Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Rev Cardiovasc Med ; 23(7): 224, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39076911

RESUMO

Background: Patients with severe aortic valve stenosis (AS) frequently present with pulmonary hypertension (PH). The gold standard for detection of pulmonary hypertension is right heart catheterization, which is not routinely performed as a preoperative standard in cardiology centers today, neither before surgical valve replacement nor before transcatheter aortic valve replacement (TAVR) procedure. Echocardiographic determination of systolic pulmonary artery pressure (sPAP) provides an opportunity to assess the presence or absence of PH. The aim of the present study was to investigate the extent to which plasma levels of common cardiovascular biomarkers behave in patients with severe AS and an sPAP < 40 mmHg in comparison to patients with an sPAP ≥ 40 mmHg. Methods: 179 patients with echocardiographic evidence of severe AS before TAVR procedure were divided into 2 groups based on sPAP. An sPAP of 40 mmHg was considered the cut-off value, with absence of PH defined by an sPAP < 40 mmHg (n = 82) and presence of PH defined by an sPAP ≥ 40 mmHg (n = 97). Directly before TAVR, a blood sample was drawn from each patient, and plasma concentrations of the cardiovascular biomarkers Soluble Suppression of Tumorigenicity-2 (sST2), Growth/Differentiation of Factor-15 (GDF-15), Heart-Type Fatty-Acid Binding Protein (H-FABP), Insulin Like Growth Factor Binding Protein 2 (IGF-BP2), Soluble Urokinase-Type Plasminogen Activator Receptor (suPAR), Brain Natriuretic Peptide (BNP) and Cardiac Troponin I (cTnI) were determined. Results: Patients with an sPAP ≥ 40 mmHg had significantly higher sST2 (p = 0.010), GDF-15 (p = 0.005), IGF-BP2 (p = 0.029), suPAR (p = 0.018), BNP (p < 0.001) and cTnI (p = 0.039) plasma levels. Only for H-FABP (p = 0.069), no significant differences were discernible between the two groups. In addition, cut-off values were calculated to predict an sPAP ≥ 40 mmHg. Significant results were shown with 16045.84 pg/mL for sST2 (p = 0.010), with 1117.54 pg/mL for GDF-15 (p = 0.005), with 107028.43 pg/mL for IGF-BP2 (p = 0.029), with 3782.84 pg/mL for suPAR (p = 0.018), with 2248.00 pg/mL for BNP (p < 0.001) and with 20.50 pg/mL for cTnI (p = 0.002). Conclusions: sPAP as an echocardiographic parameter in combination with supplementary use of cardiovascular biomarkers presented here have the potential to provide more detailed information about the presence or absence of PH in a non-invasive way.

2.
J Clin Lab Anal ; 35(11): e23977, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34562276

RESUMO

BACKGROUND: Systemic inflammation has been identified as a major cardiovascular risk factor in patients undergoing transcatheter aortic valve replacement (TAVR), yet currently, it is not adequately portrayed in scores for pre-interventional risk assessment. The aim of this study was to investigate the predictive ability of TNF-α in TAVR. METHODS: A total of 431 patients undergoing transfemoral TAVR were enrolled in this study. Blood samples were drawn prior to intervention, 24 h post-intervention, 4, 5, and 7 days post-intervention, and 1, 3, and 6 months post-TAVR. RESULTS: In a univariate Cox proportional hazard analysis, plasma concentrations of TNF-α after 24 h and after 5 days were associated with mortality after 12 months (after 24 h: HR 1.002 (1.000-1.004), p = 0.028; after 5d: HR 1.003 (1.001-1.005), p = 0.013). This association remained significant even after correction for confounders in a multivariate Cox regression analysis. Additionally, cut-offs were calculated. Patients above the cut-off for TNF-α after 5d had a significantly worse 12-month mortality than patients below the cut-off (18.8% vs. 2.8%, p = 0.046). CONCLUSION: Plasma levels of TNF-α after 24 h and 5 days were independently associated with 12-month mortality in patients undergoing TAVR. Thus, TNF-α could represent a novel biomarker for enhanced risk stratification in these patients.


Assuntos
Substituição da Valva Aórtica Transcateter , Fator de Necrose Tumoral alfa/sangue , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Feminino , Humanos , Inflamação , Masculino , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade
3.
Heart Vessels ; 34(6): 976-983, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30535754

RESUMO

Peripheral arterial disease (PAD) is one of the most common manifestations of systemic atherosclerosis. The prevalence of unrecognized PAD is high, leading to a lack of opportunity to detect subjects at a high risk for cardiovascular events. Inflammatory processes play an important role in the disease initiation as well as in the disease progression. Vascular cell adhesion molecule 1 (VCAM-1), a biomarker of endothelial dysfunction, appears to be an important mediator in inflammatory processes. Therefore, we hypothesized that in patients with PAD, circulating VCAM-1 might be elevated due to its function in mediating adhesion of immune cells to the vascular endothelium in the process of endothelial dysfunction and inflammation, and, therefore, applicable as a diagnostic biomarker. A total of 126 non-consecutive patients were enrolled in this study, of whom 51 patients had typical clinical manifestations of PAD and as controls 75 patients with no history of PAD or cardiovascular disease. All serum samples were obtained either during hospitalization or during out-patient visits and analyzed for VCAM-1 by the ELISA. Compared with controls, median levels of VCAM-1 were significantly elevated in patients suffering from PAD (953 vs. 1352 pg/ml; p < 0.001). Furthermore, VCAM-1 appeared to be highly discriminative for the detection of PAD (AUC = 0.76; CI 0.67-0.83). We could not observe dynamics related to increasing disease stages according to Rutherford classes in patients with apparent PAD. VCAM-1 was shown to be a potential discriminator and biomarker for the severity of systemic atherosclerosis. In a logistic regression analysis, VCAM-1 was robustly associated with the diagnosis of PAD, even after correction for clinically relevant cofounders (namely age, arterial hypertension, diabetes and LDL levels). Thusly, VCAM-1 might serve as a biomarker for PAD screening and detection.


Assuntos
Endotélio Vascular/fisiopatologia , Doença Arterial Periférica/sangue , Molécula 1 de Adesão de Célula Vascular/sangue , Idoso , Biomarcadores/sangue , Feminino , Humanos , Inflamação/sangue , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos
4.
J Electrocardiol ; 55: 72-77, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31146075

RESUMO

BACKGROUND: Leadless pacemaker technology is a promising upcoming field in clinical rhythmology. Today, the most commonly used system in the clinical setting is the Micra™ leadless pacemaker system (Medtronic). In autopsies of patients who witnessed non-pacemaker associated death, unexpected ingrowth/encapsulation within the wall of the right ventricle was reported. The occurrence of a complete encapsulation was not expected and the process of endothelialisation remains unclear. We hypothesized, that a local inflammatory response might be the cause of these findings. The aim of our experimental in-vitro study was to investigate the effect of the Micra™ system and its single components on inflammatory processes. METHODS: For this purpose, whole Micra™ pacemakers were incubated in heparin plasma from 25 healthy volunteers for 48 h at 37 °C. Furthermore, 1 g gold, steel, titanium, tungsten and nitinol wires were incubated in heparin plasma for 48 h at 37 °C as well (n = 10). To detect eventual inflammatory processes, interleukin- (IL) 1ß, IL-6, and tumor necrosis factor alpha (TNF-α), the chemokine IL-8 were measured using enzyme-linked immunosorbent assay (ELISA). Additionally, the level of transforming growth factor beta 1 (TGF-ß1) and vascular endothelial growth factor (VEGF) were analysed. RESULTS: ELISA analyses showed that the whole Micra system leads to a significant increase in the inflammatory cytokine IL-6 which correlates with the data gained by the incubation of whole blood with the different wires. In particular, 0.5 g of tungsten showed a significant rise of IL-6 which could also be found for IL-1ß and IL-8. CONCLUSIONS: The in vitro study of the Micra system showed that the material composition led to an onset of inflammatory processes in whole blood. Consequently, one may speculate that the composition of Micra pacemaker may have a local inflammatory, though subclinical, effects in patients implanted with a Micra™ pacemakers.


Assuntos
Endotélio Vascular , Marca-Passo Artificial , Eletrocardiografia , Desenho de Equipamento , Humanos , Interleucinas , Próteses e Implantes , Fator de Crescimento Transformador beta1 , Fator A de Crescimento do Endotélio Vascular
5.
Eur J Clin Invest ; 47(2): 149-157, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28036122

RESUMO

BACKGROUND: Soluble ST2 (sST2) has been introduced as a novel biomarker in patients suffering from heart failure for risk stratification. In this study, we sought to investigate whether sST2 is useful for risk stratification and prediction of mortality in patients undergoing transcatheter aortic valve implantation (TAVI). MATERIALS AND METHODS: A total of 274 patients undergoing TAVI were included in this study (149 female; age 81 ± 1 years; EUROSCORE 25 ± 1; STS score 3·8 ± 0·2). Plasma samples were obtained preinterventional and analysed for sST2. Patients were followed up 1 month and 1 year after TAVI. RESULTS: In a Cox regression analysis, sST2 plasma concentration was associated with increased mortality (changes per pg/mL sST2 concentration; HR 1·00006 95% (1·00004-1·00009); P < 0·001). A cut-off by means of the Youden Index was calculated (10 070·27 pg/mL), and patients were retrospectively divided into two cohorts, in those above (31·3%) and those below (68·7%) this value. These two groups were then compared regarding mortality both after 30 days and 1 year: whereas 1-month mortality did not differ (7·0% vs. 10·3%, OR 1·50 95% CI (0·60-3·79; P = 0·46)), patients with a sST2 concentration above the cut-off of 10 070·27 pg/mL showed a significantly worse outcome after 1 year (49·2% vs. 23·2%; OR 3·21 95% CI (1·70-6·04); P < 0·001). After correction for confounders in a multivariate Cox regression analysis, sST2 (1·0002 95% CI (1·0001-1·0003); P = 0·001) concentration remained associated with mortality. CONCLUSIONS: sST2 levels were associated with 1-year mortality after TAVI. Based on these results, we assume that sST2 might help to identify patients at high risk for death in whom conservative treatment should be considered.


Assuntos
Estenose da Valva Aórtica/cirurgia , Proteína 1 Semelhante a Receptor de Interleucina-1/metabolismo , Substituição da Valva Aórtica Transcateter/mortalidade , Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/mortalidade , Estudos de Coortes , Feminino , Humanos , Masculino , Volume Sistólico/fisiologia , Resultado do Tratamento
6.
Clin Lab ; 62(6): 1061-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27468568

RESUMO

BACKGROUND: Contradictory results of large clinical trials of stem cell therapy in acute myocardial infarction (AMI) have impeded a wider clinical use. As signalling via paracrine factors in AMI has received more and more attention recently, we sought to compare processing protocols with special emphasis on interleukin-6 (IL-6), a factor of major relevance for triggering cardioprotective signals via STAT3 and PI3K. METHODS: Bone marrow and peripheral blood mononuclear cells were processed according to protocols used in the REPAIR-AMI and ASTAMI study. RESULTS: Keeping cells at higher temperatures significantly boosted secretion of IL-6. Moreover, the use of autologous serum and X-Vivo medium was superior over reagents used in the protocol of the ASTAMI study. CONCLUSIONS: External influencing factors (higher temperature, use of a modern cell culture medium supplemented with serum) led to higher concentrations of IL-6. These results could provide an explanation for the superior results found in the REPAIR-AMI study.


Assuntos
Técnicas de Cultura de Células , Ensaios Clínicos como Assunto/métodos , Infarto do Miocárdio/cirurgia , Projetos de Pesquisa , Transplante de Células-Tronco , Células-Tronco/metabolismo , Células Cultivadas , Meios de Cultura/metabolismo , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Interleucina-6/metabolismo , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/metabolismo , Infarto do Miocárdio/fisiopatologia , Transdução de Sinais , Temperatura , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 86(3): E126-30, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26033366

RESUMO

BACKGROUND: Renal denervation (RDN) is a promising treatment option in addition to medical antihypertensive treatment in patients suffering from resistant hypertension. Despite the growing interest in RDN, the negative result of the Symplicity HTN-3 trial led to a debate on the efficacy of RDN. METHODS: We systematically investigated the effects of RDN, evaluated by 24-hr ambulatory blood pressure measurements (ABPM), in a consecutive series of patients with resistant hypertension, which was defined by a mean office systolic blood pressure (SBP) >160 mm Hg (>150 mm Hg in patients with diabetes). Patients with a mean 24-hr SBP of less than 130 mm Hg at baseline were classified as pseudo-resistant, while all other patients were classified as true-resistant. After six months, we analyzed the response rates in true-resistant and in pseudo-resistant patients, respectively, by the means of 24-hr ABPM. Thereby, patients with a reduction of more than 5 mm Hg in 24-hr SBP were classified as responders. RESULTS: RDN was performed in 106 patients. By 24-hr ABPM, 20 patients (18.9%) were classified as pseudo-resistant patients. In this cohort, we only found two responders (response rate 10%) six months after RDN. By contrast, in true-resistant patients, the response rate was almost 60% and the mean BP reduction was -18.6/-9 mm Hg in 24-hr ABPM. CONCLUSIONS: We found a significant BP reduction in almost 60% of patients with true-resistant hypertension, but only in 10% in patients with pseudo-resistant hypertension. According to our results, patient selection seems to be crucial for acceptable response rates after RDN.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Hipertensão/fisiopatologia , Hipertensão/cirurgia , Rim/inervação , Simpatectomia , Resistência Vascular/fisiologia , Adolescente , Adulto , Idoso , Anti-Hipertensivos/uso terapêutico , Comorbidade , Feminino , Humanos , Hipertensão/tratamento farmacológico , Testes de Função Renal , Masculino , Pessoa de Meia-Idade
8.
Pacing Clin Electrophysiol ; 38(3): 302-5, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25469990

RESUMO

BACKGROUND: Active fixation coronary sinus (CS) leads are widely used in cardiac resynchronization therapy (CRT). Due to their low dislodgement rates they are an attractive option for implanters. However, extraction of active fixation leads is a complex procedure that bears potential fatal risks for patients. METHODS: We analyzed all patients undergoing StarFix® (Medtronic Inc., Minneapolis, MN, USA) extraction because of severe infection at our institution. Indication for extraction was severe device infection. Procedural outcomes as well as patient characteristics are reported. For removal of the leads a 9-Fr Evolution® (Cook Intravascular Inc., Leechburg, PA, USA) mechanical rotation extraction sheath was used. RESULTS: Between 2011 and 2014, six patients underwent extraction of StarFix® leads. One patient was female, whereas the others were males (mean age 64 ± 12 years). Implant duration was 46.5 ± 8.2 months before removal. All leads could be successfully extracted totally with the Evolution®. In one patient (16.6%) pericardial tamponade occurred immediately requiring surgical intervention. After establishment of cardiopulmonary bypass a 5-mm sharp cut in the lateral vein of the CS could be identified. It was fixed and the patient survived. On all leads, significant tissue growth between the fixation lobes could be observed. CONCLUSION: As illustrated by our cases, Attain StarFix® leads implanted years ago can be extracted with the help of a mechanical extraction sheath. However, this procedure bears potential risks and should only be performed with a cardiac surgery standby. If clinicians evaluate the implantation of Attain StarFix® leads in patients who are young or at high risk for device infection, they should be aware of these findings.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Seio Coronário/cirurgia , Remoção de Dispositivo/instrumentação , Eletrodos Implantados , Infecções Relacionadas à Prótese/terapia , Idoso , Idoso de 80 Anos ou mais , Seio Coronário/fisiopatologia , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico por imagem , Rotação
9.
Pacing Clin Electrophysiol ; 38(1): 28-34, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25154425

RESUMO

BACKGROUND: Device replacements bear many potential risks for patients. Electrocautery should be used cautiously because of heating of the cautery tip which may lead to insulation melting. The PEAK PlasmaBlade™ (Medtronic Inc., Minneapolis, MN, USA) uses a novel technology to cut tissue. The objective of this study was to evaluate if this instrument is less destructive and can decrease complications and shorten procedure times. METHODS AND RESULTS: Two groups were compared: in group 1, surgery was done with scissors and conventional electrocautery, whereas the PEAK PlasmaBlade™ was used in group 2. Procedure time and complication rates were retrospectively investigated. Group 1 comprised 509 patients, while group 2 consisted of 102 patients. Procedure time in group 2 was significantly shorter with 28.4 ± 8.9 minutes than in group 1 with 47.5 ± 24.5 minutes (P < 0.001). The hospital stay was also reduced (2.1 ± 2.2 days versus 3.1 ± 2.4 days, P < 0.001). One major complication occurred in only 2.4% (two patients) of group 2 and in 6.9% (35 patients) of group 1. There were no damaged leads in group 2 compared to 5.7% in group 1 (P = 0.008). Cost analyses showed that the use of The PEAK PlasmaBlade™ instead of conventional electrocautery resulted in cost savings of €120/patient. CONCLUSION: Device replacement is associated with a notable complication risk. Our investigation showed that a new device for generator replacement resulted in significantly reduced procedure time and length of hospital stay while completely avoiding lead damage, which translated into considerable cost savings in a real world setting.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Remoção de Dispositivo/economia , Remoção de Dispositivo/instrumentação , Eletrocirurgia/economia , Eletrocirurgia/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Análise Custo-Benefício , Remoção de Dispositivo/efeitos adversos , Eletrocirurgia/efeitos adversos , Desenho de Equipamento , Feminino , Recursos em Saúde/estatística & dados numéricos , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
10.
J Electrocardiol ; 46(6): 649-52, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23973092

RESUMO

INTRODUCTION: Left atrial catheter ablation (LACA) is routinely used in the management of recurrent atrial fibrillation. CASE PRESENTATION: We report a patient suffering from vasospastic angina 2 months after a LACA procedure. Typical clinical symptoms, ST-segment changes during exercise test and successful treatment with nicorandil led to the diagnosis. According to our hypothesis, destruction of autonomic ganglia in the left atrium and resulting autonomic nerve tone imbalance might be the main determinants that have caused this phenomenon. CONCLUSION: Coronary spasms even weeks after LACA should draw attention to a possible association with the procedure.


Assuntos
Angina Pectoris/diagnóstico , Angina Pectoris/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Vasoespasmo Coronário/diagnóstico , Vasoespasmo Coronário/etiologia , Eletrocardiografia/métodos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Diagnóstico Diferencial , Exercício Físico , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
11.
J Cardiovasc Dev Dis ; 10(1)2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36661917

RESUMO

(1) Background: Currently, echocardiography is the primary non-invasive diagnostic method used to screen patients with severe aortic valve stenosis (AS) for pulmonary hypertension (PH) by estimating systolic pulmonary artery pressure (sPAP). Other radiological methods have been a focus of research in the past couple of years, as it was shown that by determining the pulmonary artery (PA) diameter, prognostic statements concerning overall mortality could be made in these patients. This study compared established and novel cardiovascular biomarkers with the PA/BSA value to detect PH in patients with severe AS. (2) Methods: The study cohort comprised 188 patients with severe AS undergoing transcatheter aortic valve replacement (TAVR), who were then divided into two groups based on PA/BSA values obtained through CT-angiography. The presence of PH was defined as a PA/BSA ≥ 16.6 mm/m2 (n = 81), and absence as a PA/BSA < 16.6 mm/m2 (n = 107). Blood samples were taken before TAVR to assess cardiovascular biomarkers used in this study, namely brain natriuretic peptide (BNP), cardiac troponin I (cTnI), high-sensitive troponin (hsTN), soluble suppression of tumorigenesis-2 (sST2), growth/differentiation factor 15 (GDF-15), heart-type fatty acid-binding protein (H-FABP), insulin-like growth factor binding protein 2 (IGF-BP2), and soluble urokinase-type plasminogen activator receptor (suPAR). (3) Results: Patients with a PA/BSA ≥ 16.6 mm/m2 showed significantly higher levels of BNP (p = <0.001), GDF-15 (p = 0.040), and H-FABP (p = 0.007). The other investigated cardiovascular biomarkers did not significantly differ between the two groups. To predict a PA/BSA ≥ 16.6 mm/m2, cut-off values for the biomarkers were calculated. Here, GDF-15 (p = 0.029; cut-off 1172.0 pg/mL) and BNP (p < 0.001; cut-off 2194.0 pg/mL) showed significant results. Consequently, analyses of combined biomarkers were performed, which yielded IGF-BP2 + BNP (AUC = 0.721; 95%CI = 0.585−0.857; p = 0.004) as the best result of the two-way analyses and GDF-15 + IGF-BP2 + BNP (AUC = 0.727; 95%CI = 0.590−0.864; p = 0.004) as the best result of the three-way analyses. No significant difference regarding the 1-year survival between patients with PA/BSA < 16.6 mm/m2 and patients with PA/BSA ≥ 16.6 mm/m2 was found (log-rank test: p = 0.452). (4) Conclusions: Although PA/BSA aims to reduce the bias of the PA value caused by different body compositions and sizes, it is still a controversial parameter for diagnosing PH. Combining the parameter with different cardiovascular biomarkers did not lead to a significant increase in the diagnostic precision for detecting PH in patients with severe AS.

12.
Diagnostics (Basel) ; 13(3)2023 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-36766463

RESUMO

Both relevant aortic valve stenosis (AS) and aortic valve insufficiency significantly contribute to structural changes in the ascending aorta (AA) and thus to its dilatation. In patients with severe AS undergoing transcatheter aortic valve replacement (TAVR), survival data regarding aortic changes and laboratory biomarker analyses are scarce. METHODS: A total of 179 patients with severe AS and an available computed tomography were included in this retrospective study. AA was measured, and dilatation was defined as a diameter ≥ 40 mm. Thirty-two patients had dilatation of the AA. A further 32 patients from the present population with a normal AA were matched to the aortic dilatation group with respect to gender, age, body mass index and body surface area, and the resulting study groups were compared with each other. In addition to echocardiographic and clinical characteristics, the expression of cardiovascular biomarkers such as brain natriuretic peptide (BNP), soluble suppression of tumorigenicity-2 (sST2), growth/differentiation of factor-15 (GDF-15), heart-type fatty-acid binding protein (H-FABP), insulin-like growth factor binding protein 2 (IGF-BP2) and soluble urokinase-type plasminogen activator receptor (suPAR) was analyzed. Kaplan-Meier curves for short- and long-term survival were obtained, and Pearson's and Spearman's correlations were calculated to identify the predictors between the diameter of the AA and clinical parameters. RESULTS: A total of 19% of the total cohort had dilatation of the AA. The study group with an AA diameter ≥ 40 mm showed a significantly low comorbidity with respect to diabetes mellitus in contrast to the comparison cohort with an AA diameter < 40 mm (p = 0.010). This result continued in the correlation analyses performed, as the presence of diabetes mellitus correlated negatively not only with the diameter of the AA (r = -0.404; p = 0.001) but also with the presence of aortic dilatation (r = -0.320; p = 0.010). In addition, the presence of AA dilatation after TAVR was shown to have no differences in terms of patient survival at 1, 3 and 5 years. There were no relevant differences in the cardiovascular biomarkers studied between the patients with dilated and normal AAs. CONCLUSION: The presence of AA dilatation before successful TAVR was not associated with a survival disadvantage at the respective follow-up intervals of 1, 3 and 5 years. Diabetes mellitus in general seemed to have a protective effect against the development of AA dilatation or aneurysm in patients with severe AS.

13.
Minerva Med ; 2022 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-35822856

RESUMO

BACKGROUND: Echocardiography is currently the noninvasive method of choice to screen patients with severe aortic valve stenosis (AS) for pulmonary hypertension (PH) by estimating systolic pulmonary artery pressure (sPAP). However, radiological options are also available by determining the main pulmonary artery (MPA) diameter in the setting of CT angiography. The aim of the present study was to compare cardiovascular biomarkers with the MPA diameter to allow other ways of detecting PH in patients with severe AS. METHODS: 194 patients with severe AS undergoing transcatheter aortic valve replacement (TAVR) were included in this study and were divided into two groups based on the CT-angiographically determined MPA diameter. In accordance with ESC guidelines, a cut-off value of 29 mm was determined in this study, with the absence of PH defined by an MPA diameter < 29 mm (n = 79/194) and the presence of PH defined by an MPA diameter ≥ 29 mm (115/194). Immediately before interventional aortic valve replacement, blood samples were drawn from the subjects and relevant cardiovascular biomarkers such as BNP, cTnI, GDF-15, H-FABP, IGF-BP2 and suPAR were assessed. RESULTS: Patients with an MPA diameter ≥ 29 mm had significantly higher BNP (p = 0.004), cTnI (p = 0.039) and HFABP (p = 0.015) plasma levels, whereas GDF-15 (p = 0.140), IGF-BP2 ( p = 0.088) and suPAR (p = 0.140) showed no significant differences. In addition, cut-off values were calculated to predict an MPA diameter ≥ 29 mm. Significant results were shown with 1634.00 pg/ml for BNP (p = 0.004), with 16.50 pg/ml for cTnI (p = 0.039) and with 1.16 ng/ml for H-FABP (p = 0.016). In a combined biomarker analysis, the 2-way combination of BNP and IGF-BP2 (AUC 0.671; 95%CI 0.538 - 0.805; p = 0.023) and the 3-way combination of BNP, H-FABP and IGF-BP2 (AUC 0.685; 95%CI 0.551 - 0.818; p = 0.015) showed the best results. Biomarker follow-up at 3 and 12 months after TAVR did not require additional information gain. Regarding 1-year survival, no significant difference could be detected between patients with an MPA diameter < 29 mm compared to patients with ≥ 29 mm (log-rank test: p = 0.262). CONCLUSIONS: The MPA diameter remains a controversial parameter for the detection of PH in patients with severe AS. Standing on its own, this non-invasive parameter may not be precise enough to detect PH accurately. Combining this parameter with several biomarkers did not provide significant additional information.

14.
J Pers Med ; 12(9)2022 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-36143238

RESUMO

BACKGROUND: Patients with severe aortic valve stenosis (AS) often present with heart failure and sarcopenia. Sarcopenia, described as progressive degradation of skeletal muscle mass, has frequently been implicated as a cause of increased mortality, prolonged hospitalization and generalized poor outcome after transcatheter aortic valve replacement (TAVR). At present, sarcopenia is defined by the European Working Group on Sarcopenia in Older People (EWGSOP) based on clinical examination criteria and radiological imaging. The aim of the present study was to compare patients with Computed Tomography (CT)-diagnosed sarcopenia with regard to the expression of cardiovascular biomarkers in order to obtain additional, laboratory-chemical information. METHODS: A total of 179 patients with severe AS were included in this retrospective study. Sarcopenia was determined via CT by measurement of the psoas muscle area (PMA), which was indexed to body surface area (PMAi). According to previous studies, the lowest tertile was defined as sarcopenic. Patients with (59/179) and without sarcopenia (120/179) in the overall cohort were compared by gender-specific cut-offs with regard to the expression of cardiovascular biomarkers such as brain natriuretic peptide (BNP), soluble suppression of tumorigenicity-2 (sST2), growth/differentiation of factor-15 (GDF-15), heart-type fatty-acid binding protein (H-FABP), insulin like growth factor binding protein 2 (IGF-BP2) and soluble urokinase-type plasminogen activator receptor (suPAR). Additionally, binary logistic regression analyses were calculated to detect possible predictors of the presence of sarcopenia. RESULTS: No statistical differences regarding one-year survival could be detected between sarcopenic and non-sarcopenic patients in survival curves (log rank test p = 0.179). In the entire cohort, only BNP and hemoglobin (HB) showed a statistically significant difference, with only HB emerging as a relevant predictor for the presence of sarcopenia after binary logistic regression analysis (p = 0.015). No relevant difference in biomarker expression could be found in the male cohort. Regarding the female cohort, statistically significant differences were found in BNP, HB and hematocrit (HK). In binary logistic regression, however, none of the investigated criteria could be related to sarcopenia. CONCLUSION: Regardless of gender, patients with imaging-based muscle degradation did not demonstrate significantly different cardiovascular biomarker expression compared to those without it.

15.
Diagnostics (Basel) ; 12(10)2022 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-36292052

RESUMO

Background: Computed tomography (CT) of the aorta and cardiac vessels, which is performed in patients with severe aortic valve stenosis (AS) before transcatheter aortic valve replacement (TAVR), offers the possibility of non-invasive detection of pulmonary hypertension (PH), for example, by determining the diameter of the main pulmonary artery (PA), the right pulmonary artery (RPA) or the left pulmonary artery (LPA). An improvement of the significance of these radiological parameters is often achieved by indexing to the body surface area (BSA). The aim of this study was to compare different echocardiographic systolic pulmonary artery pressure (sPAP) values with radiological data in order to define potential clinical cut-off values for the presence or absence of PH. Methods: A total of 138 patients with severe AS undergoing TAVR underwent pre-interventional transthoracic echocardiography with determination of sPAP values and performance of CT angiography (CTA) of the aorta and femoral arteries. Radiologically, the PA, RPA, LPA, and ascending aorta (AA) diameters were obtained. Vascular diameters were not only indexed to BSA but also ratios were created with AA diameter (for example PA/AA-ratio). From these CT-derived vascular parameters, AUROC curves were obtained regarding the prediction of different sPAP values (sPAP 40−45−50 mmHg) and finally correlation analyses were calculated. Results: The best AUROC and correlation analyses were generally obtained at an sPAP ≥ 40 mmHg. When considering diameters alone, the PA diameter was superior to the RPA and LPA. Indexing to BSA generally increased the diagnostic quality of the parameters, and finally, in a synopsis of all results, PA/BSA had the best AUC 0.741 (95% CI 0.646−0. 836; p < 0.001; YI 0.39; sensitivity 0.87; specificity 0.52) and Spearman's correlation coefficient (r = 0.408; p < 0.001) at an sPAP of ≥40 mmHg. Conclusions: Features related to pulmonary hypertension are fast and easily measurable on pre-TAVR CT and offer great potential regarding non-invasive detection of pulmonary hypertension in patients with severe AS and can support the echocardiographic diagnosis. In this study, the diameter of the main pulmonary artery with the additionally determined ratios were superior to the values of the right and left pulmonary artery. Additional indexing to body surface area and thus further individualization of the parameters with respect to height and weight can further improve the diagnostic quality.

16.
EuroIntervention ; 17(1): 23-31, 2021 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-32624457

RESUMO

The proposed 2020 Core Curriculum for Percutaneous Cardiovascular Interventions aims to provide an updated European consensus that defines the level of experience and knowledge in the field of percutaneous cardiovascular intervention (PCI). It promotes homogenous education and training programmes among countries, and is the cornerstone of the new EAPCI certification, designed to support the recognition of competencies at the European level and the free movement of certified specialists in the European Community. It is based on a thorough review of the ESC guidelines and of the EAPCI textbook on percutaneous interventional cardiovascular medicine. The structure of the current core curriculum evolved from previous EAPCI core curricula and from the "2013 core curriculum of the general cardiologist" to follow the current ESC recommendations for core curricula. In most subject areas, there was a wide - if not unanimous - consensus among the task force members on the training required for the interventional cardiologist of the future. The document recommends that acquisition of competence in interventional cardiology requires at least two years of postgraduate training, in addition to four years devoted to cardiology. The first part of the curriculum covers general aspects of training and is followed by a comprehensive description of the specific components in 54 chapters. Each of the chapters includes statements of the objectives, and is further subdivided into the required knowledge, skills, behaviours, and attitudes.


Assuntos
Cardiologia , Intervenção Coronária Percutânea , Cardiologia/educação , Consenso , Currículo , Europa (Continente) , Humanos
17.
Europace ; 10(5): 574-9, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18403387

RESUMO

AIMS: Left ventricular function may be altered by right ventricular apical pacing. The aims of the study were to compare the long-term course of different parameters of left ventricular dysfunction in patients undergoing implantation of a dual-chamber pacemaker with the ventricular lead in a septal position vs. in a standard apical position. METHODS: We randomized 98 patients with atrioventricular block (AV-block) undergoing pacemaker implantation to positioning the ventricular lead in the high or mid septum (n = 53) or in the apex (n = 45) of the right ventricle. N-terminal pro-brain natriuetic peptide (BNP) levels, left ventricular ejection fraction (LVEF), and exercise capacity were analysed 3 days, 3 months, and 18 months after the implantation. The primary endpoints were the changes of these parameters from baseline to 18 months. RESULTS: Changes of BNP levels, LVEF, and exercise capacity from baseline to 18 months were statistically not different between septal and apical stimulation. The clinical occurrence or deterioration of overt heart failure was similar in both treatment arms. CONCLUSION: With regard to different parameters of congestive heart failure, a septal stimulation site is not superior to conventional apical pacing in unselected patients undergoing pacemaker implantation for AV-block.


Assuntos
Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/prevenção & controle , Estimulação Cardíaca Artificial/métodos , Eletrodos Implantados , Septos Cardíacos , Ventrículos do Coração , Implantação de Prótese/métodos , Feminino , Humanos , Estudos Longitudinais , Masculino , Resultado do Tratamento
18.
Herzschrittmacherther Elektrophysiol ; 29(4): 334-339, 2018 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-30456580

RESUMO

Leadless pacemakers have the potential to fundamentally change the field of device therapy. As leads and generator pockets are no longer needed with this technology, many potentially dangerous complications of conventional pacemaker systems like lead fractures, lead endocarditis or pocket infections can be effectively avoided. At present, Micra™ (Medtronic Inc., Minneapolis, MN, USA) is the only commercially available leadless pacemaker. Since its first-in-human implantation in 2013, thousands of these devices have been implanted worldwide. This article presents an overview of the present clinical evidence and future perspectives of this promising new technology.


Assuntos
Marca-Passo Artificial , Desenho de Equipamento , Humanos , Próteses e Implantes
19.
Minerva Med ; 109(6): 443-450, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29652038

RESUMO

BACKGROUND: Peripheral artery disease (PAD) is a common form of manifestation of atherosclerosis. PAD has a considerable impact on morbidity, hospitalization rates and health-care costs. Biomarkers have been introduced in many cardiovascular disease entities over the last years. However, an analysis on the correlation of biomarker levels and PAD is still lacking. METHODS: A total of 106 patients were enrolled in this current study, 51 that were diagnosed with PAD and 55 with excluded coronary and peripheral artery disease as controls. During outpatient visits, plasma samples of all patients were obtained and analyzed for sST2 (hemodynamics and inflammation), galectin-3 (fibrosis and remodeling), GDF-15 (remodeling and inflammation), suPAR (inflammation), and fetuin-A (vascular calcification) by use of ELISA after informed consent. RESULTS: Compared with controls, patients with PAD showed significantly higher levels of sST2 (5248 vs. 7503 pg/mL, P<0.001), suPAR (2267 vs. 2414 pg/mL, P=0.02), galectin-3 (2795 vs. 4494 pg/mL, P<0.001), and GDF-15 (549 vs. 767 pg/mL, P<0.001). Fetuin-A showed a trend towards lower levels in patients with PAD (117 vs. 100 ng/mL, P=0.119). CONCLUSIONS: Circulating levels of sST2, suPAR, galectin-3, and GDF-15 were significantly elevated in PAD patients. In contrast, fetuin-A levels showed a decrease in PAD patients indicating increased vascular calcification. Thus, by incorporating different pathophysiological processes present in PAD, tested novel biomarkers facilitate a more precise diagnosis as well as a more accurate evaluation of disease severity and progression.


Assuntos
Doença Arterial Periférica/sangue , Idoso , Biomarcadores/sangue , Doenças Cardiovasculares/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Wien Klin Wochenschr ; 130(13-14): 427-435, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29796785

RESUMO

BACKGROUND: Leadless pacemaker systems are an important upcoming device in clinical rhythmology. Currently two different products are available with the Micra system (Medtronic) being the most used in the clinical setting to date. The possibility to perform magnetic resonance imaging (MRI) is an important feature of modern pacemaker devices. Even though the Micra system is suitable for MRI, little is yet known about its impact on artifacts within the images. OBJECTIVE: The aim of our ex vivo study was to perform cardiac MRI to quantify the artifacts and to evaluate if artifacts limit or inhibit the assessment of the surrounding myocardium. METHODS: After ex vivo implantation of the leadless pacemaker (LP) in a porcine model, hearts were filled with saline solution and fixed on wooden sticks on a plastic container. The model was examined at 1.5 T and at 3 T using conventional sequences and T2 mapping sequences. In addition, conventional X­rays and computed tomography (CT) scans were performed. RESULTS: Correct implantation of the LP could be performed in all hearts. In almost all MRI sequences the right ventricle and the septal region surrounding the (LP) were altered by an artifact and therefore would sustain limited assessment; however, the rest of the myocardium remained free of artifacts and evaluable for common radiologic diagnoses. A characteristic shamrock-shaped artifact was generated which appeared to be even more intense in magnitude and brightness when using 3 T compared to 1.5 T. CONCLUSION: The use of the Micra system in cardiac MRI appeared to be feasible. In our opinion, it will still be possible to make important clinical cardiac MRI diagnoses (the detection of major ischemic areas or inflammatory processes) in patients using the Micra system. We suggest the use of 1.5 T as the preferred method in clinical practice.


Assuntos
Artefatos , Imageamento por Ressonância Magnética/métodos , Marca-Passo Artificial , Animais , Ventrículos do Coração , Humanos , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA