Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Oral Investig ; 27(2): 739-750, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36484848

RESUMO

OBJECTIVES: An antimicrobial technique utilizing hydroxyl radicals generated by the photolysis of 3% H2O2 has been developed recently. The present study aimed to evaluate the effect of H2O2 photolysis treatment on tooth demineralization caused by Streptococcus mutans biofilm. MATERIALS AND METHODS: To induce tooth demineralization, S. mutans biofilm was allowed to form on the maxillary first molars collected from Wistar rats via 24-h culturing. The samples were immersed in 3% H2O2 and irradiated with 365-nm LED (H2O2 photolysis treatment). Viable bacterial counts in the biofilm were evaluated immediately after treatment and after an additional 30-h culturing by colony counting. The acidogenicity of the biofilm, re-established 30 h after treatment, was assessed by measuring the pH. The effect of H2O2 photolysis treatment on tooth demineralization was assessed by measuring the depth of the radiolucent layer in micro-CT images. RESULTS: H2O2 photolysis significantly reduced viable bacterial counts in the biofilm to 3.7 log colony forming units (CFU)/sample, while the untreated group had 7.9 log CFU/sample. The pH of the biofilm re-established after treatment (6.6) was higher than that of the untreated group (5.3). In line with the pH measurement, the treatment group had a significantly lower depth of radiolucent layer in dentin than the untreated group. CONCLUSIONS: H2O2 photolysis treatment was effective not only in killing the biofilm-forming S. mutans but also in lowering the acidogenicity of the biofilm. Thus, this technique could inhibit tooth demineralization. CLINICAL RELEVANCE: H2O2 photolysis can be applicable as a new dental caries treatment.


Assuntos
Anti-Infecciosos , Cárie Dentária , Desmineralização do Dente , Animais , Ratos , Peróxido de Hidrogênio/farmacologia , Cárie Dentária/microbiologia , Streptococcus mutans , Fotólise , Ratos Wistar , Desmineralização do Dente/tratamento farmacológico , Desmineralização do Dente/prevenção & controle , Anti-Infecciosos/farmacologia , Biofilmes
2.
Eur J Oral Sci ; 129(6): e12828, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34674326

RESUMO

This study analyzed the impact of adhesive primer and light-curing on the polymerization kinetics of urethane dimethacrylate-based self-adhesive resin cement combined with free radical reaction. Specimens were prepared by mixing the cement paste with or without adhesive primer. Subsequently, specimens were light-cured or set without light-curing. The degree of conversion (DC), Vickers hardness (Hv), and free radical concentrations were repeatedly measured up to 168 h after the curing initiation. Irrespective of the curing procedures, DC, Hv, and free radical concentration rapidly increased during the initial 30 min of curing. The specimens cured with adhesive primer and/or light-curing generally showed higher values of DC, Hv, and radical concentration than those set by chemical curing alone, especially during the initial polymerization phase. Kinetic analysis using a linear mixed model revealed that the adhesive primer had a higher coefficient estimate than light-curing, indicating that the former had a higher impact on the polymerization. Additionally, the adhesive primer alleviated the Hv reduction caused by water and air during the initial polymerization phase, although light-curing hardly prevented the polymerization inhibition. Therefore, we suggest that application of adhesive primer is beneficial to achieve higher degree of conversion and better mechanical properties of self-adhesive resin cements by enhancing free radical reactions.


Assuntos
Cura Luminosa de Adesivos Dentários , Cimentos de Resina , Lâmpadas de Polimerização Dentária , Cimentos Dentários , Radicais Livres , Dureza , Cinética , Teste de Materiais , Polimerização
3.
Regul Toxicol Pharmacol ; 90: 206-213, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28919392

RESUMO

We conducted an oral mucosal irritation study in hamsters to evaluate a therapeutic apparatus using hydrogen peroxide (H2O2) photolysis for periodontitis treatment (ISO 10993-Part 10, Annex B.3). The cheek pouches in 15 male hamsters were allocated to one of six groups. Group 1 received pure water treatment (control group). Group 2 received laser irradiation at 80 mW. Group 3 received 3% H2O2. Groups 4-6 received laser irradiation of 3% H2O2 at 80, 40, and 20 mW, respectively. The total treatment time was set at 7 min and treatment was repeated three times at approximately 1-h intervals. Macroscopic and microscopic histologic observations of the treated sites were performed immediately after each treatment and/or 24 h after the last treatment. The mean scores in macroscopic and histologic examinations in all six groups were 0. Accordingly, irritation indices calculated by subtracting the mean score in each experimental group from that in the control group (Group 1) were 0. Our results suggest that treatment with the apparatus has no mucosal irritation potential in hamster cheek pouches under test conditions simulating clinical conditions.


Assuntos
Anti-Infecciosos Locais/efeitos adversos , Desinfecção/métodos , Peróxido de Hidrogênio/efeitos adversos , Mucosa Bucal/efeitos dos fármacos , Periodontite/terapia , Animais , Anti-Infecciosos Locais/química , Desinfecção/instrumentação , Peróxido de Hidrogênio/química , Masculino , Mesocricetus , Mucosa Bucal/microbiologia , Periodontite/microbiologia , Fotólise
4.
Eur J Oral Sci ; 124(4): 387-95, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27203408

RESUMO

Resin-based composite molar crowns made by computer-aided design/computer-aided manufacturing (CAD/CAM) systems have been proposed as an inexpensive alternative to metal-ceramic or all-ceramic crowns. However, there is a lack of scientific information regarding fatigue resistance. This study aimed to analyze the fatigue behavior of CAD/CAM resin-based composite compared with lithium disilicate glass-ceramic. One-hundred and sixty bar-shaped specimens were fabricated using resin-based composite blocks [Lava Ultimate (LU); 3M/ESPE] and lithium disilicate glass-ceramic [IPS e.max press (EMP); Ivoclar/Vivadent]. The specimens were divided into four groups: no treatment (NT); thermal cycling (TC); mechanical cycling (MC); and thermal cycling followed by mechanical cycling (TCMC). Thermal cycling was performed by alternate immersion in water baths of 5°C and 55°C for 5 × 10(4) cycles. Mechanical cycling was performed in a three-point bending test, with a maximum load of 40 N, for 1.2 × 10(6) cycles. In addition, LU and EMP molar crowns were fabricated and subjected to fatigue treatments followed by load-to-failure testing. The flexural strength of LU was not severely reduced by the fatigue treatments. The fatigue treatments did not significantly affect the fracture resistance of LU molar crowns. The results demonstrate the potential of clinical application of CAD/CAM-generated resin-based composite molar crowns in terms of fatigue resistance.


Assuntos
Desenho Assistido por Computador , Coroas , Porcelana Dentária , Falha de Restauração Dentária , Cerâmica , Análise do Estresse Dentário , Humanos , Teste de Materiais
5.
Eur J Oral Sci ; 123(2): 122-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25683749

RESUMO

The aim of this study was to investigate whether different fabrication processes, such as the computer-aided design/computer-aided manufacturing (CAD/CAM) system or the manual build-up technique, affect the fracture resistance of composite resin-based crowns. Lava Ultimate (LU), Estenia C&B (EC&B), and lithium disilicate glass-ceramic IPS e.max press (EMP) were used. Four types of molar crowns were fabricated: CAD/CAM-generated composite resin-based crowns (LU crowns); manually built-up monolayer composite resin-based crowns (EC&B-monolayer crowns); manually built-up layered composite resin-based crowns (EC&B-layered crowns); and EMP crowns. Each type of crown was cemented to dies and the fracture resistance was tested. EC&B-layered crowns showed significantly lower fracture resistance compared with LU and EMP crowns, although there was no significant difference in flexural strength or fracture toughness between LU and EC&B materials. Micro-computed tomography and fractographic analysis showed that decreased strength probably resulted from internal voids in the EC&B-layered crowns introduced by the layering process. There was no significant difference in fracture resistance among LU, EC&B-monolayer, and EMP crowns. Both types of composite resin-based crowns showed fracture loads of >2000 N, which is higher than the molar bite force. Therefore, CAD/CAM-generated crowns, without internal defects, may be applied to molar regions with sufficient fracture resistance.


Assuntos
Resinas Compostas/química , Desenho Assistido por Computador , Coroas , Materiais Dentários/química , Planejamento de Prótese Dentária , Algoritmos , Cerâmica/química , Porcelana Dentária/química , Falha de Restauração Dentária , Análise do Estresse Dentário/instrumentação , Humanos , Teste de Materiais , Metacrilatos/química , Dente Molar , Maleabilidade , Poliuretanos/química , Porosidade , Estresse Mecânico , Propriedades de Superfície , Microtomografia por Raio-X/métodos
6.
Eur J Oral Sci ; 123(5): 375-380, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26315542

RESUMO

Zirconia-based dental restorations are becoming used more commonly. However, limited attention has been given to the difficulties experienced, concerning cutting, in removing the restorations when needed. The aim of the present study was to compare the cutting efficiency of diamond burs, operated using an electric high-speed dental handpiece, on zirconia (Zir) with those on lithium disilicate glass-ceramic (LD) and leucite glass-ceramic (L). In addition, evaluation of the cutting efficiency of diamond burs on Zir of different thicknesses was performed. Specimens of Zir were prepared with thicknesses of 0.5, 1.0, 2.0, and 4.0 mm, and specimens of LD and L were prepared with a thickness of 1.0 mm. Cutting tests were performed using diamond burs with super coarse (SC) and coarse (C) grains. The handpiece was operated at 150,000 rpm with a cutting force of 0.9 N. The results demonstrated that cutting of Zir took about 1.5- and 7-fold longer than cutting of LD and L, respectively. The SC grains showed significantly higher cutting efficiency on Zir than the C grains. However, when the thickness of Zir increased, the cutting depth was significantly decreased. As it is suggested that cutting of zirconia is time consuming, this should be taken into consideration in advance when working with zirconia restorations.

7.
Acta Odontol Scand ; 73(8): 602-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25635734

RESUMO

OBJECTIVES: The purpose of the present study was to analyze the relationship between fracture load of monolithic zirconia crowns and axial/occlusal thickness and to evaluate the fracture resistance of monolithic zirconia crowns with reduced thickness in comparison with that of monolithic lithium disilicate crowns with regular thickness. MATERIALS AND METHODS: Monolithic zirconia crowns (Lava Plus Zirconia, 3M/ESPE) with specified axial/occlusal thicknesses and lithium disilicate crowns (IPS e.max press, Ivoclar/Vivadent) with regular thickness were fabricated using a dental CAD/CAM system and a press technique, respectively. The crowns cemented onto dies were loaded until fracture. Based on measurements of the crown thickness made by micro-CT and the fracture load, multiple regression analysis was performed. RESULTS: It was revealed that the occlusal thickness significantly affected the fracture load (p < 0.01), but the axial thickness did not (p = 0.2828). Although the reduction of the occlusal thickness decreased the fracture resistance of the monolithic zirconia crowns, the fracture load of the zirconia crowns with the occlusal thickness of 0.5 mm (5558 ± 522 N) was significantly higher than that of lithium disilicate crowns with an occlusal thickness of 1.5 mm (3147 ± 409 N). CONCLUSION: Within the limitations of the present study, it is suggested that monolithic zirconia crown with chamfer width of 0.5 mm and occlusal thickness of 0.5 mm can be used in the molar region in terms of fracture resistance.


Assuntos
Coroas , Materiais Dentários/química , Planejamento de Prótese Dentária , Zircônio/química , Desenho Assistido por Computador , Porcelana Dentária/química , Falha de Restauração Dentária , Análise do Estresse Dentário/métodos , Módulo de Elasticidade , Humanos , Teste de Materiais , Dente Molar/anatomia & histologia , Maleabilidade , Cimentos de Resina/química , Estresse Mecânico , Propriedades de Superfície , Preparo Prostodôntico do Dente/métodos , Microtomografia por Raio-X/métodos
8.
J Clin Med ; 13(3)2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38337335

RESUMO

Vascular access (VA) flow suppression surgery augments VA flow resistance and can increase other circulation flows hindered by high-flow VA. However, whether VA flow suppression surgery affects cervical circulation has rarely been reported. We aimed to determine the effect of VA flow suppression surgery on the cervical circulation in patients with high-flow VA. This single-center, retrospective, observational study included 85 hemodialysis patients who underwent VA flow suppression surgery at the Kanno Dialysis and Access Clinic between 2009 and 2018. Blood flow in the VA, bilateral vertebral arteries, and common carotid artery was measured before and after VA flow suppression surgery. The VA flow decreased from 1548 mL/min to 693 mL/min postoperatively. The flow of the vertebral artery on the VA side increased from 55 mL/min to 81 mL/min. The flow in the bilateral common carotid arteries also increased. Patients whose symptoms improved postoperatively showed better improvement in the vertebral artery on the VA side. VA flow suppression surgery in patients with high-flow VA increases the flow of the vertebral artery on the VA side and of the bilateral common carotid arteries. High-flow VA can hinder the vertebral and common carotid circulation.

9.
Photochem Photobiol ; 100(1): 146-158, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37477119

RESUMO

The effect of terahertz (THz) radiation has been studied in medicine. However, there is a lack of scientific information regarding its possible mutagenicity. Therefore, the present study aimed to assess the mutagenicity of 1.6 THz laser irradiation. The Ames test was conducted using five bacterial tester strains. The bacteria were subjected to (i) 1.6 THz laser irradiation at 3.8 mW/cm2 for 60 min using a tabletop THz pulse laser system, (ii) ultraviolet irradiation, (iii) treatment with positive control chemicals (positive control) or (iv) treatment with the solvent used in the positive control (negative control). After treatment, the bacterial suspensions were cultured on minimal glucose agar to determine the number of revertant colonies. In addition, the comet assay was performed using fibroblasts (V79) to assess possible DNA damage caused by the THz laser irradiation. The Ames test demonstrated that the THz laser irradiation did not increase the number of revertant colonies compared to that in the negative control group, whereas the ultraviolet irradiation and positive control treatment increased the number of revertant colonies. Thus, 1.6 THz laser irradiation is unlikely to be mutagenic. The comet assay additionally suggests that the THz laser irradiation unlikely induce cellular DNA damage.


Assuntos
Dano ao DNA , Mutagênicos , Mutagênicos/toxicidade , Ensaio Cometa , Mutagênese , Fibroblastos/efeitos da radiação , Testes de Mutagenicidade
10.
Dent Mater ; 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38942711

RESUMO

OBJECTIVES: This study aimed to determine the crystalline phase composition of 3-6 mol% yttria-stabilized zirconia (3-6YSZ), specifically investigating the presence of tetragonal (t), cubic (c), and/or additional yttria-rich tetragonal (t') phase. METHODS: Laboratory-fabricated specimens comprising 3-5YSZ, resembling translucent dental zirconia ceramics (TZ specimens), and a blend of 3YSZ and 8YSZ, representing a c-phase reference, were prepared. Additionally, 25 dental zirconia products stabilized with 3-6 mol% yttria were analyzed. Whole X-ray diffraction (XRD) patterns were obtained for Rietveld analysis, complemented by fine scanning in the 2θ region from 72º to 76º for qualitative phase analysis. Moreover, yttria concentrations in each specimen were determined using X-ray fluorescence (XRF) spectroscopy. RESULTS: In the 2θ region from 72º to 76º, TZ and dental zirconia product specimens displayed four peaks attributed to t- and t'-phases, but the c-phase peak was absent. Rietveld analysis of the whole XRD patterns, utilizing a t-t' model, demonstrated the t-phase fraction ranging from 86 mass% in 3YSZ to 11 mass% in 6YSZ. Rietveld analysis appeared reliable, as the yttria contents calculated based on lattice parameters aligned well with those measured by XRF. This study established that dental 3-6YSZ consisted of yttria-lean t- and yttria-rich t'-phases. SIGNIFICANCE: The present study enhances understanding of the crystalline structure of dental zirconia ceramics. Future crystallographic analyses of these ceramics should consider the presence of t- and t'-phases.

11.
J Mech Behav Biomed Mater ; 146: 106067, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37567065

RESUMO

Monolithic dental prostheses made of 3-6 mol% yttria-stabilized zirconia (3-6YSZ) have gained popularity owing to their improved material properties and semi-automated fabrication processes. In this study, we aimed to evaluate the influence of mechanical surface treatments, such as polishing, grinding, and sandblasting, on the residual stress of 3-6YSZ used for monolithic prostheses in association with crystalline phase transformation. Plate specimens were prepared from five dental zirconia blocks: Aadva Zirconia ST (3YSZ), Aadva Zirconia NT (6YSZ), Katana HT (4YSZ), Katana STML (5YSZ), and Katana UTML (6YSZ). The specimens were either polished using 1, 3, or 9 µm diamond suspensions, ground using 15, 35, or 55 µm diamond discs, or sandblasted at 0.2, 0.3, or 0.4 MPa. The residual stress, crystalline phase, and hardness were analyzed using the cosα method, X-ray diffraction (XRD), and Vickers hardness test, respectively. Additionally, we analyzed the residual stress on the surfaces of monolithic zirconia crowns (MZCs) made of 4YSZ, 5YSZ, and 6YSZ, which were processed using clinically relevant procedures, including manual grinding, followed by polishing using a dental electric motor on the external surface, and sandblasting on the internal surface. Residual stress analysis demonstrated that grinding and sandblasting, particularly the latter, resulted in the generation of compressive residual stress on the surfaces of the plate specimens. XRD revealed that the ground and sandblasted specimens contained a larger amount of the rhombohedral phase than that of the polished specimens, which may be a cause of the residual stress. Sandblasting significantly increased the Vickers hardness compared to polishing, which may possibly be due to the generation of compressive residual stress. In the case of MZCs, compressive residual stress was detected not only on the sandblasted surface, but also on the polished surface. The difference in the residual stress between the plate and crown specimens may be related to the force applied during the automated and manual grinding and polishing procedures. Further studies are required to elucidate the effects of the compressive residual stress on the clinical performance of MZCs.


Assuntos
Ítrio , Zircônio , Teste de Materiais , Propriedades de Superfície , Zircônio/química , Ítrio/química , Cerâmica/química , Diamante , Materiais Dentários , Polimento Dentário , Estresse Mecânico
12.
Antimicrob Agents Chemother ; 56(1): 295-301, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22024818

RESUMO

The purpose of the present study is to evaluate the effect of thermal energy on the yield of and the bactericidal action of hydroxyl radical generated by photolysis of H(2)O(2). Different concentrations of H(2)O(2) (250, 500, 750, and 1,000 mM) were irradiated with light-emitting diodes (LEDs) at a wavelength of 400 ± 20 nm at 25°C to generate hydroxyl radical. The 500 mM H(2)O(2) was irradiated with the LEDs at different temperatures (25, 35, 45, and 55°C). Electron spin resonance spin trapping analysis showed that the yield of hydroxyl radicals increased with the temperature, as well as the concentration of H(2)O(2). Streptococcus mutans and Enterococcus faecalis were used in the bactericidal assay. The LED-light irradiation of the bacterial suspensions in 500 mM H(2)O(2) at 25°C could hardly kill the bacteria within 3 min, while the bactericidal effect was markedly enhanced with the temperature rise. For instance, a temperature increase to 55°C resulted in >99.999% reduction of viable counts of both bacterial species only within 1 min. The photolysis of 500 mM H(2)O(2) at 55°C could reduce the viable counts of bacteria more efficiently than did the photolysis of 1,000 mM H(2)O(2) at 25°C, although the yields of hydroxyl radical were almost the same under the both conditions. These findings suggest that the thermal energy accelerates the generation of hydroxyl radical by photolysis of H(2)O(2), which in turn results in a synergistic bactericidal effect of hydroxyl radical and thermal energy.


Assuntos
Enterococcus faecalis/efeitos dos fármacos , Peróxido de Hidrogênio/farmacologia , Radical Hidroxila/metabolismo , Viabilidade Microbiana/efeitos dos fármacos , Streptococcus mutans/efeitos dos fármacos , Antibacterianos/química , Antibacterianos/farmacologia , Espectroscopia de Ressonância de Spin Eletrônica , Enterococcus faecalis/crescimento & desenvolvimento , Temperatura Alta , Peróxido de Hidrogênio/química , Lasers Semicondutores , Luz , Fotólise/efeitos da radiação , Streptococcus mutans/crescimento & desenvolvimento
13.
Microbiol Immunol ; 56(1): 48-55, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22040121

RESUMO

The purpose of the present study was to evaluate the mechanism of microbial resistance to oxidative stress induced by photolysis of hydrogen peroxide (H(2)O(2)) in relation to microbial catalase activity. In microbicidal tests, Staphylococcus aureus and Candida albicans were killed and this was accompanied by production of hydroxyl radicals. C. albicans was more resistant to hydroxyl radicals generated by photolysis of H(2)O(2) than was S. aureus. A catalase activity assay demonstrated that C. albicans had stronger catalase activity; accordingly, catalase activity could be one of the reasons for the resistance of the fungus to photolysis of H(2)O(2). Indeed, it was demonstrated that C. albicans with strong catalase activity was more resistant to photolysis of H(2)O(2) than that with weak catalase activity. Kinetic analysis using a modified Lineweaver-Burk plot also demonstrated that the microorganisms reacted directly with hydroxyl radicals and that this was accompanied by decomposition of H(2)O(2). The results of the present study suggest that the microbicidal effects of hydroxyl radicals generated by photolysis of H(2)O(2) can be alleviated by decomposition of H(2)O(2) by catalase in microorganisms.


Assuntos
Candida albicans/efeitos da radiação , Catalase/metabolismo , Resistência Microbiana a Medicamentos , Peróxido de Hidrogênio/metabolismo , Estresse Oxidativo , Fotólise , Staphylococcus aureus/efeitos da radiação , Antibacterianos/metabolismo , Antibacterianos/farmacologia , Antifúngicos/metabolismo , Antifúngicos/farmacologia , Proteínas de Bactérias/metabolismo , Candida albicans/efeitos dos fármacos , Candida albicans/enzimologia , Meios de Cultura , Ativação Enzimática , Proteínas Fúngicas/metabolismo , Peróxido de Hidrogênio/farmacologia , Peróxido de Hidrogênio/efeitos da radiação , Radical Hidroxila/metabolismo , Radical Hidroxila/farmacologia , Testes de Sensibilidade Microbiana , Oxirredução , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/enzimologia
14.
Eur J Oral Sci ; 120(3): 249-54, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22607342

RESUMO

The aim of the present investigation was to study the influence of grain size on the strength of yttria-stabilized zirconia upon exposure to an additional heat treatment, mimicking the veneering process. The green bodies of zirconia discs prepared by cold isostatic pressing were sintered at 1,425, 1,500, or 1,575°C to customize the grain size. The disc-shaped specimens were highly polished and then processed with or without additional heat treatments (five times at 850-930°C). Ten specimens from each treatment group were subjected to a biaxial flexural strength test according to the ISO 6872 standard. The grain size of the specimens was analyzed by the mean linear intercept technique using scanning electron microscopy. It was demonstrated that the mechanical strength of zirconia ceramics was not reduced by the veneer firing processes when polished specimens were used, but the strength was found to decrease with increasing grain size. The raw materials and the sintering process used should be selected appropriately to avoid grain coarsening because it was found that the strength was influenced by large grains.


Assuntos
Porcelana Dentária/química , Planejamento de Prótese Dentária , Facetas Dentárias , Ítrio/química , Zircônio/química , Análise do Estresse Dentário , Temperatura Alta , Humanos , Teste de Materiais , Maleabilidade , Estresse Mecânico
15.
Ergonomics ; 55(4): 450-64, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22423677

RESUMO

In recent years, various efforts have been made in air traffic control (ATC) to maintain traffic safety and efficiency in the face of increasing air traffic demands. ATC is a complex process that depends to a large degree on human capabilities, and so understanding how controllers carry out their tasks is an important issue in the design and development of ATC systems. In particular, the human factor is considered to be a serious problem in ATC safety and has been identified as a causal factor in both major and minor incidents. There is, therefore, a need to analyse the mechanisms by which errors occur due to complex factors and to develop systems that can deal with these errors. From the cognitive process perspective, it is essential that system developers have an understanding of the more complex working processes that involve the cooperative work of multiple controllers. Distributed cognition is a methodological framework for analysing cognitive processes that span multiple actors mediated by technology. In this research, we attempt to analyse and model interactions that take place in en route ATC systems based on distributed cognition. We examine the functional problems in an ATC system from a human factors perspective, and conclude by identifying certain measures by which to address these problems. This research focuses on the analysis of air traffic controllers' tasks for en route ATC and modelling controllers' cognitive processes. PRACTITIONER SUMMARY: This research focuses on an experimental study to gain a better understanding of controllers' cognitive processes in air traffic control. We conducted ethnographic observations and then analysed the data to develop a model of controllers' cognitive process. This analysis revealed that strategic routines are applicable to decision making.


Assuntos
Aviação/organização & administração , Técnicas de Apoio para a Decisão , Análise e Desempenho de Tarefas , Fluxo de Trabalho , Adulto , Cognição , Tomada de Decisões , Ergonomia , Humanos , Pessoa de Meia-Idade , Radar , Carga de Trabalho , Adulto Jovem
16.
Sci Prog ; 104(3): 368504211031097, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34281440

RESUMO

Vascular access (VA) is necessary for patients on hemodialysis, and percutaneous transluminal angioplasty (PTA) is a useful treatment for maintaining VA function. PTA immediately increases the VA flow volume, which can affect cardiac function. We investigated the relationship between changes in VA flow volume and cardiac function in patients who underwent PTA. This was a single-center retrospective observational study, including patients who underwent PTA between June 2016 and August 2016. VA flow volume and cardiac function were measured by sonography before and 1 h after PTA. This study included 50 PTA procedures in 50 cases. PTA significantly increased the median VA flow volume from 445 (range, 150-1229) to 725 (350-1268) mL/min. Although the ejection fraction and diameter of the inferior vena cava were unchanged, the cardiac output (CO) and cardiac index increased significantly in most cases. Surprisingly, the CO was decreased in 18% of cases despite the increased VA flow volume. In this atypical group, a high CO before PTA was found to be a significant factor for the decrease in CO by PTA. In most cases, both VA flow volume and CO were increased by PTA, whereas in some cases, the CO was decreased despite an increase in VA flow volume. This atypical phenomenon may be due to the insufficient adaptive response in the peripheral artery and heart and could predict risks for future cardiac events. Therefore, it is important that such patients are carefully followed up on.


Assuntos
Angioplastia , Diálise Renal , Humanos , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
17.
Antimicrob Agents Chemother ; 54(12): 5086-91, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20921319

RESUMO

The relationship between the amount of hydroxyl radicals generated by photolysis of H(2)O(2) and bactericidal activity was examined. H(2)O(2) (1 M) was irradiated with laser light at a wavelength of 405 nm to generate hydroxyl radicals. Electron spin resonance spin trapping analysis showed that the amount of hydroxyl radicals produced increased with the irradiation time. Four species of pathogenic oral bacteria, Staphylococcus aureus, Aggregatibacter actinomycetemcomitans, Streptococcus mutans, and Enterococcus faecalis, were used in the bactericidal assay. S. mutans in a model biofilm was also examined. Laser irradiation of suspensions in 1 M H(2)O(2) resulted in a >99.99% reduction of the viable counts of each of the test species within 3 min of treatment. Treatment of S. mutans in a biofilm resulted in a >99.999% reduction of viable counts within 3 min. Other results demonstrated that the bactericidal activity was dependent on the amount of hydroxyl radicals generated. Treatment of bacteria with 200 to 300 µM hydroxyl radicals would result in reductions of viable counts of >99.99%.


Assuntos
Desinfecção/métodos , Peróxido de Hidrogênio/química , Radical Hidroxila/química , Fotólise , Espectroscopia de Ressonância de Spin Eletrônica , Enterococcus faecalis/efeitos dos fármacos , Radical Hidroxila/farmacologia , Testes de Sensibilidade Microbiana , Staphylococcus aureus/efeitos dos fármacos , Streptococcus mutans/efeitos dos fármacos
18.
J Photochem Photobiol B ; 212: 112042, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33027729

RESUMO

Hydrogen peroxide photolysis-based antimicrobial chemotherapy that utilizes ultraviolet-A irradiation (UVA-H2O2 photolysis) has been previously proposed as a method of treatment of cariogenic biofilm. Therefore, in the present study, we aimed to assess time-dependent reactions in the dental pulp of rats after UVA-H2O2 photolysis. Maxillary first molars were treated. UVA irradiation (wavelength: 365 nm) with 3 wt% H2O2 was performed for 90 s at a radiant emittance of 500-2000 mW/cm2 on the rats for 3 consecutive days or only 1 day. The animals were sacrificed at Days 1, 3, 7, and 21 after the treatment for the histological evaluation of inflammatory cells and immunohistochemistry of heat shock protein (HSP)-25, a marker of odontoblasts. Tertiary dentin formation was evaluated at Day 21 by histomorphometry and micro-CT analysis. UVA-H2O2 photolysis elicited little infiltration of inflammatory cells, but disturbances in the odontoblast layer and/or presence of localized degenerative tissue were observed on Day 3. This condition was followed by a healing process that was characterized by the reappearance of HSP-25 positive odontoblast-like cells at Day 7 and tertiary dentin formation at Day 21. The amount of tertiary dentin formed was dependent on the intensity of treatment; repeated UVA irradiations of H2O2 at 2000 mW/cm2 resulted in the largest amount of tertiary dentin formation at the pulp horn regions. Our findings suggest that UVA-H2O2 photolysis treatment can be used to treat dental caries clinically because the post-treatment inflammatory reaction was minimal and tertiary dentin formation was substantial, which may prove effective in protecting dental pulp from external irritants. As a cautionary consideration, the radiant emittance of the UVA irradiation should be carefully optimized before clinical application.


Assuntos
Anti-Infecciosos/farmacologia , Polpa Dentária/efeitos dos fármacos , Polpa Dentária/efeitos da radiação , Peróxido de Hidrogênio/farmacologia , Fotólise , Raios Ultravioleta , Animais , Polpa Dentária/metabolismo , Polpa Dentária/microbiologia , Proteínas de Choque Térmico HSP27/metabolismo , Peróxido de Hidrogênio/química , Ratos , Fatores de Tempo
19.
J Mech Behav Biomed Mater ; 111: 103974, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32769070

RESUMO

Monolithic dental prostheses fabricated from 3 mol.% yttria-stabilized zirconia (3YZ) are becoming increasingly popular. Recently, 5 mol.% yttria-stabilized zirconia (5YZ) which significantly improves the translucency of 3YZ has been prepared. However, its mechanical and microstructural properties, especially those affected by low-temperature degradation (LTD), have not been fully elucidated yet. The objective of the present study was to establish the relationship between the flexural strength of 5YZ with or without autoclave-induced LTD and its microstructural properties. For this purpose, a total of 320 bar-shaped specimens were cut from 5YZ and 3YZ blocks, and half of the specimens in each group were autoclaved at 134 °C for 50 h. Their flexural strengths were determined by conducting three-point bending tests, and the obtained results were analyzed by the Weibull statistical method. Grain sizes and crystalline structures of the specimens were analyzed by scanning electron microscopy (SEM) and X-ray diffraction, respectively. Additionally, the LTD-induced phase transformation was examined by Raman microscopy and cross-sectional surface analysis. The characteristic strengths of 5YZ and 3YZ were approximately 620 and 950 MPa, respectively, and 5YZ was found to be more resistant to LTD in terms of phase transformation than 3YZ. However, a low amount of the monoclinic phase was detected even in 5YZ after 50 h of autoclaving, which significantly decreased its flexural strength and reliability. The results of SEM analysis revealed that 5YZ was composed of two distinct regions: a dominant matrix with large grains (median size: 0.8 µm) and scattered areas with small grains (median size: 0.4 µm). Phase transformation analysis and fractography data indicated that the small-grain region was strongly affected by LTD and likely represented a fracture origin. The described properties should be considered during the clinical application of monolithic 5YZ dental prostheses.


Assuntos
Ítrio , Zircônio , Cerâmica , Estudos Transversais , Materiais Dentários , Teste de Materiais , Reprodutibilidade dos Testes , Estresse Mecânico , Propriedades de Superfície , Difração de Raios X
20.
Sci Rep ; 10(1): 8812, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32483182

RESUMO

The purpose of the present study was to confirm if proanthocyanidin-rich grape seed extract (GSE) had the ability to improve bone health such as bone loss, bone healing, and implant osseointegration (defined as the direct connection between bone tissue and an implant) in ovariectomized (OVX) animals. We demonstrated that daily oral administration of GSE prevented bone loss in the lumbar vertebrae and femur in OVX mice. In addition, osteoclastogenesis in the lumbar spine bone of OVX mice, as assessed by histological and histomorphometric analyses, was accelerated but GSE prevented this dynamization, suggesting that GSE could counteract OVX-induced accelerated osteoclastogenic activity. In rats, OVX clearly impaired the healing of defects created on the calvaria, and GSE overcame this OVX-impaired healing. In the same way, osseointegration of a tibial implant in rats was retarded by OVX, and GSE counteracted the OVX-induced poor osseointegration, likely promoting bone healing by preventing imbalanced bone turnover. These results suggest that orally administered GSE improved implant osseointegration by mitigating the impaired bone health induced by OVX as a model of estrogen deficiency.


Assuntos
Prótese Ancorada no Osso , Extrato de Sementes de Uva/uso terapêutico , Osseointegração/efeitos dos fármacos , Osteoporose Pós-Menopausa/prevenção & controle , Proantocianidinas/uso terapêutico , Animais , Remodelação Óssea/efeitos dos fármacos , Estrogênios/deficiência , Estrogênios/fisiologia , Feminino , Fêmur/ultraestrutura , Extrato de Sementes de Uva/farmacologia , Humanos , Camundongos , Osteoclastos , Osteoporose Pós-Menopausa/tratamento farmacológico , Ovariectomia , Proantocianidinas/farmacologia , Ratos , Ratos Wistar , Tíbia/fisiopatologia , Tíbia/cirurgia , Titânio , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA