65 M sucrose, and 20% serum substitute supplement (SSS) with basal medium, respectively. For the three groups in which the embryos were thawed in the EM grid, cryotop, and TPS containers, the thawing solution consisted of 0.25 M sucrose, 0.125 M sucrose, and 20% SSS with basal medium, respectively. Rates of survival, re-expansion, reaching the hatched stage, and apoptosis after thawing were compared among the three groups. RESULTS: Developmental competence after thawing of vitrified expanded and hatching-stage blastocysts using cryotop and TPS methods were significantly higher than survival using the EM grid (p<0.05). Also, apoptosis positive nuclei rates after thawing of vitrified expanded blastocysts using cryotop and TPS were significantly lower than when using the EM grid (p<0.05). CONCLUSION: The TPS vitrification method has the advantages of achieving a high developmental ability and effective preservation.

8.
Clin Exp Reprod Med ; 38(2): 87-92, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22384424

RESUMO

OBJECTIVE: This study aimed to determine the safety and clinical effect of artificial shrinkage (AS) in terms of assisted hatching of fresh blastocysts. Also, we evaluated the correlation between patient age and the effect of AS on clinical outcome. METHODS: Two AS methods, using a 29-gauge needle and laser pulse, were compared. Seventy-three blastocysts were shrunk using a 29-gauge needle and the same number of other blastocysts were shrunk by a laser pulse. We evaluated the shrunken blastocysts hourly and considered them viable if they re-expanded >70%. Blastocyst transfer cycles (n=134) were divided into two groups: a control group consisted of the cycles whose intact embryos were transferred (n=100), while the AS group consisted of the cycles whose embryos were replaced following AS (n=34). The implantation and pregnancy rates of the control group and AS group were compared (p<0.05). RESULTS: The re-expansion rates of the 29-gauge needle and laser pulse AS groups were similar (56 [76.7%] vs. 62 [84.9%], respectively). All of the remaining shrunken blastocysts were re-expanded within 2 hours. There was no degeneration of shrunken blastocysts. The total and clinical pregnancy rate of the AS group (23 [67.6%]; 20 [58.8%], respectively) was significantly higher than that of the control group (47 [47.0%]; 39 [39.0%], respectively). In the older patient group, there was no difference in the clinical outcomes between the AS and control groups. CONCLUSION: These results suggest that AS of blastocoele cavity, followed by the transfer, would be a useful approach to improve the clinical outcome in cycles in which fresh blastocyst stage embryos are transferred.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA