Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Breast J ; 26(7): 1308-1315, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31876106

RESUMO

PURPOSE: To compare radiation dose to organs at risk in patients with early-stage breast cancer treated with lumpectomy and intraoperative radiation therapy with CT-guided HDR brachytherapy (precision breast IORT; PB-IORT) and those treated with external beam whole breast irradiation (WB-DIBH) or partial breast irradiation (PB-DIBH) with deep inspiratory breath hold. METHODS: We retrospectively identified 52 consecutive patients with left-sided breast cancers treated with either PB-IORT (n = 17, 76% outer breast) on a phase I clinical trial, adjuvant PB-DIBH (n = 18, 56% outer breast, 6% cavity boost), or WB-DIBH (n = 17, 76% outer breast, 53% with lumpectomy cavity boost). Conventional (2 Gy/fraction) or moderate hypofractionation (2.66 Gy/fraction) was prescribed for the external beam cohorts and 12.5 Gy in 1 fraction to 1 cm from the balloon surface was prescribed to the HDR brachytherapy cohort. CT-based planning was used for all patients. Organ at risk doses and excess risk ratios (ERR) for secondary lung cancers, contralateral breast cancers, and cardiac toxicity were compared between treatment techniques. RESULTS: Compared to WB-DIBH and PB-DIBH, PB-IORT resulted in lower ipsilateral lung V5, V10, V20, mean, and max dose (P < .05). Mean ipsilateral lung BED3Gy was as follows: 1.32 Gy for PB-IORT, 4.33 Gy for WB-DIBH, 3.35 Gy for PB-DIBH. The ERR for lung cancer was lowest for PB-IORT (P < .001). There was significantly higher contralateral breast max dose but lower mean BED3Gy for WB-DIBH compared with PB-IORT (P = .012, P = .011, respectively). Mean contralateral breast BED3Gy was as follows: 0.10 Gy for PB-IORT, 0.06 Gy for WB-DIBH, and 0.08 Gy for PB-DIBH. The ERR for contralateral breast cancer was low for all breast techniques, but WB-DIBH showed lower ERR compared to PB-IORT (P = .019). Mean heart BED2Gy was higher with PB-IORT at 1.26 Gy compared to 0.48 Gy and 0.24 Gy for WB-DIBH and PB-DIBH, respectively (P < .001). CONCLUSIONS: Patients with early-stage breast cancer treated with PB-IORT and with tissue-sparing external beam techniques all received low organ at risk doses, but PB-IORT resulted in far lower ipsilateral lung dose compared with external beam techniques. Our data indicate the lowest mean contralateral breast BED in the WB-DIBH group, likely due to the simplicity of the field design in low-risk patients using tangential whole breast radiation. External beam using DIBH results in lowest heart dose, but all techniques were well within recommended heart constraints.


Assuntos
Neoplasias da Mama , Neoplasias Unilaterais da Mama , Neoplasias da Mama/radioterapia , Feminino , Coração , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
2.
Brachytherapy ; 23(3): 248-256, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38519352

RESUMO

INTRODUCTION: The purpose of this prospective randomized trial was to compare the use of a novel vaginal hydrogel packing system (BrachyGel) to standard vaginal packing (VP) during high dose rate (HDR) brachytherapy (BT) for locally advanced cervical cancer (LACC). METHODS: This cross-over study included LACC patients receiving HDR BT boost (intracavitary +/- interstitial). All patients received alternating gauze or BrachyGel VP on Arms A and B. Patients, physicians, and physicists evaluated BT characteristics via a 4-point Likert scale. Adverse events (AEs) were prospectively collected and scored per CTCAE. RESULTS: The 20 patients enrolled. The mean bladder D2cc difference between gauze and BrachyGel in Arm A was 0.117 Gray (Gy) and in Arm B 0.013 Gy. The mean difference in rectum D2cc in Arm A and Arm B was -0.189 Gy and -0.191 Gy, respectively. The mean dose to 90% of the high-risk clinical target volume (HR-CTV) for gauze compared to BrachyGel was -0.032 Gy (95% CI: 0.472, 0.409). Patient-reported discomfort was similar with BrachyGel and gauze ("mild/moderate" 70.0% vs 74.0%, respectively). The clarity of VP was similar between BrachyGel and gauze (86.8% vs 89.7%, respectively). The completeness of VP was more frequently "excellent/good" with BrachyGel (79.0%) compared to gauze (56.4%). The ease of packing was more frequently "extremely easy" with BrachyGel (21.2% vs 0%). No serious AEs were reported. CONCLUSION: This randomized trial found no clinically significant difference in OAR or HR-CTV dosimetry between BrachyGel and standard VP. BrachyGel performed well compared to gauze for the patient and physician use experience.


Assuntos
Braquiterapia , Dosagem Radioterapêutica , Neoplasias do Colo do Útero , Humanos , Feminino , Neoplasias do Colo do Útero/radioterapia , Braquiterapia/métodos , Pessoa de Meia-Idade , Idoso , Adulto , Estudos Cross-Over , Radioterapia Guiada por Imagem/métodos , Estudos Prospectivos , Hidrogéis/uso terapêutico , Resultado do Tratamento
3.
J Am Coll Surg ; 238(1): 10-20, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37870228

RESUMO

BACKGROUND: Precision breast intraoperative radiation therapy (PB-IORT) is a novel method of IORT that uses customized CT-based treatment plans and high-dose-rate (HDR) brachytherapy. We conducted a phase-II multi-institution trial to evaluate the efficacy of PB-IORT. STUDY DESIGN: Between 2015 and 2022, 3 centers enrolled women aged 45 years and older with invasive or in situ carcinoma measuring 3 cm or smaller and N0 status (n = 358). Breast-conserving surgery was performed, and a multilumen balloon catheter was placed in the lumpectomy bed. CT images were used to create customized HDR brachytherapy plans that delivered 12.5 Gy to the tumor bed. The primary outcome assessed was the 5-year rate of index quadrant tumor recurrence. An interim analysis was conducted after one-third of eligible participants completed 5 years of follow-up. This trial is registered with clinicaltrials.gov (NCT02400658). RESULTS: The cohort comprised 153 participants with a median age of 64 years and median follow-up time of 5.9 years. The estimated 5-year index quadrant tumor recurrence rate and overall survival were 5.08% (95% CI 2.23 to 9.68) and 95.1%, respectively. Locoregional (ipsilateral breast and axilla) and distant recurrence rates were each 1.96%. Seven deaths occurred during the first 5 years of follow-up, with only 1 attributable to breast cancer. Overall, 68.6% of patients experienced any adverse effects, and 4 cases of breast-related severe toxicities were observed. CONCLUSIONS: This study presents the results of a planned interim analysis of a phase-II trial investigating PB-IORT and demonstrates the efficacy and safety of single-fraction, CT-based, HDR brachytherapy after breast-conserving surgery. These findings provide valuable insights into the use of PB-IORT as a treatment modality.


Assuntos
Braquiterapia , Neoplasias da Mama , Feminino , Humanos , Pessoa de Meia-Idade , Braquiterapia/efeitos adversos , Braquiterapia/métodos , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Neoplasias da Mama/patologia , Mastectomia Segmentar , Recidiva Local de Neoplasia/cirurgia , Estudos Prospectivos , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X/métodos
4.
Pract Radiat Oncol ; 10(6): e444-e451, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32289551

RESUMO

PURPOSE: Radiation therapy is a well-established treatment for symptomatic bone metastases. Despite continued advances in both planning techniques and treatment delivery, the standard workflow has remained relatively unchanged, often requiring 1 to 3 weeks and resulting in patient inconvenience and delayed palliation. We developed an expedited method wherein computed tomography simulation, treatment planning, quality assurance, and treatment delivery are performed in 1 day. This prospective pilot clinical trial evaluates the safety, efficacy, and patient satisfaction of this rapid workflow. METHODS AND MATERIALS: Patients with 1 to 3 painful bone metastases were prospectively enrolled and treated with 1 fraction of stereotactic body radiation therapy, using a same-day Scan-Plan-QA-Treat workflow, termed STAT RAD, in a phase 1/2 dose escalation trial from 8 Gy to 15 Gy per fraction. Bone pain, opioid use, patient satisfaction, performance status, and quality of life were evaluated before and at 1, 4, 8, 12, 26, and 52 weeks after treatment. Outcomes and treatment-related toxicity were analyzed. RESULTS: A total of 49 patients were enrolled, and 46 patients with 60 bone metastases were treated per the protocol. Partial or greater pain response occurred in 50% of patients at 1 week, 75% of patients at 8 weeks, 68.7% of patients at 6 months, and 33.3% of patients at 12 months. There were 2 grade-3 toxicities, including 1 spinal fracture associated with disease progression and hyperbilirubinemia. Reirradiation was required in 16.7% of treated lesions at a median time to retreatment of 4.9 months. Most patient responses (78.6%) indicated that patients would choose this workflow again. CONCLUSIONS: The results demonstrate that treating bone metastases with palliative stereotactic body radiation therapy via a single-fraction, patient-centric workflow is feasible and safe with doses up to 15 Gy. However, pain response decreased at 12 months and was associated with a 16.7% retreatment rate, which suggests that further dose escalation is warranted.


Assuntos
Neoplasias Ósseas , Radiocirurgia , Neoplasias Ósseas/radioterapia , Humanos , Dor , Estudos Prospectivos , Qualidade de Vida , Radiocirurgia/efeitos adversos
5.
Brachytherapy ; 19(5): 679-684, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32571746

RESUMO

PURPOSE: Intraoperative radiation therapy (IORT), a form of accelerated partial breast irradiation (APBI), is an appealing alternative to postoperative whole breast irradiation for early-stage breast cancer. The purpose of this study was to examine the toxicity and cosmetic outcomes of patients treated with a novel form of breast IORT (precision breast IORT; PB-IORT), that delivers a targeted, higher dose of radiation than conventional IORT. METHODS AND MATERIALS: The first 204 patients treated with PB-IORT in a Phase II clinical trial (NCT02400658) with 12 months of followup were included. Trial inclusion criteria were age ≥45 years, invasive or in situ breast cancer, tumor size ≤3 cm, and node negative. Toxicity and cosmetic scoring were performed at 6 and 12 months. RESULTS: 98 patients (48%; 95% CI, 41-55%) experienced toxicity. Seven Grade 3 toxicities occurred (3.4%; 95% CI, 1.4-6.9%). Most patients (95%) had excellent or good cosmetic outcomes (95% CI, 91-98%) at 12 months. Most patients (94%) had little or no pigmentation change (95% CI, 90-97%), 88% little to no size change (95% CI, 82-92%), and 87% experienced minimal shape change (95% CI, 82-92%). CONCLUSIONS: Overall, Grade 3+ toxicity was rare and cosmetic outcomes were excellent. Severe toxicity with PB-IORT is similar to that reported in the TARGIT trial (3.3% rate of major toxicity) but lower than APBI (NSABP-39, 10.1% Grade 3/4 toxicities). We propose that the toxicity of PB-IORT compared with TARGIT and NSABP-39 is related to the radiation dose and delivery schedule. PB-IORT offers low-toxicity and good cosmetic outcomes when compared with other forms of APBI.


Assuntos
Braquiterapia/métodos , Neoplasias da Mama/radioterapia , Carcinoma Ductal de Mama/radioterapia , Carcinoma Intraductal não Infiltrante/radioterapia , Mastectomia Segmentar/métodos , Aparência Física , Lesões por Radiação/epidemiologia , Radioterapia Adjuvante/métodos , Idoso , Mama/patologia , Carcinoma Lobular/radioterapia , Terapia Combinada , Feminino , Humanos , Cuidados Intraoperatórios/métodos , Pessoa de Meia-Idade , Dosagem Radioterapêutica
6.
Brachytherapy ; 18(3): 285-291, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30846329

RESUMO

PURPOSE: A multidisciplinary team at our institution developed a novel method of intraoperative breast radiation therapy (precision breast intraoperative radiation therapy [PB-IORT]) that uses high-dose-rate brachytherapy with CT on-rails imaging to deliver high-dose, customized radiotherapy to patients with early-stage breast cancer. This report summarizes our program's experience developing and implementing PB-IORT. METHODS AND MATERIALS: Literature on PB-IORT was reviewed including published articles and abstracts. To evaluate case volume, all patients with a breast cancer diagnosis who underwent breast surgery or breast radiation (2010-2017) at our academic institution were identified. Patients were stratified into pre-IORT and post-IORT eras with initiation of our PB-IORT program in October 2013. Overall trends in surgical and radiation therapy volume in each era were analyzed by linear regression. Travel distance for all surgical patients was calculated using Google Maps (Alphabet Inc.) and then compared between IORT and non-IORT patients. RESULTS: Data from a PB-IORT Phase 1 trial found that the primary endpoints were met and that PB-IORT is feasible and safe. The direct health system's delivery costs for PB-IORT exceed those of 16-fraction whole-breast irradiation when accounting for consumable supplies (multilumen balloon applicator = $2,750 per patient). There was a significant increase in yearly growth of breast cancer surgical volume with PB-IORT. CONCLUSIONS: Accrual rates for the ongoing Phase II trial have been quicker than expected in an area where more research is needed. The rapid accrual indicates patient interest and demand for this treatment and that it is very feasible to get more data from randomized trials.


Assuntos
Braquiterapia/métodos , Neoplasias da Mama/terapia , Desenvolvimento de Programas , Neoplasias da Mama/diagnóstico por imagem , Ensaios Clínicos Fase I como Assunto , Ensaios Clínicos Fase II como Assunto , Feminino , Acessibilidade aos Serviços de Saúde , Humanos , Período Intraoperatório , Mastectomia , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X
8.
Cardiovasc Res ; 57(1): 28-36, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12504811

RESUMO

OBJECTIVES: Women have longer rate-corrected QT intervals (QTc) and are at higher risk for developing life-threatening torsades de pointes ventricular arrhythmias than men, especially after taking medications that block cardiac human ether-a-go-go-related gene (HERG)-encoded K(+) channels. The purpose of the present study was to determine if the male sex steroid hormone, dihydrotestosterone (DHT), influences QT intervals in orchiectomized (Orch) male rabbits. METHODS: ECG and whole-cell patch-clamp analyses were employed to evaluate cardiac repolarization and K(+) currents in hearts isolated from orchiectomized (Orch) male New Zealand White rabbits receiving subcutaneous sustained release pellets for either dihydrotestosterone (DHT) or placebo. The efficacy of the treatment paradigm was monitored by measuring plasma DHT concentrations before and after the treatment period (10-14 days). RESULTS: The results show that rate- and drug-induced QT-lengthening is attenuated in hearts from DHT-treated rabbits relative to placebo-treated controls. No significant changes in QRS were observed in response to DHT, thereby indicating that DHT influences QT primarily through an effect on ventricular repolarization. In addition, hearts from DHT-treated rabbits displayed significantly less QT lengthening in response to quinidine challenge compared to placebo controls. Current densities for two important cardiac repolarizing K(+) currents, I(K1) and I(Kr), were found to be significantly increased in ventricular myocardium of DHT-treated rabbits. Further, the half-maximal voltage of activation (V(1/2)) for I(Kr) was significantly shifted to more negative potentials in myocytes from DHT vs. placebo hearts (21.2+/-1.2 vs. 30.2+/-1.4 mV, respectively, n=12, P<0.001). Corresponding changes in rabbit ether-a-go-go-related gene (RERG) mRNA were not found when examined by Northern blot hybridization. CONCLUSIONS: These results suggest that the presence of male sex steroid hormones in male rabbits helps to suppress rate- and drug-induced delays in cardiac repolarization. DHT action produces increased current densities for I(K1) and I(Kr) and a left-shift in the V(1/2) for I(Kr) that could account, at least in part, for the observed QTc differences between males and females. Since little change was seen in ventricular RERG gene expression, DHT action in the heart may influence I(Kr) via post-transcriptional and/or post-translational mechanisms.


Assuntos
Di-Hidrotestosterona/farmacologia , Frequência Cardíaca/efeitos dos fármacos , Canais de Potássio Corretores do Fluxo de Internalização/metabolismo , Animais , Estimulação Cardíaca Artificial , Eletrocardiografia/efeitos dos fármacos , Masculino , Modelos Animais , Orquiectomia , Técnicas de Patch-Clamp , Perfusão , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA