Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Cardiovasc Electrophysiol ; 33(5): 997-1004, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35322490

RESUMO

INTRODUCTION: Device infections constitute a major complication of transvenous pacemakers. Mechanical heart valves (MHV) increase the risk of infective endocarditis (IE) and pacemaker infection, requiring lifelong vitamin K-antagonists (VKA), which may affect patient management. Leadless pacemakers (LP) are associated with low infection rates, posing an attractive option in MHV patients requiring permanent pacing. This study describes outcomes following LP implantation in patients with MHV. METHODS: This is a multicenter, observational, retrospective study including consecutive patients implanted with an LP at 5 centers between June 2015 and January 2020. Procedural outcomes, antithrombotic management, complications, performance during follow-up and episodes of bacteremia and IE were compared between patients with and without an MHV (MHV and non-MHV groups). RESULTS: Four hundred fifty-nine patients were included (74 in the MHV group, 16.1%, and 385 in the non-MHV group, 83.9%). Procedural outcomes and acute electrical performance were comparable between groups. Vascular complications and cardiac perforation occurred in 2.7 versus 2.3% (p = 1) and 0% versus 0.8% (p = 1) in the MHV group and non-MHV group. One case of IE occurred in the MHV group and 2 in the non-MHV group. In MHV patients, uninterrupted VKA was used in 83.8%, whereas 16.2% were heparin-bridged. Vascular complication or tamponade occurred in 1 (8.3%) MHV heparin-bridged patient versus 1 (1.6%) MHV uninterrupted VKA patient (p = .3). CONCLUSION: LP implantation outcomes in MHV patients are comparable to the general LP population. Device-related infections are rare following LP implantation, including in patients with MHV. In the MHV group, periprocedural anticoagulation management was not associated with significantly different rates of tamponade or vascular complication.


Assuntos
Próteses Valvulares Cardíacas , Marca-Passo Artificial , Valvas Cardíacas , Heparina , Humanos , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
2.
Anesthesiology ; 132(4): 667-677, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32011334

RESUMO

BACKGROUND: Pneumoperitoneum for laparoscopic surgery is associated with a rise of driving pressure. The authors aimed to assess the effects of positive end-expiratory pressure (PEEP) on driving pressure at varying intraabdominal pressure levels. It was hypothesized that PEEP attenuates pneumoperitoneum-related rises in driving pressure. METHODS: Open-label, nonrandomized, crossover, clinical trial in patients undergoing laparoscopic cholecystectomy. "Targeted PEEP" (2 cm H2O above intraabdominal pressure) was compared with "standard PEEP" (5 cm H2O), with respect to the transpulmonary and respiratory system driving pressure at three predefined intraabdominal pressure levels, and each patient was ventilated with two levels of PEEP at the three intraabdominal pressure levels in the same sequence. The primary outcome was the difference in transpulmonary driving pressure between targeted PEEP and standard PEEP at the three levels of intraabdominal pressure. RESULTS: Thirty patients were included and analyzed. Targeted PEEP was 10, 14, and 17 cm H2O at intraabdominal pressure of 8, 12, and 15 mmHg, respectively. Compared to standard PEEP, targeted PEEP resulted in lower median transpulmonary driving pressure at intraabdominal pressure of 8 mmHg (7 [5 to 8] vs. 9 [7 to 11] cm H2O; P = 0.010; difference 2 [95% CI 0.5 to 4 cm H2O]); 12 mmHg (7 [4 to 9] vs.10 [7 to 12] cm H2O; P = 0.002; difference 3 [1 to 5] cm H2O); and 15 mmHg (7 [6 to 9] vs.12 [8 to 15] cm H2O; P < 0.001; difference 4 [2 to 6] cm H2O). The effects of targeted PEEP compared to standard PEEP on respiratory system driving pressure were comparable to the effects on transpulmonary driving pressure, though respiratory system driving pressure was higher than transpulmonary driving pressure at all intraabdominal pressure levels. CONCLUSIONS: Transpulmonary driving pressure rises with an increase in intraabdominal pressure, an effect that can be counterbalanced by targeted PEEP. Future studies have to elucidate which combination of PEEP and intraabdominal pressure is best in term of clinical outcomes.


Assuntos
Abdome/fisiopatologia , Laparoscopia/métodos , Monitorização Intraoperatória/métodos , Pneumoperitônio/fisiopatologia , Respiração com Pressão Positiva/métodos , Idoso , Estudos Cross-Over , Feminino , Humanos , Laparoscopia/efeitos adversos , Masculino , Pessoa de Meia-Idade , Pneumoperitônio/diagnóstico , Pneumoperitônio/etiologia , Respiração com Pressão Positiva/efeitos adversos , Volume de Ventilação Pulmonar/fisiologia
3.
Eur J Pediatr Surg ; 30(2): 210-214, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31022755

RESUMO

INTRODUCTION: Repair of large congenital diaphragmatic hernias (CDHs) is challenging. As primary repair is not always feasible, patches are commonly used. An alternative treatment is split abdominal wall muscle flap repair, which uses vascularized autologous tissue. The aim of this study was to analyze the long-term outcome of large CDH defects undergoing split abdominal wall muscle repair. MATERIALS AND METHODS: This is a retrospective review (2003-2016) of large CDH treated by split abdominal wall muscle flap repair. RESULTS: In a total of 107 CDH patients, the abdominal muscle flap technique was used in 10 (9.3%); 7 had been prenatally treated with tracheal occlusion. Two patients experienced recurrence at 2 months and 6 years, respectively. Only one patient required abdominoplasty due to abdominal wall muscle weakness. Two patients developed progressive scoliosis; one of them required orthopaedic treatment. Minor chest wall deformities were detected in seven, but only one required orthopaedic treatment. The lung-to-head ratio was 0.79 in patients developing musculoskeletal deformities, and 1.5 in those without this complication (p < 0.05). Median follow-up was 11.2 years (3.5-14.2), and all patients were alive at the time of writing this article. CONCLUSION: The split abdominal wall muscle flap technique is a valid option for repair of large CDH. Associated musculoskeletal deformities seem to be influenced not only by the repair technique used but also by the degree of pulmonary hypoplasia and inherent pathophysiological changes.


Assuntos
Músculos Abdominais/transplante , Fetoscopia/métodos , Hérnias Diafragmáticas Congênitas/cirurgia , Retalhos Cirúrgicos/transplante , Parede Abdominal/cirurgia , Feminino , Fetoscopia/efeitos adversos , Idade Gestacional , Humanos , Recém-Nascido , Tempo de Internação , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença
4.
J Interv Card Electrophysiol ; 57(3): 333-343, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30242552

RESUMO

PURPOSE: Ablation of atrioventricular (AV) conduction and pacemaker implantation is the therapy of last resort for symptomatic atrial tachyarrythmias when rhythm and rate control fail, but is far from ideal. To evaluate whether interatrial electrical disconnection as a result of catheter ablation is feasible and of potential clinical utility as a means of non-pharmacological heart rate control. METHODS: Eleven patients with medically refractory atrial fibrillation or left atrial flutter and symptomatic rapid ventricular response were included. The ablation strategy consisted primarily of right atrial ablation of the interatrial electrical connections, which were located by electroanatomical activation maps performed during coronary sinus stimulation. Successive activation maps were performed as each connection was blocked. If the procedure was considered unsuccessful AV nodal ablation was performed. RESULTS: The coronary sinus ostium was earliest in 10/11 and could be ablated in 5/10 patients. Interatrial conduction block was only achieved in one patient (9.1%). An unexpected AV nodal modulation with an increase in the Wenckebach cycle length (> 50 ms) occurred in 8/11 patients. These patients remained without pacemaker implantation and only 1/8 required AV nodal ablation during the 1-year follow-up. Quality of life questionnaires indicated significant improvement in patients with AV nodal modulation. CONCLUSION: Interatrial electrical disconnection by right atrial catheter ablation is a not feasible with present day technology. The extensive right atrial septal ablation performed resulted in significant AV nodal modulation in most patients, which persisted and resulted in improvement in quality of life.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Frequência Cardíaca , Idoso , Ecocardiografia , Eletrocardiografia Ambulatorial , Mapeamento Epicárdico , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida
5.
Rev Esp Cardiol (Engl Ed) ; 72(12): 1020-1030, 2019 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30935899

RESUMO

INTRODUCTION AND OBJECTIVES: We describe the results for Spain of the Second European Cardiac Resynchronization Therapy Survey (CRT-Survey II) and compare them with those of the other participating countries. METHODS: We included patients undergoing CRT device implantation between October 2015 and December 2016 in 36 participating Spanish centers. We registered the patients' baseline characteristics, implant procedure data, and short-term follow-up information until hospital discharge. RESULTS: Implant success was achieved in 95.9%. The median [interquartile range] annual implantation rate by center was significantly lower in Spain than in the other participating countries: 30 implants/y [21-50] vs 55 implants/y [33-100]; P=.00003. In Spanish centers, there was a lower proportion of patients ≥ 75 years (27.9% vs 32.4%; P=.0071), a higher proportion in New York Heart Association functional class II (46.9% vs 36.9%; P <.00001), and a higher percentage with electrocardiographic criteria of left bundle branch block (82.9% vs 74.6%; P <.00001). The mean length of hospital stay was significantly lower in Spanish centers (5.8±8.5 days vs 6.4±11.6; P <.00001). Spanish patients were more likely to receive a quadripolar LV lead (74% vs 56%; P <.00001) and to be followed up by remote monitoring (55.8% vs 27.7%; P <.00001). CONCLUSIONS: The CRT-Survey II shows that, compared with other participating countries, fewer patients in Spain aged ≥ 75 years received a CRT device, while more patients were in New York Heart Association functional class II and had left bundle branch block. In addition, the length of hospital stay was shorter, and there was greater use of quadripolar LV leads and remote CRT monitoring.


Assuntos
Arritmias Cardíacas/terapia , Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Inquéritos e Questionários , Idoso , Arritmias Cardíacas/epidemiologia , Eletrocardiografia , Europa (Continente)/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Morbidade/tendências , Estudos Retrospectivos , Espanha/epidemiologia
6.
Rev Esp Cardiol (Engl Ed) ; 70(11): 971-982, 2017 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28939092

RESUMO

INTRODUCTION AND OBJECTIVES: This report describes the findings of the 2016 Spanish Catheter Ablation Registry. METHODS: Data were retrospectively collected by means of a standardized questionnaire completed by each of the participating centers. RESULTS: Data were collected from 83 centers. A total of 13 482 ablation procedures were performed (the highest historically reported in this registry), with a mean of 162.4 ± 116 and a median of 136 procedures per center. The most frequently treated ablation targets were atrioventricular nodal re-entrant tachycardia (n = 3058; 22.7%), atrial fibrillation (n = 2953; 21.9%), and cavotricuspid isthmus (n = 2892; 21.4%). There was a peak in ablation procedures for atrial fibrillation, which, for the first time in this registry, became the second most treated substrate. After exclusion of atrial fibrillation and ventricular tachycardia with underlying heart disease, the overall success rate was 86%. The rate of major complications was 2.3%, and the mortality rate was 0.05%. In all, 2.7% of the ablations were performed in pediatric patients. CONCLUSIONS: The Spanish Catheter Ablation Registry systematically and uninterruptedly records the ablation procedures performed in Spain, showing a progressive rise in the number of ablations performed, with a high success rate and a low percentage of complications.


Assuntos
Arritmias Cardíacas/terapia , Ablação por Cateter/estatística & dados numéricos , Arritmias Cardíacas/epidemiologia , Unidades de Cuidados Coronarianos/estatística & dados numéricos , Hospitalização/estatística & dados numéricos , Humanos , Corpo Clínico Hospitalar/estatística & dados numéricos , Sistema de Registros , Estudos Retrospectivos , Espanha/epidemiologia
7.
Rev. Méd. Clín. Condes ; 32(5): 535-542, sept.-oct. 2021. tab
Artigo em Espanhol | LILACS | ID: biblio-1526030

RESUMO

Los trastornos del sueño son frecuentes en la población y una causa importante de morbilidad. El objetivo de esta revisión es evaluar las alteraciones del sueño en periodos de emergencia y desastres. A lo largo de la historia, la esfera biopsicosocial y el sueño de las personas ha sido abrumada por múltiples eventos a gran escala, tales como desastres naturales, tragedias provocadas por el hombre, conflictos bélicos, crisis sociales y pandemias, cuya experiencia puede derivar en problemas de salud a corto, mediano y/o largo plazo. En los estudios analizados, se ha observado el impacto negativo de las emergencias y desastres en el sueño, por lo que ha cobrado gran relevancia la difusión y promoción de medidas que incentiven el buen dormir. Debido a la llegada del COVID-19 y a la situación de confinamiento por periodos prolongados en el hogar para prevenir su propagación, han surgido importantes consecuencias a nivel social. Ciertos factores ocupacionales y características de los desastres se asocian a mayor comorbilidad, un alto riesgo de experimentar agotamiento físico, trastornos psicológicos e insomnio en grupos altamente vulnerables, como lo son los profesionales de la salud, rescatistas y socorristas. El insomnio es el trastorno de sueño más frecuente en la población general y su empeoramiento en el contexto de pandemia por COVID-19 representa un nuevo problema en salud pública. Es por ello, que es indispensable promover campañas de prevención de salud física y mental orientados a la pesquisa precoz y manejo de patologías de la esfera psicosocial, dentro de las posibilidades socioeconómicas.


Sleep disorders are common in the population and are major cause of morbidity. The objective of this review is to assess sleep disturbances in times of emergency and disasters. Throughout history, the biopsychosocial field and sleep have been affected by multiple large-scale events, such as natural disasters, man-caused tragedies, armed conflicts, social crises and pandemics, the experience of which can lead to short, medium and/or long term health problems. In several studies, the negative impact of emergencies and disasters on sleep have been analyzed, emphasizing the importance of the diffusion and promotion of measures that encourage good sleep. The arrival of COVID-19 and consequent home confinement for prolonged periods caused important social consequences. Certain occupational factors and characteristics of disasters are associated with greater comorbidity: a high risk of experiencing physical exhaustion, psychological disorders and insomnia, especially in highly vulnerable groups, such as health professionals, rescuers and first aids-responders. Insomnia is the most frequent sleep disorder in the general population and its worsening in the context of the COVID-19 pandemic, represents a new public health problem. It is essential to promote physical and mental health prevention campaigns, aimed at early screening and management of pathologies in the psychosocial sphere, within socioeconomic possibilities.


Assuntos
Humanos , Transtornos do Sono-Vigília/diagnóstico , Transtornos do Sono-Vigília/psicologia , Transtornos do Sono-Vigília/prevenção & controle , Emergências em Desastres , Quarentena , Pessoal de Saúde/psicologia , Desastres , Pandemias , Socorristas/psicologia , COVID-19 , Distúrbios do Início e da Manutenção do Sono/classificação , Distúrbios do Início e da Manutenção do Sono/diagnóstico
9.
Cuad Bioet ; 20(70): 487-501, 2009.
Artigo em Espanhol | MEDLINE | ID: mdl-19799486

RESUMO

The article focuses on the different factors and circumstances that have led to the reform of Spanish Abortion Law (1985). Judicial investigations of several abortion clinics have demonstrated that up until today there has been a widespread tendency of the clinics to practice beyond the limits established by the law. Nonetheless, the reaction of the government has not been to protect the life of the unborn. Its reaction has been, however, to cover the irregularities committed by the abortionists through the legalization of their abusive practices. Besides, the reform of the law has been inspired by elements of radical feminism. The author points out the major reasons that make this reform unconstitutional and offers alternative solutions for the protection of the mother and the unborn child.


Assuntos
Aborto Induzido/legislação & jurisprudência , Aborto Induzido/psicologia , Aborto Induzido/estatística & dados numéricos , Aborto Induzido/tendências , Constituição e Estatutos , Feminino , Feminismo , Humanos , Autonomia Pessoal , Gravidez , Opinião Pública , Espanha , Valor da Vida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA