Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Eur J Orthop Surg Traumatol ; 33(8): 3287-3297, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37286819

RESUMO

PURPOSE: Poor outcomes and high complication and reoperation rates have been reported with tension-band wiring (TBW) in the management of patellar fractures and particularly the comminuted ones. The purpose of this study was to investigate the functional outcomes and complication rates of patellar fractures managed with open reduction and internal fixation (ORIF) with a plate. METHODS: MEDLINE, EMCare, CINAHL, AMED and HMIC were searched, and the PRISMA guidelines were followed. Two independent reviewers extracted the data from the included studies and assessed them for the risk of bias. RESULTS: Plating of patellar fractures is associated with satisfactory range of movement (ROM) and postoperative function and low pain levels. We found a 10.44% complication rate and a low reoperation rate. Reoperations were mainly performed for metalwork removal. CONCLUSION: ORIF with plating of patellar fractures is a safe alternative in the management of patellar fractures and may be associated with a lower complication and reoperation rate compared to TBW. Future randomized prospective studies are needed to validated the results of the present systematic review.


Assuntos
Fraturas Ósseas , Fraturas Cominutivas , Traumatismos do Joelho , Humanos , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Traumatismos do Joelho/cirurgia , Fraturas Cominutivas/cirurgia , Reoperação , Estudos Retrospectivos , Patela/cirurgia
2.
J Arthroplasty ; 32(5): 1679-1683, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28159422

RESUMO

BACKGROUND: The R3 acetabular system used with its metal liner has higher revision rates when compared to its ceramic and polyethylene liner. In June 2012, the medical and healthcare products regulatory agency issued an alert regarding the metal liner of the R3 acetabular system. METHODS: Six retrieved R3 acetabular systems with metal liners underwent detailed visual analysis using macroscopic and microscopic techniques. RESULTS: Visual analysis discovered corrosion on the backside of the metal liners. There was a distinct border to the areas of corrosion that conformed to antirotation tab insertions on the inner surface of the acetabular shell, which are for the polyethylene liner. Scanning electron microscopy indicated evidence of crevice corrosion, and energy-dispersive X-ray analysis confirmed corrosion debris rich in titanium. CONCLUSION: The high failure rate of the metal liner option of the R3 acetabular system may be attributed to corrosion on the backside of the liner which appear to result from geometry and design characteristics of the acetabular shell.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril , Prótese de Quadril , Quadril/cirurgia , Próteses Articulares Metal-Metal , Metais/química , Polietileno/química , Idoso , Cerâmica , Corrosão , Feminino , Humanos , Masculino , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Titânio/química
3.
Clin Orthop Relat Res ; 473(12): 3770-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25981716

RESUMO

BACKGROUND: Mid-head resection total hip resurfacing arthroplasty was promoted as an alternative to traditional total hip resurfacing for patients with poor femoral head bone quality or abnormal femoral head morphology, because those patients are at high risk of failure with traditional total hip resurfacing. It is a large-headed metal-on-metal device that uses a short, bone-conserving stem. Good performance of the implant has been reported at short-term followup, but no information on the implant performance in the mid- or long-term is available. QUESTIONS/PURPOSES: In this study, we report (1) on the mid-term implant survivorship and hip scores in a single nondesigner surgeon series. Because of the occurrence of femoral neck osteolysis and pseudotumor in a subgroup of patients, we also investigated the following: (2) Were there any preoperative parameters that are associated with osteolysis? (3) Could we differentiate the osteolysis group from the others on the basis of implant component sizes, positions, and radiologic parameters? (4) Could we differentiate the osteolysis group from the others on the basis of metal ion levels? METHODS: Between 2006 and 2011, one surgeon performed a total of 49 Birmingham Mid-head Resection total hip resurfacing arthroplasties in 47 patients. The general indications for this procedure were young patients who were considered suitable for hip resurfacing arthroplasty but had avascular necrosis, large cysts, or severe deformity of the femoral head. Clinical followup including Oxford Hip Score (OHS) and UCLA hip scores were available preoperatively and at a mean of 6 years (range, 3-8 years) on all patients (100%), radiographic followup on 45 of 47 (96%), MRIs on 18 (38%), and metal ion levels on 37 (79%). Mean age at surgery was 50 years. Spearman's correlation was used to test the association between femoral neck osteolysis and preoperative parameters, implant component sizes and positions, and blood metal ion levels. RESULTS: We found 100% survival. Patients' median OHS was 46 of 48 (range, 35-48) and UCLA 8 of 10 (range, 4-10). However, 16% of the hips (seven of 45) demonstrated osteolysis in the femoral neck. Of the preoperative parameters, the osteolysis was associated with low weight (r = -0.337, p = 0.031) and to a lesser degree with female sex (r = 0.275, p = 0.067). Radiologically, the osteolysis was strongly associated with the presence of a pseudotumor on MRI (r = 0.663, p = 0.004). We could not differentiate the osteolysis group from the rest of the cohort on the basis of the implant sizes or radiographic implant component positions. The cohort's median whole blood cobalt was 1.77 ppb (range, 0.18-10.27 ppb) and chromium 1.88 ppb (range 0.36-10.09 ppb). There was no difference in the metal ion levels between the osteolysis group and the rest of the cohort. CONCLUSIONS: The high rate of silently developing femoral neck osteolysis associated with this implant is concerning and is expected to cause a high rate of failure at longer followup. We have instituted a program of annual clinical and radiologic followup for this group of patients. We have stopped implanting this device and recommend against its use. LEVEL OF EVIDENCE: Level IV, therapeutic study.


Assuntos
Artroplastia de Quadril/instrumentação , Cabeça do Fêmur/cirurgia , Articulação do Quadril/cirurgia , Prótese de Quadril , Osteólise/etiologia , Falha de Prótese , Adulto , Idoso , Artroplastia de Quadril/efeitos adversos , Fenômenos Biomecânicos , Feminino , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/fisiopatologia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Metais , Pessoa de Meia-Idade , Osteólise/diagnóstico , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
4.
J Arthroplasty ; 30(9): 1652-6, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25890504

RESUMO

Numerous studies have reported on corrosion at the modular head taper, however less is known about the interface between the metal shell and liner of modular cups. This study examined the backside of a series of metal modular cup liners of two designs (DePuy Pinnacle and Smith & Nephew R3), retrieved from 67 patients. Visual inspection found evidence of corrosion in virtually all liners, with the engaging rim surface significantly more corroded than the polar regions (P<0.001). EDX confirmed that black surface deposits were chromium rich corrosion debris, while SEM analysis revealed considerable pitting in the vicinity of the black debris. The R3 liners were significantly more corroded that the Pinnacles (P<0.001); this may help to explain the higher revision rates of this design.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Falha de Prótese , Reoperação/instrumentação , Adulto , Idoso , Artroplastia de Quadril/métodos , Ligas de Cromo , Corrosão , Feminino , Humanos , Masculino , Metais , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Ossos Pélvicos/ultraestrutura , Desenho de Prótese
5.
JBJS Case Connect ; 14(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38870317

RESUMO

CASE: A patient underwent revision of a total knee replacement to a cementless rotating-hinge prosthesis. The femoral component became loose, but due to the patient's frailty and cognitive decline, revision was not performed. Subsequently, the yoke failed, dissociating the femoral and tibial components, necessitating a single-stage revision. CONCLUSION: This case underlines the need for robust fixation of components of rotating-hinge knee replacements to avoid mechanical failures. It contributes valuable insights to the limited literature on yoke failure in total knee arthroplasty, emphasizing the importance of implant design, patient selection, and surgical technique to prevent such complications.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Falha de Prótese , Idoso , Humanos , Artroplastia do Joelho/métodos , Artroplastia do Joelho/instrumentação , Desenho de Prótese , Reoperação
6.
J Exp Orthop ; 11(3): e12067, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39011084

RESUMO

Purpose: Obesity is prevalent, with nearly one-third of the world's population being classified as obese. In patients with high body mass index (BMI)/body mass undergoing total knee arthroplasty (TKA), there is an increase in strain placed on the implant fixation interfaces. As such, component fixation is a potential concern when performing TKA in the obese patient. To address the growing concerns around the longevity of implant fixation, some have advocated cementless over cemented fixation. However, there is no clear consensus on whether a cementless fixation has more favourable outcomes. The aim of this paper was to present a systematic review and meta-analysis of the existing evidence to establish if cementless TKA has a lower rate of aseptic loosening in high BMI patients when compared to cemented TKA procedures. Methods: A systematic review was performed, and the following databases Medical Literature Analysis and Retrieval System Online (1946 to date), PubMed (1966 to date) and Excerpta Medica Database (1974 to date) were searched. All studies comparing cementless to cemented TKA in patients with BMI > 30 were considered. Meta-analysis compared aseptic loosening and all-cause revision between cemented and uncemented implant use in BMI > 30 patients. Results: The search returned 91 articles in total; after duplicates were removed, the yield was 44 studies. Of the remaining studies that were assessed, three studies met the inclusion criteria for meta-analysis. The pooled odds ratio for all-cause revisions was 0.17 (95%, 0.08-0.36) in favour of uncemented implants (p < 0.01). The pooled odds ratio for aseptic loosening was 0.15 (95% confidence interval, 0.02-0.90) in favour of uncemented implants (p = 0.04). Conclusions: Meta-analysis demonstrated a significant decrease in all-cause revisions and revisions for aseptic loosening when using uncemented fixation in high BMI patients when compared to the use of cemented implants. Level of Evidence: The level of evidence is 1 for our systematic review.

7.
Arthroplast Today ; 27: 101397, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38882466

RESUMO

Background: Stiffness is a common complication following total knee arthroplasty. Manipulation under anesthesia (MUA) is an intervention that can potentially improve range of motion (ROM). Continuous passive motion (CPM) therapy has been utilized to enhance post-MUA ROM, but its effectiveness remains debated. This study assesses whether CPM therapy after MUA results in superior ROM outcomes compared to MUA alone. Methods: A retrospective analysis included patients undergoing MUA for stiff primary total knee arthroplasty between 2017 and 2022. Demographics and ROM data were collected. Patients were in 2 groups: those who received inpatient CPM post-MUA and those who received day-case MUA alone. Complications and further interventions were noted. Results: Of 126 patients, 39 underwent MUA only (day-case group), and 87 received CPM and MUA (inpatient group). Mean preoperative ROM was 69.4° (standard deviation [SD]:18.0°) and 73.9° (SD: 18.1°) for inpatient and day-case groups, respectively. Mean post-MUA ROM improved by 39.4° (SD: 17.7°) and 25.5° (SD: 11.1°) inpatient groups and day-case, respectively. The mean percentage of ROM gained at MUA maintained at final follow-up was 63.7% (40.8%) and 67.0% (47.5%) inpatient and day-case groups, respectively. Conclusions: This study found no advantage in the routine use of CPM post-MUA for stiff total knee replacement patients, suggesting it may not provide sustained ROM improvements compared to MUA alone. Cost-effectiveness and patient selection merit further investigation.

8.
Bone Jt Open ; 4(5): 357-362, 2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37195092

RESUMO

Aims: It is common practice for patients to have postoperative blood tests after total joint replacement (TJR). However, there have been significant improvements in perioperative care with arthroplasty surgery, and a drive to reduce the length of stay (LOS) and move towards day-case TJR. We should reconsider whether this intervention is necessary for all patients. Methods: This retrospective study included all patients who underwent a primary unilateral TJR at a single tertiary arthroplasty centre during a one-year period. Electronic medical records of 1,402 patients were reviewed for patient demographics, LOS, and American Society of Anesthesiologists (ASA) grade. Blood tests were examined to investigate the incidence of postoperative anaemia, electrolyte abnormalities, and incidence of acute kidney injury (AKI). Results: For total knee arthroplasties, preoperative (R = -0.22) and postoperative haemoglobin (R = 0.2) levels were both negatively correlated with LOS (p < 0.001). For all patients who had undergone a TJR, 19 patients (0.014%) required a blood transfusion postoperatively due to symptomatic anaemia. Risk factors identified were age, preoperative anaemia, and long-term aspirin use. Significant abnormal sodium levels were found in123 patients (8.7%). However, only 36 patients (2.6%) required intervening treatment. Risk factors identified were age, preoperative abnormal sodium level, and long-term use of non-steroidal anti-inflammatory drugs, angiotensin receptor blockers, and corticosteroids. Similarly, abnormal potassium levels were evident in 53 patients (3.8%), and only 18 patients (1.3%) required intervening treatment. Risk factors identified were preoperative abnormal potassium level, and long-term use of angiotensin-converting enzyme inhibitors and diuretics. The incidence of AKI was 4.4% (61 patients). Risk factors identified were age, increased ASA grade, preoperative abnormal sodium, and creatinine level. Conclusion: Routine blood tests after primary TJR is unnecessary for most patients. Blood tests should only be performed on those with identifiable risk factors such as preoperative anaemia and electrolyte abnormalities, haematological conditions, long-term aspirin use, and electrolyte-altering medications.

9.
Hip Int ; 32(5): 677-684, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33322929

RESUMO

BACKGROUND: Modularity of metal-on-metal (MoM) implants has come under scrutiny due to concerns regarding additional sources of metal debris. This study is a retrieval analysis of implants from the same manufacturer with the same MoM bearing surface. The difference between the implants was presence or absence of modular junctions. METHODS: This is a retrospective study of 31 retrieved implants from 31 patients who received a Conserve Wright Medical MoM hip prosthesis. The 31 implants consisted of 16 resurfacings and 15 implants with modular junctions; 4 conventional THAs and 11 modular-neck THAs. RESULTS: 43% of pre-revision MRI scans performed on resurfacing implants and 91% performed on the modular implants illustrated evidence of an adverse local tissue reaction. There was no difference in pre-revision blood metal ion levels or bearing surface wear between the resurfacings and modular implants. The neck-head tapers of the modular group showed low levels of material loss. However, the neck-stem tapers showed increased severity of corrosion and material loss. CONCLUSIONS: The modular implants had an increased incidence of adverse local tissue reaction. This could be related to the presence of modular junctions, particular the neck-stem junction which showed increased susceptibly to corrosion.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Corrosão , Prótese de Quadril/efeitos adversos , Humanos , Próteses Articulares Metal-Metal/efeitos adversos , Metais , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos
10.
Hip Int ; 31(1): 109-114, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31496282

RESUMO

BACKGROUND: Blood metal ion levels are used in the surveillance of metal-on-metal (MoM) hip implants. Modular implants contain an extra source of metal debris that may affect the ratio of metal ions in the blood. METHODS: This was a retrospective study of 503 patients with hip replacements made by a single manufacturer (Smith & Nephew, Warwick, UK) with the same bearing surface. There were 54 total hip arthroplasties, 35 Birmingham Mid-Head Resections and 414 hip resurfacings. Whole blood metal ion levels and their ratios were analysed to investigate the effect of a modular junction. RESULTS: The cobalt:chromium ratios were greater in the total hip arthroplasty group (mean 2.3:1) when compared to the resurfacings group (mean 1.3:1, p = <0.05) and Birmingham Mid-Head Resection group (mean 1.1:1, p = 0.11). CONCLUSIONS: This study demonstrated a trend for a higher cobalt:chromium ratio in patients with MoM total hip replacement that may be due to metal debris from the modular stem-head junction. Further work is required to correlate clinical data with retrieval analysis to confirm the effect of taper material loss on the cobalt:chromium ratio.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto/efeitos adversos , Prótese de Quadril/efeitos adversos , Humanos , Próteses Articulares Metal-Metal/efeitos adversos , Desenho de Prótese , Estudos Retrospectivos
12.
J Bone Joint Surg Am ; 94(4): e22, 2012 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-22336981

RESUMO

BACKGROUND: A large proportion of metal-on-metal hip arthroplasty failures are due to unexplained pain. The mechanism of failure has been thought to be associated with factors that increase material loss, including specific design features and surgical positioning of components. However, recent evidence suggests that there is not a simple dose-response relationship. An analysis of failed metal-on-metal hip arthroplasties involving a single design was performed in an attempt to help resolve this issue. Our aim was to identify the clinical and component variables associated with failure of metal-on-metal hip arthroplasties, particularly in patients undergoing revision arthroplasty because of unexplained hip pain, and to clarify the role of material loss. METHODS: We prospectively recruited fifty-five patients who were undergoing revision of a metal-on-metal Birmingham Hip Resurfacing System (BHR) arthroplasty (Smith & Nephew). We collected clinical data preoperatively, intraoperatively, and following the revision arthroplasty. Data included chromium and cobalt levels in whole blood, which were measured with use of inductively coupled plasma mass spectrometry (ICPMS), and component orientation, which was typically measured with use of computed tomography (CT) scans. The wear of the retrieved components was also quantified postoperatively. All parameters were compared with those in a comparable group of patients with a well-functioning BHR arthroplasty. RESULTS: Sixty-nine percent of the patients who underwent revision arthroplasty did so following a diagnosis of unexplained hip pain. When compared with patients with a well-functioning arthroplasty, patients who underwent revision arthroplasty had a significantly higher acetabular cup inclination angle (p < 0.01), a significantly smaller femoral head diameter (p < 0.01), and significantly higher blood cobalt and chromium ion levels (p < 0.01). However, almost 50% of the patients who underwent revision arthroplasty had blood metal ion levels below the clinical threshold of 7 ppb and low component wear rates of <5 µm/year. CONCLUSIONS: In a large number of patients with unexplained hip pain leading to revision of a metal-on-metal hip arthroplasty, the acetabular cup orientation was satisfactory and the material loss rate was low. We suspect that patient-specific factors may have been responsible for the failure in a large proportion of these patients.


Assuntos
Prótese de Quadril , Falha de Prótese , Adolescente , Adulto , Idoso , Cromo/sangue , Cobalto/sangue , Feminino , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Dor/sangue , Dor/etiologia , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA