Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Magn Reson Med ; 89(2): 508-521, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36161728

RESUMO

PURPOSE: This study aimed to develop a new 3D dual-echo rosette k-space trajectory, specifically designed for UTE MRI applications. The imaging of the ultra-short transverse relaxation time (uT2 ) of brain was acquired to test the performance of the proposed UTE sequence. THEORY AND METHODS: The rosette trajectory was developed based on rotations of a "petal-like" pattern in the kx -ky plane, with oscillated extensions in the kz -direction for 3D coverage. Five healthy volunteers underwent 10 dual-echo 3D rosette UTE scans with various TEs. Dual-exponential complex model fitting was performed on the magnitude data to separate uT2 signals, with the output of uT2 fraction, uT2 value, and long-T2 value. RESULTS: The 3D rosette dual-echo UTE sequence showed better performance than a 3D radial UTE acquisition. More significant signal intensity decay in white matter than gray matter was observed along with the TEs. The white matter regions had higher uT2 fraction values than gray matter (10.9% ± 1.9% vs. 5.7% ± 2.4%). The uT2 value was approximately 0.10 ms in white matter . CONCLUSION: The higher uT2 fraction value in white matter compared to gray matter demonstrated the ability of the proposed sequence to capture rapidly decaying signals.


Assuntos
Imageamento por Ressonância Magnética , Substância Branca , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Substância Cinzenta/diagnóstico por imagem , Voluntários Saudáveis , Imageamento Tridimensional
2.
Magn Reson Med ; 90(4): 1728-1737, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37350426

RESUMO

PURPOSE: To improve intraoral transverse loop coil design for high-resolution dental MRI. METHODS: The transverse intraoral loop coil (tLoop) was modified (mtLoop) by overlapping the feed port conductors, bending the posterior section, introducing a parallel plate capacitor, optimizing the insulation thickness, and using it in receive-only mode. In addition, an MR-silent insulation was introduced. The performances of the mtLoop and tLoop coils were compared in terms of sensitivity, image SNR, and eddy currents using electromagnetic simulations and MRI measurements at 3T. RESULTS: The receive-only mode of the mtLoop increases the sensitivity at the apices of the roots, and the overlapped feed port design eliminated signal voids along the incisors. The bent posterior section with the parallel plate capacitor reduced the unwanted signal of the tongue by a factor of 2.3 in the selected region off interest and lowered the eddy currents by 10%. The proposed new coil provided higher SNR by elevenfold and 2.5-fold at the incisors and apices of the molar roots within the selected regions of interest, respectively, in the experiments, as well as improved comfort. Optimal insulation thickness was determined as 1 mm. With the mtLoop, a (250 µm)3 isotropic resolution of the dental arch could be realized using a UTE sequence within 2 min total acquisition time. A T2 -SPACE protocol with (350 µm)2 in-plane resolution was also demonstrated. CONCLUSION: The proposed new coil offers higher SNR at the incisors and apices of the molar roots, less unwanted signals from tongue, lower eddy currents, and improved patient comfort.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Humanos , Desenho de Equipamento , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos
3.
Magn Reson Med ; 89(3): 1237-1250, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36226654

RESUMO

PURPOSE: To introduce an RF coil system consisting of an 8-channel transmit (Tx) and 8-channel receive (Rx) coil arrays for 19 F MRI of large animals. METHODS: The Tx efficiency and homogeneity of the 8-element loop coil array (loop size: 6 × 15 cm2 ) were simulated for two different pig models rendered from MR images. An 8-channel Rx coil array consisting of a flexible 6-channel posterior and a 2-channel planar anterior array was designed to fit on the abdomen of an average-sized pig in supine position. Measurements were performed in a grid phantom and ex vivo on a pig model with perfluoroctylbromide (PFOB)-filled tubes inserted in the thorax. RESULTS: Measured and simulated Tx efficiency and homogeneity for the 8-channel and 5-channel arrays were in good agreement: 1.87 ± 0.22µT/√kW versus 1.96 ± 0.29µT/√kW, and 2.29 ± 0.39µT/√kW versus 2.41 ± 0.37µT/√kW. An isolation of 38 ± 8 dB is achieved between the 19 F Tx and Rx elements, and over 30 dB between the 1 H and 19 F elements. The PFOB-filled vials could be clearly identified within the cadaver abdomen with an SNR of 275 ± 51 for a 3D gradient-echo sequence with 2-mm isotropic resolution and 12 averages, acquired in 9:52 min:s. Performance of the Tx array was robust against phase and amplitude mismatches at the input ports. CONCLUSIONS: A modular and scalable Tx array offers improved Tx efficiency in 19 F MRI of large animals with various sizes. Although conventional birdcage coils have superior Tx efficiency within the target region of interest, scalability of the Tx array to animal size is a major benefit. The described 19 F coil provides homogeneous excitation and high sensitivity detection in large pig models.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Animais , Suínos , Razão Sinal-Ruído , Desenho de Equipamento , Imagens de Fantasmas , Imageamento por Ressonância Magnética/veterinária , Imageamento por Ressonância Magnética/métodos
4.
Magn Reson Med ; 87(6): 2685-2696, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35037292

RESUMO

PURPOSE: To accelerate the Pointwise Encoding Time Reduction with Radial Acquisition (PETRA) sequence using compressed sensing while preserving the image quality for high-resolution MRI of tissue with ultra-short T2∗ values. METHODS: Compressed sensing was introduced in the PETRA sequence (csPETRA) to accelerate the time-consuming single point acquisition of the k-space center data. Random undersampling was applied to achieve acceleration factors up to Acc = 32. Phantom and in vivo images of the knee joint of six volunteers were measured at 3T using csPETRA sequence with Acc = 4, 8, 12, 16, 24, and 32. Images were compared against fully sampled PETRA data (Acc = 1) for structural similarity and normalized-mean-square-error. Qualitative and semi-quantitative analyses were performed to assess the effect of the acceleration on image artifacts, image quality, and delineation of anatomical structures at the knee. RESULTS: Even at high acceleration factors of Acc = 16 no aliasing artifacts were observed, and the anatomical details were preserved compared with the fully sampled data. The normalized-mean-square-error was less than 1% for Acc = 16, in which single point imaging acquisition time was reduced from 165 to 10 s, reducing the total scan time from 7.8 to 5.2 min. Semi-quantitative analyses suggest that Acc = 16 yields comparable diagnostic quality as the fully sampled data for knee imaging at a scan time of 5.2 min. CONCLUSION: csPETRA allows for ultra-short T2∗ imaging of the knee joint in clinically acceptable scan times while maintaining the image quality of original non-accelerated PETRA sequence.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Humanos , Processamento de Imagem Assistida por Computador/métodos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
5.
MAGMA ; 35(2): 301-310, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34542771

RESUMO

OBJECTIVE: The slow spatial encoding of MRI has precluded its application to rapid physiologic motion in the past. The purpose of this study is to introduce a new fast acquisition method and to demonstrate feasibility of encoding rapid two-dimensional motion of human vocal folds with sub-millisecond resolution. METHOD: In our previous work, we achieved high temporal resolution by applying a rapidly switched phase encoding gradient along the direction of motion. In this work, we extend phase encoding to the second image direction by using single-point imaging with rapid encoding (SPIRE) to image the two-dimensional vocal fold oscillation in the coronal view. Image data were gated using electroglottography (EGG) and motion corrected. An iterative reconstruction with a total variation (TV) constraint was used and the sequence was also simulated using a motion phantom. RESULTS: Dynamic images of the vocal folds during phonation at pitches of 150 and 165 Hz were acquired in two volunteers and the periodic motion of the vocal folds at a temporal resolution of about 600 µs was shown. The simulations emphasize the necessity of SPIRE for two-dimensional motion encoding. DISCUSSION: SPIRE is a new MRI method to image rapidly oscillating structures and for the first time provides dynamic images of the vocal folds oscillations in the coronal plane.


Assuntos
Imageamento por Ressonância Magnética , Prega Vocal , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Movimento , Imagens de Fantasmas , Prega Vocal/diagnóstico por imagem
6.
Nanomaterials (Basel) ; 13(2)2023 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-36678084

RESUMO

Magnetic nanoparticles (MNPs) have been widely applied as magnetic resonance imaging (MRI) contrast agents. MNPs offer significant contrast improvements in MRI through their tunable relaxivities, but to apply them as clinical contrast agents effectively, they should exhibit a high saturation magnetization, good colloidal stability and sufficient biocompatibility. In this work, we present a detailed description of the synthesis and the characterizations of europium-substituted Mn-Zn ferrite (Mn0.6Zn0.4EuxFe2-xO4, x = 0.00, 0.02, 0.04, 0.06, 0.08, 0.10, and 0.15, herein named MZF for x = 0.00 and EuMZF for others). MNPs were synthesized by the coprecipitation method and subsequent hydrothermal treatment, coated with citric acid (CA) or pluronic F127 (PF-127) and finally characterized by X-ray Diffraction (XRD), Inductively Coupled Plasma (ICP), Vibrating Sample Magnetometry (VSM), Fourier-Transform Infrared (FTIR), Dynamic Light Scattering (DLS) and MRI Relaxometry at 3T methods. The XRD studies revealed that all main diffraction peaks are matched with the spinel structure very well, so they are nearly single phase. Furthermore, XRD study showed that, although there are no significant changes in lattice constants, crystallite sizes are affected by europium substitution significantly. Room-temperature magnetometry showed that, in addition to coercivity, both saturation and remnant magnetizations decrease with increasing europium substitution and coating with pluronic F127. FTIR study confirmed the presence of citric acid and poloxamer (pluronic F127) coatings on the surface of the nanoparticles. Relaxometry measurements illustrated that, although the europium-free sample is an excellent negative contrast agent with a high r2 relaxivity, it does not show a positive contrast enhancement as the concentration of nanoparticles increases. By increasing the europium to x = 0.15, r1 relaxivity increased significantly. On the contrary, europium substitution decreased r2 relaxivity due to a reduction in saturation magnetization. The ratio of r2/r1 decreased from 152 for the europium-free sample to 11.2 for x = 0.15, which indicates that Mn0.6Zn0.4Eu0.15Fe1.85O4 is a suitable candidate for dual-mode MRI contrast agent potentially. The samples with citric acid coating had higher r1 and lower r2 relaxivities than those of pluronic F127-coated samples.

7.
J Trace Elem Med Biol ; 77: 127146, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36871432

RESUMO

BACKGROUND: The iron concentration increases during normal brain development and is identified as a risk factor for many neurodegenerative diseases, it is vital to monitor iron content in the brain non-invasively. PURPOSE: This study aimed to quantify in vivo brain iron concentration with a 3D rosette-based ultra-short echo time (UTE) magnetic resonance imaging (MRI) sequence. METHODS: A cylindrical phantom containing nine vials of different iron concentrations (iron (II) chloride) from 0.5 millimoles to 50 millimoles and six healthy subjects were scanned using 3D high-resolution (0.94 ×0.94 ×0.94 mm3) rosette UTE sequence at an echo time (TE) of 20 µs. RESULTS: Iron-related hyperintense signals (i.e., positive contrast) were detected based on the phantom scan, and were used to establish an association between iron concentration and signal intensity. The signal intensities from in vivo scans were then converted to iron concentrations based on the association. The deep brain structures, such as the substantia nigra, putamen, and globus pallidus, were highlighted after the conversion, which indicated potential iron accumulations. CONCLUSION: This study suggested that T1-weighted signal intensity could be used for brain iron mapping.


Assuntos
Ferro , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico/métodos , Meios de Contraste
8.
Z Med Phys ; 2022 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-36328861

RESUMO

PURPOSE: To maximize acquisition bandwidth in zero echo time (ZTE) sequences, readout gradients are already switched on during the RF pulse, creating unwanted slice selectivity. The resulting image distortions are amplified especially when the anatomy of interest is not located at the isocenter. We aim to characterize off-center ZTE MRI of extremities such as the shoulder, knee, and hip, adjusting the carrier frequency of the RF pulse excitation for each TR. METHODS: In ZTE MRI, radial encoding schemes are used, where the distorted slice profile due to the finite RF pulse length rotates with the k-space trajectory. To overcome these modulations for objects far away from the magnet isocenter, the frequency of the RF pulse is shifted for each gradient setting so that artifacts do not occur at a given off-center target position. The sharpness of the edges in the images were calculated and the ZTE acquisition with off-center excitation was compared to an acquisition with isocenter excitation both in phantom and in vivo off-center MRI of the shoulder, knee, and hip at 1.5 and 3T MRI systems. RESULTS: Distortion and blurriness artifacts on the off-center MRI images of the phantom, in vivo shoulder, knee, and hip images were mitigated with off-center excitation without time or noise penalty, at no additional computational cost. CONCLUSION: The off-center excitation allows ZTE MRI of the shoulder, knee, and hip for high-bandwidth image acquisitions for clinical settings, where positioning at the isocenter is not possible.

9.
Med Phys ; 46(4): 1592-1607, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30695100

RESUMO

PURPOSE: Magnetic particle imaging (MPI) is a relatively new method to image the spatial distribution of magnetic nanoparticle (MNP) tracers administered to the body with high spatial and temporal resolution using an inhomogeneous magnetic field. The spatial information of the MNP's is encoded using a field free point (FFP), or a field free line (FFL), in which the magnetic field vanishes at a point, or on a line, respectively. FFL scanning has the advantage of improved sensitivity compared to FFP scanning as a result of higher signal-to-noise ratio. The trajectory traversed by the FFL or FFP is an important parameter of the MPI system and should be selected to achieve the best imaging quality in minimum scan time, while considering hardware constraints and patient safety. In this study, we analyzed the image quality of different FFL trajectories for a large field of view (FOV) using simulations, to provide a baseline information for FFL scanning MPI system design. METHODS: We simulated a human-sized FFL scanning MPI configuration to image a circular FOV with 160 mm diameter, and compared Radial, Spiral, Uniform Spiral, Flower, and Lissajous trajectories with different trajectory densities scanned by the FFL for constant scan time. We analyzed the system matrices of the trajectories in terms of mutual coherence and homogeneity of the spatial sensitivity. We calculated the maximum electric fields induced on a homogeneous conductive body by the selection field (SF) and the focus field (FF) to compare the trajectories based on the nerve stimulation threshold. The images were obtained using the system matrix reconstruction approach with two different image reconstruction methods. In the first one, we used the conventional image reconstruction method, algebraic reconstruction technique (ART), which gives a regularized least-squares solution. In the second one, we used the state-of-the-art alternating direction method of multipliers (ADMM), which minimizes a weighted sum of the l1 -norm and the total variation (TV) of the images. RESULTS: The Radial and Spiral trajectories resulted in a poor imaging performance at low trajectory densities due to relatively high coherency and poor sensitivity of the measurements, respectively. For ART reconstruction, the highest image quality with the lowest trajectory density was achieved with the Uniform Spiral trajectory. Uniform Spiral, Flower, and Lissajous trajectories yielded comparable performance with ADMM reconstruction. The rotating SF induced higher electric field amplitude compared to the FF. Consequently, maximum allowable gradient at the same trajectory density was greater for the Radial trajectory compared to the other trajectories. CONCLUSIONS: For a large FOV coverage, the Uniform Spiral trajectory offers a good compromise between image quality and imaging time, taking safety and hardware limitations into account. The Radial trajectory, especially using l1 -norm and TV priors in the reconstruction, may be favorable in case the SF induced electric field is higher than that of the FF at the same frequency (e.g., relatively small FOV coverage). In general, ADMM reconstruction resulted in higher contrast and resolution compared to ART, leading to lighter requirements on the density of the trajectory.


Assuntos
Campos Magnéticos , Imageamento por Ressonância Magnética/métodos , Nanopartículas de Magnetita/química , Imagens de Fantasmas , Razão Sinal-Ruído , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador/métodos
10.
IEEE Trans Med Imaging ; 38(9): 2070-2080, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30714915

RESUMO

Magnetic particle imaging (MPI) is a relatively new medical imaging modality, which detects the nonlinear response of magnetic nanoparticles (MNPs) that are exposed to external magnetic fields. The system matrix (SM) method for MPI image reconstruction requires a time consuming system calibration scan prior to image acquisition, where a single MNP sample is measured at each voxel position in the field-of-view (FOV). The scanned sample has the maximum size of a voxel so that the calibration measurements have relatively poor signal-to-noise ratio (SNR). In this paper, we present the coded calibration scene (CCS) framework, where we place multiple MNP samples inside the FOV in a random or pseudo-random fashion. Taking advantage of the sparsity of the SM, we reconstruct the SM by solving a convex optimization problem with alternating direction method of multipliers using CCS measurements. We analyze the effects of filling rate, number of measurements, and SNR on the SM reconstruction using simulations and demonstrate different implementations of CCS for practical realization. We also compare the imaging performance of the proposed framework with that of a standard compressed sensing SM reconstruction that utilizes a subset of calibration measurements from a single MNP sample. The results show that CCS significantly reduces calibration time while increasing both the SM reconstruction and image reconstruction performances.


Assuntos
Imageamento por Ressonância Magnética/métodos , Nanopartículas de Magnetita/química , Processamento de Sinais Assistido por Computador , Algoritmos , Calibragem , Simulação por Computador , Imagens de Fantasmas , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA