Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Indian Pacing Electrophysiol J ; 24(1): 35-39, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37804946

RESUMO

BACKGROUND: While steerable sheaths are widely used to improve catheter stability and contact force during radiofrequency (RF) catheter ablation in patients with atrial fibrillation (AF), steerable sheaths are less commonly used during transseptal puncture. This study evaluated whether left atrial catheterization efficiency can be improved using the VersaCross combined steerable sheath and transseptal system compared to previous standard workflow. METHODS: This study retrospectively analyzed AF ablation performed using the VersaCross Workflow consisting of VersaCross steerable sheath and RF wire for transseptal puncture and catheter ablation (VCW) to the standard workflow using a fixed curve sheath with RF needle followed by exchange for an Agilis steerable sheath for catheter ablation (STW). RESULTS: Thirty patients underwent RF ablation for paroxysmal or persistent AF, 15 using the VCW and 15 using the STW. Transseptal puncture time was 10.8 mins faster with the VCW compared to the standard workflow (20.9 ± 5.9 min vs. 31.7 ± 15.1 min; p = 0.024). Time to left atrial catheterization was 40% faster with the VCW compared to the STW (21.3 ± 5.8 min vs. 35.2 ± 14.4 min; p = 0.003). Overall procedure time was 14.2 min faster in the VCW compared to the STW (86.3 ± 16.1 min vs. 100.5 ± 19.3 min; p = 0.044). CONCLUSIONS: Use of the VersaCross steerable system significantly reduced time to transseptal puncture, time to left atrial catheterization, and overall RF ablation time.

3.
Heart Rhythm ; 13(8): 1575-80, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27005930

RESUMO

BACKGROUND: Tissue refractoriness to conduction is a crucial electrophysiological factor in determining susceptibility to fibrillation. The relationship between atrial refractoriness and future onset of atrial fibrillation (AF) has not been well studied. OBJECTIVES: We investigated whether atrial effective refractory period (AERP) was associated with AF occurrence in a relatively healthy population. METHODS: A total of 1308 patients with no overt structural heart diseases and no evidence of congestive heart failure who underwent electrophysiology studies for paroxysmal supraventricular tachycardia from January 1986 to January 2011 were included in the study (626 male, mean age 44 ± 16 years). RESULTS: AERP increased with increasing age. Over a mean follow-up of 12 years, 51 of 1308 subjects (3.9%) developed AF. In univariate analysis, baseline AERP ≥280 ms (hazard ratio [HR] 2.54, 95% confidence interval [CI] 1.27-5.07, P = .008) was strongly associated with new-onset AF. In multivariate Cox regression analysis, age (adjusted HR 1.40 per 10 years, 95% CI 1.15-1.70, P = .001) and AERP ≥280 ms (adjusted HR 2.08, 95% CI 1.03-4.21, P = .041) were associated with new-onset AF. Kaplan-Meier AF-free survival curves demonstrated that subjects with an AERP of ≥280 ms had significantly lower AF-free survival compared those with AERP of <280 ms. CONCLUSIONS: AERP increases with age and AERP of ≥280 ms was predictive of patients at significantly increased future risk of developing AF.


Assuntos
Fibrilação Atrial/fisiopatologia , Eletrocardiografia , Previsões , Frequência Cardíaca/fisiologia , Adulto , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Recidiva , República da Coreia/epidemiologia , Estudos Retrospectivos
4.
Sci Transl Med ; 8(344): 344ra86, 2016 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-27334261

RESUMO

Heart failure remains a major public health concern with a 5-year mortality rate higher than that of most cancers. Myocardial disease in heart failure is frequently accompanied by impairment of the specialized electrical conduction system and myocardium. We introduce an epicardial mesh made of electrically conductive and mechanically elastic material, to resemble the innate cardiac tissue and confer cardiac conduction system function, to enable electromechanical cardioplasty. Our epicardium-like substrate mechanically integrated with the heart and acted as a structural element of cardiac chambers. The epicardial device was designed with elastic properties nearly identical to the epicardial tissue itself and was able to detect electrical signals reliably on the moving rat heart without impeding diastolic function 8 weeks after induced myocardial infarction. Synchronized electrical stimulation over the ventricles by the epicardial mesh with the high conductivity of 11,210 S/cm shortened total ventricular activation time, reduced inherent wall stress, and improved several measures of systolic function including increases of 51% in fractional shortening, ~90% in radial strain, and 42% in contractility. The epicardial mesh was also capable of delivering an electrical shock to terminate a ventricular tachyarrhythmia in rodents. Electromechanical cardioplasty using an epicardial mesh is a new pathway toward reconstruction of the cardiac tissue and its specialized functions.


Assuntos
Sistema de Condução Cardíaco/cirurgia , Telas Cirúrgicas , Animais , Cardiomiopatias/fisiopatologia , Cardiomiopatias/cirurgia , Condutividade Elétrica , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Frequência Cardíaca/fisiologia , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Masculino , Contração Miocárdica/fisiologia , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/cirurgia , Ratos Sprague-Dawley
5.
Card Electrophysiol Clin ; 7(1): 157-63, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25784031

RESUMO

Recent clinical trials using panoramic mapping techniques have shown success in targeting rotors and focal impulses in atrial fibrillation (AF). Ablations directed toward these organized sources improve outcomes in AF. The left atrial appendage (LAA) has been suspected as a possible extrapulmonary source of AF, and ablation within the LAA or electrical isolation of the LAA improves outcomes in certain cases. This case highlights a unique example of panoramic imaging created with a computational mapping algorithm integrated in 3-dimensional mapping, which identified rotors within the LAA. Furthermore, ablations performed near an identified rotor core within the LAA terminated AF.


Assuntos
Fibrilação Atrial , Eletrocardiografia/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Imageamento Tridimensional/métodos , Idoso , Fibrilação Atrial/patologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Humanos , Masculino
6.
J Am Coll Cardiol ; 63(1): 40-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24076284

RESUMO

OBJECTIVES: The goal of this study was to develop a low-energy, implantable device-based multistage electrotherapy (MSE) to terminate atrial fibrillation (AF). BACKGROUND: Previous attempts to perform cardioversion of AF by using an implantable device were limited by the pain caused by use of a high-energy single biphasic shock (BPS). METHODS: Transvenous leads were implanted into the right atrium (RA), coronary sinus, and left pulmonary artery of 14 dogs. Self-sustaining AF was induced by 6 ± 2 weeks of high-rate RA pacing. Atrial defibrillation thresholds of standard versus experimental electrotherapies were measured in vivo and studied by using optical imaging in vitro. RESULTS: The mean AF cycle length (CL) in vivo was 112 ± 21 ms (534 beats/min). The impedances of the RA-left pulmonary artery and RA-coronary sinus shock vectors were similar (121 ± 11 Ω vs. 126 ± 9 Ω; p = 0.27). BPS required 1.48 ± 0.91 J (165 ± 34 V) to terminate AF. In contrast, MSE terminated AF with significantly less energy (0.16 ± 0.16 J; p < 0.001) and significantly lower peak voltage (31.1 ± 19.3 V; p < 0.001). In vitro optical imaging studies found that AF was maintained by localized foci originating from pulmonary vein-left atrium interfaces. MSE Stage 1 shocks temporarily disrupted localized foci; MSE Stage 2 entrainment shocks continued to silence the localized foci driving AF; and MSE Stage 3 pacing stimuli enabled consistent RA-left atrium activation until sinus rhythm was restored. CONCLUSIONS: Low-energy MSE significantly reduced the atrial defibrillation thresholds compared with BPS in a canine model of AF. MSE may enable painless, device-based AF therapy.


Assuntos
Fibrilação Atrial/terapia , Cardioversão Elétrica/métodos , Terapia por Estimulação Elétrica/instrumentação , Eletrodos Implantados , Átrios do Coração/fisiopatologia , Animais , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco , Modelos Animais de Doenças , Cães , Eletrocardiografia
7.
Heart Rhythm ; 11(8): 1433-40, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24813377

RESUMO

BACKGROUND: The relationship between a fragmented QRS complex (fQRS) on 12-lead ECG and fatal arrhythmic events in hypertrophic cardiomyopathy (HCM) remains unclear. OBJECTIVE: The purpose of this study was to investigate whether fQRS is associated with ventricular arrhythmic events (VAEs) in HCM patients. METHODS: Of an initial cohort of 273 patients (57% male, mean age 55 years) diagnosed with HCM, 167 patients were included and divided into 2 groups: those with fQRS (n = 67) and those without fQRS (n = 100). fQRS was defined as notching of the R or S wave in 2 contiguous leads. VAEs were defined as nonsustained or sustained ventricular tachycardia (VT) or sudden cardiac death (SCD). Major arrhythmic events (MAEs) were sustained VT or SCD. RESULTS: During mean follow-up of 6.3 years, univariate analysis showed that fQRS was significantly associated with increased VAEs (unadjusted hazard ratio [HR] 6.17, 95% confidence interval [CI] 2.46-15.49, P < .001) and MAEs (unadjusted HR 5.12, 95% CI 1.38-19.01, P = .014). Multivariate analysis revealed that fQRS was a strong independent predictor of VAEs (adjusted HR 6.28, 95% CI 2.49-15.84, P < .001) and MAEs (adjusted HR 6.04, 95% CI 1.49-24.39, P = .011). fQRS in the inferior leads was most closely related to MAEs compared to fQRS in other myocardial territories, and its inclusion in a risk calculator for mortality in HCM patients increased the positive predictive value from 8% to 25% in low-risk patients. CONCLUSION: Presence of an fQRS may be a good candidate marker for prediction of VAE in patients with HCM.


Assuntos
Cardiomiopatia Hipertrófica/fisiopatologia , Morte Súbita Cardíaca/etiologia , Eletrocardiografia , Cardiomiopatia Hipertrófica/complicações , Morte Súbita Cardíaca/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , República da Coreia/epidemiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Taxa de Sobrevida/tendências
8.
Heart Rhythm ; 11(7): 1184-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24726972

RESUMO

BACKGROUND: Prolongation of the corrected QT (QTc) interval on 12-lead electrocardiogram is related to total mortality and sudden cardiac death. The value of the paced QTc interval in predicting mortality has not been investigated. OBJECTIVE: To evaluate the relationship between the paced QTc interval and mortality. METHODS: Of 1440 patients who underwent pacemaker implantation from January 1990 to March 2010, 766 had a recorded intrinsic and ventricular paced rhythm and were included in this study. The intrinsic and paced QTc intervals were measured on 12-lead electrocardiogram before and 1-month after implantation. RESULTS: During a mean follow-up period of 7 ± 5 years, 189 (24.4%) patients died, of which 63 (8.1%) were cardiac deaths. Compared with patients in the first tertile of the paced QTc interval (<484 ms), patients in the third tertile (>511 ms) were significantly more likely to die (19% vs 29%; P < .05). A comparison of the third and first tertiles of the QTc interval showed that a prolonged paced QTc interval was a significant independent predictor of all-cause mortality (adjusted hazard ratio 2.08; 95% confidence interval 1.44-3.01; P < .001) and cardiac mortality (adjusted hazard ratio 2.53; 95% confidence interval 1.29-4.95; P = .007) and a better predictor than was a prolonged intrinsic QTc interval. When treated as a continuous variable, a prolonged paced QTc interval predicted increased total mortality and cardiac mortality. CONCLUSION: The paced QTc interval appears to be a more useful marker in predicting bad prognosis than does the intrinsic QTc interval in patients with indications for a permanent pacemaker.


Assuntos
Morte Súbita Cardíaca/epidemiologia , Eletrocardiografia/métodos , Síndrome do QT Longo/mortalidade , Marca-Passo Artificial/efeitos adversos , Adulto , Idoso , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , República da Coreia , Fatores de Risco , Análise de Sobrevida
9.
J Am Coll Cardiol ; 60(23): 2393-8, 2012 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-23141483

RESUMO

OBJECTIVES: The authors sought to develop a low-energy electrotherapy that terminates ventricular tachycardia (VT) when antitachycardia pacing (ATP) fails. BACKGROUND: High-energy implantable cardioverter-defibrillator (ICD) shocks are associated with device failure, significant morbidity, and increased mortality. A low-energy alternative to ICD shocks is desirable. METHODS: Myocardial infarction was created in 25 dogs. Sustained, monomorphic VT was induced by programmed stimulation. Defibrillation electrodes were placed in the right ventricular apex, and coronary sinus and left ventricular epicardium. If ATP failed to terminate sustained VT, the defibrillation thresholds (DFTs) of standard versus experimental electrotherapies were measured. RESULTS: Sustained VT ranged from 276 to 438 beats/min (mean 339 beats/min). The right ventricular-coronary sinus shock vector had lower impedance than the right ventricular-left ventricular patch (54.4 ± 18.1 Ω versus 109.8 ± 16.9 Ω; p < 0.001). A single shock required between 0.3 ± 0.2 J to 5.9 ± 2.5 J (mean 2.64 ± 3.22 J; p = 0.008) to terminate VT, and varied depending upon the phase of the VT cycle in which it was delivered. By contrast, multiple shocks delivered within 1 VT cycle length were not phase dependent and achieved lower DFT compared with a single shock (0.13 ± 0.09 J for 3 shocks, 0.08 ± 0.04 J for 5 shocks, and 0.09 ± 0.07 J for 7 shocks; p < 0.001). Finally, a multistage electrotherapy (MSE) achieved significantly lower DFT compared with a single biphasic shock (0.03 ± 0.05 J versus 2.37 ± 1.20 J; respectively, p < 0.001). At a peak shock amplitude of 20 V, MSE achieved 91.3% of terminations versus 10.5% for a biphasic shock (p < 0.001). CONCLUSIONS: MSE achieved a major reduction in DFT compared with a single biphasic shock for ATP-refractory monomorphic VT, and represents a novel electrotherapy to reduce high-energy ICD shocks.


Assuntos
Desfibriladores Implantáveis , Terapia por Estimulação Elétrica/métodos , Taquicardia Ventricular/terapia , Animais , Modelos Animais de Doenças , Cães , Eletrocardiografia , Falha de Equipamento , Taquicardia Ventricular/fisiopatologia
10.
Circ Arrhythm Electrophysiol ; 4(6): 917-25, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21980076

RESUMO

BACKGROUND: Implantable device therapy of atrial fibrillation (AF) is limited by pain from high-energy shocks. We developed a low-energy multistage defibrillation therapy and tested it in a canine model of AF. METHODS AND RESULTS: AF was induced by burst pacing during vagus nerve stimulation. Our novel defibrillation therapy consisted of 3 stages: stage (ST) 1 (1-4 low-energy biphasic [BP] shocks), ST2 (6-10 ultralow-energy monophasic [MP] shocks), and ST3 (antitachycardia pacing). First, ST1 testing compared single or multiple MP and BP shocks. Second, several multistage therapies were tested: ST1 versus ST1+ST3 versus ST1+ST2+ST3. Third, 3 shock vectors were compared: superior vena cava to distal coronary sinus, proximal coronary sinus to left atrial appendage, and right atrial appendage to left atrial appendage. The atrial defibrillation threshold (DFT) of 1 BP shock was <1 MP shock (0.55 ± 0.1 versus 1.38 ± 0.31 J, P=0.003). Two to 3 BP shocks terminated AF with lower peak voltage than 1 BP or 1 MP shock and with lower atrial DFT than 4 BP shocks. Compared with ST1 therapy alone, ST1+ST3 lowered the atrial DFT moderately (0.51 ± 0.46 versus 0.95 ± 0.32 J, P=0.036), whereas 3-stage therapy (ST1+ST2+ST3) dramatically lowered the atrial DFT (0.19 ± 0.12 versus 0.95 ± 0.32 J for ST1 alone, P=0.0012). Finally, the 3-stage therapy was equally effective for all studied vectors. CONCLUSIONS: Three-stage electrotherapy significantly reduces the AF DFT and opens the door to low-energy atrial defibrillation at or below the pain threshold.


Assuntos
Fibrilação Atrial/terapia , Função Atrial , Cardioversão Elétrica/métodos , Sistema de Condução Cardíaco/fisiopatologia , Animais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Modelos Animais de Doenças , Cães , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Átrios do Coração/fisiopatologia , Dor/etiologia , Dor/prevenção & controle , Fatores de Tempo , Estimulação do Nervo Vago
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA