Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Cereb Cortex ; 33(5): 2229-2244, 2023 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-35640270

RESUMO

In asymmetric hearing loss (AHL), the normal pattern of contralateral hemispheric dominance for monaural stimulation is modified, with a shift towards the hemisphere ipsilateral to the better ear. The extent of this shift has been shown to relate to sound localization deficits. In this study, we examined whether cochlear implantation to treat postlingual AHL can restore the normal functional pattern of auditory cortical activity and whether this relates to improved sound localization. The auditory cortical activity was found to be lower in the AHL cochlear implanted (AHL-CI) participants. A cortical asymmetry index was calculated and showed that a normal contralateral dominance was restored in the AHL-CI patients for the nonimplanted ear, but not for the ear with the cochlear implant. It was found that the contralateral dominance for the nonimplanted ear strongly correlated with sound localization performance (rho = 0.8, P < 0.05). We conclude that the reorganization of binaural mechanisms in AHL-CI subjects reverses the abnormal lateralization pattern induced by the deafness, and that this leads to improved spatial hearing. Our results suggest that cochlear implantation enables the reconstruction of the cortical mechanisms of spatial selectivity needed for sound localization.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Perda Auditiva , Localização de Som , Percepção da Fala , Humanos , Implante Coclear/métodos , Audição/fisiologia , Localização de Som/fisiologia , Tomografia por Emissão de Pósitrons , Percepção da Fala/fisiologia
2.
Eur Arch Otorhinolaryngol ; 278(12): 4723-4731, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33452623

RESUMO

PURPOSE: Cochlear implantation can restore access to sound and speech understanding in subjects with substantial hearing loss. The Health Utilities Index Mark III (HUI3) measures the impact of an intervention on the patient's quality of life and is sensitive to changes in hearing. In the current study we used factor analysis to predict a clinically important gain in HUI3 scores in adult cochlear implant recipients. METHODS: Data were collected in an observational study for 137 adult recipients from a single center who had at least 1-year HUI3 follow-up. Demographic and other baseline parameters were retrospectively analyzed for their association with a clinically important HUI3 scale gain, defined as at least 0.1 points. Data were also collected for the speech spatial qualities (SSQ) scale. RESULTS: Baseline telephone use and HUI3 hearing, speech and emotion attribute levels were significantly associated with clinically important gains in HUI3 scores. However, SSQ scores increased significantly with or without clinically important HUI3 gains. CONCLUSION: Those subjects who were unhappy or experienced difficulties communicating with strangers or in a group were twice as likely to obtain a clinically important gain in health utility compared to those who were happy or had less difficulty communicating. Subjects who were unable to use the telephone prior to cochlear implantation were one and a half times more likely to obtain a clinically important gain. The SSQ scale was more sensitive to hearing improvements due to cochlear implantation. An inability to use the telephone is an easy to assess biomarker for candidacy for cochlear implantation.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Percepção da Fala , Adulto , Surdez/cirurgia , Humanos , Qualidade de Vida , Estudos Retrospectivos
4.
Ear Hear ; 40(4): 905-917, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30335668

RESUMO

OBJECTIVE: Normal-hearing subjects listening to acoustic simulations of cochlear implants (CI) can obtain sentence recognition scores near 100% in quiet and in 10 dB signal-to-noise ratio (SNR) noise with acute exposure. However, average sentence recognition scores for real CI listeners are generally lower, even after months of experience, and there is a high degree of heterogeneity. Our aim was to identify the relative importance and strength of factors that prevent CI listeners from achieving early, 1-mo scores as high as those for normal-hearing-listener acoustic simulations. DESIGN: Sentence recognition scores (100 words/list, 65 dB SPL) using CI alone were collected for all adult unilateral CI listeners implanted in our center over a 5-yr period. Sentence recognition scores in quiet and in 10 dB SNR 8-talker babble, collected from 1 to 12 mo, were reduced to a single dependent variable, the "initial" score, via logarithmic regression. "Initial" scores equated to an improved estimate of 1-mo scores, and integrated the time to rise above zero score for poorer performing subjects. Demographic, device, and medical data were collected for 118 subjects who met standard CI candidacy criteria. Computed tomography of the electrode array allowing determination of the insertion depth as an angle, and the presence or absence of scala dislocation was available for 96 subjects. Predictive factors for initial scores were selected using stepwise multiple linear regression. The relative importance of predictive factors was estimated as partial r with a low bias method, and statistical significance tested with type II analysis of variance. RESULTS: The etiologies chronic otitis and autoimmune disease were associated with lower, widely variable sentence recognition scores in the long-term. More than 60% of CI listeners scored >50/100 in quiet at 1 mo. Congenital hearing loss was associated with significantly lower initial scores in quiet (r 0.23, p < 0.001), as was longer duration of hearing loss (r 0.12, p < 0.001, -0.76 pts per year). Initial scores were negatively correlated with insertion depth (r 0.09, p < 0.001, -0.1 pts per degree), with the highest initial scores being obtained for insertion depths of 300° to 400°. A much greater proportion of scala dislocations was found for perimodiolar arrays compared with straight arrays. Scores were negatively correlated with the proportion of the active electrode array found in scala vestibuli for Nucleus perimodiolar devices (r 0.14, p < 0.01, coefficient -25). Similar overall results were obtained for sentence recognition scores in noise (+10 dB SNR). The intercept value for the obtained regression functions indicated that CI listeners with the least limiting factors generally scored ~95/100 in quiet and ~90/100 in noise. In addition, CI listeners with insertion angles as low as 315° to 360° could obtain sentence recognition scores >80/100 even at 1 day after activation. Insertion depths of 360° were estimated to produce frequency-place mismatches of about one octave upward shift. CONCLUSIONS: Patient-related factors etiology and duration of deafness together explained ~40% of the variance in early sentence recognition scores, and electrode position factors ~20%. CI listeners with insertion depths of about one turn obtained the highest early sentence recognition scores in quiet and in noise, and these were comparable with those reported in the literature for normal-hearing subjects listening to 8 to 12 channel vocoder simulations. Differences between device brands were largely explained by differences in insertion depths. This indicates that physiological frequency-place mismatches of about one octave are rapidly accommodated by CI users for understanding sentences, between 1 day to 1 mo postactivation, and that channel efficiency may be significantly poorer for more deeply positioned electrode contacts.


Assuntos
Implante Coclear/métodos , Perda Auditiva/reabilitação , Percepção da Fala , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Autoimunes/complicações , Doença Crônica , Tomografia Computadorizada de Feixe Cônico , Orelha Interna/diagnóstico por imagem , Feminino , Perda Auditiva/congênito , Perda Auditiva/etiologia , Humanos , Imageamento Tridimensional , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Otite Média/complicações , Índice de Gravidade de Doença , Razão Sinal-Ruído , Fatores de Tempo , Tomografia Computadorizada Espiral , Resultado do Tratamento , Adulto Jovem
5.
Water Sci Technol ; 77(7-8): 1967-1978, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29722682

RESUMO

Clear sand adsorbs 15-35% total phosphorus (P) from septic tank effluent, but P is mobilized when low-P effluent is applied. Amorphous P compounds formed by alkali aluminate chemical addition may also be subject to leaching. Crystalline mineralization is the desired end effect that isolates P thoroughly from the water resource. Using new low-energy iron electrochemistry (EC-P process), dissolved ferrous iron reacts with sewage phosphate ions (PO4) and precipitates onto filtration medium as vivianite [Fe3(PO4)2·8H2O], as identified by scanning electron microscopy and X-ray diffraction and predicted from Eh-pH-aHPO42- phase relations. Removal rates of 90-99% in sand, soil and synthetic foam filters are obtained. The precipitation of vivianite demonstrates that P can be immobilized quickly and without intermediary adsorption phases, as with Fe-rich soils. Vitreous silicate material (VSM) or rockwool that traps and precipitates mineral P after EC-P treatment was investigated as a means of P reuse as a fertilizing soil amendment. Comparative soil leaching and growth studies using corn plants demonstrate that the VSM alone reduces P losses from soils, and that VSM which has received EC-P effluent is equivalent to or better than commercial superphosphate fertilizer.


Assuntos
Fósforo , Esgotos , Adsorção , Minerais , Solo
6.
Gastrointest Endosc ; 85(3): 559-565.e1, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27480289

RESUMO

BACKGROUND AND AIMS: Endoscopic training can be challenging for the trainee and preceptor. Frustration can result from ineffective communication regarding areas of interest. Our team developed a novel tablet application for real-time mirroring of the colonoscopy examination that allows preceptors to make annotations directly on the viewing monitor. The potential for improvement in team proficiency and satisfaction is unknown. METHODS: The on-screen endoscopic image is mirrored to an Android tablet and permits real-time annotation directly on the in-room endoscopic image display. Preceptors can also "freeze-frame" an image and provide visual on-screen instruction (telestration). Trainees, precepted by a GI attending, were 1:1 randomized to perform colonoscopy on a training phantom using the application with traditional precepting or traditional precepting alone. Magnetized polyps (size < 5 mm) were placed in 1 of 5 preset location scenarios. Each trainee performed a total of 10 colonoscopies and completed each location scenario twice. During withdrawal, the trainee and the attending identified polyps. Outcome measures included number of polyps missed and participant satisfaction after each trial. RESULTS: Fifteen trainees (6 novice and 9 GI fellows) performed a total of 150 colonoscopies where 330 polyps in total were placed. Fellows missed fewer polyps using the tablet versus traditional precepting alone (4.2% vs 12.5%; P = .04). There was no significant difference in missed polyps for novices (12.5% vs 18.8%; P = .66). Overall, fellows missed fewer polyps when compared with novices regardless of the precepting method (P = .01). The attending and all trainees reported reduced stress with improved communication using the tablet. CONCLUSIONS: Fellows missed fewer polyps using the tablet when compared with traditional endoscopy precepting. All trainees reported reduced stress, quicker identification of polyps, and improved educational satisfaction using the tablet. Our application has the potential to improve trainee plus attending team lesion detection and to enhance the endoscopy training experience for both the trainee and attending preceptor.


Assuntos
Adenoma/cirurgia , Pólipos do Colo/cirurgia , Colonoscopia/educação , Neoplasias Colorretais/cirurgia , Computadores de Mão , Gastroenterologia/educação , Tutoria/métodos , Melhoria de Qualidade , Treinamento por Simulação/métodos , Adulto , Competência Clínica , Bolsas de Estudo , Feminino , Humanos , Masculino , Modelos Anatômicos , Imagens de Fantasmas , Adulto Jovem
7.
Audiol Neurootol ; 22(3): 169-179, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29059669

RESUMO

AIMS: The Nucleus CI532 cochlear implant incorporates a new precurved electrode array, i.e., the Slim Modiolar electrode (SME), which is designed to bring electrode contacts close to the medial wall of the cochlea while avoiding trauma due to scalar dislocation or contact with the lateral wall during insertion. The primary aim of this prospective study was to determine the final position of the electrode array in clinical cases as evaluated using flat-panel volume computed tomography. METHODS: Forty-five adult candidates for unilateral cochlear implantation were recruited from 8 centers. Eleven surgeons attended a temporal bone workshop and received further training with a transparent plastic cochlear model just prior to the first surgery. Feedback on the surgical approach and use of the SME was collected via a questionnaire for each case. Computed tomography of the temporal bone was performed postoperatively using flat-panel digital volume tomography or cone beam systems. The primary measure was the final scalar position of the SME (completely in scala tympani or not). Secondly, medial-lateral position and insertion depth were evaluated. RESULTS: Forty-four subjects received a CI532. The SME was located completely in scala tympani for all subjects. Pure round window (44% of the cases), extended round window (22%), and inferior and/or anterior cochleostomy (34%) approaches were successful across surgeons and cases. The SME was generally positioned close to the modiolus. Overinsertion of the array past the first marker tended to push the basal contacts towards the lateral wall and served only to increase the insertion depth of the first electrode contact without increasing the insertion depth of the most apical electrode. Complications were limited to tip fold-overs encountered in 2 subjects; both were attributed to surgical error, with both reimplanted successfully. CONCLUSIONS: The new Nucleus CI532 cochlear implant with SME achieved the design goal of producing little or no trauma as indicated by consistent scala tympani placement. Surgeons should be carefully trained to use the new deployment method such that tip fold-overs and over insertion may be avoided.


Assuntos
Cóclea/cirurgia , Implante Coclear/métodos , Implantes Cocleares , Osso Temporal/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Cóclea/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Osso Temporal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto Jovem
8.
Ear Hear ; 35(2): e33-43, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24556970

RESUMO

OBJECTIVES: To measure benefit in terms of speech recognition in quiet and in noise, and conservation of residual hearing in three groups of subjects implanted with the Nucleus Straight Research Array cochlear implant. This device incorporates the Nucleus Slim Straight electrode carrier designed to be easier to insert into the cochlea via the round window while potentially minimizing insertion trauma. DESIGN: The study was prospective, with sequential enrolment and within-subject repeated measures; 35 subjects were 15 to 84 years of age with varying levels of bilateral high-frequency HL. Subjects were divided into three groups (A, B, and C) according to preoperative air conduction hearing thresholds in the ear to implant at 500 Hz; A ≤ 50 (n = 11), 50 < B < 80 (n = 13), and C ≥ 80 (n = 11) dB HL. Speech recognition was assessed preoperatively and at intervals up to 1 year postimplantation. Hearing thresholds were monitored over time and CT scans were used to estimate electrode positions. RESULTS: Preoperative mean word recognition score was significantly greater for group A compared with group C in quiet (diff. 26.6%pts, p < 0.05), but not so in noise (diff. 7.9%pts, p = 0.72). However, a greater proportion of subjects in group A (81%) achieved a "worthwhile" gain in speech recognition score (>20%pts) in quiet compared with group C (63%). More importantly, for speech recognition in noise, all subjects in groups A and B achieved a >20%pts gain compared with only 73% in group C. Hearing in implanted ears was well conserved for low frequencies, both initially and up to 12 months postoperatively (15 dB median increase in thresholds 250 to 500 Hz). Only 3 of 35 (9%) cases lost all residual hearing in the implanted ear by 12 months. Where characteristic frequency corresponded to a position occupied by the electrode array, threshold increase was correlated with the preoperative hearing threshold (r = 0.7; p < 0.001) and closely approximated reported estimates of residual outer hair cell gain. For characteristic frequencies at positions apical to the electrode tip, the relation between threshold increase and residual hearing decreased in amplitude at 45 to 135 degrees (r = 0.42; p < 0.05), and disappeared at >135 degrees (r = 0.05; p > 0.05). CONCLUSION: Gains in speech recognition scores for subjects with better residual low-frequency hearing were greater or equal to those obtained by subjects with poorer residual hearing. Residual hearing after cochlear implantation with the Nucleus Slim Straight electrode array was well conserved across all three groups. It appears that the gain provided by outer hair cell function may be completely suppressed when an electrode array is in close proximity to the organ of Corti.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Perda Auditiva Bilateral/cirurgia , Perda Auditiva de Alta Frequência/cirurgia , Percepção da Fala , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Audiometria de Tons Puros , Estudos de Coortes , Eletrodos Implantados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Teste do Limiar de Recepção da Fala , Resultado do Tratamento , Adulto Jovem
9.
Trends Hear ; 28: 23312165231224643, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38361477

RESUMO

Cochlear implantation successfully improves hearing in most adult recipients. However, in rare cases, post-implant rehabilitation is required to maximize benefit. The primary aim of this investigation was to test if self-reports by cochlear implant users indicate the need for post-implant rehabilitation. Listening performance was assessed with the Speech, Spatial and Qualities short-form SSQ12, which was self-administered via a web-based survey. Subjects included over 2000 adult bilateral or unilateral cochlear implant users with at least one year of experience. A novel application of regression tree analysis identified core SSQ12 items that serve as first steps in establishing a plan for further rehabilitation: items 1, 8, and 11 dealing with single-talker situations, loudness perception, and clarity, respectively. Further regression and classification tree analyses revealed that SSQ12 item scores were weakly related to age, degree of tinnitus, and use of bilateral versus unilateral implants. Conversely, SSQ12 scores were strongly associated with self-rated satisfaction and confidence in using their cochlear implant. The SSQ12 total scores did not vary significantly over 1-9 or more years' experience. These findings suggest that the SSQ12 may be a useful tool to guide rehabilitation at any time after cochlear implantation. Identification of poor performance may have implications for timely management to improve the outcomes, through various techniques such as device fitting adjustments, counseling, active sound exposure, and training spatial hearing.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Humanos , Fala , Audição
10.
Health Econ ; 22(12): 1440-51, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23280730

RESUMO

There has been recent controversy about whether aid directed specifically to health has caused recipient governments to reallocate their own funds to non-health areas. At the same time, general budget support (GBS) has been increasing. GBS allows governments to set their own priorities, but little is known about how these additional resources are subsequently used. This paper uses cross-country panel data to assess the impact of GBS programmes on health spending in low-income and middle-income countries, using dynamic panel techniques to estimate unbiased coefficients in the presence of serial correlation. We found no clear evidence that GBS had any impact, positive or negative, on government health spending derived from domestic sources. GBS also had no observed impact on total government health spending from all sources (external as well as domestic). In contrast, health-specific aid was associated with a decline in health expenditures from domestic sources, but there was not a full substitution effect. That is, despite this observed fungibility, health-specific aid still increases total government health spending from all sources. Finally, increases in total government expenditure led to substantial increases in domestic government health expenditures.


Assuntos
Orçamentos/métodos , Setor de Assistência à Saúde/economia , Orçamentos/organização & administração , Financiamento Governamental/economia , Financiamento Governamental/métodos , Gastos em Saúde , Humanos , Modelos Econômicos , Alocação de Recursos/economia , Alocação de Recursos/métodos
11.
Int J Audiol ; 52(12): 838-48, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23992489

RESUMO

OBJECTIVES: To investigate the preservation of residual hearing in subjects who received the Nucleus Hybrid L24 cochlear implant. To investigate the performance benefits up to one year post-implantation in terms of speech recognition, sound quality, and quality of life. DESIGN: Prospective, with sequential enrolment and within-subject comparisons. Post-operative performance using a Freedom Hybrid sound processor was compared with that of pre-operative hearing aids. STUDY SAMPLE: Sixty-six adult hearing-impaired subjects with bilateral severe-to-profound high frequency hearing loss. RESULTS: Group median increase in air-conduction thresholds in the implanted ear for test frequencies 125-1000 Hz was < 15 dB across the population; both immediately and one year post-operatively. Eighty-eight percent of subjects used the Hybrid processor at one year post-op. Sixty-five percent of subjects had significant gain in speech recognition in quiet, and 73% in noise (≥ 20 percentage points/2 dB SNR). Mean SSQ subscale scores were significantly improved (+ 1.2, + 1.3, + 1.8 points, p < 0.001), as was mean HUI3 score (+ 0.117, p < 0.01). Combining residual hearing with CI gave 22-26 %age points mean benefit in speech recognition scores over CI alone (p < 0.01). CONCLUSIONS: Useful residual hearing was conserved in 88% of subjects. Speech perception was significantly improved over preoperative hearing aids, as was sound quality and quality of life.


Assuntos
Implante Coclear/instrumentação , Implantes Cocleares , Correção de Deficiência Auditiva/instrumentação , Perda Auditiva Neurossensorial/reabilitação , Pessoas com Deficiência Auditiva/reabilitação , Adulto , Idoso , Idoso de 80 Anos ou mais , Audiometria de Tons Puros , Audiometria da Fala , Limiar Auditivo , Europa (Continente) , Feminino , Audição , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/fisiopatologia , Perda Auditiva Neurossensorial/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Ruído/efeitos adversos , Mascaramento Perceptivo , Pessoas com Deficiência Auditiva/psicologia , Estudos Prospectivos , Desenho de Prótese , Qualidade de Vida , Reconhecimento Psicológico , Índice de Gravidade de Doença , Inteligibilidade da Fala , Percepção da Fala , Fatores de Tempo , Adulto Jovem
12.
JAMA Netw Open ; 6(6): e2320527, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37389875

RESUMO

Importance: Preoperative high-intensity interval training (HIIT) is associated with improved cardiorespiratory fitness (CRF) and may improve surgical outcomes. Objective: To summarize data from studies comparing the association of preoperative HIIT vs standard hospital care with preoperative CRF and postoperative outcomes. Data Sources: Data sources included Medline, Embase, Cochrane Central Register of Controlled Trials Library, and Scopus databases with no language constraints, including abstracts and articles published before May 2023. Study Selection: The databases were searched for randomized clinical trials and prospective cohort studies with HIIT protocols in adult patients undergoing major surgery. Thirty-four of 589 screened studies met initial selection criteria. Data Extraction and Synthesis: A meta-analysis was performed according to Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Data were extracted by multiple independent observers and pooled in a random-effects model. Main Outcomes and Measures: The primary outcome was change in CRF, as measured by either peak oxygen consumption (V̇o2 peak) or 6-Minute Walk Test (6MWT) distance. Secondary outcomes included postoperative complications; hospital length of stay (LOS); and changes in quality of life, anaerobic threshold, and peak power output. Results: Twelve eligible studies including 832 patients were identified. Pooled results indicated several positive associations for HIIT when compared with standard care either on CRF (V̇o2 peak, 6MWT, anaerobic threshold, or peak power output) or postoperative outcomes (complications, LOS, quality of life), although there was significant heterogeneity in study results. In 8 studies including 627 patients, there was moderate-quality evidence of significant improvement in V̇o2 peak (cumulative mean difference, 2.59 mL/kg/min; 95% CI, 1.52-3.65 mL/kg/min; P < .001). In 8 studies including 770 patients, there was moderate-quality evidence of a significant reduction in complications (odds ratio, 0.44; 95% CI, 0.32-0.60; P < .001). There was no evidence that HIIT differed from standard care in hospital LOS (cumulative mean difference, -3.06 days; 95% CI, -6.41 to 0.29 days; P = .07). The analysis showed a high degree of heterogeneity in study outcomes and an overall low risk of bias. Conclusions and Relevance: The results of this meta-analysis suggest that preoperative HIIT may be beneficial for surgical populations through the improvement of exercise capacity and reduced postoperative complications. These findings support including HIIT in prehabilitation programs before major surgery. The high degree of heterogeneity in both exercise protocols and study results supports the need for further prospective, well-designed studies.


Assuntos
Aptidão Cardiorrespiratória , Treinamento Intervalado de Alta Intensidade , Humanos , Adulto , Estudos Prospectivos , Qualidade de Vida , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle
13.
Int J Pediatr Otorhinolaryngol ; 170: 111583, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37245391

RESUMO

OBJECTIVES: The aim of this study was to report on the educational placement, quality of life and speech reception changes in a prospectively recruited group of children after they received a cochlear implant (CI). METHOD: Data was collected on 1085 CI recipients of as part of a prospective, longitudinal, observational, international, multi-centre, paediatric registry, initiated by Cochlear Ltd (Sydney, NSW, Australia). Outcome data from children (≤10 years old) implanted in routine practice was voluntarily entered into a central, externally hosted, e-platform. Collection occurred prior to initial device activation (baseline) and at six monthly follow-up intervals up to 24 months and then at 3 years post activation. Clinician reported baseline and follow up questionnaires and Categories of Auditory Performance version II (CAP-II) outcomes were collated. Self-reported evaluation forms and patient information were provided by the parent/caregiver/patient via the implant recipient baseline and follow up, Children Using Hearing Implants Quality of Life (CuHIQoL) and Speech Spatial Qualities (SSQ-P) Parents Version questionnaires. RESULTS: Children were mainly bilaterally profoundly deaf, unilaterally implanted and used a contralateral hearing aid. Prior to implant 60% used signing or total communication as their main mode of communication. Mean age at implant was 3.2 ± 2.2 years (range 0-10 years). At baseline 8.6% were in mainstream education with no additional support and 82% had not yet entered school. After three years of implant use, 52% had entered mainstream education with no additional support and 38% had not yet entered school. In the sub-group of 141 children who were implanted at or after three years of age and were thus old enough to be in mainstream school at the three-year follow up, an even higher proportion (73%) were in mainstream education with no support. Quality of life scores for the child improved statistically significantly post implant compared to baseline and continued to improve significantly at each interval up to 3 years (p < 0.001). Parental expectation scores reduced statistically significantly from baseline compared to all intervals (p < 0.028) and then increased significantly at 3 years compared to all post baseline follow-up intervals (p < 0.006). The impact on family life was reduced post implant compared to baseline and continued to reduce between annual intervals (p < 0.001). At three years post follow up median CAP II scores were 7 (IQR 6-7) and mean SSQ-P scores were 6.8 (SD1.9) 6.0 (SD1.9) and 7.4 (SD 2.3) for speech spatial and qualities scales respectively. SSQ-P and CAP II scores improved statistically and clinically significantly compared to baseline by one year post implantation. CAP II scores continued to improve at each test interval up to three years post implant. Speech and Qualities scores improved significantly between years 1 and 2 (p < 0.001), but only the Speech scores improved significantly between years 2 and 3 (p = 0.004). CONCLUSIONS: Mainstream educational placement was achievable for most of the children, including those implanted at an older age. Quality of life for the child and the wider family improved. Future research could focus on the impact of mainstream school placement on children's academic progress, including measures of academic attainment and social functioning.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Percepção da Fala , Criança , Humanos , Recém-Nascido , Lactente , Pré-Escolar , Surdez/cirurgia , Surdez/reabilitação , Qualidade de Vida , Estudos Prospectivos , Percepção da Fala/fisiologia , Resultado do Tratamento
14.
Audiol Neurootol ; 17(2): 82-91, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-21846981

RESUMO

INTRODUCTION: The Nucleus Straight Research Array (SRA) cochlear implant has a new 25-mm electrode carrier designed to minimize insertion trauma, in particular allowing easy insertion via the round window. The aims of this study were to measure preoperative to postoperative benefit in terms of speech recognition in quiet and in noise in three groups of patients (electrical complement, EC; electrical stimulation, ES; electro-acoustic stimulation, EAS) with varying levels of low-frequency hearing, and to evaluate the preservation of residual hearing after implantation with the SRA cochlear implant. METHODS: The study design was prospective with sequential enrolment and within-subject comparisons: 23 adult cochlear implant candidates were divided into three groups according to their level of preoperative residual hearing at 500 Hz (EC ≤50 dB; 50 dB < EAS < 80 dB; ES ≥80 dB). Monosyllabic word recognition using the SRA cochlear implant in combination with residual low-frequency hearing was assessed at 4 and 13 months after implantation. Hearing threshold levels were also monitored over time. RESULTS: Subjects across all three groups had significant improvements in speech recognition scores (i.e. >20 percentage points) both for listening in quiet (71% of subjects) and in noise (100% of subjects). The average score at 4 months after operation for words presented in quiet was 61.7%, and in 10 dB SNR noise 46.5%, compared to 34.4 and 10.6% preoperatively (p < 0.001). All subjects retained measurable hearing at 500 Hz in the implanted ear at 4 months after the operation; mean increases were 19, 29 and 1 dB for the EC, EAS and ES groups (n = 21). Across frequencies of 125-1000 Hz, the median increase in thresholds was 15 dB up to 13 months postoperatively (n = 15). CONCLUSIONS: Speech recognition performance of subjects with various levels of residual low-frequency hearing was significantly improved with the SRA cochlear implant. A high level and rate of hearing preservation was achieved with the SRA implanted using a round window surgical technique. Subjects with preoperative low-frequency hearing levels between 50 and 80 dB HL (EAS group) tended to lose more hearing than those with either better or worse hearing.


Assuntos
Limiar Auditivo , Cóclea/cirurgia , Implante Coclear/métodos , Implantes Cocleares , Perda Auditiva/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Audiometria da Fala , Feminino , Testes Auditivos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
15.
Int J Audiol ; 51(3): 164-73, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22122354

RESUMO

OBJECTIVE: To compare results on the everyday sentence test 'FIST', the new closed-set sentence test 'FrMatrix', and the digit triplet screening test 'FrDigit3'. DESIGN: First, the FrMatrix was developed and normative values were obtained. Subsequently, speech reception thresholds (SRTs) for the three types of tests were gathered at four study centers representing different geographic regions in Belgium and France. STUDY SAMPLE: Fifty-seven normal-hearing listeners took part in the normative study of the FrMatrix, and 118 subjects, with a wide range of hearing thresholds, participated in the comparative study. RESULTS: Homogenizing the individual words of the FrMatrix with regard to their intelligibility resulted in a reference SRT of -6.0 (±0.6) dB SNR and slope at the SRT of 14.0 %/dB. The within-subject variability was only 0.4 dB. Comparison of the three tests showed high correlations between the SRTs mutually (>0.81). The FrMatrix had the highest discriminative power, both in stationary and in fluctuating noise. For all three tests, differences across the participating study centers were small and not significant. CONCLUSIONS: The FIST, the FrMatrix, and the FrDigit3 provide similar results and reliably evaluate speech recognition performance in noise both in normal-hearing and hearing-impaired listeners.


Assuntos
Ruído , Testes de Discriminação da Fala , Teste do Limiar de Recepção da Fala , Adulto , Bélgica , Feminino , França , Humanos , Idioma , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
16.
J Assoc Res Otolaryngol ; 23(5): 665-680, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35918501

RESUMO

The stimulation rate in cochlear implant (CI) sound coding, or the "carrier" rate in pulses per second (pps), is known to influence pitch perception, as well as loudness perception and sound quality. Our main objective was to investigate the effects of reduced carrier rate on the loudness and pitch of coded speech samples. We describe two experiments with 16 Nucleus® CI users, where we controlled modulation characteristics and carrier rate using Spectral and Temporal Enhanced Processing (STEP), a novel experimental multichannel sound coder. We used a fixed set of threshold and comfortable stimulation levels for each subject, obtained from clinical MAPs. In the first experiment, we determined equivalence for voice pitch ranking and voice gender categorization between the Advanced Combination Encoder (ACE), a widely used clinical strategy in Nucleus® recipients, and STEP for fundamental frequencies (F0) 120-250 Hz. In the second experiment, loudness was determined as a function of the input amplitude of speech samples for carrier rates of 1000, 500, and 250 pps per channel. Then, using equally loud sound coder programs, we evaluated the effect of carrier rate on voice pitch perception. Although nearly all subjects could categorize voice gender significantly above chance, pitch ranking varied across subjects. Overall, carrier rate did not substantially affect voice pitch ranking or voice gender categorization: as long as the carrier rate was at least twice the fundamental frequency, or when stimulation pulses for the lowest, 250 pps carrier were aligned to F0 peaks. These results indicate that carrier rates as low as 250 pps per channel are sufficient to support functional voice pitch perception for those CI users sensitive to temporal pitch cues; at least when temporal modulations and pulse timings in the coder output are well controlled by novel strategies such as STEP.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Humanos , Implante Coclear/métodos , Percepção da Altura Sonora/fisiologia , Percepção Sonora/fisiologia , Sinais (Psicologia) , Percepção da Fala/fisiologia , Estimulação Acústica/métodos
17.
Sci Rep ; 12(1): 14423, 2022 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-36002556

RESUMO

Tinnitus is a common symptom in cochlear implant (CI) recipients. There is no clear evidence of the influence of tinnitus on hearing-related quality of life (QoL) in this population. The aim of this study was to assess the relationship between hearing-related QoL measured by the Speech, Spatial and Qualities of Hearing scale (SSQ12) and tinnitus annoyance or perceived change in tinnitus annoyance after cochlear implantation. The study sample consisted of 2322 implanted adults across France, Germany, Ireland, Italy, the Netherlands, Sweden and the United Kingdom. Information relating to QoL measured using the SSQ12 and tinnitus annoyance and change in tinnitus annoyance, assessed using single-item questions, were collected one or more years post-implantation. The relationship between SSQ12 score and tinnitus annoyance or change in tinnitus annoyance was analysed using linear models adjusted for age and unilateral versus bilateral implants. Tukey pairwise tests were used to compare mean SSQ12 scores across levels of tinnitus annoyance and changes. Tinnitus prevalence was 33.9% post-implantation. Recipients with tinnitus had a significantly lower SSQ12 score than recipients without tinnitus. SSQ scores varied significantly with tinnitus annoyance, age and unilateral versus bilateral implants. Overall, CI recipients who experienced less bothersome tinnitus reported better hearing-related QoL. Healthcare professionals should be aware of the influence of tinnitus on CI recipients' hearing to manage patient expectations.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Zumbido , Adulto , Audição , Humanos , Qualidade de Vida , Inquéritos e Questionários , Zumbido/etiologia , Zumbido/cirurgia , Resultado do Tratamento
18.
J Palliat Med ; 25(9): 1404-1408, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35333610

RESUMO

Background: End-stage liver disease (ESLD) is associated with high morbidity and mortality, with liver transplantation as the only existing cure. Despite reduced quality of life and limited life expectancy, referral to palliative care (PC) rarely occurs. Moreover, there is scarcity of data on the appropriate timing and type of PC intervention needed. Aim: To evaluate PC utilization and documentation in ESLD patients declined or delisted for transplant at a tertiary care medical center with a large liver transplantation program. Methods: We performed a retrospective cohort study of all patients discussed in Liver Transplant Committee (LTC) at our academic medical center between August 2018 and May 2020 in the United States. Patients declined or delisted for liver transplantation were included. Baseline demographics, model for end-stage liver disease (MELD) score, decompensation events, and reason for transplant ineligibility were recorded. The primary outcome was PC referral. Secondary outcomes included survival from LTC decision, time from LTC decision to PC referral, and code status in relation to PC referral. Results: Of 769 patients discussed at LTC, 135 were declined for transplantation. Thirty-seven (27%) received referral to PC. When adjusting for body mass index and age, MELD score of 21-30 had odds ratio (OR) of 4.5 (95% confidence interval [CI]: 1.7-12.3) and MELD score >30 had OR of 12.8 (95% CI: 3.9-47.7) for PC referral when compared with MELD score <20. When adjusting for MELD score, presence of ascites had OR of 4.6 (95% CI: 1.1-19.1) and presence of multiple complications had OR of 2.2 (95% CI: 2.2-3.8). Conclusions: Only 37 (27%) patients delisted or declined for liver transplantation were referred to PC. MELD score and degree of decompensation were important factors associated with referral. Continued exploration of these data could help guide future studies and help determine timing and criteria for PC referral.


Assuntos
Doença Hepática Terminal , Transplante de Fígado , Doença Hepática Terminal/cirurgia , Humanos , Cuidados Paliativos , Qualidade de Vida , Encaminhamento e Consulta , Estudos Retrospectivos , Índice de Gravidade de Doença , Estados Unidos
19.
Front Aging Neurosci ; 13: 589296, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33716706

RESUMO

Older adults with mild or no hearing loss make more errors and expend more effort listening to speech. Cochlear implants (CI) restore hearing to deaf patients but with limited fidelity. We hypothesized that patient-reported hearing and health-related quality of life in CI patients may similarly vary according to age. Speech Spatial Qualities (SSQ) of hearing scale and Health Utilities Index Mark III (HUI) questionnaires were administered to 543 unilaterally implanted adults across Europe, South Africa, and South America. Data were acquired before surgery and at 1, 2, and 3 years post-surgery. Data were analyzed using linear mixed models with visit, age group (18-34, 35-44, 45-54, 55-64, and 65+), and side of implant as main factors and adjusted for other covariates. Tinnitus and dizziness prevalence did not vary with age, but older groups had more preoperative hearing. Preoperatively and postoperatively, SSQ scores were significantly higher (Δ0.75-0.82) for those aged <45 compared with those 55+. However, gains in SSQ scores were equivalent across age groups, although postoperative SSQ scores were higher in right-ear implanted subjects. All age groups benefited equally in terms of HUI gain (0.18), with no decrease in scores with age. Overall, younger adults appeared to cope better with a degraded hearing before and after CI, leading to better subjective hearing performance.

20.
BMJ Health Care Inform ; 28(1)2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33849921

RESUMO

INTRODUCTION: Health Data Research UK designated seven UK-based Hubs to facilitate health data use for research. PIONEER is the Hub in Acute Care. PIONEER delivered workshops where patients/public citizens agreed key principles to guide access to unconsented, anonymised, routinely collected health data. These were used to inform the protocol. METHODS: This paper describes the PIONEER infrastructure and data access processes. PIONEER is a research database and analytical environment that links routinely collected health data across community, ambulance and hospital healthcare providers. PIONEER aims ultimately to improve patient health and care, by making health data discoverable and accessible for research by National Health Service, academic and commercial organisations. The PIONEER protocol incorporates principles identified in the public/patient workshops. This includes all data access requests being reviewed by the Data Trust Committee, a group of public citizens who advise on whether requests should be supported prior to licensed access. ETHICS AND DISSEMINATION: East Midlands-Derby REC (20/EM/0158): Confidentiality Advisory Group (20/CAG/0084). www.PIONEERdatahub.co.uk.


Assuntos
Cuidados Críticos , Bases de Dados Factuais , Medicina Estatal , Cuidados Críticos/métodos , Bases de Dados Factuais/normas , Humanos , Projetos de Pesquisa , Medicina Estatal/organização & administração , Medicina Estatal/estatística & dados numéricos , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA