Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Knee Surg Sports Traumatol Arthrosc ; 31(4): 1247-1266, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34601628

RESUMO

PURPOSE: Metallic resurfacing implants have been developed for the treatment of early, small, condylar and trochlear osteoarthritis (OA) lesions. They represent an option for patients who do not fulfill the criteria for unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA) or are too old for biological treatment. Although clinical evidence has been collected for different resurfacing types, the in vivo post-operative knee kinematics remain unknown. The present study aims to analyze the knee kinematics in subjects with patient-specific episealer implants. This study hypothesized that patient-specific resurfacing implants would lead to knee kinematics close to healthy knees, resulting in medial pivot and a high degree of femoral rollback during flexion. METHODS: Retrospective study design. Fluoroscopic analysis during unloaded flexion-extension and loaded lunge was conducted at > 12 months post-surgery in ten episealer knees, and compared to ten healthy knees. Pre- and post-operative clinical data of the episealer knees were collected using a visual analog scale (VAS), the EQ 5d Health, and the Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaires. RESULTS: A consistent medial pivot was observed in both episealer and healthy knees. Non-significant differences were found in the unloaded (p = 0.15) and loaded (p = 0.51) activities. Although lateral rollback was observed in both groups, it was significantly higher for the episealer knees in both the unloaded (p = 0.02) and loaded (p = 0.01) activities. Coupled axial rotation was significantly higher in the unloaded (p = 0.001) but not in the loaded (p = 0.06) activity in the episealer knees. Improved scores were observed at 1-year post-surgery in the episealer subjects for the VAS (p = 0.001), KOOS (p = 0.001) and EQ Health (p = 0.004). CONCLUSION: At 12 month follow-up, a clear physiological knee kinematics pattern of medial pivot, lateral femoral rollback and coupled axial external femoral rotation during flexion was observed in patients treated with an episealer resurfacing procedure. However, higher femoral rollback and axial external rotation in comparison to healthy knees was observed, suggesting possible post-operative muscle weakness and consequent insufficient stabilization at high flexion.


Assuntos
Prótese do Joelho , Osteoartrite do Joelho , Humanos , Estudos Retrospectivos , Projetos Piloto , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiologia , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular/fisiologia , Fenômenos Biomecânicos
2.
Eur Spine J ; 25(Suppl 4): 473-475, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27671274
3.
Anesth Analg ; 104(2): 442-7, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17242107

RESUMO

BACKGROUND: In this prospective, randomized, double-blind trial we investigated the use of stimulating catheters in patients during and after shoulder surgery; functional improvement being the primary outcome measurement. METHODS: After eliciting an adequate muscular twitch at < or =0.5 mA nerve stimulation output, the perineural catheter was advanced either blindly (conventional catheter = CC group, n = 20) or guided by stimulation via the catheter (stimulating catheter = SC group, n = 20). A bolus of 40 mL prilocaine 1% and 10 mL ropivacaine 0.75% was injected, followed by a patient-controlled infusion of ropivacaine 0.2% (8 mL/h infusion rate, bolus 2 mL, lockout time 20 min). RESULTS: Onset of motor block was faster in the SC group, whereas sensory block did not differ between groups. Median pain scores on two postoperative days were equal. Improvement of the objective shoulder function score (Constant Murley Score) 6 wk postoperatively was enhanced to a clinically relevant extent in the SC group compared to the CC group (P < 0.01). CONCLUSIONS: We conclude that the use of a stimulating catheter results in a faster onset of motor block, unaltered postoperative pain, and a significantly improved functional outcome 6 wk after shoulder surgery.


Assuntos
Anestesia por Condução/métodos , Cateterismo/métodos , Dor Pós-Operatória/terapia , Recuperação de Função Fisiológica/fisiologia , Ombro/cirurgia , Adulto , Anestesia por Condução/instrumentação , Plexo Braquial/fisiologia , Plexo Braquial/cirurgia , Cateterismo/instrumentação , Método Duplo-Cego , Estimulação Elétrica/instrumentação , Estimulação Elétrica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Bloqueio Nervoso/instrumentação , Bloqueio Nervoso/métodos , Medição da Dor , Dor Pós-Operatória/fisiopatologia , Estudos Prospectivos , Ombro/fisiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA