Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Dairy Sci ; 107(8): 6052-6064, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38554821

RESUMO

The use of sensor-based measures of rumination time as a parameter for early disease detection has received a lot of attention in scientific research. This study aimed to assess the accuracy of health alerts triggered by a sensor-based accelerometer system within 2 different management strategies on a commercial dairy farm. Multiparous Holstein cows were enrolled during the dry-off period and randomly allocated to conventional (CON) or sensor-based (SEN) management groups at calving. All cows were monitored for disorders for a minimum of 10 DIM following standardized operating procedures (SOP). The CON group (n = 199) followed an established monitoring protocol on the farm. The health alerts of this group were not available during the study but were later included in the analysis. The SEN group (n = 197) was only investigated when the sensor system triggered a health alert, and a more intensive monitoring approach was implemented according to the SOP. To analyze the efficiency of the health alerts in detecting disorders, the sensitivity (SE) and specificity (SP) of health alerts were determined for the CON group. In addition, all cows were divided into 3 subgroups based on their health status and the status of the health alerts in order to retrospectively compare the course of rumination time. Most health alerts (87%, n = 217) occurred on DIM 1. For the confirmation of diagnoses, health alerts showed SE and SP levels of 71% and 47% for CON cows. In SEN cows, SE of 71% and 75% and SP of 48% and 43% were found for the detection of ketosis and hypocalcemia, respectively. The rumination time of the subgroups was affected by DIM and the interaction between DIM and the status of health alert and health condition.


Assuntos
Parto , Animais , Bovinos , Feminino , Doenças dos Bovinos/diagnóstico , Indústria de Laticínios/métodos , Gravidez , Lactação
2.
J Dairy Sci ; 105(7): 6327-6338, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35525619

RESUMO

The objectives of this study were (1) to characterize the interindividual variation in the relationship between antepartum (ap) backfat thickness (BFT) and subsequent BFT loss during early lactation in a large dairy herd using cluster analysis; (2) to compare the serum concentrations of metabolites (nonesterified fatty acids, ß-hydroxybutyrate), metabolic hormones (leptin and adiponectin), and an inflammatory marker (haptoglobin) among the respective clusters; and (3) to compare lactation performance and uterine health status in the different clusters. An additional objective was (4) to investigate differences in these serum variables and in milk yield of overconditioned (OC) cows that differed in the extent of BFT loss. Using data from a large study of 1,709 multiparous Holstein cows, we first selected those animals from which serum samples and BFT results (mm) were available at d 25 (±10) ap and d 31 (±3 d) postpartum (pp). The remaining 713 cows (parity of 2 to 7) were then subjected to cluster analysis: different approaches based on the BFT of the cows were performed. K-means (unsupervised machine learning algorithm) clustering based on BFT-ap alone identified 5 clusters: lean (5-8 mm BFT, n = 50), normal (9-12 mm, n = 206), slightly fat (SF; 13-16 mm, n = 203), just fat (JF; 16-22 mm, n = 193), and very fat (VF; 23-43 mm, n = 61). Clustering by difference between BFT-ap and BFT-pp (ΔBFT) also revealed 5 clusters: extreme loss (17-23 mm ΔBFT, n = 16), moderate loss (9-15 mm, n = 119), little loss (4-8 mm, n = 326), no loss (0-3 mm, n = 203), and gain (-8 to -1 mm, n = 51). Based on the blood variables measured, our results confirm that cows with greater BFT losses had higher lipid mobilization and ketogenesis than cows with less BFT loss. The serum variables of cows that gained BFT did not differ from normal cows. Milk yield was affected by the BFT-ap cluster, but not by the ΔBFT cluster. Cows categorized as VF had lesser milk yield than other clusters. We further compared the OC cows that had little or no BFT loss (i.e., 2% of VF, 12% of JF, and 31% of SF, OC-no loss, n = 85) with the OC cows that lost BFT (OC-loss, n = 135). Both NEFA and BHB pp concentrations and milk yield were greater in OC-loss cows compared with the OC-no loss cows. The serum concentration of leptin ap was greater in OC-loss than in the OC-no loss cows. Overall, OC cows lost more BFT than normal or lean cows. However, those OC cows with a smaller loss of BFT produced less milk than OC cows with greater losses.


Assuntos
Lactação , Leptina , Ácido 3-Hidroxibutírico , Animais , Bovinos , Dieta/veterinária , Ácidos Graxos não Esterificados , Feminino , Leptina/metabolismo , Leite/metabolismo , Paridade , Período Pós-Parto , Gravidez
3.
J Dairy Sci ; 104(5): 6013-6019, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33663846

RESUMO

One of the most important diseases in calves worldwide is neonatal calf diarrhea (NCD), which impairs calf welfare and leads to economic losses. The aim of this study was to test whether the activity patterns of calves can be used as early indicators to identify animals at risk for suffering from NCD, compared with physical examination. We monitored 310 healthy female Holstein-Friesian calves on a commercial dairy farm immediately after birth, equipped them with an ear tag-based accelerometer (Smartbow, Smartbow GmbH), and conducted daily physical examinations during the first 28 d of life. The Smartbow system captured acceleration data indicative of standing and lying periods and activity levels (active and inactive), shown as minutes per hour. We categorized calves as diarrheic if they showed fecal scores of ≥3 on a 4-point scale on at least 2 consecutive days. Incidence of diarrhea was 50.7% (n = 148). A mixed logistic regression model showed that lying [odds ratio (OR) = 1.19], inactive (OR = 1.14), and active (OR = 0.92) times, 1 d before clinical identification of diarrhea (d -1), were associated with the odds of diarrhea occurring on the subsequent day. Receiver operating characteristics curve showed that lying time at d -1 was a fair predictor for diarrhea on the subsequent day (area under curve = 0.69). Average lying time on d -1 was 64.8 min longer in diarrheic calves compared with their controls. Median lying and inactive times decreased, and active time increased with age over the study period. The 24-h pattern of behavior indices based on the output of the Smartbow system followed periods of resting and active times, and showed that between 2200 h and 0600 h, calves spent the greatest percentage of time lying and inactive. These results showed that the accelerometer system has the potential to detect early indicators associated with NCD. In future studies, additional data for the development and testing of calf- and event-specific algorithms (e.g., for detecting milk intake, playing behavior) should be collected, which might further improve the early detection of diarrhea in calves.


Assuntos
Comportamento Animal , Doenças dos Bovinos , Acelerometria/veterinária , Animais , Bovinos , Doenças dos Bovinos/diagnóstico , Doenças dos Bovinos/epidemiologia , Diarreia/veterinária , Fezes , Feminino
4.
J Dairy Sci ; 102(8): 7453-7458, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31178193

RESUMO

Several factors have been reported to influence colostrum quality (immunoglobulin concentration). To date, knowledge of the influence of climatic factors in association with other potential influencing factors on colostrum quality is scarce. Associated influential factors are parity, body condition score, length of dry period, ration fed ante partum (AP), ß-hydroxybutyrate postpartum (PP), milk yield, milk fat and protein, as well as somatic cell counts from previous and current lactation. The objective of the present study was to examine the effect of barn climate and the aforementioned factors on colostrum quality. Data were collected from 1,381 multiparous Holstein Friesian cows kept on one dairy farm over a period of one year (August 2014 to August 2015). Colostrum was harvested on farm within 1 h PP. The quantity and quality of first colostrum (estimated by Brix refractometry) were recorded for each cow. Additional data recorded were parity, body condition score at drying off, length of dry period, ration fed AP, milk yield data from previous and current lactation, milk somatic cell counts, and ß-hydroxybutyrate PP. During the study period, temperature and humidity were recorded in the barn every hour, and temperature-humidity-index (THI) was calculated. Linear regression was performed with colostrum quality as the dependent variable. In the final model, colostrum quantity (L), length of dry period, parity, and climatic factors (specifically, median humidity in the 3rd week AP and hours with THI ≥72 in the last 14 and 21 d AP, respectively) were significant. Colostrum quality improved with parity and length of dry period and decreased with colostrum quantity, humidity, and hours with a THI ≥72. A classification and regression tree analysis revealed that colostrum quantity was the most important factor in this model [normalized importance (NI) 100%]. Parity (NI 42.7%), length of dry period (NI 37.1%), and climatic factors (NI 0.4 to 1.9%) followed with decreasing importance. These results indicate that the most important factors for colostrum quality (i.e., colostrum quantity and parity) may not be influenced by management. The 2 factors that can be influenced by management [i.e., length of dry period and THI (e.g., by cooling)], were quantitatively of minor importance compared with the other 2 factors. Further studies are necessary to determine whether changing these factors can improve colostrum quality significantly.


Assuntos
Bovinos , Colostro , Abrigo para Animais , Umidade , Temperatura , Ácido 3-Hidroxibutírico/metabolismo , Animais , Colostro/metabolismo , Feminino , Lactação , Modelos Lineares , Leite/metabolismo , Período Pós-Parto , Gravidez
5.
J Dairy Sci ; 101(7): 6437-6442, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29705429

RESUMO

Pulse oximetry is a well-established technique in human and veterinary medicine. In farm animals, it could also be a useful tool for the detection of critical conditions relating to oxygen supply and the cardiovascular system. Among other uses, an innovative application could be the monitoring of fetuses during birth. This could help in the early identification of critical situations and support farmers and veterinarians in their decision to start obstetric or life-support interventions. Until now, however, its use in ruminant medicine was still limited to experimental applications. The objective of this study was to evaluate the accuracy of the Radius-7 Wearable Pulse CO-Oximeter (Masimo Corporation, Irvine, CA) for monitoring vital parameters in newborn calves. All measurements were conducted on animals in the lying down position. The sensor of the pulse oximeter was placed in the interdigital space of the calves' front legs and fixed with a homemade latex hoof cover. The pulsoximetric measurements of arterial oxygen saturation (SpO2) in 40 newborn calves were compared with the corresponding results (SaO2) from a portable blood gas analyzer (VetScan iStat1, Abaxis Inc., Union City, CA), which served as the reference. For this, an arterial blood sample was taken from the medial intermediate branch of the caudal auricular artery. In addition, the pulse rate was measured in 10 calves aged between 0 and 7 d with the pulse oximeter and simultaneously with a heart rate belt (Polar Equine Belt, Polar Electro Oy, Kempele, Finland) to determine their level of agreement. Spearman correlation coefficient for oxygen saturation was 93.8% for the pulse oximeter and the blood gas analyzer, and 97.7% for the pulse rate measured with the pulse oximeter and the heart rate belt. Bland-Altman plots revealed an overestimation of SaO2 by 2.95 ± 6.39% and an underestimation of the pulse rate by -0.41 ± 3.18 beats per minute compared with the corresponding reference methods. In summary, the pulse oximeter is suitable for continuous monitoring of arterial oxygen saturation and pulse in newborn Holstein Friesian calves. For practical use, purpose-built technical equipment is required to attach the sensor to the calves' legs.


Assuntos
Gasometria/veterinária , Bovinos , Frequência Cardíaca/fisiologia , Oximetria/veterinária , Oxigênio/sangue , Animais , Gasometria/instrumentação , Gasometria/métodos , Humanos , Oximetria/instrumentação , Oximetria/métodos
6.
J Dairy Sci ; 101(4): 3398-3411, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29395141

RESUMO

The objective of this study was to evaluate the ear-tag-based accelerometer system Smartbow (Smartbow GmbH, Weibern, Austria) for detecting rumination time, chewing cycles, and rumination bouts in indoor-housed dairy cows. For this, the parameters were determined by analyses of video recordings as reference and compared with the results of the accelerometer system. Additionally, we tested the intra- and inter-observer reliability as well as the agreement of direct cow observations and video recordings. Ten Simmental dairy cows in early lactation were equipped with 10-Hz accelerometer ear tags and kept in a pen separated from herd mates. A total mixed ration was fed twice a day via a roughage intake control system. During the study, cows' rumination and other activities were directly observed for 20 h by 2 trained observers. Additionally, cows were video recorded for 19 d, 24 h a day. After exclusion of unsuitable videos, 2,490 h of cow individual 1-h video sequences were eligible for further analyses. Out of this, one hundred 1-h video sequences were randomly selected and visually and manually classified by a trained observer using professional video analyses software. Based on these analyses, half of the data was used for development (based on data of 50-h video analyses) and testing (based on data of additional 50-h video analyses) of the Smartbow algorithms, respectively. Inter- and intra-observer reliability as well as the comparison of direct against video observations revealed in high agreements for rumination time and chewing cycles with Pearson correlation coefficients >0.99. The rumination time, chewing cycles, as well as rumination bouts detected by Smartbow were highly associated (r > 0.99) with the analyses of video recordings. Algorithm testing revealed in an underestimation of the average ± standard deviation rumination time per 1-h period by the Smartbow system of 17.0 ± 35.3 s (i.e., -1.2%), compared with visual observations. The average number ± standard deviation of chewing cycles and rumination bouts was overestimated by Smartbow by 59.8 ± 79.6 (i.e., 3.7%) and by 0.5 ± 0.9 (i.e., 1.6%), respectively, compared with the video analyses. In summary, the agreement between the Smartbow system with video analyses was excellent. From a practical and clinical point of view, the detected differences were negligible. However, further research is necessary to test the system under various field conditions and to evaluate the benefit of incorporating rumination data into herd management decisions.


Assuntos
Acelerometria/veterinária , Mastigação , Monitorização Fisiológica/veterinária , Acelerometria/instrumentação , Animais , Áustria , Bovinos , Orelha , Feminino , Lactação , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Gravação em Vídeo
7.
J Dairy Sci ; 100(7): 5717-5723, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28478011

RESUMO

The primary objective of this study was to evaluate the repeatability of measurements of ß-hydroxybutyrate (BHB) concentrations in capillary blood obtained from minimal-invasive puncturing of different sites at the external vulva skin of dairy cows. A total of 240 multiparous cows sampled once within 21 d in milk were enrolled in the study. Capillary blood samples were obtained from the right and left labium of the external vulva skin and additionally from a site close to the first puncture. Samples were analyzed by using an electronic hand-held device [FreeStyle Precison Neo (FSP-Neo), Abbott GmbH & Co., Wiesbaden, Germany)]. Additionally, samples from a coccygeal vessel were analyzed as reference in a laboratory. Mean deviations (± standard deviation) between the 3 capillary sampling sites ranged from 0.01 ± 0.14 (left vs. right labium) to 0.02 ± 0.13 mmol/L (left or right labium vs. additional site). The BHB concentrations in capillary blood compared with the reference showed a mean deviation of 0.14 ± 0.18 mmol/L. The Spearman correlation coefficient between BHB concentrations in capillary blood and coccygeal blood was 85.4%. Mixed model analyses showed no significant effect of sampling site or squeezing the skin during sampling procedures on the differences toward the reference. Based on laboratory BHB concentrations of ≥1.2 and ≥1.4 mmol/L, respectively, the prevalence of hyperketonemia was 10.4 (n = 25) and 5.0% (n = 12). Thresholds to detect hyperketonemia with the FSP-Neo were optimized by receiver operating characteristic analyses. Based on a laboratory BHB concentration of ≥1.2 mmol/L thresholds were determined as 1.1 (left labium, 2nd puncture) and 1.0 mmol/L (right labium), with sensitivities between 94 and 99% and specificities between 89 and 97%. Based on a serum BHB concentration of 1.4 mmol/L, receiver operating characteristic analyses resulted in optimized cutoffs of 1.4 mmol/L for all sampling sites at the vulva, with sensitivities of 100% and specificities between 96 and 99%. In conclusion, vulvar capillary blood is suitable for accurate measuring of BHB concentrations by using the FSP-Neo. After adjusting the thresholds, the FSP-Neo provides very good test characteristics independent of the capillary sampling site or squeezing the skin and allows a practical and reliable screening tool for dairy cows.


Assuntos
Ácido 3-Hidroxibutírico/sangue , Doenças dos Bovinos/diagnóstico , Cetose/veterinária , Vulva/irrigação sanguínea , Animais , Capilares , Bovinos , Feminino , Alemanha , Cetose/diagnóstico , Punções/veterinária , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
BMC Vet Res ; 12: 34, 2016 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-26911673

RESUMO

BACKGROUND: Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood sampling techniques have been introduced in which small amounts of blood are rapidly analysed using electronic hand-held devices. The objective of this study was to evaluate the suitability of capillary blood for blood glucose measurement in dairy cows using the hand-held devices FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini) and the WellionVet GLUCO CALEA, (WGC, MED TRUST). In total, 240 capillary blood samples were obtained from dry and fresh lactating Holstein-Friesian cows. Blood was collected from the skin of the exterior vulva by using a lancet. For method comparison, additional blood samples were taken from a coccygeal vessel and analyzed in a laboratory. Glucose concentrations measured by a standard laboratory method were defined as the criterion standard. RESULTS: The Pearson correlation coefficients between the glucose concentrations analyzed in capillary blood with the devices and the reference were 73% for the FSP, 81% for the GLX and 41% for the WGC. Bland-Altman plots showed biases of -18.8 mg/dL for the FSP, -11.2 mg/dL for the GLX and +20.82 mg/dL for the WGC. The optimized threshold determined by a Receiver Operating Characteristics analysis to detect hyperglycemia using the FSP was 43 mg/dL with a sensitivity (Se) and specificity (Sp) of 76 and 80%. Using the GLX and WGC optimized thresholds were 49 mg/dL (Se = 92%, Sp = 85%) and 95 mg/dL (Se = 39%, Sp = 92%). CONCLUSIONS: The results of this study demonstrate good performance characteristics for the GLX and moderate for the FSP to detect hyperglycemia in dairy cows using capillary blood. With the study settings, the WGC was not suitable for determination of glucose concentrations.


Assuntos
Técnicas Biossensoriais/veterinária , Glicemia/análise , Coleta de Amostras Sanguíneas/veterinária , Bovinos/sangue , Animais , Técnicas Biossensoriais/instrumentação , Coleta de Amostras Sanguíneas/instrumentação , Capilares , Feminino , Sensibilidade e Especificidade
9.
J Dairy Sci ; 99(4): 2438-2452, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26874416

RESUMO

The objective of this review is to provide the reader with an overview of thermoregulatory mechanisms and the influence of climatic conditions in different housing systems on the development, performance, and health of calves. Thermic stress is observed in association with extreme temperatures and large temperature variations, but other variables such as relative humidity and wind speed can also contribute to thermic stress. Thermoregulation in calves is similar to that in adult cattle, but especially dystocial calves are more prone to heat loss. Heat or cold stress results in direct economic losses because of increased calf mortality and morbidity, as well as indirect costs caused by reduced weight gain, performance, and long-term survival. The climatic conditions in a variety of housing systems, associated health problems, and strategies to mitigate thermic stress are discussed in this review. The goal of housing is to alleviate the effect of climate on calves and provide a microclimate. Adequate ventilation with fresh air is essential to reduce respiratory disease. Common practices such as raising calves in individual outdoor enclosures have been challenged lately. Recent research seeks to evaluate the suitability of group housing under practical, economic, and animal welfare considerations. Limited results for reducing thermic stress can be achieved by simple measures such as shades or shelter, but additional heat or cold stress relieving strategies can be required depending on the housing system.


Assuntos
Bem-Estar do Animal , Regulação da Temperatura Corporal , Bovinos/fisiologia , Abrigo para Animais , Animais , Animais Recém-Nascidos , Bovinos/crescimento & desenvolvimento , Temperatura Baixa , Temperatura Alta , Estresse Fisiológico , Temperatura , Ventilação
10.
J Dairy Sci ; 99(9): 7362-7369, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27289156

RESUMO

The primary objective of the present study was to test whether capillary blood obtained by puncturing the skin of an ear with a minimal invasive lancet technique is able to detect hyperketonemia (HYK) in dairy cows. Furthermore, test characteristics of a new available handheld device, the FreeStyle Precision Neo (FSP-Neo, Abbott GmbH & Co. KG, Wiesbaden, Germany) for determination of ß-hydroxybutyrate (BHB) concentrations in bovine blood were evaluated by comparing the measurements with a laboratory reference. The BHB concentration was determined with the FSP-Neo device in 720 capillary blood samples from 3 different sampling sites (left, right ear, and repeated measurement) and in 240 samples from a coccygeal vessel. The concentration of BHB in serum harvested from the coccygeal blood samples was analyzed at the laboratory and was used as reference. The Spearman correlation coefficient (ρs) between the BHB concentrations in capillary blood measured with the handheld device and the reference test was between 0.76 and 0.81. Using capillary blood, the mean ± standard deviation BHB difference compared with the reference test was 0.20±0.47 mmol/L for all 3 sampling locations at the ears. The receiver operating characteristic analyses for the FSP-Neo device resulted in an optimized threshold for the detection of subclinical ketosis (SCK) in capillary blood of 1.3 mmol/L (left and right ear) and 1.2 mmol/L (repeated measurements). Applying these adjusted threshold sensitivities (Se) for all 3 capillary sampling sites at the ear were 100%, and specificities (Sp) ranged between 93 and 94%. Hence, we conclude that all sampling locations were suitable to identify cows suffering from SCK. The reference test compared with BHB measurements in coccygeal blood resulted in a ρs of 0.92 with a mean ± standard deviation of 0.02±0.21 mmol/L. The receiver operating characteristic analyses for the FSP-Neo device resulted in an optimized threshold for the detection of SCK in coccygeal blood of 1.1 mmol/L, with a corresponding Se and Sp of 100 and 95%, respectively. Because capillary blood is easily achievable from an ear, particularly if animals are fixed in headlocks for routine checkups, this technique is considered as an additional minimally invasive method for the identification of dairy cows suffering from HYK.


Assuntos
Ácido 3-Hidroxibutírico/sangue , Doenças dos Bovinos/sangue , Eletrônica/instrumentação , Cetose/veterinária , Animais , Capilares , Bovinos , Feminino , Cetose/sangue , Transtornos Puerperais/sangue , Transtornos Puerperais/veterinária , Curva ROC , Sensibilidade e Especificidade
11.
N Z Vet J ; 64(5): 263-7, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27192928

RESUMO

AIMS: To evaluate two different hydrometers and an optical and a digital Brix refractometer for the assessment of bovine colostrum quality, in terms of accuracy and precision compared with the measurement of IgG concentrations using radial immunodiffusion (RID), and to evaluate the reliability and repeatability of the Brix refractometers. METHODS: To determine reliability and repeatability, 145 colostrum samples were tested by two independent observers twice, using the optical and digital Brix refractometers. A further 193 colostrum samples from Holstein cows were collected on one commercial dairy farm at first milking and tested with two hydrometers and an optical and digital Brix refractometer. An aliquot of each sample was frozen for RID measurement of IgG concentrations and samples were classified as poor (≤50 g IgG/L) or good (>50 g IgG/L) quality colostrum. Intraclass correlation coefficients (ICC) were used to determine inter- and intra-observer reliability and repeatability. Optimised cut-off values for the four devices were determined using receiver operating characteristics (ROC) analysis with the RID results as the reference. Using these cut-offs, sensitivities and specificities for determining good quality colostrum were calculated. RESULTS: The ICC for inter-observer reliability was 0.98 for the optical Brix refractometer, and for intra-observer repeatability was 0.97 and 0.98 for the optical and the digital Brix refractometers, respectively. For the 193 colostrum samples, 67 (34.7%) had concentrations of IgG ≤50 g/L determined by RID. Optimised cut-off values evaluated by ROC analysis were higher for all devices compared with manufacturer reference or previously published values. Using these values, the sensitivities for the two hydrometers, and the optical and the digital Brix refractometers were 0.73, 0.71, 0.56 and 0.79, respectively; specificities were 0.72, 0.61, 0.90 and 0.69, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: The Brix refractometers provided the most accurate assessment of colostrum quality of the devices evaluated, and demonstrated excellent precision in terms of repeatability. To provide optimal health for newborn calves, a sufficient intake of good quality colostrum is essential. The Brix refractometers provide rapid, convenient tools for classification of colostrum quality.


Assuntos
Colostro , Animais , Bovinos , Colostro/química , Colostro/imunologia , Indústria de Laticínios/instrumentação , Indústria de Laticínios/métodos , Imunodifusão/métodos , Imunodifusão/veterinária , Imunoglobulina G/análise , Refratometria/veterinária , Reprodutibilidade dos Testes
12.
J Dairy Sci ; 98(9): 6108-18, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26142854

RESUMO

The objective of this study was to evaluate the suitability of capillary blood obtained by a minimally invasive lancet technique to detect subclinical ketosis in 49 prepartum and 191 postpartum Holstein-Friesian cows using 3 different electronic hand-held devices [FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini), NovaVet (NOV, Nova Biomedical)]. The ß-hydroxybutyrate (BHBA) concentration in serum harvested from coccygeal blood samples was analyzed in a laboratory and used as a reference value. Capillary samples were obtained from the skin of the exterior vulva by using 1 of 3 different lancets. In all samples, the concentration of BHBA was immediately analyzed with all 3 hand-held devices used in random order. All lancets used in the study were eligible for capillary blood collection but differed in the total number of incisions needed. Spearman correlation coefficients between the BHBA concentrations in capillary blood and the reference test were highly significant with 83% for the FSP, 73% for the NOV, and 63% for the GLX. Using capillary blood, the FSP overestimated the mean BHBA concentration compared with the reference test (+0.08 mmol/L), whereas the GLX and NOV underestimated the mean concentration (-0.07 and -0.01 mmol/L). When a BHBA concentration of 1.2 mmol/L in serum was used to define subclinical ketosis, the corresponding analyses of receiver operating characteristics resulted in optimized thresholds for capillary blood of 1.1 mmol/L for the NOV and GLX devices, and of 1.0 mmol/L for the FSP. Based on these thresholds, sensitivities (Se) and specificities (Sp) were 89 and 84% for the NOV, 80 and 89% for the GLX, and 100 and 76% for the FSP. Based on a serum BHBA concentration of 1.4 mmol/L, analyses of receiver operating characteristics resulted in optimized cut-offs of 1.4 mmol/L for the FSP (Se 100%, Sp 92%), 1.3 mmol/L for the NOV (Se 80%, Sp 95%), and 1.1 mmol/L (Se 90%, Sp 85%) for the GLX. Using these optimized thresholds for the specific hand-held meters, no significant differences between the devices in Se and Sp to detect subclinical ketosis in coccygeal blood were observed. Calculated test characteristics for analyzing capillary blood using the hand-held devices were numerically smaller compared with blood obtained from a coccygeal vessel, but overlapping confidence intervals indicate no statistical difference between the origin of the sample. Hence, this procedure seems to be suitable for ketosis monitoring in dairy cows, but further validation with more data from different farms is recommended.


Assuntos
Ácido 3-Hidroxibutírico/sangue , Doenças dos Bovinos/diagnóstico , Cetose/veterinária , Animais , Infecções Assintomáticas , Bovinos , Indústria de Laticínios , Eletrônica/instrumentação , Feminino , Cetose/diagnóstico , Período Pós-Parto , Curva ROC , Sensibilidade e Especificidade
13.
J Dairy Sci ; 97(8): 5110-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24881793

RESUMO

Calf diarrhea is one of the most important problems in calf rearing on dairy farms worldwide. Besides pathogens, several noninfectious management factors, especially management around birth, colostrum management, calf housing, feeding, and hygiene are important in the pathogenesis of diarrhea. To date, few data are available concerning calf rearing management on small and medium-sized dairy farms that are typical for Austria and the alpine region. Consequently, the objectives of this case-control study were to evaluate routine calf management practices on Austrian dairy farms and to examine differences in management between farms with and without the presence of calf diarrhea to identify risk factors. Overall, 100 dairy farms were visited. Of these farms, 50 were chosen based on the history and presence of calf diarrhea (case farms). Another 50 farms with no presence of calf diarrhea were chosen to serve as a standard of comparison (control farms). On farms, management was evaluated by face-to-face interview, and health status and hygiene were surveyed. Several calf rearing management procedures were similar on all of the visited farms, especially in areas regulated by national and European law. These factors include colostrum management and feeding. Consequently, no influence of these factors on the appearance of calf diarrhea could be detected. In contrast, other areas such as hygiene measures differed between farms and showed a partial association with the presence of calf diarrhea on farm. Variables related to diarrhea on farm were farm size; that is, the number of cows on farm. Farms with diarrhea cases were larger (median 40 cows, interquartile range 24.5 to 64.0) compared with farms with no presence of diarrhea (median 28 cows, interquartile range 18.8 to 44.0). Other risk factors that influenced the presence of diarrhea were the presence of other farm animal species on the farm [odds ratio (OR) 26.89, 95% confidence interval (CI): 2.64 to 273.5], frequency of cleaning of the calving area (OR 0.12, 95% CI: 0.02 to 0.79), the placement of individual calf housings (barn vs. outdoors; OR 0.02, 95% CI: 0.00 to 0.47), and the presence of respiratory tract disease (OR 52.49, 95% CI: 1.26 to 2,181.83). The possible influence of these factors on the appearance of calf diarrhea should be considered when farmers are advised.


Assuntos
Animais Recém-Nascidos/fisiologia , Doenças dos Bovinos/epidemiologia , Bovinos/fisiologia , Colostro/fisiologia , Indústria de Laticínios/métodos , Diarreia/veterinária , Animais , Áustria/epidemiologia , Estudos de Casos e Controles , Doenças dos Bovinos/prevenção & controle , Diarreia/epidemiologia , Diarreia/prevenção & controle , Feminino , Razão de Chances , Gravidez , Fatores de Risco
14.
J Dairy Sci ; 97(3): 1388-99, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24440266

RESUMO

Metabolic disorders, especially hyperketonemia, are very common in dairy sheep. The whole-blood concentrations of ß-hydroxybutyrate (BHBA) and glucose can be determined by commercially available electronic hand-held devices, which are used in human medicine and for the detection of ketosis in dairy cows. The aim of this study was to evaluate the suitability of the hand-held device Precision Xceed (PX; Abbott Diabetes Care Inc., Abbott Park, IL) to detect hyperketonemia in ewes. An additional objective of this study was to evaluate the agreement between samples obtained by minimal invasive venipuncture of an ear vein and measurements of whole-blood samples from the jugular vein (vena jugularis, v. jug.). Blood samples taken from the v. jug. were collected from 358 ewes on 4 different farms. These samples and a blood drop obtained from an ear vein were analyzed simultaneously on farm with the PX. For method comparison, the samples obtained from the v. jug. were also analyzed by standard methods, which served as the gold standard at the Central Laboratory of the University of Veterinary Medicine Vienna, Austria. The correlation coefficients between the serum BHBA concentration and the concentrations measured with the hand-held meter in the whole blood from an ear vein and the v. jug. were 0.94 and 0.96, respectively. The correlation coefficients of plasma and whole-blood glucose concentration were 0.68 for the v. jug. and 0.47 for the ear vein. The mean glucose concentration was significantly lower in animals classified as hyperketonemic (BHBA ≥ 1.6 mmol/L) compared with healthy ewes. Whole-blood concentrations of BHBA and glucose measured with the PX from v. jug. showed a constant negative bias of 0.15 mmol/L and 8.4 mg/dL, respectively. Hence, a receiver operating characteristic analysis was performed to determine thresholds for the PX to detect hyperketonemia in ewes. This resulted in thresholds for moderate ketosis of BHBA concentrations of 0.7 mmol/L in blood from an ear vein and the v. jug. Cutoffs of 1.0 mmol/L (ear vein) and 1.1 mmol/L (v. jug.) BHBA were determined to detect animals at greater risk to develop severe hyperketonemia. Applying these thresholds, excellent test characteristics, with sensitivities of 1.00 for both samples and specificities of 0.98 for the ear vein and 0.97 for the v. jug. were determined. These results demonstrate that the PX is a useful tool for detection of hyperketonemia in ewes.


Assuntos
Ácido 3-Hidroxibutírico/sangue , Análise Química do Sangue/métodos , Glicemia/metabolismo , Cetose/sangue , Cetose/diagnóstico , Cetose/veterinária , Animais , Áustria , Análise Química do Sangue/veterinária , Coleta de Amostras Sanguíneas/métodos , Feminino , Curva ROC , Sensibilidade e Especificidade , Ovinos , Doenças dos Ovinos/sangue , Doenças dos Ovinos/diagnóstico
15.
J Dairy Sci ; 97(9): 5580-6, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24997670

RESUMO

The objective of this study was to evaluate the suitability of the V-Sight hematology analyzer (A. Menarini Pharma GmbH, Vienna, Austria) for bovine blood by a comparison with a reference device (Advia 2120i, Siemens AG, Erlangen, Germany). In total, 97 blood samples were obtained from 75 dairy cows. Analyzed parameters included counts of white blood cells (WBC), lymphocytes, monocytes, granulocytes, red blood cells (RBC), and platelets (PLT), as well as hemoglobin concentration (HGB), hematocrit (HCT), mean corpuscular volume, mean corpuscular hemoglobin (MCH), MCH concentration (MCHC), mean platelet volume (MPV), and plateletcrit (PCT). Based on Passing-Bablok regression, the V-Sight provided accurate and precise results for MCH and MCHC only. The PCT results were comparable to the reference method, but precision was inconclusive. Significant proportional differences were detected for monocytes, granulocytes, HCT, and PLT. For all other analytes, significant proportional and systemic differences were observed. The WBC and lymphocyte results from the V-Sight were characterized by poor accuracy, poor precision, and a high number of false positive outliers. Bland-Altman analysis indicated negative biases for all WBC parameters, the erythrocyte indices, and PLT. Positive biases were observed for RBC, HGB, HCT, MPV, and PCT. Correlation coefficients of >0.9 between the V-Sight and the reference method were found only for RBC, HGB, HCT, and MPV. Intraassay precision of the V-Sight analyzer was acceptable (coefficient of variation <5%) for granulocytes, the erythrocyte indices, and MPV. It was unacceptable (coefficient of variation ≥5%) for WBC, lymphocytes, monocytes, as well as RBC, and inconclusive for HGB, HCT, PLT, and PCT. Sensitivity was high for all RBC counts and indices as well as PLT, but low for monocytes, granulocytes, and MPV. Specificity was high for monocytes and granulocytes, but low for RBC, HCT, MCH, and MCHC. With accurate and precise results for only 2 out of 13 parameters, the V-Sight cannot be recommended for analysis of bovine blood.


Assuntos
Bovinos/sangue , Testes Hematológicos/métodos , Hematologia/instrumentação , Animais , Áustria , Plaquetas , Contagem de Eritrócitos , Feminino , Alemanha , Hematócrito , Contagem de Leucócitos , Monócitos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
J Dairy Sci ; 97(12): 7538-46, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25282414

RESUMO

The objective of this study was to evaluate the suitability of the electronic handheld devices FreeStyle Precision (FSP; Abbott Germany, Wiesbaden, Germany) and GlucoMen LX Plus (GML; A. Menarini GmbH, Vienna, Austria) for the measurement of ß-hydroxybutyrate (BHBA) in whole blood in dairy goats. Additionally, glucose concentration was analyzed with the FSP device. For method comparison, the samples were also analyzed in the laboratory by standard methods, which served as the gold standard in our study. A further objective was to evaluate the agreement between samples obtained by minimal invasive venipuncture of an ear vein and measurements of whole blood samples from the jugular vein (vena jugularis). In total, 173 blood sample pairs collected from 28 goats were obtained from an ear vein and from the jugular vein. The Spearman correlation coefficients (rsp) for BHBA concentrations determined with the FSP or GML and the gold standard were 0.95 and 0.85 for the ear vein and 0.98 and 0.88 for the jugular vein, respectively. Bland-Altman plots of differences showed a positive bias of 0.12 (ear vein) and 0.21 (jugular vein) when determination was performed with the FSP and a negative bias of 0.21 (ear vein) and 0.24 (jugular vein) when using the GML. For the FSP, applying the adjusted thresholds determined by ROC analysis of 0.9 (ear vein) and 1.0 mmol/L (jugular vein) allowed to distinguish between healthy goats and animals with hyperketonemia with sensitivities (Se) and specificities (Sp) for samples from the ear vein of 0.98 and 0.85, and from the jugular vein of 0.99 and 0.94, respectively. For the GML, adjusted thresholds were 0.5 mmol/L for the ear vein (Se=0.94, Sp=0.75) and 0.6 mmol/L for the jugular vein (Se=0.88, Sp=0.91). Repeated analyses of defined whole blood samples showed average inter- and intraassay coefficients of variation of 6.6 and 7.3% for FSP, and of 35.6 and 35.4% for GML, respectively. Test characteristics for determining glucose concentration with the FSP compared with the gold standard were poor (ear vein: rsp=0.41; jugular vein: rsp=0.51), with low validity to distinguish between hypo- and normoglycemia (Se=0.71, Sp=0.66). The present study showed good test characteristics for the FSP and moderate for the GML device for determining BHBA concentrations in whole blood. Additionally the results demonstrate the suitability of testing BHBA concentration in a blood drop obtained from an ear vein. Based on the results of this study, the FSP device is not suitable to differentiate normo- from hypoglycemia in goats.


Assuntos
Ácido 3-Hidroxibutírico/sangue , Glicemia/análise , Computadores de Mão/normas , Transtornos do Metabolismo de Glucose/veterinária , Doenças das Cabras/diagnóstico , Cetose/veterinária , Animais , Feminino , Transtornos do Metabolismo de Glucose/diagnóstico , Transtornos do Metabolismo de Glucose/fisiopatologia , Doenças das Cabras/fisiopatologia , Cabras , Cetose/diagnóstico , Cetose/fisiopatologia , Curva ROC , Sensibilidade e Especificidade
17.
J Dairy Sci ; 96(2): 1203-10, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23261381

RESUMO

The objectives of this study were to evaluate the presence of thermophilic Campylobacter in feces of calves with and without diarrhea on dairy farms and to survey farm characteristics and management practices to define risk factors for the presence of Campylobacter. Fifty dairy farms were chosen based on the presence of calf diarrhea, and 50 farms in which calves were free from diarrhea served as a standard of comparison. In total, fecal samples were taken from 382 calves. Farm data and management practices were surveyed using a questionnaire on farm. Campylobacter were isolated from fecal samples and colonies were identified by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry analysis. Campylobacter spp., mainly Campylobacter jejuni (93% of isolated species), were detected on 33% of the farms and in 14.9% of the calves. Detection of Campylobacter did not differ between farms or between calves with and without diarrhea, although we found a tendency for calves suffering from diarrhea to shed Campylobacter more often. Calves may act as a reservoir of Campylobacter and may therefore lead to infections of other animals and humans. To define control strategies to reduce Campylobacter in calves, we identified on-farm risk factors. The presence of poultry on the farm, the time of cow-calf separation following birth, the use of an individual bucket for each calf, the feeding of waste milk, and the duration of individual housing were variables significantly associated with the appearance or absence of Campylobacter.


Assuntos
Derrame de Bactérias , Infecções por Campylobacter/veterinária , Campylobacter , Doenças dos Bovinos/microbiologia , Diarreia/veterinária , Animais , Infecções por Campylobacter/epidemiologia , Infecções por Campylobacter/microbiologia , Campylobacter jejuni , Bovinos , Doenças dos Bovinos/epidemiologia , Indústria de Laticínios , Diarreia/epidemiologia , Diarreia/microbiologia , Fezes/microbiologia , Feminino , Prevalência , Fatores de Risco
18.
J Dairy Sci ; 96(12): 7719-30, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24140315

RESUMO

The objective of this study was to determine the suitability of 2 electronic hand-held devices [FreeStyle Precision (FSP), Abbott GmbH & Co. KG, Wiesbaden, Germany and GlucoMen LX Plus (GLX), A. Menarini GmbH, Vienna, Austria] for measuring ß-hydroxybutyrate (BHBA) in dairy cows. Three experiments were conducted to evaluate (1) the diagnostic performance of the devices, (2) the effect of the type of blood sample, and (3) the influence of the ambient temperature on the determined results. A total of 415 blood samples from lactating Holstein and Simmental cows were collected and analyzed with both devices (whole blood) and in a laboratory (serum). Correlation coefficients between whole-blood and serum BHBA concentrations were highly significant, with 94% for the FSP and 80% for the GLX device. Based on thresholds for subclinical ketosis of 1.2 and 1.4 mmol of BHBA/L, results obtained with the hand-held devices were evaluated by receiver operating characteristics analyses. This resulted in adjusted thresholds of 1.2 and 1.4 mmol/L for the FSP and 1.1 and 1.3 mmol/L for the GLX device. Applying these thresholds, sensitivities were 98 and 100% for the FSP and 80 and 86% for the GLX device, respectively. Corresponding specificities were 90 and 97% for the FSP and 87 and 96% for the GLX device, respectively. Additionally, concentrations of BHBA were tested with both devices in whole blood, EDTA-added whole blood, and in their resulting serum and plasma, collected from 65 animals. Determined BHBA concentrations were similar within each device for whole and EDTA-added blood, and in serum and plasma, but differed between whole blood and serum and between EDTA-added blood and plasma. Blood samples with low (0.4 mmol/L), medium (1.1 mmol/L), and high (1.6 mmol/L) BHBA concentrations were stored between +5 to +32°C and analyzed repeatedly at temperature levels differing by 4°C. Additionally, devices and test strips were stored at equal conditions and used for measurement procedures. Storage temperature of the devices and test strips did not influence the differences between the results of the laboratory and the devices, whereas the temperature of the blood samples caused significant differences. Although the level of agreement between the laboratory and the GLX device was lower than for the laboratory and the FSP device, both devices are useful tools for monitoring subclinical ketosis in dairy cows. Due to their effects on the determined results, the type and temperature of the tested sample should be considered.


Assuntos
Ácido 3-Hidroxibutírico/sangue , Doenças dos Bovinos/sangue , Testes Diagnósticos de Rotina/veterinária , Cetose/veterinária , Temperatura , Animais , Anticoagulantes , Áustria , Coleta de Amostras Sanguíneas/métodos , Coleta de Amostras Sanguíneas/veterinária , Bovinos , Testes Diagnósticos de Rotina/instrumentação , Ácido Edético , Feminino , Alemanha , Cetose/sangue , Lactação , Curva ROC , Sensibilidade e Especificidade
19.
Vet Res Commun ; 47(4): 2333-2337, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37391678

RESUMO

The objective of this study was to use a sensor-based accelerometer (ACC) to identify changes in lying, rumination, and activity times in weaned calves during the moving and regrouping process. Overall, 270 healthy Holstein calves (from approximately 16 regrouping events) at the age of approximately 4 months were enrolled and equipped with an ear-attached ACC (SMARTBOW, Smartbow GmbH/ Zoetis LLC). Sensor data were recorded for 5 d before (d -5) until 4 d after moving and regrouping (d 4). The day of regrouping was defined as d 0. Acceleration data were continuously processed by specific algorithms (developed by SMARTBOW) for lying, rumination, and activity. Lying, rumination, and activity times were averaged from d -5 to d -3 to generate a baseline value for each parameter. Parameters on d 0 to d 4 after regrouping were compared to this baseline. All parameters showed significant changes compared with the baseline at d 0. Significant decreases in rumination and inactive times were seen up to d 2. Lying time was significantly lower until d 3. The study results indicate that the ACC can be used to monitor the disruptive effects of regrouping on lying and rumination behaviors. Further research is necessary to elucidate how these changes have an impact on health, performance, and welfare and to evaluate how to reduce these potentially negative effects.


Assuntos
Acelerometria , Comportamento Animal , Bovinos , Animais , Fatores de Tempo , Acelerometria/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA