Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Mol Pharm ; 19(4): 1183-1190, 2022 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-35230110

RESUMO

In this study, surface diffusion of l-aspartic acid-carvedilol (ASP-CAR) co-amorphous systems at different ASP concentrations is measured and correlated with their physical stability. ASP-CAR films at ASP concentrations of 1-5% (w/w) were prepared by a newly developed method based on a vacuum compression molding process. Surface diffusion measurements were conducted on these systems based on the surface grating decay method using atomic force microscopy (AFM). The results demonstrate that a small amount of ASP (i.e., ≤ 5% w/w) in the co-amorphous systems could significantly slow down the grating decay process compared with that of pure amorphous CAR, indicating a reduced surface diffusion of CAR molecules. The decay time gradually increased in co-amorphous systems with increasing ASP concentration from 1 to 5% (w/w), with the longest observed decay time of around 800 h for the 5%ASP-CAR system, which was more than 200 times longer compared to the decay time of pure amorphous CAR (approximately 3 h). A good correlation between the decay constants of the pure amorphous CAR and co-amorphous films at ASP concentrations of 1-5% (w/w) and the physical stability of corresponding amorphous powder samples was found. Overall, this study provides a new method to prepare co-amorphous films for surface property measurements and reveals the impact of surface diffusion on the physical stability of co-amorphous systems.


Assuntos
Estabilidade de Medicamentos , Carvedilol , Difusão , Pós , Solubilidade , Propriedades de Superfície
2.
Sensors (Basel) ; 22(8)2022 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-35458849

RESUMO

An astigmatic optical profilometer is a precision instrument with advantages such as high resolution, high bandwidth, a compact size, and low cost. However, current astigmatic optical profilometers measure only surface morphology, and their potential for capturing subsurface information remains underutilized. In this study, we developed a method for measuring the thickness of transparent thin films with an astigmatic optical profilometer. Experimental results demonstrate that the thickness of transparent films tens of micrometers thick can be accurately measured. The maximum thickness measurable through our system is approximately 100 µm, which may be increased to 1.2 mm through the use of a scanner with a greater travel range. A coupling problem occurs for films <25 µm in thickness. However, to solve this problem, we devised a decoupling method, which was experimentally implemented to successfully measure a 18-µm-thick film. Moreover, the ability to obtain 3D images, including of both the upper and lower surfaces, was demonstrated.

3.
Sensors (Basel) ; 22(16)2022 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-36016000

RESUMO

An astigmatic optical profilometer with a commercial optical pickup head provides benefits, such as high resolution, compact size, and low cost. To eliminate artifacts caused by complex materials with different reflectances, a z-axis modulation mode is proposed to obtain quantitative surface morphology by measuring S curves on all image pixels. Moreover, the slope of the linear region in the S curve shows a positive relationship with the surface reflectance. However, the slope was calculated using an offline curve fitting method, which did not allow real-time reflectance imaging. Furthermore, quantitative reflectance data were unavailable because of the lack of calibration. In this study, we propose a novel method for real-time reflectance imaging by measuring the amplitude of a focus error signal (FES). The calibration results displayed a linear relationship between the FES amplitude and reflectance. The reflectance image of a grating sample with chrome patterns on a glass substrate demonstrates accurate reflectance measurements with a micrometer spatial resolution.

4.
Int J Mol Sci ; 23(10)2022 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-35628622

RESUMO

Aptamers are single-stranded, short DNA or RNA oligonucleotides that can specifically bind to various target molecules. To diagnose the infected cases of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in time, numerous conventional methods are applied for viral detection via the amplification and quantification of DNA or antibodies specific to antigens on the virus. Herein, we generated a large number of mutated aptamer sequences, derived from a known sequence of receptor-binding domain (RBD)-1C aptamer, specific to the RBD of SARS-CoV-2 spike protein (S protein). Structural similarity, molecular docking, and molecular dynamics (MD) were utilized to screen aptamers and characterize the detailed interactions between the selected aptamers and the S protein. We identified two mutated aptamers, namely, RBD-1CM1 and RBD-1CM2, which presented better docking results against the S protein compared with the RBD-1C aptamer. Through the MD simulation, we further confirmed that the RBD-1CM1 aptamer can form the most stable complex with the S protein based on the number of hydrogen bonds formed between the two biomolecules. Based on the experimental data of quartz crystal microbalance (QCM), the RBD-1CM1 aptamer could produce larger signals in mass change and exhibit an improved binding affinity to the S protein. Therefore, the RBD-1CM1 aptamer, which was selected from 1431 mutants, was the best potential candidate for the detection of SARS-CoV-2. The RBD-1CM1 aptamer can be an alternative biological element for the development of SARS-CoV-2 diagnostic testing.


Assuntos
COVID-19 , Glicoproteína da Espícula de Coronavírus , COVID-19/diagnóstico , DNA de Cadeia Simples , Humanos , Simulação de Acoplamento Molecular , Oligonucleotídeos , SARS-CoV-2/genética , Glicoproteína da Espícula de Coronavírus/genética
5.
Anal Chem ; 91(18): 11620-11628, 2019 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-31335122

RESUMO

Interfacing electrochemical sensors in a lab-on-a-disc (LoD) system with a potentiostat is often tedious and challenging. We here present the first multichannel, modular, lightweight, and wirelessly powered, custom-built potentiostat-on-a-disc (PoD) for centrifugal microfluidic applications. The developed potentiostat is in the form factor of a typical digital video disc (DVD) and weighs only 127 g. The design of the potentiostat facilitates easy and robust interfacing with the electrodes in the LoD system, while enabling real-time electrochemical detection during rotation. The device can perform different electroanalytical techniques such as cyclic voltammetry, square wave voltammetry, and amperometry while being controlled by custom-made software. Measurements were conducted with and without rotation using both in-house fabricated and commercial electrodes. The performance of the PoD was in good agreement with the results obtained using a commercial potentiostat with a measured current resolution of 200 pA. As a proof of concept, we performed a real-time release study of an electrochemically active compound from microdevices used for drug delivery.

6.
J Synchrotron Radiat ; 21(Pt 2): 376-9, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24562558

RESUMO

A compact transmission X-ray microscope has been designed and implemented based on a cylindrical symmetry around the optical axis that sharply limits the instabilities due to thermal mechanical drift. Identical compact multi-axis closed-loop actuation modules drive different optical components. The design is modular and simplifies the change of individual parts, e.g. the use of different magnification and focusing devices. This compact instrument can be easily transported between laboratory and synchrotron facilities and quickly put into operation. An automated alignment mechanism simplifies the assembly of different modules after transportation. After describing the design details, the results of the first tests are presented.

7.
Nanotechnology ; 25(25): 255703, 2014 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-24896069

RESUMO

We demonstrate that the Raman intensities of G and 2D bands of a suspended graphene can be enhanced using a gold tip with an apex size of 2.3 µm. The enhancement decays with the tip-graphene distance exponentially and remains detectable at a distance of 1.5 µm. Raman mappings show that the enhanced area is comparable to the apex size. Application of a bias voltage to the tip can attract the graphene so that Raman signals are intensified. The exponential enhancement-distance relationship enables the measurement of the graphene deformation, and the Young's modulus of graphene is estimated to be 1.48 TPa.

8.
J Invest Dermatol ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38888524

RESUMO

Skin barrier function (SBF) disorders are a class of pathologies that affect a significant portion of the world population. These disorders cause skin lesions with intense itch, impacting patients' physical and psychological well-being as well as their social functioning. It is in the interest of patients that their disorder be monitored closely while under treatment to evaluate the effectiveness of the ongoing therapy and any potential adverse reactions. Symptom-based assessment techniques are widely used by clinicians; however, they carry some limitations. Techniques to assess skin barrier impairment are critical for understanding the nature of the disease and for helping personalize treatment. This review recalls the anatomy of the skin barrier and describes an atomic-force microscopy approach to quantitatively monitor its disorders and their response to treatment. We review a panel of studies that show that this technique is highly relevant for SBF disorder research, and we aim to motivate its adoption into clinical settings.

9.
Nanotechnology ; 24(45): 455503, 2013 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-24141269

RESUMO

In this paper we present a novel scanner design in a quad-rod actuation structure, actuated by piezoelectric disk buzzers, and a new type of atomic force microscope (AFM), which uses this buzzer-scanner and a compact disk/digital-versatile-disk astigmatic optical pickup unit (OPU) for the detection of cantilever movements. Commercially available piezoelectric disk buzzers have a low capacitance and can be driven by low-voltage signal sources, such as analog outputs from a data acquisition card, without additional voltage or current amplifiers. Various scanning ranges can be realized through changing the dimensions of the actuation structure and/or the choice of disk buzzer. We constructed a buzzer-scanner and evaluated its performance. The scanner had a scanning range of 15 µm in the X and Y directions and an actuation range of 3.5 µm on the Z axis, with nonlinearity of 2.11%, 2.73%, and 2.19% for the X,Y and Z axes, respectively. The scanner had a resonance frequency of approximately 360 Hz on the X and Y axes, and 4.12 kHz on the Z axis. An OPU-AFM with this buzzer-scanner can resolve single atomic steps of a graphite substrate with a noise level of 0.06 nm. The obtained topographic images exhibit much less distortion than those obtained with an AFM using a piezoelectric tube scanner.

10.
Nanotechnology ; 24(44): 444011, 2013 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-24113286

RESUMO

In this work the use of a high-throughput nanomechanical detection system based on a DVD-ROM optical drive and cantilever sensors is presented for the detection of urokinase plasminogen activator receptor inflammatory biomarker (uPAR). Several large scale studies have linked elevated levels of soluble uPAR (suPAR) to infectious diseases, such as HIV, and certain types of cancer. Using hundreds of cantilevers and a DVD-based platform, cantilever deflection response from antibody-antigen recognition is investigated as a function of suPAR concentration. The goal is to provide a cheap and portable detection platform which can carry valuable prognostic information. In order to optimize the cantilever response the antibody immobilization and unspecific binding are initially characterized using quartz crystal microbalance technology. Also, the choice of antibody is explored in order to generate the largest surface stress on the cantilevers, thus increasing the signal. Using optimized experimental conditions the lowest detectable suPAR concentration is currently around 5 nM. The results reveal promising research strategies for the implementation of specific biochemical assays in a portable and high-throughput microsensor-based detection platform.


Assuntos
Nanotecnologia/métodos , Dispositivos de Armazenamento Óptico , Óptica e Fotônica/métodos , Receptores de Ativador de Plasminogênio Tipo Uroquinase/metabolismo , Especificidade de Anticorpos , Biomarcadores/metabolismo , Humanos , Fator de Crescimento Derivado de Plaquetas/imunologia , Prognóstico , Técnicas de Microbalança de Cristal de Quartzo , Receptores de Ativador de Plasminogênio Tipo Uroquinase/química , Solubilidade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Compostos de Sulfidrila/metabolismo
11.
HardwareX ; 15: e00449, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37457307

RESUMO

We present an unconventional approach to a common Lab-on-a-Disc (LoD) that combines a quadcopter propulsion system, a miniaturized 2.4 GHz Wi-Fi spy camera, 9.74 Watt Qi wireless power, and an Arduino into an open-source, miniaturized All-in-one powered lab-on-disc platform (APELLA). The quadcopter propulsion generates thrust to rotate (from 0.1 to 24.5 Hz) or shake the LoD device, while the spy camera enables a real-time (30 frames per second) and high definition (1280 × 720 pixels) visualization of microfluidic channels without requiring a bulky and heavy stroboscopic imaging setup. A mobile device can communicate with an Arduino microcontroller inside the APELLA through a Bluetooth interface for closed loop and sequential frequency control. In a proof-of-concept study, the APELLA achieved comparable mixing efficiency to a traditional spin stand and can capture rapid microfluidic events at low rotational frequencies (<5Hz). The APELLA is low-cost (c.a. 100 Euro), compact (15.6 × 15.6 × 10 cm3), lightweight (0.59 kg), portable (powered by a 5 V USB power bank), and energy efficient (uses < 6% power of the conventional system), making it ideal for field deployment, education, resource-limited labs.

12.
Adv Healthc Mater ; 12(4): e2201897, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36414017

RESUMO

During the past decades, microdevices have been evaluated as a means to overcome challenges within oral drug delivery, thus improving bioavailability. Fabrication of microdevices is often limited to planar or simple 3D designs. Therefore, this work explores how microscale stereolithography 3D printing can be used to fabricate radiopaque microcontainers with enhanced mucoadhesive geometries, which can enhance bioavailability by increasing gastrointestinal retention. Ex vivo force measurements suggest increased mucoadhesion of microcontainers with adhering features, such as pillars and arrows, compared to a neutral design. In vivo studies, utilizing planar X-ray imaging, show the time-dependent gastrointestinal location of microcontainers, whereas computed tomography scanning and cryogenic scanning electron microscopy reveal information about their spatial dynamics and mucosal interactions, respectively. For the first time, the effect of 3D microdevice modifications on gastrointestinal retention is traced in vivo, and the applied methods provide a much-needed approach for investigating the impact of device design on gastrointestinal retention.


Assuntos
Sistemas de Liberação de Medicamentos , Tomografia Computadorizada por Raios X , Sistemas de Liberação de Medicamentos/métodos , Disponibilidade Biológica , Microscopia Eletrônica de Varredura , Impressão Tridimensional
13.
HardwareX ; 11: e00308, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35518278

RESUMO

In the pharmaceutical field, oral drug delivery devices continue to shrink down to the micrometer scale, driving a trending demand to investigate ex vivo mucoadhesive force down to the micro-Newton scale. However, owing to the limitation of measuring sensitivity, conventional methods (e.g., a texture analyzer) lack reliability while measuring forces in this range. Herein, we report on an open-source force analyzer that utilizes an optical-pickup-unit (from a DVD player) to detect cantilever-based force transducers and thereby, achieves a wide force-sensing range from 1.1 N to 0.99 nN. The cantilever force transducers can easily be adjusted to fit different force ranges by adjusting the steel shim, magnets, and 3D printed components. To validate the analyzer, we conducted a preliminary study to investigate the effect of time and humidity of mucoadhesion of porcine intestinal tissues. Besides, we measured the mucoadhesive force of a single oral drug delivery microdevice with an average force of 93.7 µN on the top sides of the device. This analyzer offers the possibility of measuring e.g. mucoadhesion of individual microdevices in the micro-Newton range. Hence, the analyzer can assist in the development of miniaturized oral drug delivery devices but has a much wider field of potential force sensing applications.

14.
HardwareX ; 11: e00317, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35647417

RESUMO

Nanoscale positioning has numerous applications in both academia and industry. A growing number of applications require devices with long working distances and nanoscale resolutions. Friction-inertia piezoelectric positioners, which are based on the stick-slip mechanism, achieve both nanometer resolution and centimeter-scale travel. However, the requirements of complex preload mechanism, precision machining, and precise assembly increase the cost of conventional friction-inertia nanopositioners. Herein we present the design of an open-source XYZ-axis nanopositioning system. Utilizing a magnet-based stick-slip driving mechanism, the proposed XYZ nanopositioner provides several advantages, including sub-nanometer resolution, a payload capacity of up to 12 kg (horizontal), compact size, low cost, and easy assembly; furthermore, the system is adjustment-free. The performance tests validate the precision of the system in both scanning and stepping operation modes. Moreover, the resonant spectra affirm the rigidity and dynamic response of the mechanism. In addition, we demonstrate the practical applications of this nanopositioner in various measurement techniques, including scanning electron microscopy, vibrometry, and atomic force microscopy. Furthermore, we present 11 variations of the nanopositioner designs that are either compatible with ultra-high-vacuum systems and other existing systems, 3D printable, or hacking commercial linear slides.

15.
ACS Sens ; 5(7): 2067-2075, 2020 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-32529825

RESUMO

The wide and ever-increasing applications of thermoplasmonics demand the need for sensitive and reliable tools to probe optical absorptions of individual nanoparticles. However, most of the currently available techniques focus only on measuring the surface temperature of nanostructures in a particular medium and are either invasive or suffer from low sensitivity, lengthy calibration, or the inability to probe single structures with nanogaps. Here, we present for the first time the use of micromechanical SiN string resonators for quantifying optical absorption cross sections of individual plasmonic nanostructures. Monomers and dimers of nanospheres, nanostars, shell-isolated nanoparticles, and nanocubes are probed. A reliable data treatment method is developed to obtain the absorption cross sections as a function of responsivity across a string. The presented method exhibits an excellent sensitivity of ∼89 Hz/K. This allows quantification of optical absorption cross sections of individual plasmonic structures even when their plasmon resonance wavelengths are far from the laser excitation wavelength. The experimentally obtained optical absorption cross sections agree well with the simulations. Influencing factors including polarization, surface morphology, and nanogap size are discussed. The developed method and the obtained optical absorption profiles facilitate future development and optimization of thermoplasmonic applications.


Assuntos
Nanosferas , Nanoestruturas , Lasers , Luz , Ressonância de Plasmônio de Superfície
16.
ACS Sens ; 2(9): 1329-1336, 2017 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-28776376

RESUMO

The mechanism of action (MOA) of the first line type-2 diabetes drug metformin remains unclear despite its widespread usage. However, recent evidence suggests that the mitochondrial copper (Cu)-binding action of metformin may contribute toward the drug's MOA. Here, we present a novel biosensing platform for investigating the MOA of metformin using a magnetic microbead-based agglutination assay which has allowed us to demonstrate for the first time the interaction between Cu and metformin at clinically relevant low micromolar concentrations of the drug, thus suggesting a potential pathway of metformin's blood-glucose lowering action. In this assay, cysteine-functionalized magnetic beadswere agglutinated in the presence of Cu due to cysteine's Cu-chelation property. Addition of clinically relevant doses of metformin resulted in disaggregation of Cu-bridged bead-clusters, whereas the effect of adding a closely related but blood-glucose neutral drug propanediimidamide (PDI) showed completely different responses to the clusters. The entire assay was integrated in an automated microfluidics platform with an advanced optical imaging unit by which we investigated these aggregation-disaggregation phenomena in a reliable, automated, and user-friendly fashion with total assay time of 17 min requiring a sample (metformin/PDI) volume of 30 µL. The marked difference of Cu-binding action between the blood-glucose lowering drug metformin and its inactive analogue PDI thus suggests that metformin's distinctive Cu-binding properties may be required for its effect on glucose homeostasis. The novel automated platform demonstrating this novel investigation thus holds the potential to be utilized for investigating significant and sensitive molecular interactions via magnetic bead-based agglutination assay.

17.
Rev Sci Instrum ; 87(5): 053706, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27250434

RESUMO

In this paper, an optical imaging module design for an astigmatic detection system (ADS) is presented. The module is based on a commercial optical pickup unit (OPU) and it contains a coaxial illuminant for illuminating a specimen. Furthermore, the imaging module facilitates viewing the specimen and the detection laser spot of the ADS with a lateral resolution of approximately 1 µm without requiring the removal of an element of the OPU. Two polarizers and one infrared filter are used to eliminate stray laser light in the OPU and stray light produced by the illuminant. Imaging modules designed for digital versatile disks (DVDs) and Blu-ray DVDs were demonstrated. Furthermore, the module can be used for imaging a small cantilever with approximate dimensions of 2 µm (width) × 5 µm (length), and therefore, it has the potential to be used in high-speed atomic force microscopy.

18.
Biosens Bioelectron ; 75: 396-403, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26342583

RESUMO

This paper describes an aptamer-based optomagnetic biosensor for detection of a small molecule based on target binding-induced inhibition of magnetic nanoparticle (MNP) clustering. For the detection of a target small molecule, two mutually exclusive binding reactions (aptamer-target binding and aptamer-DNA linker hybridization) are designed. An aptamer specific to the target and a DNA linker complementary to a part of the aptamer sequence are immobilized onto separate MNPs. Hybridization of the DNA linker and the aptamer induces formation of MNP clusters. The target-to-aptamer binding on MNPs prior to the addition of linker-functionalized MNPs significantly hinders the hybridization reaction, thus reducing the degree of MNP clustering. The clustering state, which is thus related to the target concentration, is then quantitatively determined by an optomagnetic readout technique that provides the hydrodynamic size distribution of MNPs and their clusters. A commercial Blu-ray optical pickup unit is used for optical signal acquisition, which enables the establishment of a low-cost and miniaturized biosensing platform. Experimental results show that the degree of MNP clustering correlates well with the concentration of a target small molecule, adenosine triphosphate (ATP) in this work, in the range between 10µM and 10mM. This successful proof-of-concept indicates that our optomagnetic aptasensor can be further developed as a low-cost biosensing platform for detection of small molecule biomarkers in an out-of-lab setting.


Assuntos
Aptâmeros de Nucleotídeos/química , Biomarcadores/química , Técnicas Biossensoriais , Nanopartículas de Magnetita/química , Trifosfato de Adenosina/química , Sondas de DNA/química , Ouro/química
19.
Biosens Bioelectron ; 67: 649-55, 2015 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-25453736

RESUMO

We present the first implementation of a Blu-ray optical pickup unit (OPU) for the high-performance low-cost readout of a homogeneous assay in a multichamber microfluidic disc with a chamber thickness of 600 µm. The assay relies on optical measurements of the dynamics of magnetic nanobeads in an oscillating magnetic field applied along the light propagation direction. The laser light provided by the OPU is transmitted through the sample chamber and reflected back onto the photo detector array of the OPU via a mirror. Spectra of the 2nd harmonic photo detector signal vs. the frequency of the applied magnetic field show a characteristic peak due to freely rotating magnetic nanobeads. Beads bound to ~1 µm coils of DNA formed off-chip by padlock probe recognition and rolling circle amplification show a different dynamics and the intensity of the characteristic peak decreases. We have determined the optimum magnetic bead concentration to 0.1mg/mL and have measured the response vs. concentration of DNA coils formed from Escherichia Coli. We have found a limit of detection of 10 pM and a dynamic range of about two orders of magnitude, which is comparable to the performance obtained using costly and bulky laboratory equipment. The presented device leverages on the advanced but low-cost technology of Blu-ray OPUs to provide a low-cost and high-performance magnetic bead-based readout of homogeneous bioassays. The device is highly flexible and we have demonstrated its use on microfluidic chambers in a disc with a thickness compatible with current optical media mass-production facilities.


Assuntos
Técnicas Biossensoriais , DNA/isolamento & purificação , Escherichia coli/genética , Dispositivos Lab-On-A-Chip , DNA/química , Replicação do DNA/genética , Fenômenos Magnéticos , Técnicas Analíticas Microfluídicas
20.
Ultramicroscopy ; 135: 121-5, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22939703

RESUMO

We have developed a high-sensitivity atomic force microscopy (AFM) mode operated in aqueous environment based on the torsional resonance of the cantilever. It is found that the torsional mode can achieve a good spatial resolution even with a relatively large tip. We have used this mode to image different soft materials in water, including DNA molecules and purple membrane. High-resolution images of purple membrane can be obtained at a relatively low ion concentration under a long-range electrostatic force. Thus the torsional mode allows investigators to probe surface structures and their properties under a wide range of solution conditions.


Assuntos
Microscopia de Força Atômica/métodos , Água/química , DNA/química , Membrana Purpúrea/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA