RESUMO
BACKGROUND: Reference change values (RCV) are used to indicate a change in analyte concentration that is unlikely to be due to random variation in the patient or the measurement. Current theory describes RCV relative to a first measurement result (X1). We investigate an alternative view predicting the starting point for RCV calculations from X1 and its location in the reference interval. METHODS: Data for serum sodium, calcium, and total protein from the European Biological Variation study and from routine clinical collections were analyzed for the effect of the position of X1 within the reference interval on the following result from the same patient. A model to describe the effect was determined, and an equation to predict the RCV for a sample in a population was developed. RESULTS: For all data sets, the midpoints of the RCVs were dependent on the position of X1 in the population. Values for X1 below the population mean were more likely to be followed by a higher result, and X1 results above the mean were more likely to be followed by lower results. A model using population mean, reference interval dispersion, and result diagnostic variation provided a good fit with the data sets, and the derived equation predicted the changes seen. CONCLUSIONS: We have demonstrated that the position of X1 within the reference interval creates an asymmetrical RCV. This can be described as a regression to the population mean. Adding this concept to the theory of RCVs will be an important consideration in many cases.
Assuntos
Sódio , Humanos , Valores de Referência , Sódio/sangue , Cálcio/sangueRESUMO
Long coronavirus disease 2019 (COVID-19)-a postacute consequence of severe acute respiratory syndrome coronavirus 2 infection-manifests with a broad spectrum of relapsing and remitting or persistent symptoms as well as varied levels of organ damage, which may be asymptomatic or present as acute events such as heart attacks or strokes and recurrent infections, hinting at complex underlying pathogenic mechanisms. Central to these symptoms is vascular dysfunction rooted in thrombotic endothelialitis. We review the scientific evidence that widespread endothelial dysfunction (ED) leads to chronic symptomatology. We briefly examine the molecular pathways contributing to endothelial pathology and provide a detailed analysis of how these cellular processes underpin the clinical picture. Noninvasive diagnostic techniques, such as flow-mediated dilation and peripheral arterial tonometry, are evaluated for their utility in identifying ED. We then explore mechanistic, cellular-targeted therapeutic interventions for their potential in treating ED. Overall, we emphasize the critical role of cellular health in managing Long COVID and highlight the need for early intervention to prevent long-term vascular and cellular dysfunction.
RESUMO
Analytical performance specifications (APS) are used for the quantitative assessment of assay analytical performance, with the aim of providing information appropriate for clinical care of patients. One of the major locations where APS are used is in the routine clinical laboratory. These may be used to assess and monitor assays in a range of settings including method selection, method verification or validation, external quality assurance, internal quality control and assessment of measurement uncertainty. The aspects of assays that may be assessed include imprecision, bias, selectivity, sample type, analyte stability and interferences. This paper reviews the practical use of APS in a routine clinical laboratory, using the laboratory I supervise as an example.
Assuntos
Laboratórios Clínicos , Controle de Qualidade , Humanos , Laboratórios Clínicos/normas , Técnicas de Laboratório Clínico/normasRESUMO
OBJECTIVES: Laboratory results are increasingly interpreted against common reference intervals (CRIs), published clinical decision limits, or previous results for the same patient performed at different laboratories. However, there are no established systems to determine whether current analytical performance justifies these interpretations. We analysed data from a likely commutable external quality assurance program (EQA) to assess these interpretations. METHODS: The use of CRIs was assessed by evaluating instrument group medians against minimum specifications for bias. The use of clinical decision limits was assessed using specifications from professional bodies, and the monitoring of patients by testing at different laboratories was assessed by comparing all-laboratory imprecision to within-subject biological variation. RESULTS: Five of the 18 analytes with Australasian CRIs did not meet specification for all instrument groups. Among these, calcium and magnesium failed for one instrument group out of seven, while bicarbonate, chloride, and lipase failed for two instrument groups. Of the 18 analytes reviewed currently without CRIs in Australasia, 10 candidates were identified. Among analytes with clinical decision limits, i.e. lipids, glucose, and vitamin D, only triglycerides met both bias and imprecision specifications, while vitamin D met the imprecision specification. Monitoring patients by testing at different laboratories was supported for 15 of the 46 (33â¯%) analyte-method principles groups that met minimum imprecision specifications. CONCLUSIONS: Analysis of data from commutable EQA programs can provide a mechanism for monitoring whether analytical performance justifies the interpretations made in contemporary laboratory practice. EQA providers should establish systems for routinely providing this information to the laboratory community.
Assuntos
Garantia da Qualidade dos Cuidados de Saúde , Humanos , Valores de Referência , Garantia da Qualidade dos Cuidados de Saúde/normas , Laboratórios Clínicos/normas , Controle de QualidadeRESUMO
Analytical performance specifications (APS) are used for decisions about the required analytical quality of pathology tests to meet clinical needs. The Milan models, based on clinical outcome, biological variation, or state of the art, were developed to provide a framework for setting APS. An approach has been proposed to assign each measurand to one of the models based on a defined clinical use, physiological control, or an absence of quality information about these factors. In this paper we propose that in addition to such assignment, available information from all models should be considered using a risk-based approach that considers the purpose and role of the actual test in a clinical pathway and its impact on medical decisions and clinical outcomes in addition to biological variation and the state-of-the-art. Consideration of APS already in use and the use of results in calculations may also need to be considered to determine the most appropriate APS for use in a specific setting.
Assuntos
Controle de Qualidade , Humanos , Técnicas de Laboratório Clínico/normas , Modelos TeóricosRESUMO
Analytical performance specifications (APS) based on outcomes refer to how 'good' the analytical performance of a test needs to be to do more good than harm to the patient. Analytical performance of a measurand affects its clinical performance. Without first setting clinical performance requirements, it is difficult to define how good analytically the test needs to be to meet medical needs. As testing is indirectly linked to health outcomes through clinical decisions on patient management, often simulation-based studies are used to assess the impact of analytical performance on the probability of clinical outcomes which is then translated to Model 1b APS according to the Milan consensus. This paper discusses the related key definitions, concepts and considerations that should assist in finding the most appropriate methods for deriving Model 1b APS. We review the advantages and limitations of published methods and discuss the criteria for transferability of Model 1b APS to different settings. We consider that the definition of the clinically acceptable misclassification rate is central to Model 1b APS. We provide some examples and guidance on a more systematic approach for first defining the clinical performance requirements for tests and we also highlight a few ideas to tackle the future challenges associated with providing outcome-based APS for laboratory testing.
Assuntos
Técnicas de Laboratório Clínico , Humanos , Técnicas de Laboratório Clínico/normasRESUMO
Troponin is an important diagnostic tool, however, as the assay sensitivity and frequency of testing has increased in the COVID-19 era, a new cohort of patients with persistently elevated troponin has emerged. Interfering antibodies should be considered in patients with persistent and stable troponin elevation, where there is no ongoing cause.
Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/sangue , COVID-19/diagnóstico , Masculino , Feminino , Biomarcadores/sangue , Troponina/sangue , Pessoa de Meia-Idade , IdosoRESUMO
BACKGROUND: Elevated serum urate levels are associated with progression of chronic kidney disease. Whether urate-lowering treatment with allopurinol can attenuate the decline of the estimated glomerular filtration rate (eGFR) in patients with chronic kidney disease who are at risk for progression is not known. METHODS: In this randomized, controlled trial, we randomly assigned adults with stage 3 or 4 chronic kidney disease and no history of gout who had a urinary albumin:creatinine ratio of 265 or higher (with albumin measured in milligrams and creatinine in grams) or an eGFR decrease of at least 3.0 ml per minute per 1.73 m2 of body-surface area in the preceding year to receive allopurinol (100 to 300 mg daily) or placebo. The primary outcome was the change in eGFR from randomization to week 104, calculated with the Chronic Kidney Disease Epidemiology Collaboration creatinine equation. RESULTS: Enrollment was stopped because of slow recruitment after 369 of 620 intended patients were randomly assigned to receive allopurinol (185 patients) or placebo (184 patients). Three patients per group withdrew immediately after randomization. The remaining 363 patients (mean eGFR, 31.7 ml per minute per 1.73 m2; median urine albumin:creatinine ratio, 716.9; mean serum urate level, 8.2 mg per deciliter) were included in the assessment of the primary outcome. The change in eGFR did not differ significantly between the allopurinol group and the placebo group (-3.33 ml per minute per 1.73 m2 per year [95% confidence interval {CI}, -4.11 to -2.55] and -3.23 ml per minute per 1.73 m2 per year [95% CI, -3.98 to -2.47], respectively; mean difference, -0.10 ml per minute per 1.73 m2 per year [95% CI, -1.18 to 0.97]; P = 0.85). Serious adverse events were reported in 84 of 182 patients (46%) in the allopurinol group and in 79 of 181 patients (44%) in the placebo group. CONCLUSIONS: In patients with chronic kidney disease and a high risk of progression, urate-lowering treatment with allopurinol did not slow the decline in eGFR as compared with placebo. (Funded by the National Health and Medical Research Council of Australia and the Health Research Council of New Zealand; CKD-FIX Australian New Zealand Clinical Trials Registry number, ACTRN12611000791932.).
Assuntos
Alopurinol/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Nefropatias Diabéticas/tratamento farmacológico , Inibidores Enzimáticos/uso terapêutico , Taxa de Filtração Glomerular/efeitos dos fármacos , Supressores da Gota/uso terapêutico , Ácido Úrico/sangue , Xantina Oxidase/antagonistas & inibidores , Idoso , Alopurinol/efeitos adversos , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/fisiopatologia , Nefropatias Diabéticas/fisiopatologia , Progressão da Doença , Método Duplo-Cego , Inibidores Enzimáticos/efeitos adversos , Feminino , Supressores da Gota/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/tratamento farmacológico , Insuficiência Renal Crônica/fisiopatologia , Sistema Renina-Angiotensina , Falha de TratamentoRESUMO
BACKGROUND: Biological variation (BV) data may be used to develop analytical performance specifications (APS), reference change values (RCV), and support the applicability of population reference intervals. This study estimates within-subject BV (CVI) for several endocrine biomarkers using 3 different methodological approaches. METHODS: For the direct method, 30 healthy volunteers were sampled weekly for 10 consecutive weeks. Samples were analyzed in duplicate for 17-hydroxyprogesterone (17-OHP), androstenedione, cortisol, cortisone, estradiol, follicle-stimulating hormone (FSH), luteinizing hormone (LH), sex hormone-binding globulin (SHBG), and testosterone. A CV-ANOVA with outlier removal and a Bayesian model were applied to derive the CVI. For estradiol, FSH and LH, only the male subgroup was included. In the indirect method, using the same analytes and groups, pairs of sequential results were extracted from the laboratory information system. The total result variation for individual pairs was determined by identifying a central gaussian distribution in the ratios of the result pairs. The CVI was then estimated by removing the effect of analytical variation. RESULTS: The estimated CVI from the Bayesian model (µCVP(i)) in the total cohort was: 17-OHP, 23%; androstenedione, 20%; cortisol, 18%; cortisone, 11%; SHBG, 7.4%; testosterone, 16%; and for the sex hormones in men: estradiol, 14%; FSH, 8%; and LH, 26%. CVI-heterogeneity was present for most endocrine markers. Similar CVI data were estimated using the CV-ANOVA and the indirect method. CONCLUSIONS: Similar CVI data were obtained using 2 different direct and one indirect method. The indirect approach is a low-cost alternative ensuring implementation of CVI data applicable for local conditions.
Assuntos
Androstenodiona , Cortisona , Masculino , Humanos , Hidrocortisona , Teorema de Bayes , Hormônios Esteroides Gonadais , Hormônio Luteinizante , Hormônio Foliculoestimulante , Estradiol , Esteroides , Testosterona , Globulina de Ligação a Hormônio SexualRESUMO
Reference intervals are established either by direct or indirect approaches. Whereas the definition of direct is well established, the definition of indirect is still a matter of debate. In this paper, a general definition that covers all indirect models presently in use is proposed. With the upcoming popularity of indirect models, it has become evident that further partitioning strategies are required to minimize the risk of patients' false classifications. With indirect methods, such partitions are much easier to execute than with direct methods. The authors believe that the future of reference interval estimation belongs to indirect models with big data pools either from one laboratory or combined from several regional centres (if necessary). Independent of the approach applied, the quality assurance of the pre-analytical and analytical phase, considering biological variables and other confounding factors, is essential.
Assuntos
Big Data , Laboratórios , Humanos , Valores de ReferênciaRESUMO
OBJECTIVES: In clinical practice, steroid measurements are performed mainly by direct, non-extraction immunoassays adapted to high throughput, automated immunoassay platforms and employing secondary calibrators. The accuracy of such steroid immunoassays is limited by cross-reactivity with structurally related steroids and nonspecific matrix interference as well as the metrological traceability of manufacturer supplied calibrators. The accuracy of steroid immunoassay calibrators has been little investigated by independent chemical methods. METHODS: Steroid concentrations of 41 calibrators (4-6 replicates per calibrator) supplied by four manufacturers for use in testosterone (T), estradiol (E2), and progesterone (P4) commercial immunoassays were measured by ultra-pressure liquid chromatography-mass spectrometry (UPLC-MS). RESULTS: Among 14 non-zero T calibrators, six (43â¯%) deviated significantly from the label concentration with 29â¯% outside 20â¯% of it. Among 14 E2 calibrators, eight (57â¯%) deviated significantly, whereas seven (50â¯%) were outside 20â¯% of the label concentration. Among 11 P4 calibrators, eight (73â¯%) deviated significantly whereas four (36â¯%) were outside within 20â¯% of the label concentration. CONCLUSIONS: We conclude that inaccurate calibration of manufacturer's supplied standards may contribute to inaccuracy of commercial direct steroid immunoassays.
Assuntos
Estradiol , Testosterona , Humanos , Cromatografia Líquida/métodos , Progesterona , Calibragem , Espectrometria de Massas em Tandem/métodos , Esteroides , ImunoensaioRESUMO
BACKGROUND: Risk factors for severe COVID-19 include older age, male sex, obesity, black or Asian ethnicity and underlying medical conditions. Whether these factors also influence susceptibility to developing COVID-19 is uncertain. METHODS: We undertook a prospective, population-based cohort study (COVIDENCE UK) from 1 May 2020 to 5 February 2021. Baseline information on potential risk factors was captured by an online questionnaire. Monthly follow-up questionnaires captured incident COVID-19. We used logistic regression models to estimate multivariable-adjusted ORs (aORs) for associations between potential risk factors and odds of COVID-19. RESULTS: We recorded 446 incident cases of COVID-19 in 15 227 participants (2.9%). Increased odds of developing COVID-19 were independently associated with Asian/Asian British versus white ethnicity (aOR 2.28, 95% CI 1.33 to 3.91), household overcrowding (aOR per additional 0.5 people/bedroom 1.26, 1.11 to 1.43), any versus no visits to/from other households in previous week (aOR 1.31, 1.06 to 1.62), number of visits to indoor public places (aOR per extra visit per week 1.05, 1.02 to 1.09), frontline occupation excluding health/social care versus no frontline occupation (aOR 1.49, 1.12 to 1.98) and raised body mass index (BMI) (aOR 1.50 (1.19 to 1.89) for BMI 25.0-30.0 kg/m2 and 1.39 (1.06 to 1.84) for BMI >30.0 kg/m2 versus BMI <25.0 kg/m2). Atopic disease was independently associated with decreased odds (aOR 0.75, 0.59 to 0.97). No independent associations were seen for age, sex, other medical conditions, diet or micronutrient supplement use. CONCLUSIONS: After rigorous adjustment for factors influencing exposure to SARS-CoV-2, Asian/Asian British ethnicity and raised BMI were associated with increased odds of developing COVID-19, while atopic disease was associated with decreased odds. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Registry (NCT04330599).
Assuntos
COVID-19 , COVID-19/epidemiologia , Estudos de Coortes , Humanos , Estudos Longitudinais , Masculino , Estudos Prospectivos , Fatores de Risco , SARS-CoV-2 , Reino Unido/epidemiologiaRESUMO
Hypertension is a major risk factor for kidney and cardiovascular disease. The treatment of hypertensive individuals by selected ACE inhibitors and certain di-and tripeptides halts the progression of renal deterioration and extends life-span. Renal reabsorption of these low molecular weight substrates are mediated by the PEPT1 and PEPT2 cotransporters. This study aims to investigate whether hypertension and ageing affects renal PEPT cotransporters at gene, protein expression and distribution as well as function in the superficial cortex and the outer medulla of the kidney. Membrane vesicles from the brush border (BBMV) and outer medulla (OMMV) were isolated from the kidneys of young Wistar Kyoto (Y-WKY), young spontaneously hypertensive (Y-SHR), and middle aged SHR (M-SHR) rats. Transport activity was measured using the substrate, ß-Ala-Lys (AMCA). Gene expression levels of PEPT genes were assessed with qRT-PCR while renal localisation of PEPT cotransporters was examined by immunohistochemistry with Western Blot validation. The Km and Vmax of renal PEPT1 were decreased significantly in SHR compared to WKY BBMV, whilst the Vmax of PEPT2 showed differences between SHR and WKY. By contrast to the reported cortical distribution of PEPT1, PEPT1-staining was detected in the outer medulla, whilst PEPT2 was expressed primarily in the cortex of all SHR; PEPT1 was significantly upregulated in the cortex of Y-SHR. These outcomes are indicative of a redistribution of PEPT1 and PEPT2 in the kidney proximal tubule under hypertensive conditions that has potential repercussions for nutrient handling and the therapeutic use of ACE inhibitors in hypertensive individuals.
Assuntos
Hipertensão , Simportadores , Inibidores da Enzima Conversora de Angiotensina , Animais , Hipertensão/genética , Hipertensão/metabolismo , Rim/metabolismo , Transportador 1 de Peptídeos/genética , Transportador 1 de Peptídeos/metabolismo , Peptídeos/metabolismo , Ratos , Ratos Endogâmicos SHR , Ratos Endogâmicos WKY , Roedores/metabolismo , Simportadores/genética , Simportadores/metabolismoRESUMO
ABSTRACT: Individualization of vancomycin dosing based on therapeutic drug monitoring (TDM) data is known to improve patient outcomes compared with fixed or empirical dosing strategies. There is increasing evidence to support area-under-the-curve (AUC24)-guided TDM to inform vancomycin dosing decisions for patients receiving therapy for more than 48 hours. It is acknowledged that there may be institutional barriers to the implementation of AUC24-guided dosing, and additional effort is required to enable the transition from trough-based to AUC24-based strategies. Adequate documentation of sampling, correct storage and transport, accurate laboratory analysis, and pertinent data reporting are required to ensure appropriate interpretation of TDM data to guide vancomycin dosing recommendations. Ultimately, TDM data in the clinical context of the patient and their response to treatment should guide vancomycin therapy. Endorsed by the International Association of Therapeutic Drug Monitoring and Clinical Toxicology, the IATDMCT Anti-Infectives Committee, provides recommendations with respect to best clinical practice for vancomycin TDM.
Assuntos
Anti-Infecciosos , Vancomicina , Antibacterianos , Área Sob a Curva , Monitoramento de Medicamentos/métodos , HumanosRESUMO
The role of an External Quality Assurance (EQA) program is generally seen as providing a service to routine laboratories that their analytical performance is satisfactory and stimulating corrective action in the event of poor results. It is recognised that an ideal EQA program uses materials that are commutable with patient samples and have values assigned by higher-order reference methods. Despite this, most routine EQA programs use materials without verified commutability and use consensus means (based on either peer group or all laboratories) as target values. We propose an ongoing role for EQA programs using non-commutable materials and consensus targets to support the measurement services of routine laboratories. This is provided the relevant comparators supplied by the laboratory, e.g. reference intervals and clinical decision points, are based on the same or equivalent measurement system as is used by the laboratory. Materials without verified commutability often have certain practical advantages, which may include the range of analyte concentrations, verified stability, replicate samples and, significantly, lower costs. Laboratories using such programs need to be aware of the limitations, especially comparing results from different measurement systems. However, we also recognise that as well as individual laboratories, data from EQA programs informs manufacturers, professional organisations, clinical guideline writers and other medical bodies For consideration beyond an individual laboratory, proper assessment of differences between measurement systems (results harmonization) and demonstration of correct implementation of metrological traceability (methods trueness) become vital, and for that purpose, commutability of EQA materials and traceability of target values are required.
Assuntos
Laboratórios , Humanos , Controle de Qualidade , Padrões de ReferênciaRESUMO
OBJECTIVES: To assess interlaboratory variability of total serum bilirubin (TSB) results in newborns. Initiated following a clinical incident in which a neonate was transferred to a tertiary hospital for treatment of severe hyperbilirubinemia but on arrival was reclassified into a lower risk category due to a 20% difference in TSB between laboratories. METHODS: Fresh residual plasma samples from hospital-born infants were pooled to obtain 11 samples across a range of total bilirubin concentrations. Aliquots were light-protected and measured on 7 commercial platforms at 4 accredited medical laboratories. Data from The Royal College of Pathologists of Australasia Quality Assurance Programs' (RCPAQAP) Neonatal Bilirubin program was analysed. RESULTS: Twenty-four to 30% difference in results for individual samples, largely due to calibration differences between assays. When interpreted according to guidelines, results from different platforms would have led to different clinical interventions in some cases. RCPAQAP results showed significant within-method bias but were not shown to be commutable with patient samples. CONCLUSIONS: There are clinically significant method-dependent differences in TSB results from neonatal samples, consistent with our clinical incident. The differences are largely due to lack of standardisation of calibrator values. This has implications for healthcare resource use and possibly for the neurodevelopment of infants. Intervention is needed at a number of levels, including clinical reporting of incidents arising from discordant results, commitment by manufacturers to ensure metrological traceability of methods with sufficiently low uncertainty in the final measurements, and availability of commutable quality assurance material to monitor assay performance, especially at the clinical decision points for neonatal jaundice.
Assuntos
Hiperbilirrubinemia Neonatal , Icterícia Neonatal , Bilirrubina , Calibragem , Humanos , Hiperbilirrubinemia Neonatal/diagnóstico , Hiperbilirrubinemia Neonatal/terapia , Lactente , Recém-Nascido , Icterícia Neonatal/terapia , Padrões de ReferênciaRESUMO
Exercise-induced bronchoconstriction (EIBc) is a recognised response to exercise in asthmatic subjects and athletes but is less well understood in an unselected broad population. Exercise-induced bronchodilation (EIBd) has received even less attention. The objective of this study was to investigate the effects of age, sex, forced expiratory volume in 1â s (FEV1) and airflow limitation (FEV1/forced vital capacity (FVC) <0.7) on the prevalence of EIBc and EIBd.This was a retrospective study based on incremental cardiopulmonary exercise testing on cycle ergometry to symptom limitation performed between 1988 and 2012. FEV1 was measured before and 10â min after exercise. EIBc was defined as a percentage fall in FEV1 post-exercise below the 5th percentile, while EIBd was defined as a percentage increase in FEV1 above the 95th percentile.35â258 subjects aged 6-95â years were included in the study (mean age 53â years, 60% male) and 10.3% had airflow limitation (FEV1/FVC <0.7). The lowest 5% of subjects demonstrated a ≥7.6% fall in FEV1 post-exercise (EIBc), while the highest 5% demonstrated a >11% increase in FEV1 post-exercise (EIBd). The probability of both EIBc and EIBd increased with age and was highest in females across all ages (OR 1.76, 95% CI 1.60-1.94; p<0.0001). The probability of EIBc increased as FEV1 % pred declined (<40%: OR 4.38, 95% CI 3.04-6.31; p<0.0001), with a >2-fold increased likelihood in females (OR 2.31, 95% CI 1.71-3.11; p<0.0001), with a trend with airflow limitation (p=0.06). The probability of EIBd increased as FEV1 % pred declined, in the presence of airflow limitation (OR 1.55, 95% CI 1.24-1.95; p=0.0001), but sex had no effect.EIBc and EIBd can be demonstrated at the population level, and are influenced by age, sex, FEV1 % pred and airflow limitation.
Assuntos
Broncoconstrição , Pulmão , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Testes de Função Respiratória , Estudos Retrospectivos , Espirometria , Capacidade VitalRESUMO
Some dipeptides have been implicated in myocardial protection, but little is known about their membrane transporter PEPT2. The aim of this study was to determine whether the expression and activity of the cardiac-type PEPT2 cotransporter could be affected by ageing and/or hypertension. Sarcolemmal vesicles (SV) were isolated from the hearts of all rat groups using a standard procedure to investigate the transport activity and protein abundance by fluorescence spectroscopy and Western blot, respectively. SLC15A2 "PEPT2" gene expression was relatively quantified by RT-qPCR. In the Wistar rat groups, the protein and gene expression of PEPT2 were upregulated with ageing. These changes were accompanied by corresponding increases in the competitive inhibition and the transport rate (Vmax) of ß-Ala-Lys (AMCA) into SV isolated from middle-aged hearts. Although, the transport rate of ß-Ala-Lys (AMCA) into SV isolated from old hearts was significantly the lowest compared to middle-aged and young adult hearts, the inhibition percentage of ß-Ala-Lys (AMCA) transport by Gly-Gln was the highest. In the WKY and SHR rat groups, Y-SHR hypertrophied hearts showed an increase in PEPT2 gene expression accompanied by a significant decrease in protein expression and activity. With advanced age, however, M-SHR hypertrophied hearts revealed significantly lower gene expression, but higher protein expression and activity than Y-SHR hearts. These findings suggest that increased expression of PEPT2 cotransporter in all types of middle-aged hearts could be exploited to facilitate di-and tripeptide transport by PEPT2 in these hearts, which subsequently could result in improved myocardial protection in these populations.
Assuntos
Envelhecimento/metabolismo , Cardiomegalia/metabolismo , Hipertensão/metabolismo , Simportadores/metabolismo , Animais , Transporte Biológico , Cardiomegalia/genética , Dipeptídeos/metabolismo , Hipertensão/genética , Masculino , Ratos , Ratos Endogâmicos SHR , Ratos Endogâmicos WKY , Simportadores/genéticaRESUMO
This article focuses on the problem of estimating a species tree from multilocus data in the presence of incomplete lineage sorting and migration. I develop a mathematical model similar to IMa2 (Hey 2010) for the relevant evolutionary processes which allows both the population size parameters and the migration rates between pairs of species tree branches to be integrated out. I then describe a BEAST2 package DENIM (Divergence estimation notwithstanding ILS and migration) which is based on this model and which uses an approximation to sample from the posterior. The approximation is based on the assumption that migrations are rare, and it only samples from certain regions of the posterior which seem likely given this assumption. The method breaks down if there is a lot of migration. Using simulations, Leaché et al. (2014) showed that using the standard multispecies coalescent model to infer a species tree can result in poor accuracy if migration is present. I reanalyze this simulated data to explore DENIM's performance and demonstrate substantial improvements in accuracy over *BEAST. I also reanalyze an empirical data set.
Assuntos
Evolução Biológica , Classificação/métodos , Modelos Biológicos , Simulação por Computador , Densidade DemográficaRESUMO
Elaboration of Bayesian phylogenetic inference methods has continued at pace in recent years with major new advances in nearly all aspects of the joint modelling of evolutionary data. It is increasingly appreciated that some evolutionary questions can only be adequately answered by combining evidence from multiple independent sources of data, including genome sequences, sampling dates, phenotypic data, radiocarbon dates, fossil occurrences, and biogeographic range information among others. Including all relevant data into a single joint model is very challenging both conceptually and computationally. Advanced computational software packages that allow robust development of compatible (sub-)models which can be composed into a full model hierarchy have played a key role in these developments. Developing such software frameworks is increasingly a major scientific activity in its own right, and comes with specific challenges, from practical software design, development and engineering challenges to statistical and conceptual modelling challenges. BEAST 2 is one such computational software platform, and was first announced over 4 years ago. Here we describe a series of major new developments in the BEAST 2 core platform and model hierarchy that have occurred since the first release of the software, culminating in the recent 2.5 release.