Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Circ Cardiovasc Interv ; 12(10): e007939, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31607155

RESUMO

BACKGROUND: Invasive fractional flow reserve (FFRINV) is the standard technique for assessing myocardial ischemia. Pressure distortions and measurement location may influence FFRINV interpretation. We report a technique for performing invasive fractional flow reserve (FFRINV) by minimizing pressure distortions and identifying the proper location to measure FFRINV. METHODS: FFRINV recordings were obtained prospectively during manual hyperemic pullback in 100 normal and diseased coronary arteries with single stenosis, using 4 measurements from the terminal vessel, distal-to-the-lesion, proximal vessel, and guiding catheter. FFRINV profiles were developed by plotting FFRINV values (y-axis) and site of measurement (x-axis), stratified by stenosis severity. FFRINV≤0.8 was considered positive for lesion-specific ischemia. RESULTS: Erroneous FFRINV values were observed in 10% of vessels because of aortic pressure distortion and in 21% because of distal pressure drift; these were corrected by disengagement of the guiding catheter and re-equalization of distal pressure/aortic pressure, respectively. There were significant declines in FFRINV from the proximal to the terminal vessel in normal and stenotic coronary arteries (P<0.001). The rate of positive FFRINV was 41% when measured from the terminal vessel and 20% when measured distal-to-the-lesion (P<0.001); 41.5% of positive terminal measurements were reclassified to negative when measured distal-to-the-lesion. Measuring FFRINV 20 to 30 mm distal-to-the-lesion (rather than from the terminal vessel) can reduce errors in measurement and optimize the assessment of lesion-specific ischemia. CONCLUSIONS: Meticulous technique (disengagement of the guiding catheter, FFRINV pullback) is required to avoid erroneous FFRINV, which occur in 31% of vessels. Even with optimal technique, FFRINV values are influenced by stenosis severity and the site of pressure measurement. FFRINV values from the terminal vessel may overestimate lesion-specific ischemia, leading to unnecessary revascularization.


Assuntos
Cateterismo Cardíaco/métodos , Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Idoso , Estudos de Casos e Controles , Tomada de Decisão Clínica , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Estenose Coronária/fisiopatologia , Estenose Coronária/terapia , Feminino , Humanos , Hiperemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Vasodilatadores/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA