Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
2.
Artigo em Inglês | MEDLINE | ID: mdl-38649641

RESUMO

BACKGROUND: Concomitant tricuspid valve (TV) repair is a safe and effective procedure to protect against late moderate or greater tricuspid regurgitation (TR) after left-sided valve surgery, but studies regarding its late outcomes and recurrent TR are limited. This study aimed to reveal the late outcomes and explore the predictors of mortality and recurrent TR among patients who underwent concomitant TV repair with left-sided valve surgery. METHODS AND RESULTS: This study included 645 patients (mean age, 69.7 years; 44% male) who underwent concomitant TV repair with left-sided valve surgery (mitral valve surgery in 594 cases, aortic valve surgery in 172 cases) from 2006-2020. Preoperative TR was grade 4, 3, and less than 2 in 85, 235, and 325 patients, respectively. The median follow-up period was 4.6 (IQR 1.7-7.8) years. The in-hospital or 30-day mortality was 1.7% (n = 11). Regarding long-term outcomes after TV repair, 90.3% and 80.8% achieved 5- and 10-year survival, respectively, while 96.1% and 88.8% achieved 5- and 10-year freedom from recurrent TR, respectively. The following were independent predictors of overall mortality on multivariate analysis in patients with preoperative TR grade ≥ 3: prior pacemaker implantation, preoperative renal dysfunction, diabetes mellitus and NYHA class ≥ 3. Also, suture annuloplasty and ring type of ring annuloplasty were not independent risk factors for recurrent TR, classified as grade ≥ 3. CONCLUSIONS: Concomitant TV repair with left-sided valve surgery had acceptable outcomes in terms of survival and TR durability. In patients with preoperative TR grade ≥ 3, preoperative patient status had negative impacts on prognosis.

3.
J Cardiothorac Surg ; 19(1): 211, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38616249

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has become widely used in recent years, However, there is also an increasing need for removal of TAVR valves due to prosthetic valve dysfunction (PVD) and the development of infective endocarditis. Surgical aortic valve replacement (AVR) for these patients is risky due to the original patient background and anatomic conditions. Intuity rapid deployment aortic valve (Edwards Lifesciences, Irvine, CA) replacement would be useful for such high risk patients to prevent longer cardiac arrest time and obtain good hemodynamic results. However, there are few reports which present Intuity valve replacement after TAVR explantation. Herein, We report two cases in which we have achieved good hemodynamics with shorter cardiac arrest times by using a rapid deployment valve after TAVR explantation. CASE PRESENTATION: We present 2 cases of successful implantation of the Intuity rapid deployment valve after TAVR explantation. The 84- and 88-year-old female patients had previously received TAVR for severe aortic stenosis with SAPIEN XT (Edwards Lifesciences, Irvine, CA) and developed PVD during follow-up. The TAVR valve was removed carefully, then an Intuity valve was implanted with cardiac arrest times of 69 and 41 min. Both patients had good echocardiographic results with effective orifice area of 2.0 cm2 and 1.2 cm2 and mean trans-aortic plessure gradient of 9 mmHg and 15 mmHg respectively without aortic regurgitation. They were discharged without major complications. CONCLUSIONS: Surgical AVR using a rapid deployment valve is a useful alternative to sutured AVR after TAVR valve explantation. It allows for shorter cardiac arrest times and better postoperative hemodynamics without major complication.


Assuntos
Insuficiência da Valva Aórtica , Parada Cardíaca , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Remoção de Dispositivo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA