Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Ultrasound Med ; 35(1): 121-8, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26657750

RESUMO

OBJECTIVES: The purpose of this article is to evaluate the diagnostic accuracy of sonography in clinically occult femoral hernias and to describe our sonographic technique. METHODS: The clinical and imaging data for 93 outpatients referred by general surgeons, all of whom underwent sonographic evaluation and surgery, were reviewed retrospectively. Of these, 55 patients who underwent surgical exploration for groin hernias within 3 months of sonography and met all inclusion criteria were included in the study. The sonographic technique involves using the pubic tubercle as an osseous landmark to identify and appropriately visualize the femoral canal. The Valsalva maneuver is then used to differentiate the movement of normal fat (a potential pitfall) from true herniation in the femoral canal. Surgical findings were used as the reference standard by which sonographic results were judged. Two-by-two contingency tables were used to calculate the sensitivity, specificity, positive predictive value, and negative predictive value. RESULTS: In these 55 patients, surgery revealed 15 femoral hernias. Eight femoral hernias occurred in women, and 7 occurred in men. For diagnosing femoral hernias, sonography demonstrated sensitivity of 80%, specificity of 88%, a positive predictive value of 71%, and a negative predictive value of 92%. True-positive cases of femoral hernias have a sonographic appearance of a hypoechoic sac with speckled internal echoes. When examining during the Valsalva maneuver, a femoral hernia passes deep to the inguinal ligament, expands the femoral canal, displacing the normal canal fat, and effaces the femoral vein. CONCLUSIONS: Sonography can exclude femoral hernias with high confidence in light of its exceptional negative predictive value. With attention to technique and imaging criteria, the diagnostic accuracy of sonography can be enhanced.


Assuntos
Hérnia Femoral/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Armazenamento e Recuperação da Informação/métodos , Posicionamento do Paciente/métodos , Ultrassonografia/métodos , Manobra de Valsalva , Adulto , Idoso , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
J Comput Assist Tomogr ; 37(4): 631-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23863543

RESUMO

OBJECTIVE: The objective of this study was to describe the morphology of the rotator cuff tendon tears and long-term shoulder disability in conservatively treated elderly patients and determine if an association exists between these factors. METHODS: Assessment of the rotator cuff tendon tear dimensions and depth, rotator interval involvement, rotator cable morphology and location, and rotator cuff muscle status was carried out on magnetic resonance studies of 24 elderly patients treated nonoperatively for rotator cuff tendon tears. Long-term shoulder function was measured using the Western Ontario Rotator Cuff (WORC) index; Disabilities of the Shoulder, Arm, and Hand questionnaire; and the American Shoulder Elbow Self-assessment form, and a correlation between the outcome scores and morphologic magnetic resonance findings was carried out. RESULTS: The majority of large rotator cuff tendon tears are limited to the rotator cuff crescent. Medial rotator interval involvement (isolated or in association with lateral rotator interval involvement) was significantly associated with WORC physical symptoms total (P = 0.01), WORC lifestyle total (P = 0.04), percentage of all WORC domains (P = 0.03), and American Shoulder Elbow Self-assessment total (P = 0.01), with medial rotator interval involvement associated with an inferior outcome. CONCLUSIONS: Medial rotator interval tears are associated with long-term inferior outcome scores in conservatively treated elderly patients with large rotator cuff tendon tears.


Assuntos
Lacerações/patologia , Lesões do Manguito Rotador , Manguito Rotador/patologia , Lesões do Ombro , Articulação do Ombro/patologia , Traumatismos dos Tendões/patologia , Avaliação da Deficiência , Feminino , Humanos , Lacerações/reabilitação , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Autoavaliação (Psicologia) , Inquéritos e Questionários , Traumatismos dos Tendões/reabilitação , Resultado do Tratamento
3.
AJR Am J Roentgenol ; 198(1): W27-30, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22194511

RESUMO

OBJECTIVE: The objective of our study was to assess the prevalence, morphology, and position of the rotator cable and the relation of this structure to the rotator cuff crescent. MATERIALS AND METHODS: Ultrasound examinations of bilateral shoulders of asymptomatic volunteers and of the asymptomatic shoulder in patients referred for assessment of a symptomatic contralateral shoulder were performed. The images were assessed by two radiologists for the presence of the rotator cable and measurements were performed. RESULTS: The rotator cable was identified in 99% of 108 asymptomatic shoulders (49 men, 59 women) (mean age, 45 years; range, 21-79 years). The mean thickness and the mean width of the rotator cable were 1.86 mm (range, 0.6-3.5 mm) and 11.5 mm (range, 7.6-17.7 mm), respectively. The mean distance between the lateral edge of the rotator cable and the medial aspect of the greater tuberosity was 8.9 mm (range, 3.6-15.4 mm). The mean rotator cuff crescent thickness was 3.7 mm (range, 2.5-5.3 mm). A statistically significant positive correlation was found between the thickness of the rotator cable and the thickness of the rotator cuff (p<0.0001) and between the thickness of the rotator cuff and patient age (p=0.029). CONCLUSION: The rotator cable is a consistent structure seen in 99% of shoulders in this study. The morphology of this structure is variable, but rotator cable thickness correlated positively with the thickness of the rotator crescent.


Assuntos
Manguito Rotador/anatomia & histologia , Manguito Rotador/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Reprodutibilidade dos Testes , Ultrassonografia
4.
AJR Am J Roentgenol ; 197(4): W713-9, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21940544

RESUMO

OBJECTIVE: The purpose of this study was to examine the range and prevalence of asymp tomatic findings at sonography of the shoulder. MATERIALS AND METHODS: The study sample comprised 51 consecutively enrolled subjects who had no symptoms in either shoulder. Ultrasound of one shoulder per patient was performed by a musculoskeletal sonographer according to a defined protocol that included imaging of the rotator cuff, tendon of the long head of the biceps brachii muscle, subacromial-subdeltoid bursa, acromioclavicular joint, and posterior labrum. The shoulder imaged was determined at random. The 51 scans were retrospectively analyzed by three fellowship-trained musculoskeletal radiologists in consensus, and pathologic findings were recorded. Subtle or questionable findings of mild tendinosis, bursal prominence, and mild osteoarthritis were not recorded. RESULTS: Twenty-five right and 26 left shoulders were imaged. The subject age range was 40-70 years. Ultrasound showed subacromial-subdeltoid bursal thickening in 78% (40/51) of the subjects, acromioclavicular joint osteoarthritis in 65% (33/51), supraspinatus tendinosis in 39% (20/51), subscapularis tendinosis in 25% (13/51), partial-thickness tear of the bursal side of the supraspinatus tendon in 22% (11/51), and posterior glenoid labral abnormality in 14% (7/51). All other findings had a prevalence of 10% or less. CONCLUSION: Asymptomatic shoulder abnormalities were found in 96% of the subjects. The most common were subacromial-subdeltoid bursal thickening, acromioclavicular joint osteoarthritis, and supraspinatus tendinosis. Ultrasound findings should be interpreted closely with clinical findings to determine the cause of symptoms.


Assuntos
Artropatias/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Adulto , Idoso , Bursite/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/diagnóstico por imagem , Prevalência , Estudos Retrospectivos , Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador , Lesões do Ombro , Articulação do Ombro/patologia , Tendinopatia/diagnóstico por imagem , Ultrassonografia
5.
J Ultrasound Med ; 30(8): 1059-65, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21795481

RESUMO

OBJECTIVES: Implanted mesh for inguinal hernia repair is often difficult to visualize with gray scale sonography and may present without the knowledge of the sonographer. We sought to evaluate the utility of the twinkling artifact produced by inguinal mesh to assist in mesh identification. METHODS: Two reviewers evaluated focused sonographic examinations of 44 inguinal regions, 24 of which had implanted inguinal mesh. The sonographic examinations consisted of static gray scale and color Doppler images with both linear and curvilinear array transducers. The presence of the twinkling artifact and visibility of the mesh were graded on a 4-point visibility scale. RESULTS: Inguinal mesh was not easily identified on gray scale imaging using either the curvilinear array (P = .5) or linear array (P = .5) transducer. The mesh was definitely seen in 3 of 24 inguinal regions using the linear array transducer and 2 of 24 inguinal regions using the curvilinear array transducer. In 79% of inguinal regions with mesh, the twinkling artifact was produced with the curvilinear array transducer only. The artifact was not elicited when using the linear array transducer. With the use of the curvilinear array transducer and the presence of the twinkling artifact, there was a significant chance of correctly identifying the presence of mesh (P < .005) in the entire study group. CONCLUSIONS: Standard gray scale imaging alone is not reliable when identifying inguinal mesh. The twinkling artifact was present in 79% of inguinal regions with mesh when evaluated with a low-frequency curvilinear array transducer.


Assuntos
Artefatos , Hérnia Inguinal/diagnóstico por imagem , Hérnia Inguinal/cirurgia , Telas Cirúrgicas , Ultrassonografia Doppler/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Transdutores
6.
Skeletal Radiol ; 40(3): 255-69, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20033149

RESUMO

The subscapularis is the largest and most powerful of the rotator cuff muscles and fulfills an important role in glenohumeral movement and stability. The spectrum and implications of subscapularis muscle or tendon injury differ from injury to other rotator cuff components because of its unique structure and function. Diagnosing subscapularis injury is clinically difficult and assessment of subscapularis integrity may be limited during arthroscopy or open surgery. Diagnostic imaging plays an important part in diagnosing and evaluating the extent of subscapularis injury. The radiologist should be aware of the anatomy of the subscapularis, the variations in muscle or tendon injury, and the potential implications for treatment and prognosis.


Assuntos
Imageamento por Ressonância Magnética , Músculo Esquelético/lesões , Músculo Esquelético/patologia , Lesões do Manguito Rotador , Manguito Rotador/patologia , Escápula/lesões , Escápula/patologia , Humanos
7.
Clin Imaging ; 74: 131-138, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33493970

RESUMO

OBJECTIVE: Spigelian hernia is an uncommon congenital or acquired defect in the transversus abdominis aponeurosis with non-specific symptoms posing a diagnostic challenge. There is a paucity of radiology literature on imaging findings of Spigelian hernia. The objective of this study is to explore the role of MDCT in evaluating Spigelian hernia along with clinical and surgical implications. MATERIALS AND METHODS: In this IRB approved, HIPAA compliant retrospective observational analysis MDCT imaging findings of 43 Spigelian hernias were evaluated by two fellowship-trained radiologists. Imaging features evaluated were: presence of Spigelian hernia, laterality, relation to "hernia belt" (between 0 and 6 cm cranial to an imaginary axial line between both anterior superior iliac spines), the hernia neck and sac sizes, hernia content, and other coexistent hernias (umbilical, incisional, inguinal). Patient's demographics (age, gender, BMI, conditions with increased intra-abdominal pressure) were also recorded for any correlation. RESULTS: 60% (26/43) of Spigelian hernias were located below the hernia belt while 33% (14/43) within the hernia belt and 7% (3/43) above the hernia belt. The most common subtype of Spigelian hernia encountered was interparietal (84%). The mean hernia neck diameter was 3.4 cm, mean hernia sac volume was 329 cc. Hernia content included: fat (43/43) bowel (23/43), fluid (3/43). 3 patients had no clinical history provided, the remaining 37 patients' clinical presentation was asymptomatic in 73% (27/37), acute abdominal pain in 5% (2/37) and chronic abdominal pain in 22% (8/37). None of the hernia were incarcerated and none of the patients underwent emergent surgery. No significant correlation was noted between Spigelian hernia and causes of increased intra-abdominal pressure. 90% of our patients had other abdominal hernias. 30.9 was the mean BMI (20.8-69.1). CONCLUSION: Most of the Spigelian hernia occurred below the traditionally described hernia belt and the majority are of interparietal subtype that can be best diagnosed with MDCT in contrast to physical examination.


Assuntos
Hérnia Ventral , Músculos Abdominais , Dor Abdominal , Hérnia Ventral/diagnóstico por imagem , Hérnia Ventral/cirurgia , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
8.
AJR Am J Roentgenol ; 194(1): 216-25, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20028926

RESUMO

OBJECTIVE: The purpose of this article is to describe the pitfalls that may be encountered when performing musculoskeletal sonography. CONCLUSION: Sonography of the musculoskeletal system is a useful diagnostic technique, but awareness and understanding of the pitfalls will minimize errors in diagnosis.


Assuntos
Doenças Musculoesqueléticas/diagnóstico por imagem , Sistema Musculoesquelético/diagnóstico por imagem , Anisotropia , Humanos , Extremidade Inferior/diagnóstico por imagem , Valores de Referência , Ultrassonografia , Extremidade Superior/diagnóstico por imagem
9.
J Ultrasound Med ; 29(5): 691-6, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20427780

RESUMO

OBJECTIVE: In our clinical practice, we have noted a caliber change of the posterior interosseous nerve (PIN) at the elbow as seen in the long axis on sonography simulating nerve entrapment. The objective of this study was to characterize the PIN using sonography in asymptomatic individuals. METHODS: Our study retrospectively characterized the PIN in 50 elbows of 47 asymptomatic patients with sonography. Measurements of the PIN in a short-axis cross section using the circumferential trace technique and the anteroposterior (AP) dimension in the long axis were made proximal, at, and distal to the arcade of Frohse. RESULTS: There was reduction of the AP dimension of the PIN distal to the arcade of Frohse when compared with the measurements at the arcade of Frohse and proximal to the arcade (P < .0001); however, there was no significant difference between the cross-sectional area of the PIN at all 3 levels (P = .59). CONCLUSIONS: The PIN normally flattens as it enters into the supinator muscle without a notable change in the cross-sectional area. This appearance should not be misinterpreted as nerve entrapment when imaged in the long axis.


Assuntos
Cotovelo/diagnóstico por imagem , Síndromes de Compressão Nervosa/diagnóstico por imagem , Nervos Periféricos/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Diagnóstico Diferencial , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
10.
Eur Radiol ; 19(7): 1817-21, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19214517

RESUMO

We report a new lateral approach for ultrasound visualization of the distal biceps tendon. A cadaver specimen was dissected to study distal biceps anatomy relevant to this approach. Sonograms obtained in volunteers and patients are provided to illustrate this alternative method.


Assuntos
Aumento da Imagem/métodos , Tendões/diagnóstico por imagem , Ultrassonografia/métodos , Cadáver , Humanos
11.
Radiographics ; 29(7): 1971-84, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19926757

RESUMO

Bisphosphonate-related osteonecrosis of the jaw (ONJ) is characterized by nonhealing exposed bone in the maxillofacial region in patients who have undergone bisphosphonate treatment. The underlying etiology is unclear and may be multifactorial. The diagnosis is primarily clinical. Diagnostic tissue sampling may exacerbate the process and is typically avoided, necessitating other diagnostic approaches. The appearance of ONJ at diagnostic imaging is variable and includes sclerotic, lytic, or mixed lesions with possible periosteal reaction, pathologic fractures, and extension to soft tissues. There is a spectrum of signal intensity changes on T1- and T2-weighted magnetic resonance (MR) images with variable enhancement, findings that may correspond to the clinical and histopathologic stage of the process. Bone scintigraphy is sensitive with increased uptake in the area of the lesion. Although the imaging findings are nonspecific, there appears to be a role for imaging in the management of ONJ. Radiography is relatively insensitive but typically employed as the first line of radiologic investigation. Computed tomography and MR imaging are more precise in demonstrating the extent of the lesion. A number of imaging modalities have revealed lesions that may be associated with bisphosphonate exposure in asymptomatic individuals or in the context of nonspecific symptoms. The risk of these lesions advancing to overt clinical disease is unknown at this time. The radiologist should be aware of ONJ and include it in the differential diagnosis when evaluating patients with a history of bisphosphonate therapy without jaw irradiation, so as to avoid potentially harmful biopsies.


Assuntos
Difosfonatos/efeitos adversos , Doenças Maxilomandibulares/induzido quimicamente , Doenças Maxilomandibulares/diagnóstico , Imageamento por Ressonância Magnética/métodos , Osteonecrose/induzido quimicamente , Osteonecrose/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Conservadores da Densidade Óssea/efeitos adversos , Humanos
12.
J Clin Ultrasound ; 37(3): 158-60, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19170122

RESUMO

We report a sonographic technique of skin marking of the projection of nonpalpable subcutaneous foreign bodies and masses using a paperclip. Localization and marking of the overlying skin assists in preoperative planning and further management.


Assuntos
Corpos Estranhos/diagnóstico por imagem , Cuidados Pré-Operatórios/métodos , Pele/diagnóstico por imagem , Pé/diagnóstico por imagem , Corpos Estranhos/diagnóstico , Humanos , Coxa da Perna/diagnóstico por imagem , Ultrassonografia
13.
Fed Pract ; 36(7): 300-305, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31384118

RESUMO

A retrospective comparison study of the anterior-oblique and lateral approach to hip injection procedures suggests that the lateral approach may be a valuable interventional skill for those performing hip injections.

14.
AJR Am J Roentgenol ; 190(1): 5-9, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18094286

RESUMO

OBJECTIVE: This article evaluates the utility of performing a focused musculoskeletal sonography examination on the basis of patients' presenting complaints. MATERIALS AND METHODS: Six hundred two patients evaluated over 6 months were scanned using a routine protocol. At the completion of the routine examination, each patient was asked to indicate a focal point of discomfort and, if present, was rescanned over the area of discomfort. Patients were classified in one of five categories depending on whether there was a focal point of discomfort and the presence or absence of an underlying sonographic abnormality. RESULTS: Eighty-three percent of the 602 patients had a sonographically detectable abnormality, 2.2% of whom had an abnormality not detectable by routine protocol-based scanning. The more peripheral the body part, the more likely that abnormalities detected by sonography correlated with focal symptoms: 81% in the wrist and hand and 73% in the ankle and foot, compared with the more central body parts of 15% in the shoulder and 31% in the hip. Chi-square analysis showed a significant association between the body part scanned and a detectable abnormality (p < 0.0001). CONCLUSION: Although a focused examination of the distal extremities correlated with an abnormality in most cases, a protocol-based approach ensured identifying 97.4% of the symptomatic abnormalities. The addition of a focused examination to an examination by protocol further increased the identification of abnormalities.


Assuntos
Doenças Musculoesqueléticas/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Extremidades/diagnóstico por imagem , Feminino , Humanos , Articulações/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/anormalidades , Músculo Esquelético/diagnóstico por imagem , Anormalidades Musculoesqueléticas/diagnóstico por imagem , Estudos Retrospectivos , Traumatismos dos Tendões/diagnóstico por imagem , Ultrassonografia
15.
AJR Am J Roentgenol ; 190(1): 10-6, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18094287

RESUMO

OBJECTIVE: The purpose of our study was to determine which wrist fractures are not prospectively diagnosed at radiography using CT as a gold standard and to identify specific fracture patterns. MATERIALS AND METHODS: Through a search of radiology records from January 1 to December 31, 2005, 103 consecutive patients were identified as having radiographic and CT examinations of the wrist. After excluding incomplete or nondiagnostic examinations and those with a greater than 6-week interval between imaging studies, the final study group consisted of 61 wrist examinations in 60 patients. Two musculoskeletal radiologists and one emergency radiologist blindly reviewed CT examinations, and each bone (scaphoid, lunate, triquetrum, pisiform, trapezium, trapezoid, capitate, hamate, metacarpals, distal radius, distal ulna) was categorized as normal or fractured, with agreement reached by consensus. Each prospective radiographic report was categorized as either normal or fracture/equivocal for each osseous structure. Results were compared using the chi-square and Fisher's exact tests. RESULTS: In the proximal carpal row, lunate and triquetrum fractures were often radiographically occult (0% and 20%, respectively, detected at radiography); whereas in the distal carpal row, trapezoid, capitate, and hamate fractures were often occult (0%, 0%, and 40% detected at radiography, respectively). Hamate fractures were significantly associated with metacarpal fractures, and distal radius fractures were associated with scaphoid and ulna fractures. CONCLUSION: Thirty percent of wrist fractures were not prospectively diagnosed on radiography, suggesting that CT should be considered after a negative radiographic finding if clinically warranted. The location of a dorsal scaphoid avulsion fracture emphasizes the need for specific radiographic views or cross-sectional imaging for diagnosis.


Assuntos
Fraturas Ósseas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Traumatismos do Punho/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Ossos do Carpo/diagnóstico por imagem , Ossos do Carpo/lesões , Criança , Feminino , Humanos , Úmero/lesões , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Rádio (Anatomia)/lesões , Sensibilidade e Especificidade
16.
AJR Am J Roentgenol ; 190(5): W283-9, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18430813

RESUMO

OBJECTIVE: We present an overview of approaches for bone biopsy used to minimize potential tumor seeding of adjacent soft-tissue structures and compartments. We discuss a variety of approaches related to specific anatomic parts and review pertinent anatomy. CONCLUSION: We provide important guidelines and key examples that will help readers perform percutaneous needle bone biopsy safely.


Assuntos
Biópsia por Agulha/métodos , Neoplasias Ósseas/patologia , Inoculação de Neoplasia , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Biópsia por Agulha/instrumentação , Humanos
17.
AJR Am J Roentgenol ; 188(5): 1356-64, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17449782

RESUMO

OBJECTIVE: The purpose of this article is to show the typical locations of anterior abdominal wall and inguinal region hernias and to illustrate their sonographic appearances and describe pitfalls in clinical diagnosis of hernias that may be resolved with sonography. CONCLUSION: Awareness of the expected locations of anterior abdominal wall hernias and potential clinical pitfalls allows an accurate diagnosis of a hernia and helps in differentiating a hernia from other abnormalities.


Assuntos
Hérnia Abdominal/diagnóstico por imagem , Hérnia Inguinal/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Ultrassonografia
18.
AJR Am J Roentgenol ; 188(1): 198-202, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17179365

RESUMO

OBJECTIVE: We have found in our practice that the normal extensor retinaculum of the wrist may appear hypoechoic on sonography and, because it is closely applied to the extensor tendons, may simulate tenosynovitis. This study prospectively evaluates the extensor retinaculum in 50 healthy adult volunteers, characterizing its sonographic appearance. CONCLUSION: The extensor retinaculum has a characteristic appearance on sonography. A hypoechoic appearance from anisotropy should not be confused with tenosynovitis.


Assuntos
Erros de Diagnóstico/prevenção & controle , Aumento da Imagem/métodos , Músculo Esquelético/diagnóstico por imagem , Tenossinovite/diagnóstico por imagem , Articulação do Punho/diagnóstico por imagem , Adulto , Diagnóstico Diferencial , Reações Falso-Positivas , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia
19.
Med Phys ; 33(8): 2691-7, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16964846

RESUMO

Photoacoustic tomography (PAT), a nonionizing, noninvasive, laser-based technology was adapted to joint imaging for the first time. Pulsed laser light in the near-infrared region was directed toward a joint with resultant ultrasonic signals recorded and used to reconstruct images that present the optical properties in subsurface joint tissues. The feasibility of this joint imaging system was validated on a Sprague Dawley rat tail model and verified through comparison with histology. With sufficient penetration depth, PAT realized tomographic imaging of a joint as a whole organ noninvasively. Based on the optical contrast, various intra- and extra-articular tissues, including skin, fat, muscle, blood vessels, synovium and bone, were presented successfully in images with satisfactory spatial resolution that was primarily limited by the bandwidth of detected photoacoustic signals rather than optical diffusion as occurs in traditional optical imaging. PAT, with its intrinsic advantages, may provide a unique opportunity to enable the early diagnosis of inflammatory joint disorders, e.g., rheumatoid arthritis, and to monitor therapeutic outcomes with high sensitivity and accuracy.


Assuntos
Acústica , Articulações/citologia , Lasers , Tomografia Óptica/instrumentação , Tomografia Óptica/métodos , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Técnicas In Vitro , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
AJR Am J Roentgenol ; 187(1): 185-90, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16794175

RESUMO

OBJECTIVE: The purpose of this article is to describe the anatomy of the inguinal region in a way that is useful for sonographic diagnosis of inguinal region hernias, and to illustrate the sonographic appearance of this anatomy. We show sonographic techniques for evaluating inguinal, femoral, and spigelian hernias and include surgically proven examples. CONCLUSION: Understanding healthy inguinal anatomy is essential for diagnosing inguinal region hernias. Sonography can diagnose and differentiate between various inguinal region hernias.


Assuntos
Hérnia Inguinal/diagnóstico por imagem , Adulto , Feminino , Virilha/anatomia & histologia , Virilha/diagnóstico por imagem , Hérnia Abdominal/diagnóstico por imagem , Hérnia Femoral/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia , Manobra de Valsalva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA