Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 178
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38092064

RESUMO

BACKGROUND: This study was conducted to evaluate whether myocardial viability assessed with cardiac magnetic resonance (CMR) affected long-term clinical outcomes after coronary artery bypass grafting (CABG) in patients with ischemic cardiomyopathy (ICMP). METHODS: Preoperative CMR with late gadolinium enhancement (LGE) was performed in 103 patients (64.9 ± 10.1 years, male:female = 82:21) with 3-vessel disease and left ventricular dysfunction (ejection fraction ≤ 0.35). Transmural extent of LGE was evaluated on a 16-segment model, and transmurality was graded on a 5-point scale: grades-0, absence; 1, 1 to 25%; 2, 26 to 50%; 3, 51 to 75%; 4, 76 to 100%. Median follow-up duration was 65.5 months (interquartile range = 27.5-95.3 months). Primary endpoint was the composite of all-cause mortality or hospitalization for congestive heart failure. RESULTS: Operative mortality was 1.9%. During the follow-up, all-cause mortality and readmission for congestive heart failure occurred in 29 and 8 patients, respectively. The cumulative incidence of the primary endpoint was 31.3 and 46.8% at 5 and 10 years, respectively. Multivariable analysis demonstrated that the number of segments with LGE grade 4 was a significant risk factor (hazard ratio 1.42, 95% confidence interval 1.10-1.83, p = 0.007) for the primary endpoint among the variables assessed by CMR. Other risk factors included age, dialysis, chronic obstructive pulmonary disease, and EuroSCORE II. CONCLUSION: The number of myocardial segments with transmurality of LGE >75% might be a prognostic factor associated with the composite of all-cause mortality or hospitalization for congestive heart failure after CABG in patients with 3-vessel disease and ICMP.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38442916

RESUMO

BACKGROUND: As redo surgical aortic valve replacement (AVR) is relatively high risk, valve-in-valve transcatheter AVR has emerged as an alternative for failed prostheses. However, the majority of studies are outdated. This study assessed the current clinical outcomes of redo AVR. METHODS AND RESULTS: This study enrolled 324 patients who underwent redo AVR due to prosthetic valve failure from 2010 to 2021 in four tertiary centers. The primary outcome was operative mortality. The secondary outcomes were overall survival, cardiac death, and aortic valve-related events. Logistic regression analysis, clustered Cox proportional hazards models, and competing risk analysis were used to evaluate the independent risk factors. Redo AVR was performed in 242 patients without endocarditis and 82 patients with endocarditis. Overall operative mortality was 4.6% (15 deaths). Excluding patients with endocarditis, the operative mortality of redo AVR decreased to 2.5%. Multivariate analyses demonstrated that endocarditis (hazard ratio [HR]: 3.990, p = 0.014), longer cardiopulmonary bypass time (HR: 1.006, p = 0.037), and lower left ventricular ejection fraction (LVEF) (HR: 0.956, p = 0.034) were risk factors of operative mortality. Endocarditis and lower LVEF were independent predictors of overall survival. CONCLUSION: The relatively high risk of redo AVR was due to reoperation for prosthetic valve endocarditis. The outcomes of redo AVR for nonendocarditis are excellent. Our findings suggest that patients without endocarditis, especially with acceptable LVEF, can be treated safely with redo AVR.

3.
J Korean Med Sci ; 39(7): e79, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38412613

RESUMO

BACKGROUND: This study evaluated the difference in brain metabolite profiles between normothermia and hypothermia reaching 25°C in humans in vivo. METHODS: Thirteen patients who underwent thoracic aorta surgery under moderate hypothermia were prospectively enrolled. Plasma samples were collected simultaneously from the arteries and veins to estimate metabolite uptake or release. Targeted metabolomics based on liquid chromatographic mass spectrometry and direct flow injection were performed, and changes in the profiles of respective metabolites from normothermia to hypothermia were compared. The ratios of metabolite concentrations in venous blood samples to those in arterial blood samples (V/A ratios) were calculated, and log2 transformation of the ratios [log2(V/A)] was performed for comparison between the temperature groups. RESULTS: Targeted metabolomics were performed for 140 metabolites, including 20 amino acids, 13 biogenic amines, 10 acylcarnitines, 82 glycerophospholipids, 14 sphingomyelins, and 1 hexose. Of the 140 metabolites analyzed, 137 metabolites were released from the brain in normothermia, and the release of 132 of these 137 metabolites was decreased in hypothermia. Two metabolites (dopamine and hexose) showed constant release from the brain in hypothermia, and 3 metabolites (2 glycophospholipids and 1 sphingomyelin) showed conversion from release to uptake in hypothermia. Glutamic acid demonstrated a distinct brain metabolism in that it was taken up by the brain in normothermia, and the uptake was increased in hypothermia. CONCLUSION: Targeted metabolomics demonstrated various degrees of changes in the release of metabolites by the hypothermic brain. The release of most metabolites was decreased in hypothermia, whereas glutamic acid showed a distinct brain metabolism.


Assuntos
Hipotermia Induzida , Hipotermia , Humanos , Hipotermia/metabolismo , Encéfalo/metabolismo , Aminoácidos , Hipotermia Induzida/métodos , Hexoses/metabolismo , Glutamatos/metabolismo
4.
Thorac Cardiovasc Surg ; 71(8): 648-655, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-35917824

RESUMO

BACKGROUND: A randomized controlled trial was designed to compare 1-year hemodynamic profiles and clinical outcomes after bioprosthetic aortic valve replacement (AVR) using a recently introduced (study group) and world-widely used (control group) bovine pericardial bioprostheses. This study evaluated early postoperative outcomes as a preliminary analysis. METHODS: The primary end point of the trial was the mean pressure gradient across the aortic valve (AVMPG) at 1 year after surgery. Patients were screened to enroll 70 patients in each group based on a noninferiority design. Early postoperative hemodynamic and clinical outcomes were compared between the two groups. RESULTS: There were no differences in baseline characteristics, including sex and body surface area (1.64 ± 0.18 vs. 1.65 ± 0.15 m2) between the two groups. The AVMPG on early postoperative echocardiography was 15.2 ± 4.6 mm Hg and 16.5 ± 6.2 mm Hg in the study and control groups, respectively (p = 0.177). Although AVMPG of the 19 mm prostheses was lower in the study group than in the control group (17.0 ± 6.3 mm Hg vs. 22.8 ± 6.6 mm Hg, p = 0.039), there were no significant differences in the effective orifice area in all patients (1.57 ± 0.41 cm2 vs. 1.53 ± 0.34 cm2, p = 0.568), and each valve size. The effective orifice area index was also similar between the two groups in overall (p = 0.352), and in each valve size. There were no significant differences in clinical outcomes including operative mortality and postoperative complications between the two groups. CONCLUSION: Early postoperative hemodynamic and clinical results after AVR using a recently introduced bovine pericardial valve were comparable with those using the control valve (NCT03796442).


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Animais , Bovinos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Hemodinâmica
5.
Artigo em Inglês | MEDLINE | ID: mdl-36948215

RESUMO

BACKGROUND: This study aimed to compare long-term outcomes after tricuspid valve (TV) repair (TVr) with those after TV replacement (TVR) by adjusting the right ventricular (RV) volume and function. METHODS: We enrolled 147 patients who underwent TVr (n = 78) and TVR (n = 69) for grade 3 or 4 tricuspid regurgitation and had preoperative cardiac magnetic resonance data. Long-term clinical outcomes were compared between the two groups using inverse probability treatment weighting (IPTW) to adjust for differences in preoperative characteristics between the two groups. Subgroup analyses were performed in patients with preserved and dysfunctional RV (ejection fraction < 50%). RESULTS: There were no significant differences in operative mortality or postoperative complications between the two groups before and after the IPTW adjustment. Five- and 10-year overall survival rates were 84.2 and 67.1%, respectively. Five- and 10-year cumulative incidences of TV-related events (TVREs) were 33.1 and 55.6%, respectively. There were no significant differences in overall survival and cumulative incidence of TVREs after IPTW adjustment (p = 0.236 and p = 0.989, respectively). The risk-adjusted overall survival was marginally higher in the TVr group of patients with preserved RV function (p = 0.054), while no such significant difference was found between the two groups of patients with dysfunctional RV (p = 0.513). CONCLUSION: Adjusted long-term clinical outcomes after TVr and TVR were comparable. TVr might be beneficial for patients with preserved RV function in terms of long-term survival; however, this benefit might disappear in patients with RV dysfunction.

6.
Artigo em Inglês | MEDLINE | ID: mdl-37884030

RESUMO

BACKGROUND: This randomized controlled trial was designed to compare 1-year hemodynamic performances and clinical outcomes after aortic valve replacement (AVR) using a recently introduced (the AVALUS group) and worldwide used (the CEPME group) bovine pericardial bioprostheses. METHODS: Patients were screened to enroll 70 patients in each group based on a noninferiority design. The primary endpoint of the trial was the mean pressure gradient across the aortic valve (AVMPG) at 1 year after surgery. One-year echocardiographic data were obtained from 92.1% (129 of 140 patients) of the study patients. RESULTS: There were no differences in baseline characteristics, including sex and body surface area (1.64 ± 0.18 vs. 1.65 ± 0.15 m2) between the groups. The AVMPG on 1-year echocardiography was 14.0 ± 4.3 and 13.9 ± 5.1 mmHg in the AVALUS and CEPME groups, respectively (the p-value for noninferiority was 0.0004). In the subgroup analyses for the respective size of the prostheses, AVMPG of the 19-mm prostheses was significantly lower in the AVALUS group than in the CEPME group (14.0 ± 4.3 vs. 20.0 ± 4.7 mmHg, p = 0.012), whereas those of the other sizes were not significantly different between the two groups. There were no significant differences in the effective orifice area (1.49 ± 0.40 vs. 1.53 ± 0.38 cm2, p = 0.500) or effective orifice area index (0.91 ± 0.22 vs 0.93 ± 0.23 cm2/m2, p = 0.570) in all the patients, or in the subgroup analysis for the 19-mm prosthesis. There were no differences in the 1-year clinical outcomes between the two groups. CONCLUSION: The 1-year hemodynamic and clinical outcomes of the AVALUS group were noninferior to those of the CEPME group (NCT03796442).

7.
Thorac Cardiovasc Surg ; 70(3): 182-188, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33940657

RESUMO

BACKGROUND: This study was conducted to evaluate the occurrence rate and risk factors of subaortic pannus (SAP) after bileaflet mechanical aortic valve (AV) replacement. METHODS: Between 1990 and 2014, 862 patients underwent primary AV replacement with bileaflet mechanical prosthesis. SAP was defined as (1) gradual increase in mean pressure gradient through mechanical AV without any evidence of motion limitation of the leaflets on echocardiography and (2) AV mean pressure gradient >40 mm Hg or AV peak velocity >4 m/s on echocardiography, and (3) any visible subaortic tissue ingrowth beneath the mechanical AV on echocardiography or computed tomography. Clinical and echocardiographic follow-up durations were 13.8 ± 8.0 and 10.7 ± 7.9 years, respectively. RESULTS: Mean age was 51.1 ± 12.1 years and concomitant surgeries were performed in 503 patients (58.4%). Overall survival at 10 and 20 years was 84.2 and 67.1%, respectively. SAP occurred in 33 patients, and in only 2 patients during the first 10 years after surgery. The cumulative incidence of SAP formation at 10, 20, and 25 years were 0.3, 5.0, and 9.9%, respectively. The Fine and Gray model demonstrated that small prosthetic valve size (hazard ratio [HR] [95% confidence interval, CI] = 0.738 [0.575-0.946]), young age (HR [95% CI] = 0.944 [0.909-0.981]), and concomitant mitral valve replacement (MVR) (HR [95% CI] = 3.863 [1.358-10.988]) were significant risk factors for the SAP formation. CONCLUSIONS: SAP occurred gradually over time with 10- and 20-year cumulative incidence of 0.3 and 5.0%, respectively. Young age, small prosthetic valve size, and concomitant MVR were risk factors for SAP formation. Therefore, we recommend efforts to select large prostheses for young patients requiring concomitant MVR.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Incidência , Pessoa de Meia-Idade , Pannus , Desenho de Prótese , Reoperação , Fatores de Risco , Resultado do Tratamento
8.
Circ J ; 85(7): 1042-1049, 2021 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-34053969

RESUMO

BACKGROUND: This study evaluated the long-term outcomes for up to 20 years after On-X mechanical valve implantation in the left side of the heart.Methods and Results:Between 1999 and 2015, 861 patients (mean age=51.6±10.9 years) who underwent prosthetic valve replacement using the On-X valve in the aortic or mitral position were enrolled (aortic=344, mitral=325, double=192). The mean clinical follow-up duration was 10.5±5.3 (median 10.9) years. Operative mortality occurred in 26 patients (3.0%), and linearized late cardiac mortality was 0.9%/patient-year without an intergroup difference. Linearized thromboembolism, bleeding, prosthetic valve endocarditis, non-structural valve deterioration (NSVD), and reoperation rates were 0.8%/patient-year, 0.6%/patient-year, 0.2%/patient-year, 0.5%/patient-year, and 0.5%/patient-year, respectively. Prosthetic valve endocarditis was more frequent after double valve replacement than after aortic or mitral valve replacement (P=0.008 and 0.005, respectively). NSVD and reoperation rates were significantly lower aortic valve replacement than after mitral or double valve replacement (P=0.001 and 0.002, P=0.001 and <0.001, respectively). Valve replacement in the mitral position was the only risk factor for NSVD (hazard ratio [95% confidence interval]=5.247 [1.608-17.116], P=0.006). CONCLUSIONS: On-X valve implantation in the left side heart had favorable clinical outcomes with acceptable early and late mortality and a low incidence of prosthetic valve-related complications. Particularly in the aortic position, the On-X valve had better long-term non-structural durability.


Assuntos
Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Adulto , Valva Aórtica/cirurgia , Endocardite/etiologia , Endocardite/cirurgia , Endocardite Bacteriana , Seguimentos , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Reoperação
9.
Artif Organs ; 45(8): 911-918, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33432612

RESUMO

This study was conducted to compare the occurrence and the risk factors of structural valve deterioration (SVD) after bioprosthetic tricuspid valve replacement (TVR) between bovine pericardial valves and porcine valves. One-hundred and thirty-four TVR patients were enrolled; 108 patients underwent TVR with bovine pericardial bioprostheses (BTVR group) and 26 underwent TVR with porcine bioprostheses (PTVR group). The early results and long-term clinical outcomes were compared. The median follow-up duration was 90 (interquartile range: 33-135) months. Propensity score (PS) adjusted Cox regression and competing risk analyses were performed. The mean ages of the BTVR and PTVR groups were 62.2 ± 10.7 and 57.3 ± 13.9 years, respectively. The overall survival and cumulative incidence of cardiac death in the BTVR group were similar to those in the PTVR group (hazard ratio [95% confidence interval] = 1.399 [0.500-3.922] and 0.742 [0.249-2.212], respectively). SVD was significantly more frequent in the BTVR group (17.544 [1.070-243.902], P = .045). The tricuspid valve reoperation rate was significantly higher in the BTVR group (38.462 [2.591-476.190], P = .008). The cumulative incidence of SVD after bioprosthetic TVR was higher when using bovine pericardial valves than when using porcine valves.


Assuntos
Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Falha de Prótese , Valva Tricúspide/cirurgia , Animais , Bovinos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Suínos
10.
Thorac Cardiovasc Surg ; 69(2): 133-140, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32252112

RESUMO

BACKGROUND: This meta-analysis was conducted to evaluate the impact of perioperative use of beta-blocker (BB) on postoperative atrial fibrillation (POAF) after cardiac surgery other than isolated coronary artery bypass grafting (CABG). METHODS: Five online databases were searched. Studies were included if they (1) enrolled patients who underwent cardiac surgery other than isolated CABG and (2) demonstrated the impact of perioperative use of BB on POAF based on the randomized controlled trial or adjusted analysis. The primary outcome was the occurrence rates of POAF after cardiac surgery. A meta-regression and subgroup analysis were performed according to the proportion of patients with cardiac surgery other than isolated CABG and the timing of BB use, respectively. RESULTS: Thirteen articles (5 randomized and 8 nonrandomized studies: n = 25,496) were selected. Proportion of enrolled patients undergoing cardiac surgery other than isolated CABG ranged from 7 to 100%. The BBs were used in preoperative, postoperative, and both periods in 5, 5, and 3 studies, respectively. The pooled analyses showed that the risk of POAF was significantly lower in patients with perioperative BB than those without (odds ratio, 95% confidence interval = 0.56, 0.35-0.91 and 0.70, 0.55-0.91 in randomized and nonrandomized studies, respectively). The risk of POAF was lower in the BB group irrespective of the proportion of nonisolated CABG. Benefit regarding in-hospital mortality was inconclusive. Perioperative stroke and length of stay were not significantly different between BB and non-BB groups. CONCLUSIONS: Perioperative use of BB is effective in preventing POAF even in patients undergoing cardiac surgery other than isolated CABG, although it did not translate into improved clinical outcomes.


Assuntos
Antagonistas Adrenérgicos beta/administração & dosagem , Antiarrítmicos/administração & dosagem , Fibrilação Atrial/prevenção & controle , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Frequência Cardíaca/efeitos dos fármacos , Assistência Perioperatória , Antagonistas Adrenérgicos beta/efeitos adversos , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Esquema de Medicação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Assistência Perioperatória/efeitos adversos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
J Cardiothorac Vasc Anesth ; 35(8): 2377-2384, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33127285

RESUMO

OBJECTIVES: Although postoperative subglottic secretion drainage prevents ventilator-associated pneumonia (VAP) after cardiac surgery, its role during the perioperative period is unclear. For the present study, the effect of subglottic secretion drainage during and after cardiac surgery on postoperative VAP was investigated. DESIGN: Retrospective, single-center, before-and-after study. SETTING: Perioperative care of cardiac surgical patients in a tertiary university hospital. PARTICIPANTS: Adult patients who underwent cardiac surgery from January 2013-December 2018. INTERVENTIONS: Conventional and subglottic suctioning endotracheal tubes were used in the control and intervention groups before and after a change in institutional policy, respectively. In the intervention group, subglottic secretion drainage was performed continuously during surgery and intermittently after surgery. MEASUREMENTS AND MAIN RESULTS: The risk of postoperative VAP, identified by the National Healthcare Safety Network surveillance definition algorithm, was compared by weighted logistic regression. Logistic regression analyses, with propensity score matching and inverse probability weighting, also were performed. A total of 2,576 patients were analyzed (control [n = 2108]; intervention [n = 468]). Postoperative VAP occurred less frequently in the intervention group (1/468 [0.2%]) compared with the control group (30/2,108 [1.4%]). In the multivariate weighted logistic regression analysis, the risk of VAP after cardiac surgery was significantly lower in the intervention group than in the control group (odds ratio 0.29; 95% confidence interval 0.14-0.58). Similar results were obtained in multivariate analyses after propensity score matching (odds ratio 0.04; 95% confidence interval 0.01-0.14) and inverse probability weighting (odds ratio 0.16; 95% confidence interval 0.05-0.42). CONCLUSIONS: Routine perioperative subglottic secretion drainage using subglottic suctioning endotracheal tubes in patients undergoing cardiac surgery was associated with a reduction in the risk of VAP after surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Pneumonia Associada à Ventilação Mecânica , Adulto , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Drenagem , Glote , Humanos , Intubação Intratraqueal , Pneumonia Associada à Ventilação Mecânica/epidemiologia , Pneumonia Associada à Ventilação Mecânica/prevenção & controle , Respiração Artificial , Estudos Retrospectivos , Sucção
12.
J Korean Med Sci ; 36(22): e163, 2021 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-34100566

RESUMO

BACKGROUND: This study aimed to evaluate the performance of the Society of Thoracic Surgeons (STS) risk model and European System for Cardiac Operative Risk Evaluation (EuroSCORE) II for patients undergoing anaortic off-pump coronary artery bypass grafting (OPCAB). METHODS: From January 2010 to June 2017, 1,048 patients (isolated anaortic OPCAB: 1,043, on-pump conversion:5) undergoing isolated anaortic OPCAB were enrolled. The STS risk score and EuroSCORE II were calculated with dedicated online software. Calibration of the models were performed by the risk-adjusted event ratio that was defined as observed events divided by expected events (O/E ratio) and Hosmer-Lemeshow test. The discrimination powers were evaluated by the area under the receiver operating characteristic curve (AUC). RESULTS: Operative mortality occurred in 10 patients (0.95%). The predicted mortality rates by the EuroSCORE II and STS risk model were 2.58 ± 4.15% and 1.72 ± 2.92%, respectively. The O/E ratio of the EuroSCORE II was 0.370 with significant overprediction of operative mortality (confidence interval [CI], 0.157-0.652; P = 0.003). The STS score also overpredicted the operative mortality (O/E ratio, 0.556) with marginal significance (CI, 0.266-1.023; P = 0.052). Permanent stroke occurred in 6 patients (0.53%). The predicted permanent stroke occurrence rate was 1.73 ± 1.48%. The O/E ratio was 0.332 with significant overprediction of permanent stroke (CI, 0.121-0.722; P = 0.011). Regarding discrimination power for the STS risk model, the operative mortality was excellent (AUC, 0.876) and permanent stroke was acceptable (AUC, 0.740). The EuroSCORE II showed good discrimination power (AUC, 0.784). There was a significant difference in discrimination power for mortality between STS and EuroSCORE II risk models (P = 0.007). CONCLUSION: Preexisting risk predicting scoring systems, STS risk model and EuroSCORE II, overpredict the risk of mortality and stroke rate for anaortic OPCAB. These findings suggest the possibility that anaortic OPCAB can lower the operative mortality and occurrence of postoperative stroke than conventional coronary artery bypass grafting.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea/mortalidade , Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/cirurgia , Medição de Risco/métodos , Idoso , Idoso de 80 Anos ou mais , Ponte de Artéria Coronária/métodos , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Doença da Artéria Coronariana/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Acidente Vascular Cerebral/etiologia
13.
J Korean Med Sci ; 36(9): e57, 2021 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-33686809

RESUMO

BACKGROUND: We compared early and 2-year clinical outcomes of sutureless aortic valve replacement (SAVR) with conventional aortic valve replacement (CAVR) in a nationwide study based on claims data. METHODS: From December 2016 to November 2018, 3,173 patients underwent bioprosthetic aortic valve replacements. SAVR and CAVR were performed in 641 and 2,532 patients, respectively. Propensity score-matched analysis was performed in 640 patient pairs. RESULTS: Operative mortality rate was 2.8% without significant differences between the SAVR (3.4%) and CAVR (2.3%) groups (P = 0.324). There were no significant differences in postoperative morbidities between the groups except for permanent pacemaker (PPM) implantation. PPM implantation rate was significantly higher in the SAVR (3.8%) than in the CAVR group (0.9%) (P < 0.001). One- and two-year overall survival was 89.1% and 87.5%, respectively, without significant differences between the groups (SAVR group vs. CAVR grouP = 89.9% and 90.5% vs. 87.2% and 88.7%, respectively; P = 0.475). There were no significant differences in the cumulative incidence of cardiac death, stroke, aortic valve reoperation and infective endocarditis between the groups. Cumulative PPM implantation incidence at 6 months in the CAVR was 1.1%, and no patient required PPM implantation after 6 months. In the SAVR, the cumulative PPM implantation incidence at 0.5, one, and two years was 3.9%, 5.0% and 5.6%, respectively. The cumulative PPM implantation rate was higher in the SAVR group than in the CAVR group (P < 0.001). CONCLUSION: Early and 2-year clinical outcomes between SAVR and CAVR were not different except for a high rate of permanent pacemaker implantation in the SAVR group.


Assuntos
Valvopatia Aórtica/cirurgia , Próteses Valvulares Cardíacas/estatística & dados numéricos , Procedimentos Cirúrgicos sem Sutura/métodos , Idoso , Idoso de 80 Anos ou mais , Valvopatia Aórtica/mortalidade , Bioprótese/estatística & dados numéricos , Bases de Dados Factuais , Feminino , Seguimentos , Humanos , Masculino , Marca-Passo Artificial/estatística & dados numéricos , Complicações Pós-Operatórias , Pontuação de Propensão , República da Coreia , Taxa de Sobrevida , Resultado do Tratamento
14.
Sensors (Basel) ; 20(22)2020 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-33198411

RESUMO

We propose an underwater multi-DATA train protocol with multi-RTS reception and block ACK (BACK) for underwater acoustic sensor networks. Due to long underwater acoustic propagation delay, some RTS frames may not overlap at a sink node, even if the RTS frames were sent to the sink node simultaneously by different sensor nodes. We consider that our underwater sink node can recover these nonoverlapping RTS frames. Since our RTS frame contains ID of the RTS sending node and a timestamp, the sink node calculates the propagation delay between the RTS sending node and the sink node, then broadcasts a CTS frame. Since our CTS frame contains when each RTS sending node can transmit a DATA frame to the sink node, multiple DATA frames transmitted by different sensor nodes can be formed as a train at the sink node. We also propose an underwater BACK protocol which is analogous to our proposed underwater multi-DATA train protocol. We analyze normalized throughput and mean access delay of our proposed protocols and the conventional protocols. The analytical and simulation results show that our analysis is accurate and our proposed protocols outperform the conventional protocols. Our proposed protocol can shorten the delay and increase the throughput via the multi-DATA train, multi-RTS reception, and BACK.

15.
Thorac Cardiovasc Surg ; 67(7): 538-545, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30300904

RESUMO

BACKGROUND: Numerous studies have demonstrated a negative impact of prosthesis-patient mismatch (PPM) on long-term clinical outcomes after aortic valve replacement. However, the impact of PPM after mitral valve replacement (MVR) on clinical outcomes is still controversial. This study was conducted to evaluate the impact of PPM on early and long-term survival after MVR. METHODS: A literature search of five databases was performed. The primary and secondary outcomes were all-cause mortality and early mortality, respectively. Subgroup analyses were performed according to the risk of bias, patients' age, proportion of female patients, and proportion of patients with mechanical MVR. RESULTS: Eleven nonrandomized studies including 8,072 patients were included in this meta-analysis. The overall incidence of PPM was 58.0% (range: 10.4-85.9%). The odds ratio of early mortality in nine studies was not significantly different between the PPM and non-PPM patients (odds ratio: 1.35; 95% confidence interval [CI]: 0.98-1.86). A pooled analysis in 11 studies demonstrated that all-cause mortality after MVR was higher in the PPM than non-PPM patients (hazard ratio [HR]: 1.39; 95% CI: 1.09-1.77). This analysis revealed a moderate to high heterogeneity (I 2 = 69.4%). When pooled analyses were performed in two subgroups according to the proportion of patients with mechanical MVR, there were low heterogeneity in each group. No other subgroup analyses demonstrated a significant difference in the HR of all-cause mortality. Funnel plots and Egger's tests showed no visually and statistically significant publication bias. CONCLUSION: The present meta-analysis indicates that PPM negatively affects long-term survival after MVR.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Valva Mitral/cirurgia , Adulto , Idoso , Feminino , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Desenho de Prótese , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
J Korean Med Sci ; 34(31): e205, 2019 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-31392853

RESUMO

BACKGROUND: This study was conducted to evaluate the prognostic value of the frailty index based on routine laboratory data (FI-L) in elderly patients who underwent surgical aortic valve replacement (SAVR). METHODS: A total of 154 elderly patients (≥ 75 years) (78.7 ± 3.6 years; men:women = 78:76) who underwent aortic valve replacement with stented bioprosthesis between 2001 and 2018 were enrolled. The FI-L was calculated as the proportion of abnormal results out of 32 items based on laboratory tests, pulse rate and blood pressure. The primary outcome was all-cause mortality. Secondary outcomes included operative mortality and aortic valve-related events (AVREs) during follow-up. The predictive values of FI-L for the early and late outcomes were evaluated using logistic regression and Cox proportional hazards models, respectively. The median follow-up duration was 40 months (interquartile, 15-74). RESULTS: The operative mortality rate was 3.9% (n = 6). Late death occurred in 29 patients. The overall survival (OS) rates at 5, 10, and 15 years were 83.3%, 59.0%, and 41.6%, respectively. The AVREs occurred in 28 patients and the freedom rates from AVREs at 5, 10, and 15 years were 79.4%, 72.7%, and 52.9%, respectively. Multivariable analyses demonstrated that FI-L was a significant factor for OS (hazard ratio, 1.075; 95% confidence interval, 1.040-1.111). A minimal P value approach showed that a FI-L of 25% was the best cutoff value to predict OS after SAVR. CONCLUSION: The FI-L is significantly associated with early and long-term outcomes after SAVR in elderly patients. Frailty rather than a patient's age should be considered in the decision-making process for SAVR in elderly patients.


Assuntos
Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Fragilidade/complicações , Fragilidade/diagnóstico , Próteses Valvulares Cardíacas , Implantação de Prótese , Idoso , Tomada de Decisões , Feminino , Seguimentos , Humanos , Masculino , Complicações Pós-Operatórias , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Medição de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
17.
J Korean Med Sci ; 34(13): e104, 2019 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-30950250

RESUMO

BACKGROUND: The left internal thoracic artery (LITA) has been used as the first conduit of choice in coronary artery bypass grafting (CABG) because of excellent long-term patency and outcomes. However, no studies have examined substances other than nitric oxide that could be beneficial for the bypass conduit, native coronary artery or ischemic myocardium. This study was conducted to evaluate differences in metabolic profiles between the LITA and ascending aorta using gas chromatography-time of flight-mass spectrometry (GC-TOF-MS). METHODS: Twenty patients who underwent CABG using the LITA were prospectively enrolled. Plasma samples were collected simultaneously from the LITA and ascending aorta. GC-TOF-MS based untargeted metabolomic analyses were performed and a 2-step volcano plot analysis was used to identify distinguishable markers from two plasma metabolome profiles. Semi-quantitative and quantitative analyses were performed using GC-TOF-MS and enzyme-linked immunosorbent assay, respectively, after selecting target metabolites based on the metabolite set enrichment analysis. RESULTS: Initial volcano plot analysis demonstrated 5 possible markers among 851 peaks detected. The final analysis demonstrated that the L-cysteine peak was significantly higher in the LITA than in the ascending aorta (fold change = 1.86). The concentrations of intermediate metabolites such as L-cysteine, L-methionine and L-cystine in the 'cysteine and methionine metabolism pathway' were significantly higher in the LITA than in the ascending aorta (2.0-, 1.4- and 1.2-fold, respectively). Quantitative analysis showed that the concentration of hydrogen sulfide (H2S) was significantly higher in the LITA. CONCLUSION: The plasma metabolome profiles of the LITA and ascending aorta were different, particularly higher plasma concentrations of L-cysteine and H2S in the LITA.


Assuntos
Aorta/cirurgia , Artéria Torácica Interna/cirurgia , Metaboloma , Idoso , Ponte de Artéria Coronária , Cisteína/sangue , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Masculino , Metionina/sangue , Pessoa de Meia-Idade , Análise de Componente Principal , Sulfitos/sangue
18.
Circ J ; 82(9): 2358-2363, 2018 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-29973430

RESUMO

BACKGROUND: This study aimed to evaluate the long-term results of tricuspid annuloplasty using the MC3 ring for functional tricuspid regurgitation (TR). Methods and Results: Between 2004 and 2014, 249 patients underwent tricuspid ring annuloplasty using the MC3 ring for functional TR (FTR). Main etiologies of FTR were left-sided valvular disease (n=211) and left-to-right shunt (n=34). Based on the interval between the operation and last echocardiographic scan, patients were divided into short-term and long-term follow-up groups. Mean follow-up duration was 84.4±37.1 months. Operative death occurred in 8 patients (3.2%). Predischarge echocardiography showed that both TR grade and systolic pulmonary artery pressure were significantly decreased compared with preoperative values, and these values were sustained during follow-up in both the short-term and long-term follow-up groups. There were no ring-related complications in either the postoperative or follow-up period, except for permanent pacemaker implantation in 2 patients. The freedom from TR ≥moderate and tricuspid valve (TV)-related events at 10 years were 92.1% and 92.8%, respectively. TV annular size was a risk factor for the recurrence of TR ≥moderate (P=0.001), and 42 mm was the cutoff value for predicting the recurrence of TR ≥moderate. CONCLUSIONS: Tricuspid annuloplasty using the MC3 ring for FTR provides satisfactory early results that are sustained during long-term follow-up. Preoperative TV annular size was associated with the recurrence of TR ≥moderate.


Assuntos
Anuloplastia da Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Insuficiência da Valva Tricúspide/cirurgia , Injúria Renal Aguda/etiologia , Adulto , Idoso , Anuloplastia da Valva Cardíaca/mortalidade , Ecocardiografia , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Recidiva , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento
19.
J Korean Med Sci ; 32(12): 2009-2015, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29115084

RESUMO

We evaluated echocardiographic changes of left ventricular (LV) function in coronary artery bypass grafting (CABG) patients with LV dysfunction, and examined cardiac magnetic resonance (CMR) parameters associated with improved LV function. Seventy-seven CABG patients presenting with decreased LV ejection fraction (LVEF, ≤ 35%) and who underwent preoperative gadolinium-enhanced CMR were enrolled. A 16-segment model was used to analyze CMR imaging. A viable myocardial segment was defined as ≤ 50% transmural extent of late gadolinium enhancement. Serial echocardiographic examinations were performed preoperatively, pre-discharge (median 6 days), and during postoperative year 1 (median 11 months) in 70 patients. Predictors of absolute increase in LVEF (≥ 5%) and proportional changes in LVEF were analyzed. Serial echocardiography demonstrated that LVEF measured 28.6% ± 5.4% preoperatively, 31.5% ± 8.0% median 6 days, and 42.1% ± 10.5% median 11 months postoperatively. Absolute increase of LVEF was observed in 27 patients at pre-discharge and in 24 patients by median 11 months. Proportional changes in LVEF at postoperative median 6 days and 11 months were 14% ± 28% and 57% ± 45%, respectively. The median number of viable myocardial segments was 14 (range, 9-16) in the 16 segment CMR model. Multivariable models demonstrated that the median number of overall viable myocardial segments (≥ 14) in preoperative CMR was associated with absolute increase (P = 0.046) and proportional changes (P = 0.005) in LVEF. In conclusion, the number of viable myocardial segments (≥ 14) in preoperative CMR predicted LV function improvement after CABG in patients with LV dysfunction.


Assuntos
Doença da Artéria Coronariana/patologia , Imagem Cinética por Ressonância Magnética , Função Ventricular Esquerda/fisiologia , Idoso , Meios de Contraste/química , Ponte de Artéria Coronária , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/cirurgia , Ecocardiografia , Feminino , Gadolínio/química , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Revascularização Miocárdica , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento
20.
Radiology ; 280(3): 723-34, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26986048

RESUMO

Purpose To explore the prognostic value of cardiac magnetic resonance (MR) imaging in predicting postoperative cardiac death in patients with severe functional tricuspid regurgitation (TR). Materials and Methods This study was approved by the institutional review board, and written informed consent was obtained from all patients. Prospectively collected data included cardiac MR images, New York Heart Association (NYHA) functional class, a comprehensive laboratory test, and clinical events over the follow-up period in 75 consecutive patients (61 women and 14 men; mean age ± standard deviation, 59 years ± 9) undergoing corrective surgery for severe functional TR. Cox proportional hazards models were used to assess the association between cardiac MR parameters and outcomes. Results During a median follow-up period of 57 months (range, 21-82 months), cardiac mortality and all-cause mortality were 17.3% and 26.7%, respectively, with a surgical mortality of 6.7%. Cardiac death risk was lower with a higher right ventricular (RV) ejection fraction (EF) on cardiac MR images (hazard ratio per 5% higher EF = 0.790, P = .048). By adjusting for confounding variables, RV EF remained a significant predictor for cardiac death (P < .05) and major postoperative cardiac events (P < .05). The area under the receiver operating characteristic curve (AUC) confirmed the incremental role of RV EF on cardiac MR images in the prediction of postoperative cardiac death (AUC, 0.681-0.771; P = .041) and major postoperative cardiac events (AUC, 0.660-0.745; P = .044) on top of NYHA class. RV end-systolic volume index was also independently associated with these outcomes but failed to increase the AUC significantly. Conclusion Preoperative assessment of cardiac MR imaging-based RV EF provides independent and incremental prognostic information in patients undergoing corrective surgery for severe functional TR. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Imageamento por Ressonância Magnética/métodos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Taxa de Sobrevida , Resultado do Tratamento , Insuficiência da Valva Tricúspide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA